Nsg inductive switch transient test circuit

Similar documents
MD 200A High voltage differential probe

CALIBRATION KIT FOR EFT / BURST CAPACITIVE COUPLING CLAMP INA 3425 USER MANUAL A

INA 703 MAgNetIc field coil

MD 103 ESD TargET SET USEr ManUal B

CBA 400M MHZ to 400 MHZ

Advanced Test Equipment Rentals ATEC (2832) INA A

PA Automotive battery simulators

CDN 117 / 117-M CDN 118-T4 / 118-EXT-1 SIGNAL & DATA LINE COUPLING NETWORKS USER MANUAL M

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

RADIATED IMMUNITY TEST SYSTEM 6 GHz

COUPLING NETWORK (CN) FOR IEC / EN , DC TO 150 khz

GTEM cells. Emissions and immunity testing in a single, shielded environment

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

2015 RIGOL TECHNOLOGIES, INC.

MHz FUNCTION GENERATOR INSTRUCTION MANUAL

Radiated Immunity Test System 6 GHz

Model 4210-MMPC-W. Multi-measurement Prober Cable Kit. Overview

MONITORING DEVICE 4 khz to 400 MHz

2302 Battery Simulator 2306, 2306-PJ Battery/Charger Simulators

MODEL 3810/2 Line Impedance Stabilization Network

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE. ISO-STIM 01D STIMULUS ISOLATION UNIT ±100 V / ±10 ma, bipolar output

Model 4210-MMPC-L. Multi-measurement Prober Cable Kit. Overview. Quick start guide topics. Related documents

LBI-31807D. Mobile Communications MASTR II REPEATER CONTROL PANEL 19B234871P1. Maintenance Manual. Printed in U.S.A.

Voltage Transient Emission Test

Radiated immunity test system 6 GHz

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY

Test Systems. VSQ 3000/3002 Reference Radiation Source up to 3GHz

DIGIT & POINTER MULTIMETER

400 MHz Passive High-Voltage Probe R&S RT-ZH

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

1. General Instructions 2 2. Safety 2 3. Lamp Starting Test Instrument LSTI 5 3

NSG Hard keys for important functions. 5.7 color display, easy to use firmware. 3 power meter

Battery Simulator Battery/Charger Simulators

Two Line V-Network GLN-5040A USER MANUAL GW INSTEK PART NO. 99 Washington Street Melrose, MA Phone Toll Free

User s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation

USER'S MANUAL DMR-6700

Presco AG. Peak Voltmeter. Type PVM-100. Instruction Manual. Table of contents

QNP Accessory. For BLAXH300/ MHz Operating & Service Manual. Version

User s Manual. Miniature Passive Probe. IM EN 3rd Edition

DMM8900 SERIES USERS MANUAL

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany

Active Transmitter Combiner 8:1 AC 3200-II. Instruction manual

Operating Instructions / Voltage Tester per IEC with Phase and Polarity Tester and Phase Sequence Indicator

Model DIGITAL MULTIMETER

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY

COUPLING / DECOUPLING NETWORK (CDN) CDN AF TYPE, CDN CAN

ASX SERIES PACIFIC OPERATION MANUAL AC POWER SOURCE POWER SOURCE

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

PHV RO High Voltage Passive Probe. Instruction Manual

Tablet Oscilloscope Safety Information

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

8120 FUNCTION GENERATOR Operation Manual

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

SCXI CURRENT INPUT,HIGH-VOLTAGE TERMINAL BLOCK

Kentech Instruments Ltd. CPS3/S pulser Serial No. J03*****

Model 416A Gate and Delay Generator Operating and Service Manual

MODEL 421 Over/Under Motor Load Monitor

8110 FUNCTION GENERATOR. Safety Instruction. Safety Symbols

User s Manual Current Probe. IM E 2nd Edition IM E

Model MHz Arbitrary Waveform / Function Generator

Coupling / decoupling network (CDN) for screened or coaxial cables

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

SMART TWEEZERS Model ST-1 User s Manual Version 1.0

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

Documentation. PerfectPulse Fast Edge Signal Generator

Operating Manual. Model Channel. DC Signal Conditioner Amplifier

V1.3. TBLC08 50mH AC-LISN TBLC08

Installation and user s guide H A. NCi-5 non-contact tool setting interface

DM-46 Instruction Manual

ProfiScale MULTI Multimeter

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

312, 316, 318. Clamp Meter. Users Manual

INSTRUCTIONS MODELS AVX-TRR-SQMELF TEST JIG FOR USE WITH AVTECH AVR-EB4-B REVERSE RECOVERY TEST SYSTEMS SERIAL NUMBER:

