Installation Instructions

Similar documents
No: /18 rev. 1 Installation Instructions Instructions d Installation Instrucciones de Instalación

No: /16 rev. 1 Installation Instructions Instructions d Installation Instrucciones de Instalación UNIT DESCRIPTION

Installation Instructions

Installation Instructions

with Light Level, Isolated Relay and Manual On features

CX-100. Installation Instructions. PIR Occupancy Sensor SPECIFICATIONS

Installation Instructions

v3 360 Passive Infrared Line Voltage Occupancy Sensor

O ccupancy and Light Level Sensor L ow Vo l tage Ceiling Fixture Mount

LOAD AWG Solid CU Wire Only LINE NEUT FSP-211. High/Low PIR Occupancy Sensor 230 VAC, 50 Hz 1200W max ballast 5E4

CONTENTS OF THE BOX. *PIR sensor only **Dual Technology and PIR sensors only. Description PIR Ultrasonic Dual Technology

STL200/277 Installation Manual STL200/277

STL200/277 Installation Manual STL200/277

ASSEMBLY AND INSTALLATION INSTRUCTIONS

STEALTH. STL200 Installation Manual. Specifications: STL200 STL200H STL200HB. Switching Capacity: 8 amps

ASSEMBLY AND INSTALLATION INSTRUCTIONS

SELECTABLE MODE HIGH/LOW/OFF PIR FIXTURE INTEGRATED INDOOR/OUTDOOR MOTION/PHOTO SENSOR

STEALTH. STL110 Installation Manual. Specifications: STL110 STL110HB STL110H STL110R. Switching Capacity:

Smart Task Motion Activated Task Light Installation Manual

Mini Sensor. Outdoor Motion Sensor. Installation Manual

Installing the FSP-211 Sensor in Light Fixture

3000W multi Pir light controller

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE WITH BLUETOOTH

Eco-$mart, Inc. TOLL FREE:(888) FAX:(941)

ASSEMBLY AND INSTALLATION INSTRUCTIONS

3000W MULTI PIR LIGHT CONTROLLER

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE FOR FLEXIBLE MOUNTING

SmartBox RAB. Installation Manual. Outdoor Motion Sensor. It s easy to add. motion detection to all your outdoor lights! Contents.

Tuff Dome. Installation Manual. vandal resistant. Outdoor Motion Sensor. Contents. Specifications. Switching Capacity:

High Bay Occupancy Sensor for Use with Electronic Ballast HID Luminaires

High/Low Bay Passive Infrared Occupancy Sensor

FFLED18 INSTALLATION INSTRUCTIONS

DESCRIPTION & OPERATION: PIR OCCUPANCY SENSOR MSWSFSP221B-D FEATURES:

Smart Post RAB. Installation Manual. Outdoor Motion Sensor. It s easy to add. motion detection to your post lantern! Contents.

Dual Technology Wall Mount Occupancy Sensor

Datasheet ENGLISH Halogen lamp 120W with motion sensor ( ) Halogen lamp 400W with motion sensor ( )

Technical Application Guide

Installation Manual. Specifications: Cautions: TURN OFF ALL POWER AT CIRCUIT BREAKER / FUSE PANEL.

Dual Technology Wall Mount Occupancy Sensor

Infrared Wall Mount Occupancy Sensor

Wireless Occupancy Sensor User Guide

FSP-211 DIGITAL HIGH/LOW PIR FIXTURE INTEGRATED SENSOR

L DN 2810 FL DE 3925 L DN 2810 FL PIR DE 3925 L DN 5630 FL DE 3925 L DN 5630 FL PIR DE 3925 L DN 9850 FL DE 3925 L DN 9850 FL PIR DE 3925

SMARTBULLET SMSBULLET2X12

FFLED18 INSTALLATION INSTRUCTIONS

DLA-E (Philips EvoKit) The DLA-E is designed to install in the mounting slot of the Philips EvoKit SR retrofit kit.

