Anatomix RP X-Ray System

Similar documents
Anatomix Plus X-Ray System

RD-90 Developer-Replenisher F-Fix Fixer-Replenisher

FUJIFILM Europe DIS (Direct Injection System)

MINIMUM REQUIREMENTS FOR A DARKROOM.

Guide to Manual Processing of NDT Films

Using the KODAK EKTACOLOR Processing Cartridge 111 with Digital Minilabs (Processes CP-48S and CP-49E)

Using the KODAK Negative Film Processing Cartridges FC1 and FC2

Using the KODAK EKTACOLOR Processing Cartridge 111 with Digital Minilabs using Processes CP-48S and CP-49E

50 Tips for Manual Processing

ILFORD FP4 PROCESS CONTROL STRIPS & FILM PROCESS CONTROL

KODAK MIN-R S Film / 4906

Using the KODAK Negative Film Processing Cartridges FC1 and FC2

INTRODUCTION TO THE FPC PROCESS CONTROL

10 ROTARY-TUBE PROCESSORS

Using KODAK Negative Film Processing Chemicals, Type L

TECHNICAL INFORMATION

USING KODAK CHEMICALS IN MINILABS

Using KODAK Kit Chemicals in Motion Picture Film Laboratories

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

Wimberley Developer #2, Version D+ 1 liter kit (Dry) CATALOG NO TO MAKE 50 LITERS OF WORKING SOLUTION

A POWDER FILM DEVELOPER AND REPLENISHER FOR THE HIGH VOLUME BLACK AND WHITE FILM PROCESSING IN DEEP TANKS AND DIP & DUNK (HANGER) PROCESSORS

KODAK X-OMAT BT Film / 4530 / XBT

KODAK Medical X-ray Film / General Purpose / Blue / 3528 / MXB

KODAK T-MAX 100 Direct Positive Film Developing Outfit

Preparing Smaller-Than-Package-Size Amounts of KODAK Processing Chemicals

Fig. 1. A. Adjustable section of film holder. B. Notched portion. C. Projection guides. D. Back stop

Film and processing quality assurance

ILFORDINFO HOW TO PROCESS YOUR FIRST BLACK AND WHITE FILM

Technical Data Agfa B/W Chemicals Film processing

KODAK Simulation Film / 7157

5 Using KODAK EKTACOLOR RA Chemicals with Tray, Drum, and Rotary-Tube Processors

KODAK PROFESSIONAL T-MAX Developers

INDUSTREX Film. For Non-Destructive Testing WHEN CLARITY IS CRITICAL

1 KODAK EKTACOLOR Chemicals

Using KODAK Control Strips for Processes AR-5 and AN-6

EASTMAN TRI-X Reversal Film 7278

TROUBLESHOOTING PROCESSES C-41 AND RA-4

Processing and. Photography. Printing

Monitoring Process RA-4 for Silver-Halide Digital Printers

Troubleshooting. Agfa Dentus Intraoral radiography Troubleshooting Guide. Giving a hand to oral health.

Using KODAK EKTACOLOR Processing Cartridge 92/110

RA Duplicating Film X-OMAT 5000 RA Processor; RP X-OMAT Chemicals; 90 Second Cycle; Diffuse Visual Densitometry. Density

Best Practice in Photo tooling. Eric Janssens Februari 2016

Surprises with Light JoAnne Dombrowski

Dental Radiography Series

PERCEPTOL, ID-11 AND MICROPHEN FILM DEVELOPERS

SAFETY DATA SHEET VILLAS BITUMEN

KODAK PROFESSIONAL HC-110 Developer

KODAK INDUSTREX AA400 Film Versatility is the key.

ARS-IMAGO CHEMICALS DATA SHEETS

ISO 400/27 o BLACK AND WHITE PROFESSIONAL FILM FOR HIGH PRINT QUALITY AND FLEXIBILITY IN USE

These Application Instructions cover surface preparation, application equipment and application details for HEMPADUR MASTIC 45880/45881.

