PSD-S AE SM DB/1

Similar documents
PSD-S CE-TM SPRING. Connection element with spring-cage terminal blocks for tube mounting. Data sheet. 1 Description

MINI MCR-SL-UI-I-LP-NC

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

Electronic Installation Buzzer

MINI MCR-SL-UI-f(-SP)

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

MINI-PS AC/24DC/1.3

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

This data sheet is only valid in association with the IL SYS INST UM E user manual.

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

TC ANT MOBILE... Mobile communication antennas and antenna cables. Data sheet _en_00. 1 Description

Traffic Lights/ Signal Beacons - 890/895/897/894/ families

PHOENIX CONTACT

PHOENIX CONTACT

Signal conditioner - MACX MCR-UI-UI-NC

MACX MCR-UI-UI-UP(-SP)(-NC)

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

5 years! Modular Housings. VariTrans P Warranty

Extract from the online catalog

Loud electronic horn High life duration up to 5,000 hrs TECHNICAL SPECIFICATIONS: PC, PC/ABS-Blend, grey Fixing:

EMD-FL-3V Phase Voltage Monitoring Relay INTERFACE. Data Sheet. Description

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

QUINT-PS-24DC/24DC/10

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable

370 SERIES SIGNAL TOWERS 370 SERIES Ø70

MCR-C-UI-UI-DCI. Extract from the online catalog. Order No.:

TRIO-PS-2G/1AC/24DC/5

PHOENIX CONTACT - 09/2009

M70LL Laser Distance Sensor

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

QUINT-PS AC/24DC/40

Online data sheet WT260-R260 W260 PRODUCT PORTFOLIO

XXXX e. X d.. X X X a

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Power consumption In operation At rest For wire sizing

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

MINI-PS AC/2X15DC/1

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from ND 15 mm qp 0,6 m3/h up to ND 40 mm qp 10 m3/h

QUINT-PS/1AC/24DC/10. Power supply unit. Data sheet. 1 Description

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

VariTrans P V. Safe and Sound.

QUINT-PS/ 3AC/24DC/10

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

QUINT-PS/ 3AC/24DC/40

PHOENIX CONTACT - 03/2007

Technical data sheet. Technical data. Safety notes

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

2-channel speed sensor GEL 248 Compact sensor with HTL-/TTL-output signals

Speed and Positioning Sensor GEL 2478

Liquid level monitoring relay CM-ENS.2x

Extract from the online catalog

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

XXXX e. X d.. X X X a

JUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program

DIGEM f 96 x 48 EK. Applications. Description

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Outside Temperature Sensors

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

Tangential Fans - Basic principles. Expertise, performance, innovation

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

QUINT-PS/ 1AC/24DC/20

Product Data Sheet 3252J/2H3PU

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Color control modes: RGB, RGBW, HSI, HSIC. Auto-addressing during set-up

PACT RCP-4000A-UIRO-Dxxx

WESAN WP E ELECTRONIC METER WOLTMAN

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

DSP AMPLIFIERS DI

Power supply CP-D 24/1.3

Power consumption In operation At rest For wire sizing

Universal/Standard Ku-band GaN 40W BUC MODEL No. NJT8371 series

CONTA-ELECTRONICS. Converter Units

PAL VERSION CEC-WP-PV49AB NTSC VERSION CEC-WP-NV49AB CEC-WP-C38 CEC-WP-C60 CEC-WP-CV48 CEC-WP-CV48A CEC-WP-E38 CEC-WP-E60 CEC-WP-EV48 CEC-WP-EV48A

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks

installation depth: 90 mm without plug-in terminal display flashing at threshold exceedance / threshold undershooting

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O

Power consumption In operation At rest For wire sizing

IB IL 24 PWR IN/PS IB IL 24 PWR IN/PS-PAC

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Online data sheet WS/WE260-R270 W260 PRODUCT PORTFOLIO

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Product Data Sheet 3254 J/2H3P

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

Power supply CP-E 24/2.5

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

CYHCS-RC2S Split Core Hall Effect DC Current Sensor

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Theta 20A / 20V. Technical Data Sheet. Special Features

Transcription:

Siren element, 8 tones, 24 V AC/DC, max. 100 db(a) Data sheet 7944_en_02 PHOENIX CTACT 2015-05-04 1 Description This audible signal element is designed as a component of a modular signal tower. According to your requirements, a signal tower may comprise any combination of up to five signal elements. You may use up to five optical signal elements or up to four optical and one audible signal element. An audible signal element can be used as top element only. A bayonet locking system establishes the mechanical and electrical connection between the elements. Connection elements with spring-cage or screw connection can be used for electrical connection of the signal tower. Mounting elements for base or tube mounting can be used to mount the signal tower. Features Siren element for 24 V AC/DC Volume can be adjusted using potentiometer Tone function can be adjusted using DIP switch Degree of protection: IP65, when mounted Make sure you always use the latest documentation. It can be downloaded from the product at phoenixcontact.net/products.

2 Table of contents 1 Description... 1 2 Table of contents... 2 3 Ordering data... 3 4 Technical data... 3 5 Set the volume and the tone type... 4 6 Example of a signal tower... 5 7 Assembly notes for a signal tower... 5 8 Assembling the individual elements... 5 9 Example for signal tower dimensions... 6 7944_en_02 PHOENIX CTACT 2

3 Ordering data Description Type Order No. Pcs./Pkt. Siren element, 8 tones, 24 V AC/DC, max. 100 db(a), tones can be selected via the DIP switch, black 4 Technical data PSD-S AE SM8-5 100DB/1 2700138 1 Dimensions (in mm) 72 Ø70 Diameter Height 70 mm 72 mm General data Material Polycarbonate PC Color black Weight 81 g Ambient temperature (operation) -30 C... 50 C Degree of protection IP65, when installed Mounting position any Electrical data Input voltage 24 V AC/DC Inrush current max. 500 ma Current consumption 80 ma Type of acoustic signal 8 tones, adjustable volume Signal frequency approx. 1 Hz (Pulse tone) Tone frequency approx. 1.6 khz Volume max. 100 db(a) (for continuous and pulse tone of 3.4 khz) Service life, electrical min. 5,000 h Operating time 100 % Approvals / conformities Conformance with EMC Directive 2004/108/EC For the latest approvals, please visit phoenixcontact.net/products. 7944_en_02 PHOENIX CTACT 3

5 Set the volume and the tone type Disconnect the power to the signal tower before changing the tone! Set tone type using the DIP switch Set the tone type using the DIP switch. Possible tones DIP switch Tone type Tone frequency Maximum volume 1 2 OFF Continuous tone Continuous tone 1.6 khz 100 db(a) 3.4 khz 93 db(a) OFF OFF Pulse tone (1 Hz) OFF Pulse tone (1 Hz) 1.6 khz 94 db(a) 3.4 khz 92 db(a) OFF OFF Trill tone (20 Hz) 1.6 khz 90 db(a) OFF Trill tone (20 Hz) 3.4 khz 91 db(a) OFF OFF OFF Hum tone (420 Hz) 1.6 khz 78 db(a) OFF OFF Hum tone (420 Hz) 3.4 khz 84 db(a) Figure 1 Potentiometer (1) and DIP switch (2) (view from below) Volume can be set using potentiometer Set the volume using the potentiometer. There is a maximum volume of 100 db(a) for 3,4 khz of continuous and pulse tone. 7944_en_02 PHOENIX CTACT 4

6 Example of a signal tower 1 7 Assembly notes for a signal tower Only use a maximum of five elements within a signal tower. Use only one audible element in a signal tower and position this element on top. When closing the bayonet locking system, observe the markings (see "Assembling the individual elements"). 8 Assembling the individual elements 2 Audible and optical signal elements are assembled in the same way. The illustration shows the assembly of two optical elements. 3 4 Figure 2 Example of a signal tower Key: 1 Audible signal element 2 Optical signal element 3 Connection element 4 Assembly element Figure 3 Assembling the individual elements Select the elements for your application. Connect the elements to be assembled so that the markings are aligned. Turn the upper element in the direction of the arrow. 7944_en_02 PHOENIX CTACT 5

9 Example for signal tower dimensions The following figure shows the dimensions of a typical signal tower. 86 112 56 4 x56(=224) 408 Ø70 Figure 4 Dimensions of a signal tower (example) 7944_en_02 PHOENIX CTACT GmbH & Co. KG 32823 Blomberg Germany 6 phoenixcontact.com