INSTALLATION AND OPERATION MANUAL

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

Log Periodic Antenna

Part/Reorder Number: Version 1.0

TETRIS 1000 High Impedance Active Probe. Instruction Manual

HO118 Binning Interface User Manual * * Version 02. User Manual. Test & Measurement

CONTENTS MS2033A. 1.Introduction Safety Information...01

Model 113 Scintillation Preamplifier Operating and Service Manual

RIGOL. Quick Guide. DG1000 Series Dual-Channel Function/Arbitrary Waveform Generator. Jul RIGOL Technologies, Inc.

User s Guide. RP7000 Series Active Probe. Dec RIGOL Technologies, Inc.

Data Sheet. Agilent M9185A PXI Isolated D/A Converter. DISCOVER the Alternatives... Agilent MODULAR Products. 8/16-Channel 16-bit, ±16 V

AC 3. Active Antenna Combiner. Instruction manual

GE Interlogix Fiber Options S714D & S7714D. Instruction Manual FIBER-OPTIC NETWORK TRANSMISSION SYSTEM

W DC ELECTRONIC LOAD INSTRUCTION MANUAL

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

Model and

Portable Appliance Testers. OmegaPAT MI 2140 BetaPAT MI 2141 User Manual Ver Code No

RIGOL. Quick Guide. DG2000 Series Function/Arbitrary Waveform Generator. Sept RIGOL Technologies, Inc.

305 Stimulus Isolator. Description

DIGITAL MULTIMETER INSTRUCTION MANUAL

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

Antenna Splitter ASA 1. Instruction manual

Transcription:

1 Nsg 5071 - inductive switch transient test circuit User Manual 601-327A

Nsg 5071 - inductive switch transient test circuit User Manual NSG 5071 Inductive switch transient test circuit

Contents 1 Explanation of the symbols used in this manual 5 2 Warning symbols on the test system 5 3 General safety 8 3.1 Overcurrent protection 8 3.2 Voltage protection 8 3.3 General warnings 9 4 Introduction to the NSG 5071 10 5 Installation of the NSG 5071 12 6 Usage of the NSG 5071 for CI 220 15 6.1 Battery input 15 6.2 CI 220 DUT output 16 6.3 Selecting the pulse 17 6.4 Controlling the input signal 19 7 Usage of CI 260 waveform F 21 8 Relay monitoring, usage and replacement 22 8.1 Resetting the counter 22 8.2 Replacing the relays 23 8.3 Relay usage 24 9 Maintenance 26 9.1 Cleaning 26 9.2 Batteries 26 9.3 Calibration 26 10 Example plots 27 11 Dimensions and weight 31 12 Specifications 32 13 Environmental conditions 33 14 Declaration of conformity 34 15 Addresses 36

1 explanation of the symbols used in this manual 5 Please take note of the following explanations of the symbols used in order to achieve the optimum benefit from this manual and to ensure safety during operation of the equipment. The following symbol draws your attention to a circumstance where failing to observe the warning could lead inconvenience or impairment in performance. Example: Please mind the polarity when connecting DUT cables. The following symbol draws your attention to a circumstance where failing to observe the warning could lead to component damage or danger to the operating personnel. Caution sign: A situation that may cause damage to the equipment. Example: Connect the system only to rated mains power.

6 Danger sign: Possibly dangerous situation that may cause damage to persons or heavy damage to the test equipment or DUT. Example: It is dangerous to fail to observe safety warnings. NSG 5071 Inductive switch transient test circuit

2 warning symbols on the test system 7 This symbol is used on the test system to signify a dangerous condition if misused. Please read and understand the complete documentation of the NSG 5071 and the applicable standard references before putting the equipment into operation.