KODAK HC-110 Developer

How to Print: Making an Enlargement from a Negative in the Darkroom

TECHNICAL INFORMATION Küsnacht, February 2004 (rev. 1/09) THICKFILM STENCILS FOTECOAT 1845 SOLO

Autofluor. Autoradiographic Image Intensifier. Documented... Autofluor is Superior! C 3 PPO-DMSO. Autofluor

Minilab Compendium. Data and Product Information

MATERIAL SAFETY DATA SHEET Utrecht Gesso Painting Grounds. Section 2 Hazard Identification (composition / information on ingredients)

PrintED Press Operations Sample Exam Questions

Bright Precious Metal Preparations for the Production of Decals for Glass

BLACK AND WHITE, ORTHOCHROMATIC COPY FILM

DULUX UNIVERSAL UNDERCOAT

KODAK PROFESSIONAL TRI-X 320 and 400 Films

MULTIGRADE FB WARMTONE 1

EASTMAN PLUS-X Reversal Film / 7276

Panchromatic negative film for aerial photography

Technical Information

imaging guide metalphoto 400 PROCESSING

COMPOSITES LAB MANUAL

FORMULARY P.O. Box 950 Condon MT FAX

TABLE OF CONTENTS. SI No Contents Page No.

Darkroom printing. Pictionary_tutorial

NDE SOLUTIONS RADIOGRAPHY COURSE OUTLINE

SOUTHLAND DISTRIBUTION & SALES 4003 Enterprise Court, Augusta, GA 30907, ,

GE Measurement & Control. STRUCTURIX Equipment

TECHNICAL INFORMATION

MATERIAL SAFETY DATA SHEET Utrecht Gesso Painting Grounds

CUPRON NEXT TECHNICAL DATA SHEET

8 PROCESS CONTROL. Monitoring the Process with KODACHROME 64 Control Film

MATERIAL SAFETY DATA SHEET GLITTER

Firework Colors. 5 g each of the following compounds (in finely powdered form):

TECHNICAL INFORMATION Crystal Violet (Methyl Violet) Catalog Nos. LV502, LV5021

KORU. Providing the graphic industry with top quality film and plates. KORU, an introduction

AVITONE PD 1 P-OS AND PD 3 P-OS

INSTRUCTION MANUAL. 150x Power Student Microscope Biological Experiments Gear 1.5V WARNING: WARNING: NOT INCLUDED

ISO 400/27º, BLACK AND WHITE PROFESSIONAL FILM FOR HIGH PRINT QUALITY AND FLEXIBILITY IN USE

Sketchpaint. Ideal for turning any smooth surface into a whiteboard. Ready to use in 5 days

380 Swimming Pool Paint

SCIENCE EXPERIMENTS ON FILE Revised Edition Common Cents. Bruce Hogue. Safety Please click on the safety icon to view the safety precautions.

TECHNICAL DATA / COLOR PAPER July 2003 E-23

Assembly instructions

Processing guide for IMAGIN

MATERIAL SAFETY DATA SHEET Utrecht Acrylic Mediums & Varnish. Section 2 Hazard Identification (composition / information on ingredients)

B Operating Instructions V1.00/EN/

BALSA WOOD (Refer also to Auszac SDS for Wood Dust) Structural core material, model making, craft items, surfboards.

NOTES ON PRINTING 08/06

KODAK ROYAL Digital Paper

KODALITH Ortho Films 2556,6556, Type 3

GALERIE RC DIGITAL SILVER

LUXAR Anti reflective coated glass Handling Procedures for LUXAR

Transcription:

T E C H N I C A L I N F O S H E E T Anatomix RP X-Ray System I. SYSTEM DESCRIPTION Anatomix RP liquid concentrates are formulated for use in all automatic processing machines for all standard time cycles, except the short processing time of 45. Anatomix RP Developer Replenisher is used to prepare both tank solution (using Anatomix Developer Starter) and replenisher solutions. Anatomix RP Fixer & Replenisher is the companion of Anatomix RP Developer Replenisher. No starter is necessary. II. GENERAL PROCESS SPECIFICATIONS A. Temperature Anatomix RP Developer and Anatomix RP Fixer may be utilised over a wide temperature range to suit different machine time cycles to obtain optimum results. Machine time cycle (sec.) Operating temperature ( C) 60 38 (37 39) 90 35 (34 36) 120 34 (33 35) 150 33 (31 34) B. Replenishment rates Developer (*) Fixer Fixer (with continuous electrolytic desilvering) 400 ml/m² 600 ml/m² 300 ml/m² (*) These rates may vary depending on : 1. The amount of film processed daily - low use rates produce high oxidation rates. 2. The operating temperature chosen - oxidation increases with temperature increase. 3. The size of film being used - small sheets usually cause higher aerial oxidation. 4. The machine tank size - surface to volume ratio affects aerial oxidation rate. 5. The degree of image produced - higher blackness requires more developer replenishing. If the processor is subject to low film usage or long periods of inactivity, aerial oxidation will occur. It will be necessary to increase developer replenishment rates to maintain an adequate activity.

