No: /16 rev. 1 Installation Instructions Instructions d Installation Instrucciones de Instalación UNIT DESCRIPTION

Similar documents
No: /18 rev. 1 Installation Instructions Instructions d Installation Instrucciones de Instalación

Installation Instructions

No: /16 rev. 1 Installation Instructions Instructions d Installation Instrucciones de Instalación DESCRIPTION

No: /17 rev. 1 Installation Instructions Instructions d Installation Instrucciones de Instalación

No: /17 rev. 1 Installation Instructions Instructions d Installation Instrucciones de Instalación

CX-100. Installation Instructions. PIR Occupancy Sensor SPECIFICATIONS

No: /17 rev. 1 Installation Instructions Instructions d Installation Instrucciones de Instalación

Installation Instructions

with Light Level, Isolated Relay and Manual On features

Installation Instructions

Installation Instructions

v3 360 Passive Infrared Line Voltage Occupancy Sensor

LOAD AWG Solid CU Wire Only LINE NEUT FSP-211. High/Low PIR Occupancy Sensor 230 VAC, 50 Hz 1200W max ballast 5E4

O ccupancy and Light Level Sensor L ow Vo l tage Ceiling Fixture Mount

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE WITH BLUETOOTH

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE FOR FLEXIBLE MOUNTING

Installing the FSP-211 Sensor in Light Fixture

SELECTABLE MODE HIGH/LOW/OFF PIR FIXTURE INTEGRATED INDOOR/OUTDOOR MOTION/PHOTO SENSOR

INSTRUCTIONS UNIVERSAL TRAY STAND - SMALL AASFT24 AASLH24 AASLP24

INSTRUCTIONS VERTICAL GROW SHELF SYSTEM VGS300 & VGS600

STL200/277 Installation Manual STL200/277

STL200/277 Installation Manual STL200/277

3000W multi Pir light controller

DESCRIPTION & OPERATION: PIR OCCUPANCY SENSOR MSWSFSP221B-D FEATURES:

STEALTH. STL200 Installation Manual. Specifications: STL200 STL200H STL200HB. Switching Capacity: 8 amps

Smart Task Motion Activated Task Light Installation Manual

CONTENTS OF THE BOX. *PIR sensor only **Dual Technology and PIR sensors only. Description PIR Ultrasonic Dual Technology

ASSEMBLY AND INSTALLATION INSTRUCTIONS

Mini Sensor. Outdoor Motion Sensor. Installation Manual

2 Pendant Adjustment. Pendant Slider Plate. 3/4 (19mm) IP, (29mm) O.D. Knockouts. 1/2 (13mm) IP, (22mm) O.D. Knockout

ASSEMBLY AND INSTALLATION INSTRUCTIONS

STEALTH. STL110 Installation Manual. Specifications: STL110 STL110HB STL110H STL110R. Switching Capacity:

3000W MULTI PIR LIGHT CONTROLLER

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

Eco-$mart, Inc. TOLL FREE:(888) FAX:(941)

Datasheet ENGLISH Halogen lamp 120W with motion sensor ( ) Halogen lamp 400W with motion sensor ( )

Infrared Wall Mount Occupancy Sensor

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

Wireless Occupancy Sensor User Guide

High/Low Bay Passive Infrared Occupancy Sensor

Important Safety Instructions

WATTSTOPPER OEM SENSOR GUIDE INTEGRATED LIGHTING CONTROLS. designed to be better.

ASSEMBLY AND INSTALLATION INSTRUCTIONS

ASYX 2.0 S3-S4-L3-L4-L5-L6 Wall Installation Instructions

FFLED18 INSTALLATION INSTRUCTIONS

SmartBox RAB. Installation Manual. Outdoor Motion Sensor. It s easy to add. motion detection to all your outdoor lights! Contents.

INSTALLATION MANUAL PBC-UMS

Technical Application Guide

High Bay Occupancy Sensor for Use with Electronic Ballast HID Luminaires

Dual Technology Wall Mount Occupancy Sensor

Smart Post RAB. Installation Manual. Outdoor Motion Sensor. It s easy to add. motion detection to your post lantern! Contents.