2 Pendant Adjustment. Pendant Slider Plate. 3/4 (19mm) IP, (29mm) O.D. Knockouts. 1/2 (13mm) IP, (22mm) O.D. Knockout

1010/T Series Incandescent Illuminator

Phase-sequence Phase-loss Relay

INSTALLATION MANUAL PBC-UMS

Dialight Daylight Harvesting Sensor User Guide

INSTALLATION MANUAL PBL-UMP

Dual Technology Ceiling Mount Sensor

USER S MANUAL. NX-5 Series. Power Supply Built-in Compact Multi-voltage Photoelectric Sensor

Round or Square Type IC Wall Wash Housing with Lamp for Flangeless Trims

40 mm Beam Pitch General Purpose Area Sensor NA40 SERIES

EBDSM-PRM Product Guide

12 24 VAC/VDC ±10% (inhibited when voltage is applied) min. pulse width duration = 50 ms. Normal mode or Background Analysis mode

18W Nightsensor Bulkhead

Universal Projector Ceiling Mount Model: DPM-45

Line volt rail & fixtures. Low volt quick connect fixtures with transformers

Heritage Solar Lamp Post

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

SmartBox. Outdoor Motion Sensor. Installation Manual

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

WALL LANTERN ITEM # MODEL #LWS1204C ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

QuadroMAX. Installation Manual. QM Series. LED Outdoor Lighting Fixtures REV: 3/22/16

Ultraminiature Photoelectric Switches with Self-contained Amplifier

Occupancy Sensors for High-Bay Applications

DAWN TO DUSK SENSOR OWNER S MANUAL

NA1-11. Small / Slim Object Detection Area Sensor. Cross-beam scanning system to detect slim objects

Data sheet. Function description. Benefits

SMARTRIPPLE Geyser Load Control Timer

40 mm Beam Pitch General Purpose Area Sensor. Failure monitoring

Energy Saving Module (HG-ESM-01)

Installation Manual. The STEALTH 360 is the most reliable and technically advanced motionactivated

A-dec 574L and 575L Dental Lights on a Cabinet or Wall INSTALLATION GUIDE

General Installation Instructions

Installation Instructions

Custom Pendant- Hardwire Assembly and Installation Instructions

PRC-LA Installation Guide

MaxLite Linear Strip ECO Series

PARTS INCLUDED TOOLS & PARTS NEEDED Do not mount on vibrating surfaces. appro to 2.5 meters 12M

TekLink TL100 with Passive Infrared Sensing System Overview

Pre-wired Photomicrosensor with Amplifier and Cable EE-SPW321/421 Compact, Thin-profile Photomicrosensor with special amplifier.

Emitting and receiving element pitch: 10 mm in

Sensing method Appearance Sensing distance Operation mode Model. Emitter E3S-2LE4 Through-beam *1. 2 m. 0.1 to 2 m. 300 mm. 2 m

Indoor Contact Input Photosensor

Important Safety Instructions

Sealed Interface Control: EC20300

NA DigiParts GmbH. Small / Slim Object Detection Area Sensor

INSTALLATION INSTRUCTIONS SMALL FLAT PANEL ADJUSTABLE PITCH WALL MOUNT Model: FTR Series

Type Sealing Poles Contact configuration Rated voltage Model. Type LED indicator Poles Rated voltage Model

NA1-11. Small / Slim Object Detection Area Sensor. Cross-beam scanning system to detect slim objects. Letters or business cards detectable!