EXAMPLE : Quantity of films per day (35 x 43 cm) Developer Fixer 0-25 75 ml/film 112 ml/film 25-100 70 ml/film 105 ml/film 100-150 60 ml/film 90 ml/film III. MIXING INSTRUCTIONS A. Anatomix RP Developer 1. Anatomix RP Developer Replenisher Water Part A Part B To make 14.5 L + 5 L + 0.5 L 20 L 2. Anatomix RP Developer (To fill processor developer tank) Water Part A Part B Anatomix Developer Starter To make 14,12 L + 5 L + 0.5 L + 0.38 L 20 L B. Anatomix RP Fixer (Processor tank and replenisher) Water Part A Part B To make 15 L + 4.5 L + 0.5 L 20 L IV. PH AND DENSITY SPECIFICATIONS ph (25 C) Density (20 C) g/cm³ Developer 10.30 ± 0.05 1.076 ± 0.003 Developer Replenisher 10.80 ± 0.05 1.076 ± 0.003 Fixer 4.45 ± 0.05 1.091 ± 0.005 V. CONTINUOUS ELECTROLYTIC FIXER DESILVERING In order to substantially reduce the fixer replenishment rate and to reduce silver carry-over into the processor wash tank FUJIFILM recommends the use of a suitable fixer desilvering unit. The silver content of the processor fixing bath should be maintained at 0.3-1.0 of silver/l. Page 2 / 6

VI. PROCESSOR TANK CLEANLINESS If the processor shows signs of dirt or crystals built up on rollers, tank or cross-overs, the machine should be emptied, thoroughly washed out and then filled with FUJIFILM Unicleaner PD solution. Read instructions packed with the cleaner before use to avoid damage to machine or chemical reactions. Remember to carefully clean off any deposit on the cross-over mechanism, otherwise scratching of the emulsion may occur. VII. FILM WASHING Ensure adequate washing of films is achieved by adhering to processor manufacturer s recommendations. If an electrolytic fixer desilvering unit is used in a continuous mode with the processor s fixer tank solution the carry-over of silver into the wash tank will be substantially reduced. This has the benefit of reducing the amount of silver complex in the processor wash water effluent. Normally a reduction to about 1/10 th of the normal concentration can be achieved. VIII. BIOLOGICAL GROWTH IN WASH TANK Open wash system It is not usual for biological growth to be found in well-maintained processors with open wash systems and adequate wash water flow rates (1-3 litres/minute). If problems are experienced it is best to first have an examination of the water quality and supply system, carried out by a specialist company. Various biocides compatible with photographic processors are available. FUJIFILM Algstop LR is very effective in preventing algae growth during shutdown periods. It is only necessary to add 1 ml of Algstop LR concentrate for each litre of wash water capacity to the wash tank at the end of a processing session. An automatic Algstop Dosing Unit is available from FUJIFILM. Closed, recirculated wash systems In the low wash water usage and high temperature conditions resulting from recirculation of washwater, it has proven to be difficult to keep bio-growth under control. Alstop LR from FUJIFILM is the recommended product for these difficult conditions. For full details on the usage of Algstop LR, please ask for the separate FUJIFILM Technical Info Sheets AlgStop. Use biocides safely. Always read the label and product information before use! Page 3 / 6