INSTALLATION MANUAL PBL-UMP

Dual Technology Wall Mount Occupancy Sensor

Tuff Dome. Installation Manual. vandal resistant. Outdoor Motion Sensor. Contents. Specifications. Switching Capacity:

User Guide Guide de l utilisateur Guía del Usuario

ROUND LIGHTPLANE 1 3D FLUSH

PARTS INCLUDED TOOLS & PARTS NEEDED Do not mount on vibrating surfaces. appro to 2.5 meters 12M

INSTALLATION INSTRUCTION Adjustable Spot - Endurance Sign Lighting

INSTALLATION INSTRUCTION

Instruction Sheet. VDM Series FIXED & TILT WALL MOUNT

Installation Manual. Specifications: Cautions: TURN OFF ALL POWER AT CIRCUIT BREAKER / FUSE PANEL.

SUPERPLANE 2.5 INSTALLATION INSTRUCTIONS WALL/SURFACE BACK MOUNT. A nd Avenue, Unit 1 Oakland,

Installation Instructions

Dialight Daylight Harvesting Sensor User Guide

Instruction Sheet VDM-200-T. Tilt Wall Mount

Installation Instructions SKU# , Rated Voltage V~ 50Hz

Tilting, Swiveling & Rotating Flat Panel Wall Mount

Instruction Sheet. VDM Series. Tilt Low Profile Mount

Universal TechBox Series

INSTALLATION INSTRUCTION Accent

A-dec 574L and 575L Dental Lights on a Cabinet or Wall INSTALLATION GUIDE

INSTALLATION INSTRUCTION Grand Accent

INSTALLATION INSTRUCTIONS SUPERPLANE 4 WALL MOUNT. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

FSP-211 DIGITAL HIGH/LOW PIR FIXTURE INTEGRATED SENSOR

FIXTURE INTEGRATED DAYLIGHT DIMMING PHOTOSENSOR

INSTALLATION INSTRUCTION Accent

Tilting & Swiveling Plasma/LCD Flat Panel Wall Mount Installation Guide Model: A380SM

DLA-E (Philips EvoKit) The DLA-E is designed to install in the mounting slot of the Philips EvoKit SR retrofit kit.

SUPERPLANE TM 4 RECESSED SP4R

INSTALLATION INSTRUCTION Accent

Instruction Sheet. VDM Series FIXED & TILT WALL MOUNT

Round or Square Type IC Wall Wash Housing with Lamp for Flangeless Trims

L DN 2810 FL DE 3925 L DN 2810 FL PIR DE 3925 L DN 5630 FL DE 3925 L DN 5630 FL PIR DE 3925 L DN 9850 FL DE 3925 L DN 9850 FL PIR DE 3925

Dual Technology Ceiling Mount Sensor

EBDSM-PRM Product Guide

Articulating TV/Monitor Grommet/Clamp Desk Mount Model: DE300S (Butterfly Series)

Installation Instructions (For Dealer or Contractor)

AUC Cell Assembly Torque Stand. User Manual

Universal Projector Ceiling Mount Model: DPM-45

Line volt rail & fixtures. Low volt quick connect fixtures with transformers

A-dec 6300 Ceiling-Mount Dental Light INSTALLATION GUIDE

Occupancy Sensors for High-Bay Applications

Item No: MIN :2.95in/75MM MAX:15.75in/400MM MAX: n

Quick Start Guide. Contents

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE LED SURFACE AMBIENT LUMINAIRE FACTORY SETTINGS. Configuration Value

NOVA-EXT Versatile Projector Mount Model: NOVA-EXT

BLUEMOTION UXP, CDP, SD

Comfort 10S Wall Hardwire Installation and Operations Manual

Multiples EM_ 1.4. Install 1X1/1X2/1X3/1X4 Housings. Installation Instructions for. This product is suitable for indoor locations.

Full-Motion TV Mount - 47" to 90" Installation Guide

Transcription:

Wattstopper Low Voltage Outdoor Motion Sensor No: 24260 09/16 rev. 1 Installation Instructions Instructions d Installation Instrucciones de Instalación Catalog Number Numéro de Catalogue Número de Catálogo: EW-205-24 Country of Origin: Made in China Pays d origine: Fabriqué en Chine País de origen: Hecho en China Box Contents One (1) EW-205-24 Accessory bag: Cover plate for 4 round outdoor junction box, with two cover plate attachment hole plugs, cover plate gasket, cover plate screws & screw covers (4 ea), lens mask, wire nuts (3) Installation instructions SPECIFICATIONS Voltage: EW-205-24... +24VDC Current Consumption...7mA Power Supply...Wattstopper Power Pack or DM-105 module B Series power packs supply power for up to 11 sensors. BZ Series power packs supply power for up to 15 sensors. DM-105 HID Bi-Level control module supplies power for up to two sensors. DM-115-WP Outdoor HID Bi-Level control module supplies power for up to two sensors. Coverage...270 Time Delay Adjustment...12sec. 16min. Light Level Adjustment... 0.5FC 200FC Operating Temperature...-40 to 130 F (-40 to 55 C) Mountable Locations... Pole, wall, ceiling or under eaves IEC-IP-55 Raintight Rated U.S.Patents: 4,787,722; 5,640,113 Please read all of the installation instructions before installing this product. UNIT DESCRIPTION The EW-205 sensor is an outdoor passive infrared (PIR) motion sensor rated for wet conditions. It installs onto a standard round outdoor junction box using the supplied junction box cover plate. The EW-205 sensor uses advanced PIR technology and a superior lens design to detect motion. PIR sensing is passive, and detects the difference between infrared energy in motion and the background space. The EW-205 sensor provides a +24VDC control output upon motion detection. This output can be connected to a WattStopper power pack for on/off lighting control, or to a WattStopper DM-105 or DM-115-WP Outdoor HID Bi-Level control module for high/low control. COVERAGE PATTERN Coverage is shown as tested in a controlled setting with the unit mounted at 8 ft at a 10 tilt from the horizontal surface. The actual outside coverage pattern may vary substantially at the specific installation site and is dependent on several factors including weather conditions, external light sources, mounting height and sensor tilt. Coverage adjustment: The front of the sensor housing can be moved up and down for easy coverage adjustment.

COVERAGE PATTERN (CONT D) 90 Top View Masking: Opaque adhesive tape is supplied so that sections of the sensor s lens can be masked to restrict coverage in unwanted areas. EW-205-24 270 coverage 8ft (2.4m) Side View 9.5ft (3m) 25ft (8m) 52.5ft (16m) MOTION SENSOR PLACEMENT Mounting Options Install onto a standard 4 round outdoor junction box. Mount to a flat, stable, vibration-free surface. Mount vertically or horizontally, usually to a wall, ceiling or under an eave. Careful consideration must be given to sensor placement. PIR sensors detect the difference between infrared energy in motion and the background space. To be detected, a person or vehicle must be within the sensor s coverage pattern and have an unobstructed view of the sensor. Horizontally Mounted: For horizontal mounting, such as under eaves, rotate the sensor housing as shown in the diagrams below. Make sure that the gasket is seated properly. 1 2 3 Loosen the two screws at the back of the sensor. Rotate the sensor housing 180. Replace and tighten the screws. Vertically Mounted: The sensor comes assembled and ready for vertical cover plate mounting, as shown in the illustration below. Attach mounting post to the cover plate: Make sure that the O-ring is on the threaded end of the mounting post before installing. O-ring Lightly screw the mounting post into the cover plate by rotating the sensor. Adjust the sensor to the desired angle, then tighten the locking ring. Locking ring and collar must be securely seated against the cover plate locking ring. 2

MOUNTING AND SENSOR POSITIONING GUIDELINES WARNING: LAMP BULB MUST BE 1/2 INCH OR MORE FROM SENSOR HOUSING Mount to flat, stable, vibration-free surface Avoid runoff; sheltered locations preferred Mount motion sensor level Install sensor no higher than 20 from ground Aim motion sensor downward to limit sensing Do not mount by vents or above lamps 3

The EW-205-24 can be powered from either a Wattstopper Power Pack, or a Wattstopper HID Dimming Module. Each Wattstopper B series power pack can supply power for up to 11 sensors. Each Wattstopper BZ series power pack can supply power for up to 15 sensors. Each DM-105 or DM-115-WP module can supply power for up to 2 sensors. When power is initially applied to the sensor, or following restoration from a power failure, the lights will turn on. If no motion is detected by the sensor, the lights will remain on/high for for approximately one minute and then turn off/low. (See Security Override). Sensor Wire Functions The EW-205-24 has 3 wire connections to the power pack or DM-105 or DM-115 -WP module. See the descriptions and wiring diagrams that follow for connections to each specific power source. RED: +24VDC input to sensor BLACK: Common BLUE: +24VDC control output from sensor WIRING AND INSTALLATION WARNING: TURN POWER OFF AT THE CIRCUIT BREAKER BEFORE INSTALLING SENSOR.SENSOR MUST BE INSTALLED BY QUALIFIED PERSONNEL ONLY. Connecting to a Power Pack Wire the sensor to a WattStopper power pack as shown: RED wire from sensor to RED wire on power pack. BLACK (common) wire from sensor to BLACK wire on power pack. BLUE wire from sensor to BLUE wire on power pack. Connecting to a DM-105 HID Dimming Module Wire the sensor to a WattStopper DM-105 as shown below: RED wire from sensor to terminal 1 (+24VDC Output) on the DM-105. BLACK wire (common) from sensor to terminal 2 on the DM-105. BLUE wire from sensor terminal 3 (Control In) on the DM-105. 4