8 3 general safety The NSG 5071 system itself contains no dangerous voltages or currents, however, the application requires an external power source and can use up to 30 A for DUT power. Up to 30 A may be switched using the NSG 5071. Care should be taken in connecting and operating the DUT. 3.1 Overcurrent protection The NSG 5071 is designed using, and includes, the required Potter & Brumfield KUP-14A15-12 relay. The design can also (with the approval of Ford EMC) be used with other relays. It is important to limit the current in the application so as not to damage the relay that is installed, and in no case exceed 30 A, which is the maximum current limit of the NSG 5071. The user is responsible to limit the current of the battery voltage source to a level safe for the installed relay (10 A delivered). In case other relays are used, the current should be limited to a value of the installed relay, and not exceeding 30 A. 3.2 Voltage protection The NSG 5071 does not generate, on its own, dangerous voltages. However, it does contain inductances as part of the test setup that are switched to perform high voltage transient simulations. These transients may be high voltages caused by inductive kickbacks. Care should be used when powering the DUT through the NSG 5071 system. Refer to engineering or product documentation for your specific DUT. NSG 5071 Inductive switch transient test circuit

Potentially dangerous voltage may be present at the cables leading to and from the DUT. Take care and follow all applicable safety guidelines given for your specific DUT. 9 Operation of the NSG 5071 without the cover is dangerous and strictly forbidden. 3.3 General warnings DANGER! It is imperative that you read the following safety instructions and all safety instructions in the manuals of the connected peripheral systems before installing and starting this test system for the first time. DANGER! The electrical and mechanical safety equipment must not be removed, put out of operation or bypassed. Handle all safety equipment with care. If a safety device should be broken or is not working, the system must be put out of operation until the safety device is repaired or exchanged and fully in working order again. DANGER! HAZARDOUS AREA! Connectors on the test equipment should not be touched! The equipment may only be operated within an area that is explicitly declared a Test Floor (with appropriate signs) and protected against improper access. The operating instructions form an integral part of the equipment and must be available to the operating personnel at all times. All the safety instructions and advice notes are to be observed.

10 4 Introduction to the nsg 5071 The NSG 5071 is designed exactly in accordance with EMC-CS-2009.1 (hereafter referred to as the standard ) for test CI 220 pulses A1, A2-1, A2-2, C1, C2 and RI 130 using an inductive/relay transient generator test circuit (hereafter called test circuit ). Because the same type of relay is used, CI 260 waveform F is included in this test circuit. This test circuit is defined in annex F for the A, C Pulses and RI 130 and figure 19-10 for CI 260 waveform F. The basic philosophy of this test circuit is better reproducibility of actual switching transients. The reproducibility of this test circuit comes not from the output characteristics as in traditional conducted automotive immunity tests, but from a fixed design of the generator using several pre-defined components. Many of these components are defined in the standard as critical with no substitutions allowed. Overview of the NSG 5071 NSG 5071 Inductive switch transient test circuit

11 SW2 R2 220 Ω L2 100 mh R3 33 Ω R4 6 Ω SW3 C1 100 nf SW4 A BAT IN G RLY 1 BNC NC SW0 L1 5uH C D SW1 B C Pulse C Pulse A G G FG IN G E BNC Circuit Diagram NSG 5071

12 5 Installation of the nsg 5071 For RI 220 pulses, the NSG 5071 must be placed on, and connected to the test bench earth using the convenient connections. The ARB signals must be provided as shown in the following diagrams and expanded in the following sections. Mode 1 ARB Mode 2 & 3 To DUT BATT + - Installation for CI 220 pulses NSG 5071 Inductive switch transient test circuit

RI 130 contains a similar setup, but the output of the NSG 5071 is connected via two BNC cables to the parallel wire fixture. 13 ARB To Cl amp BATT + - Installation for RI 130 pulses For CI 220 and RI 130 pulses, the NSG 5071 must be connected to earth using the supplied earth connections. The earth connection of the NSG 5071