Installation Manual. The STEALTH 360 is the most reliable and technically advanced motionactivated

Installation Manual. Specifications: Cautions: Switching Capacity: 360º below and to the sides

Installation Instructions SKU# , Rated Voltage V~ 50Hz

Specifications. Important Safety Information

FIXTURE INTEGRATED DAYLIGHT DIMMING PHOTOSENSOR

Label Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor

Transcription:

TECH SUPPORT The Watt Stopper, Inc. 2800 De La Cruz Blvd. Santa Clara, CA 95050, USA Tel: 1(800)879-8585 1(972)578-1699 Fax: 1(972)422-1311 www.wattstopper.com Outdoor 180 & 270 PIR Motion s Model#s: EW-100-120 EW-105-120 EW-200-120 EW-205-120 EW-100-277 EW-105-277 EW-200-277 EW-205-277 SPECIFICATIONS Voltage: EW-100-120, EW-105-120, EW-200-120, EW-205-120........ 120VAC, 60Hz EW-100-277, EW-105-277, EW-200-277, EW-205-277........ 277VAC, 60Hz Mountable Locations......................... Wall, ceiling or under eaves Operating Temperature...................... -40 to 130 F (-40 to 55 C) Lens Coverage: EW-100 & EW-105.......................................... 180 EW-200 & EW-205.......................................... 270 Load Ratings...................... 0 1000W ballast or tungsten @120VAC 0 1000W ballast @277VAC Motor Load:........................................ 1/6 HP @120VAC 1/3 HP @277VAC Current Consumption Without Isolated Relay................................. 22 ma max. With Isolated Relay................................... 34 ma max. Time Delay Adjustment................................ 12sec. 16min. Light Level Adjustment................................. 0.5FC 200FC Isolated Relay on EW-100 & EW-200 (both -120 & -277 models) Normally Open & Normally Closed contacts. Isolated Relay Rating:............................... 1A @ 30VAC/DC UL 773A Raintight Rated IEC-IP-55 Rated Installation Instructions Putting a Stop to Energy Waste 00335r1 5/99 Santa Clara, CA 95050 (800) 879-8585 U.S.Patents: 4,787,722 5,640,113

CONTENTS Page: SPECIFICATIONS............................................... Front Cover BOX CONTENTS................................................... 1 UNIT DESCRIPTION................................................. 2 COVERAGE PATTERNS.............................................. 2 Masking........................................................ 2 Coverage adjustment.............................................. 2 MOTION SENSOR PLACEMENT........................................ 3 Mounting options................................................. 3 Mounting and sensor positioning guidelines............................. 4 WIRING AND INSTALLATION......................................... 5 & 6 TESTING AFTER INSTALLATION........................................ 7 DIAL ADJUSTMENTS.............................................. 7 & 8 Adjust Time Delay................................................. 7 Adjust Light Level............................................... 7 & 8 SECURITY OVERRIDE............................................... 9 TROUBLESHOOTING................................................ 9 ORDERING INFORMATION........................................... 10 WARRANTY INFORMATION........................................... 10 TECH SUPPORT................................................ Back Cover BOX CONTENTS CAUTION READ ALL OF THE INSTALLATION INSTRUCTIONS BEFORE INSTALLING THIS PRODUCT. THIS UNIT USES HIGH VOLTAGE. IT SHOULD ONLY BE INSTALLED BY QUALIFIED PERSONS THAT ARE THOROUGHLY FAMILIAR WITH PROPER SAFETY PROCEDURES AND ELECTRICAL AND BUILDING CODES FOR THE INSTALLATION LOCATION. WARNING: TO AVOID FIRE, SHOCK, ELECTROCUTION, OR DEATH TURN OFF POWER AT THE CIRCUIT BREAKER OR FUSE BOX AND TEST TO ENSURE POWER IS OFF BEFORE WIRING. One (1) EW-100-120, EW-105-120, EW-200-120, EW-205-120, EW-100-277, EW-105-277, EW-200-277 or EW-205-277 Accessory bag: - Cover plate for 4" round outdoor junction box, with two cover plate attachment hole plugs, cover plate gasket, cover plate screws & screw covers (4 ea), lens mask, wire nuts (3) Installation instructions UNIT DESCRIPTION The EW sensors are outdoor passive infrared (PIR) motion sensors rated for wet conditions. They are preassembled with a junction box cover and are ready to install to standard round outdoor junction boxes. The EW sensors utilize advanced PIR technology and a superior lens design to detect motion. PIR sensing is passive, and detects the difference between infrared energy in motion and the background space. TOP 8ft (2.4m) SIDE 9.5ft (3m) 25ft (8m) EW-100, EW-105 180 coverage 52.5ft (16m) 90 TOP 8ft (2.4m) SIDE lens COVERAGE PATTERNS Coverages shown are maximum and represent coverage for walking motion. Actual coverages will vary depending on mounting heights, ambient temperature and weather conditions. 9.5ft (3m) 25ft (8m) EW-200, EW-205 270 coverage 52.5ft (16m) housing Cover plate Masking: Opaque adhesive tape is supplied so that sections of the sensor s lens can be masked to restrict coverage in unwanted areas. Coverage adjustment: The front of the sensor housing can be moved up and down for easy coverage adjustment. Attachment holes with plugs 1 Call 1(800) 879-8585 or 1(972)578-1699 For Technical Support 2