IX. TROUBLESHOOTING GUIDE Problem Possible Cause Action to be taken Light Image. Light Image (sudden effect). Image too dense. Fogged film. 1. Developer temperature too low. 2. Under replenishment of developer. 3. Exhausted developer. 4. Developer contaminated by fixer. 5. Over diluted developer. 6. Mixing error. 7. Weak or insufficient exposure. 8. Processing time too short. 9. Too much starter. Developer contamination* by fixer. 1. Developer temperature too high. 2. Over replenishment of developer. 3. Processing time too long. 4. Overexposed film. 5. Insufficient amount of starter. 1. Unsuitable darkroom light. 2. Light leak into darkroom. 1. Check the temperature with a thermometer and adjust setting. 2. Check replenishment pumps & settings and adjust accordingly. 3. Make new fresh solution. 4. Check mixing procedures - if needed make new fresh solution. 5. Check mixing procedures - if needed make new fresh solution. 6. Check mixing procedures - if needed make new fresh solution. 7. Check equipment used for exposure. 8. Check speed of processor and adjust it if required. 9. Check mixing procedures - make new solution. Check mixing procedures - make new developer solution. 1. Check the temperature with a thermometer and adjust settings. 2. Check replenishment rates, pumps & settings and adjust accordingly. 3. Check speed of processor and adjust accordingly. 4. Check equipment used for exposure. 5. Check mixing procedures - make new solution. 1. Follow film manufacturer s recommendations. Safety light must be at distance of 1,2 m min. Check if light bulb is of the correct type. 2. Examine darkroom for light leaks. Mottles. Film does not dry. White spots on light areas of film. Small particles on film. Developer rollers are excessively worn or damaged. 1. Drying temperature too low. 2. Wash-water flow too low. 3. Ineffective fixer. 4. Relative humidity too high. 1. Fixer temperature too low. 2. Under replenished fixer. 3. Mixing error for fixer. 4. Insufficient wash. Dirt in solution. Change rollers if thorough cleaning proves to be insufficient. 1. Check temperature and raise it if necessary. 2. Check flow rate & temperature and adjust to standard. 3. Check replenishment rate and adjust accordingly. 4. Dry the air in working area. 1. Check with reliable thermometer and adjust accordingly. 2. Check rate of replenishment and adjust as necessary. 3. Check mixing procedure and mixing tank calibration. 4. Check wash flow rate and increase as required. Check solution circulation, filter and pump. Page 4 / 6

Problem Possible Cause Action to be taken White transparent spots on films. White or dark halfmoon shaped marks on film. Parallel black & transparent stripes. Dark black marks. Dark or light spots on film (comet shaped). Soiled film after drying. White layer on film. Yellow stain on film after storage. 1. Spilling or splashing of fixer before processing. 2. Soiled screen. 3. Particles of emulsion lifting from film. 4. Air bubbles between roller and film in developer. Film has been folded or bent before processing. Uneven pressure from distorted rollers in the developer section of the processor. 1. Electrostatic discharge. 2. Pressure applied during handling. Splashing of chemicals (fixer or detergents) before processing. Drying temperature too high. 1. Wash flow rate too low. 2. Soiled/exhausted fixer bath. Insufficient fixation. 1. Handle films with care and clean hands. 2. Clean screen. 3. Clean rollers. Check that fixer replenishment rate is sufficient.** 4. Check solution circulation, pump and filter. Handle film with care, do not bend. Clean machine thoroughly - have machine manufacturer check rollers. 1. Check relative humidity. 2. Handle films smoothly and with care. Clean up working & loading areas. Check temperature and adjust it to recommended value. 1. Check flow rate & temperature of wash water - adjust if needed. 2. Check mixing procedure - prepare new fix solution. Check fix replenishment rate. Ensure fixer** replenishment rate is correct. Scratches on film. 1. Along the entire length of the film. 2. Along the direction of feed of film into processor (often with round areas of higher density). 1. Guide rails scratching film. Process another film with its long axis at right angles to the direction in which the previous film was processed. This will show whether the scratches occur before loading into processor or during processing. 2. Excessive pressure applied to film by fingers when inserted into feed slot of processor. * : When filling a processor with developer and fixer solution always mix and install fixer before developer to avoid fixer splashing into developer. Always rinse developer tank and rollers thoroughly with water after installing fixer before installing developer. Use separate mixing tanks. ** : The condition of a fixer can be judged by its silver content. Normally the silver concentration should not exceed 4 g/l. If it is too high this indicates too low a rate of replenishment. Silver concentration can be measured by silver test strips available from various laboratory chemical suppliers or from Merck. Page 5 / 6

X. STORAGE Liquid developer and fixer concentrates should be stored above 5 C to prevent crystallisation. Storage temperature above 25 C will cause premature ageing. XI. HANDLING PROCESSING SOLUTIONS All photographic processing solutions can exert harmful effects when brought into contact with human tissue to a greater or lesser extent depending on the nature of the solution and its concentration. All users of such solutions should exercise the greatest care to avoid the chemicals contacting the skin, eyes or other parts of the body. Always wear resistant gloves and effective eye protection. In case of accidental contact with processing solutions wash the affected part with plenty of clean cold running water. Wash with an acidic soap and rinse thoroughly with water. Consult a medical doctor. Some photographic solutions produce irritating vapours therefore thorough ventilation is essential. Do not inhale air above processing solutions. Always read the hazard information on the packs of solution concentrate before attempting to handle the solutions. Page 6 / 6