Connecting to a DM-115-WP HID Dimming Module Wire the sensor to a WattStopper DM-115-WP as shown below: RED wire from sensor to RED wire from the DM-115-WP cable. BLACK (common) wire from sensor to BLACK wire from the DM-115-WP cable. BLUE wire from sensor to WHITE wire from the DM-115-WP cable. TESTING AFTER INSTALLATION To facilitate coverage testing, the factory setting for Time Delay is 12 seconds, and the Light Level is at Maximum. If you want to test a sensor for intended detection or operation: 1. Make sure that the time delay is set to 12 seconds and the light level is set to maximum (clockwise to the sun icon. The dials are located on the bottom of the sensor.) 2. Adjust sensor and lamp holders to the desired position. 3. Ensure that power has been restored to the sensor. 4. Move into the location to be tested; lights should turn on (or switch to high if connected to a DM-105 or DM-115-WP HID Bi-Level control module). Stand still. In about 12 seconds the lights should turn off (or switch to low if connected to a DM-105 or DM-115- WP HID Bi-Level control module). Move or walk and the lights should turn on/high. Repeat this process to test other locations. Make sensor coverage adjustments as needed (see Coverage adjustment and Masking, page 2). TE: When power is restored to the sensor, the lights will turn on for approximately one minute. (See Security Override.) TE: If the lights do not turn on with movement in the area after they have turned off in step 4, the level of daylight may be too high and the sensor s light level adjustment is keeping the sensor inactive. Wait until daylight levels have reduced before testing again. 5. See Dial Adjustments, for guidelines to adjust the time delay and light level to the desired settings for operation. DIAL ADJUSTMENTS Time Delay and Light Level control dials are located on the bottom of the sensor. 1. Adjust Time Delay: The time delay is the amount of time that elapses before lights turn off since the sensor last detected motion. This can be set from 12 seconds to 16 minutes. For normal operation, the time delay should be set to 1 minute or more. In areas where there is mostly walk through movement, the time delay amount can be low. In areas where people may stop and remain for periods of time, the time delay should be set to a higher amount, preferably 16 minutes. 2. Adjust Light Level: Turning the light level adjustment dial raises or lowers a daylight level in the sensor. When the light of the day rises above this set level, the sensor becomes inactive; this keeps the lights off when there is enough daylight present. We suggest initially setting the light level adjustment to half way between minimum and maximum. If a different setting is desired after installation, then follow the Making Changes procedures. TIME DELAY DIAL Minimum: 12 seconds Maximum: 16 minutes LIGHT LEVEL DIAL Minimum = Maximum= 5

MAKING CHANGES If you want the lights to turn on/high sooner turn the light level dial toward the sun icon, as desired; this raises the light level setting. (Remember, the sensor must detect motion for lights to turn on.) The lights turn on sooner in the evening. The lights stay on longer in the morning. If you want the lights to turn on later turn the light level dial toward the moon icon, as desired; this lowers the light level setting. (Remember, the sensor must detect motion for lights to turn on.) The lights turn on later in the evening. The lights turn off sooner in the morning. Notes: When testing adjustments, make sure not to block any of the light that is reaching the sensor or reflect any light into the sensor s lens. The sensor requires about 5 seconds for light level adjustments to take effect. This feature prevents the lights from turning on/high and off/low with quick light reflections, from car windows for example. The sensor will not turn lights off/low until no motion is detected and the time delay elapses. SECURITY OVERRIDE The EW sensors have an override-on feature which allows lights to be turned on for the set time delay period. If there is an installed switch turning the switch off then on, turns the lights on. If no motion is detected by the sensor, the lights will remain on for approximately one minute and then turn off. This will also happen when power is restored after a power outage. TE: If the lights do not turn on, the sensor may be inactive due to the daylight level. Turn the switch off for 5 seconds, then turn it on. The lights should turn on as described above. TROUBLESHOOTING Lights do not turn off/low: 1. The sensor may be detecting movement outside the desired coverage area. The sensor s lens may need to be masked to block unwanted coverage (see Masking). If this does not solve the problem, see step 2. 2. Test to see that the sensor is operating properly. Set the time delay to minimum (12 seconds). Remain still, or move out of range of the sensor. If there is no movement in the coverage area, the sensor should turn lights off/low in 12 seconds. Reset the time delay to the desired value. 3. If the lights do not turn off/low, have a person qualified to check high voltage connections verify that the sensor and lighting are wired correctly (see Wiring and Installation). CAUTION: Make sure power is turned off at the circuit breaker before checking wiring. 4. If the sensor is wired correctly, call our Technical Support number. Lights turn on/high when there is sufficient daylight: Decrease the light level setting, as desired (counterclockwise toward the moon icon, see Dial Adjustments). Lights do not turn on/high: 1. If there is a controlling switch installed, make sure that it is turned on. 2. If the lights do not turn on/high when lights are needed increase the light level setting, as desired (clockwise toward the sun icon, see Dial Adjustments). 3. Have a person qualified to check high voltage connections verify that the sensor and lighting are wired correctly (see Wiring and Installation). CAUTION: Make sure power is turned off at the circuit breaker before checking wiring. 4. If the sensor is wired correctly, call our Technical Support number. 6