MOTION SENSOR PLACEMENT Careful consideration must be given to sensor placement. PIR sensors detect the difference between infrared energy in motion and the background space. To be detected, a person or vehicle must be within the sensor s coverage pattern and have an unobstructed view of the sensor. Mounting options Install onto a standard 4" round outdoor junction box. Mount to a flat, stable, vibration-free surface. Mount vertically or horizontally, usually to a wall, ceiling or under an eave. Vertically mounted: The sensor comes assembled and ready for vertical cover plate mounting, as shown below. Mounting and sensor positioning guidelines Mount to flat, stable, vibration-free surface Avoid runoff; sheltered locations preferred Mount motion sensor level Install lamps above sensor to avoid heat effects Horizontally mounted: For horizontal mounting, such as under eaves, rotate the sensor housing as shown in the diagrams below. Make sure that the gasket is seated properly. 2 1 3 Aim motion sensor downward to limit sensing Do not mount by vents or above lamps Loosen the two screws at the back of the sensor. Rotate the sensor housing 180. Replace and tighten the screws. 3 Call 1(800) 879-8585 or 1(972)578-1699 For Technical Support 4

WIRING AND INSTALLATION CAUTION TURN POWER OFF AT THE CIRCUIT BREAKER BEFORE INSTALLING SENSOR. SENSOR MUST BE INSTALLED BY QUALIFIED PERSONNEL ONLY. Wire connections for sensor (see instructions, page 6) Gasket IMPORTANT! thread wires through gasket before connecting To Controlled Loads Cover plate Attach cover plate assembly and gasket to the junction box with 4 screws and screw covers (supplied) IMPORTANT! Make sure that the gasket seats properly when attaching the cover plate WIRING AND INSTALLATION (continued) Wire the sensor as shown below: BLACK wire from sensor to line voltage. WHITE wire from sensor to Neutral. RED wire is connected to lighting loads, if used, as shown (see diagram above and below), not to exceed load rating (see Specifications, front cover). Isolated Relay (see Specifications, front cover, for rating). Connect the wires necessary to the application that requires this output. - ORANGE (Common) (must be used for proper operation). - GREEN (Normally Closed) (Open when occupancy is detected). - YELLOW (Normally Open) (Closed when occupancy is detected). Multiple sensors (optional) connected in parallel Red (Load) 4" round outdoor junction box RED BLACK WHITE Line Switch (optional) Red (Load) Neutral TE: Weather proof caulking may be required around junction box and cover plate to provide a weatherproof seal in some installations. Wire connections when attaching lamp holders (Isolated relay wires not shown) Gasket IMPORTANT! thread wires through gasket before connecting To additional Controlled Loads (optional) Cover plate Isolated Relay Wires (N/O, COMMON, N/C) Model #s: EW-100 & EW-200 Attach cover plate assembly and gasket to the junction box with 4 screws and screw covers (supplied) IMPORTANT! Make sure that the gasket seats properly when attaching the cover plate Isolated Relay Orange (Common) Green (Normally Closed) Yellow (Normally Open) Load Load Multiple loads (optional) connected in parallel Note: When power is restored to the sensor, the lights will turn on. If no motion is detected by the sensor, the lights will remain on for the set time delay period (or minimum of approximately one minute) and then turn off (see Security Override, page 9). 4" round outdoor junction box BLACK RED Lamp holder (CANLET lamp holder shown) WHITE TE: Weather proof caulking may be required around junction box and cover plate to provide a weatherproof seal in some installations. 5 Call 1(800) 879-8585 or 1(972)578-1699 For Technical Support 6

TESTING AFTER INSTALLATION To facilitate coverage testing, the factory setting for Time Delay is 12 seconds, and the Light Level is at Maximum. If you want to test a sensor for intended detection or operation: 1. Make sure that the time delay is set to 12 seconds and the light level is set to maximum (clockwise to the sun icon). (The dials are located on the bottom of the sensor.) 2. Adjust sensor and lamp holders to the desired position. 3. Ensure that power has been restored to the sensor. 4. Move into the location to be tested; lights should turn on. Stand still. In about 12 seconds the lights should turn off. Move or walk and the lights should turn on. Repeat this process to test other locations. Make sensor coverage adjustments as needed (see Coverage adjustment and Masking, page 2). Note: When power is restored to the sensor, the lights will turn on for the set time delay, or a minimum of approximately one minute (see Security Override, page 9). Note: If the lights do not turn on with movement in the area after they have turned off in step 4, the level of daylight may be too high and the sensor s light level adjustment is keeping the sensor inactive. Wait until daylight levels have reduced before testing again. 5. See Dial Adjustments, below, for guidelines to adjust the time delay and light level to the desired settings for operation. 2. Adjust Light Level (continued): Making Changes If you want the lights to turn on sooner turn the dial toward the sun icon, as desired; this raises the daylight level. (Remember, the sensor must detect motion for lights to turn on.) The lights turn on sooner in the evening The lights stay on longer in the morning If you want the lights to turn on later turn the dial toward the moon icon, as desired; this lowers the daylight level. (Remember, the sensor must detect motion for lights to turn on.) The lights turn on later in the evening The lights turn off sooner in the morning Notes: When testing adjustments, make sure not to block any of the daylight that is reaching the sensor or reflect any daylight into sensor s lens. The sensor requires about 5 seconds for light level adjustments to take effect. This feature prevents the lights from turning on and off with quick light reflections, from car windows for example. The sensor will not turn lights off until no motion is detected and the time delay elapses. DIAL ADJUSTMENTS Time Delay and Light Level control dials are located on the bottom of the sensor. 1. Adjust Time Delay: The time delay is the amount of time that elapses before lights turn off since the sensor last detected motion. This can be set from 12 seconds to 16 minutes. For normal operation, the time delay should be set to 1 minute or more. In areas where there is mostly walk through movement, the time delay amount can be low. In areas where people may stop and remain for periods of time, the time delay should be set to a higher amount, preferably 16 minutes. TIME DELAY DIAL MIN. SEC. 1 12 16 Minimum: 12 seconds Maximum: 16 minutes 2. Adjust Light Level: Turning the light level adjustment dial raises or lowers a daylight level in the sensor. When the light of the day rises above this set level, the sensor becomes inactive; this keeps the lights off when there is enough daylight present. We suggest initially setting the light level adjustment to half way between minimum and maximum. If a different setting is desired after installation, then follow the Making Changes procedures, next page. (continued next page) LIGHT LEVEL DIAL Minimum = Maximum = 7 Call 1(800) 879-8585 or 1(972)578-1699 For Technical Support 8