Catalog # EW-205-24 B230E-P B347D-P ORDERING INFORMATION Description +24VDC, 270 Outdoor PIR Motion Sensor, includes cover plate Power Pack: 230VAC, 50/60Hz, 150mA 20A ballast/13a incandescent Power Pack: 347VAC, 60Hz, 150mA. 15A ballast BZ-50 Power Pack: 120/277VAC, 50/60Hz, 20A ballast or incandescent BZ-150 BZ-200 BZ-250 BZ-250-347 DM-105 DM-115-WP Power Pack: 120/277VAC, 50/60Hz, 20A ballast or incandescent, with Hold-On and Hold-Off capability Power Pack: 120/277VAC, 50/60 Hz, 20A Ballast/ELV/MLV/Incandescent/LED, 16A, E-Ballast/CFL/Plug Load Power Pack: 120/277VAC, 50/60 Hz, 20A, Ballast/ELV/MLV/Incandescent/LED, 16A E-Ballast/CFL/Plug Load, with Hold-On/Hold-Off capability Power Pack: 120/347VAC, 50/60 Hz, 16A Ballast/ELV/MLV/Incandescent/LED/ E-Ballast/CFL, 15A Plug Load, with Hold-On/Hold-Off capability HID Bi-Level Control Module Outdoor HID Bi-Level Control Module When ordering, add (-W) for Arctic White or (-G) for Architectural Gray to catalog numbers. THIRD-PARTY ORDERING INFORMATION Additional color-matched lamp holder accessories are available through your local distributor, or for further assistance call CANLET at 1-888-461-5307 Outdoor incandescent lamp holders Shrouds for PAR 20 & PAR 38 lamps Round outdoor junction boxes & cover plates 7

WARRANTY INFORMATION INFORMATIONS RELATIVES À LA GARANTIE INFORMACIÓN DE LA GARANTÍA Wattstopper warranties its products to be free of defects in materials and workmanship for a period of five (5) years. There are no obligations or liabilities on the part of Wattstopper for consequential damages arising out of, or in connection with, the use or performance of this product or other indirect damages with respect to loss of property, revenue or profit, or cost of removal, installation or reinstallation. Wattstopper garantit que ses produits sont exempts de défauts de matériaux et de fabrication pour une période de cinq (5) ans. Wattstopper ne peut être tenu responsable de tout dommage consécutif causé par ou lié à l utilisation ou à la performance de ce produit ou tout autre dommage indirect lié à la perte de propriété, de revenus, ou de profits, ou aux coûts d enlèvement, d installation ou de réinstallation. Wattstopper garantiza que sus productos están libres de defectos en materiales y mano de obra por un período de cinco (5) años. No existen obligaciones ni responsabilidades por parte de Wattstopper por daños consecuentes que se deriven o estén relacionados con el uso o el rendimiento de este producto u otros daños indirectos con respecto a la pérdida de propiedad, renta o ganancias, o al costo de extracción, instalación o reinstalación. No. 24260 09/16 rev. 1 Copyright 2016 Legrand All Rights Reserved. Copyright 2016 Tous droits réservés Legrand. Copyright 2016 Legrand Todos los derechos reservados. 800.879.8585 www.legrand.us/wattstopper