SECURITY OVERRIDE The EW sensors have an override-on feature which allows lights to be turned on for the set time delay period. If there is an installed switch turning the switch off then on, turns the lights on. If no motion is detected by the sensor, the lights will remain on for the set time delay period (or minimum of approximately one minute) and then turn off. This will also happen when power is restored after a power outage. Note: If the lights do not turn on, the sensor may be inactive due to the daylight level. Turn the switch off for 5 seconds, then turn it on. The lights should turn on as described above. TROUBLESHOOTING Lights do not turn off: 1. The sensor may be detecting movement outside the desired coverage area. The sensor s lens may need to be masked to block unwanted coverage (see Masking, page 2). If this does not solve the problem, see step 2. 2. Test to see that the sensor is operating properly. Set the time delay to minimum (12 seconds). Remain still, or move out of range of the sensor. If there is no movement in the coverage area, the sensor should turn lights off in 12 seconds. Reset the time delay to the desired value. - If the lights do not turn off, have a person qualified to check high voltage connections verify that the sensor and lighting are wired correctly (see Wiring and Installation, page 5 & 6). CAUTION: Make sure power is turned off at the circuit breaker before checking wiring. - If the sensor is wired correctly, call our Technical Support number. Lights turn on when there is sufficient daylight: 1. Decrease the light level setting, as desired (counterclockwise toward the moon icon) (see Dial Adjustments, page 7 & 8). Lights do not turn on: 1. If there is a controlling switch installed, make sure that it is turned on. 2. If the lights do not turn on when lights are needed increase the light level setting, as desired (clockwise toward the sun icon) (see Dial Adjustments, page 7 & 8). 3. Have a person qualified to check high voltage connections verify that the sensor and lighting are wired correctly (see Wiring and Installation, page 5 & 6). CAUTION: Make sure power is turned off at the circuit breaker before checking wiring. - If the sensor is wired correctly, call our Technical Support number. ORDERING INFORMATION Catalog # EW-100-120 EW-105-120 Description 120VAC, 60Hz, 180 Outdoor/Indoor PIR Motion with Isolated Relay, 120VAC, 60Hz, 180 Outdoor/Indoor PIR Motion, EWF-105-120 120VAC, 60Hz, 180 Outdoor PIR Motion, includes two lamp holders and cover plate EW-200-120 120VAC, 60Hz, 270 Outdoor/Indoor PIR Motion with Isolated Relay, EW-205-120 120VAC, 60Hz, 270 Outdoor/Indoor PIR Motion, EWF-205-120 120VAC, 60Hz, 270 Outdoor PIR Motion, includes two lamp holders and cover plate EW-100-277 277VAC, 60Hz, 180 Outdoor/Indoor PIR Motion with Isolated Relay, EW-105-277 277VAC, 60Hz, 180 Outdoor/Indoor PIR Motion, EW-200-277 277VAC, 60Hz, 270 Outdoor/Indoor PIR Motion with Isolated Relay, EW-205-277 277VAC, 60Hz, 270 Outdoor/Indoor PIR Motion, When ordering, add (-W) for Arctic or (-G) for Architectural Gray to catalog numbers. THIRD-PARTY ORDERING INFORMATION Additional color-matched lamp holder accessories are available through your local distributor, or for further assistance call CANLET at 1-888-461-5307. Outdoor incandescent lamp holders Shrouds for PAR 20 & PAR 38 lamps Round outdoor junction boxes & cover plates WARRANTY INFORMATION The Watt Stopper, Inc. warranties its products to be free of defects in materials and workmanship for a period of five years. There are no obligations or liabilities on the part of The Watt Stopper, Inc. for consequential damages arising out of or in connection with the use or performance of this product or other indirect damages with respect to loss of property, revenue, or profit, or cost of removal, installation or reinstallation. 9 Call 1(800) 879-8585 or 1(972)578-1699 For Technical Support 10