14 The installation for CI 260 waveform F is somewhat different. In waveform F, there are two signal sources that must be independantly controlled. These two signal sources both power the DUT and control the relay. For detials, see section 7. + - Signal Source 1 + - Signal Source 1 + - DUT Installation for CI 260 waveform F NSG 5071 Inductive switch transient test circuit

6 usage of the nsg 5071 for CI 220 15 6.1 Battery input The NSG 5071 is used per the guidelines in the standard. As seen in the circuit diagram, SW0 connects and disconnects the battery ( and О respectively) from the entire test circuit and DUT. As the circuit does nothing without battery, SW0 can be thought of as the power switch. The connectors labeled BAT IN are to be connected to the battery. While a power supply may be used, Ford specified a actual automotive battery during compliance testing and tests without an automotive battery are not considered compliant without specific permission from the standards writer. It is important to use only correct polarity! The negative BAT IN connector is, as defined in the standard, directly connected to chassis ground. The BAT IN connector and SW0 provides battery to the test circuit and DUT. The switching condition of RLY1 is dependant upon battery and the status of the FG IN voltage. The NPN transistor will pull activate the relay based on a positive TTL input signal. RLY1 is rated for 10 A.

16 Failure to observe proper polarity may result in damage to the DUT and NSG 5071! The supplied relay is exactly that specified in the standard. The standard recognizes the need for occasionally needing more battery current, and other relays may be used with written approval of Ford. In this case, the NSG 5071 has been specifically designed to accept up to 30 A of battery current. However, the supplied relay is specified for only 10 A. While the NSG 5071 can supply with up to 30 A, the supplied relay is specified 10 A max! For more information on exchanging the relays, please see the section 8. 6.2 CI 220 DUT output For all CI 220 testing, the DUT will be connected to either the pulse A or pulse C outputs. Pulse name Output connector to use A1 Pulse A A2-1 Pulse A A2-2 Pulse A C-1 Pulse C C-2 Pulse C NSG 5071 Inductive switch transient test circuit

17 The A1, A2-1 A2-2 DUT output The C1 and C-2 DUT output 6.3 Selecting the pulse Selecting the pulse is based on the switch positions of SW1 through SW4. Each pulse may be run in several modes, and some must be run in all three modes. Select the pulse using the handy reference printed on the front of the NSG 5071 and selecting the appropriate switch positions.

18 Pulse Mode SW1 SW2 SW3 SW4 A1 1, 2 Closed Closed Closed Closed A2-1 1 Closed Open Open Open A2-1, C-1 2 Closed Open Open Open A2-2, C-2 2 Closed Open Closed Open A2-1, C-1 3 Open Open Open Open A2-2, C-2 3 Open Open Closed Open The pulse selection table In all cases, the switch postioins is described below: During actual testing, it is a simple matter of choosing the correct switch positions and monitoring the DUT. For clarification, the purposes of the SW1 SW4 are outlined below. SW1 Switch 1 enables (open) or disabled (closed) the Mode 3 self chattering relay Mode. SW2 Switches 220 Ohms in parallel with L2, effectively shaping the pulse shape. SW3 Switches 100 nf capacitor in parallel with L2, effectively shaping the pulse shape. SW4 Increases the impedance between L1 and earth. NSG 5071 Inductive switch transient test circuit

6.4 Controlling the input signal Once the NSG 5071 is connected to a battery voltage source, the relay can be driven with a standard TTL signal. The timings of the control signals can be found in the standard, but are shown below for reference. 19 Mode 1 pulses are pulses that are triggered at fixed intervals. Mode 2 pulses are pulses that occur at defined, pseudorandom intervals. Mode 3 pulses use the same trigger signal as Mode 2 pulses, but the relay is self chattering during the trigger. Think of Mode 3 pulses as gated self-chattering events. The user must supply the TTL signals or use an NSG 5600 and the supplied cable.

20 The Mode 1 control signal The Mode 2 and 3 control signal NSG 5071 Inductive switch transient test circuit

7 Usage of CI 260 waveform F 21 Waveform F is a complex dropout test that depends on two controlled signal sources called Signal Source 1 and Signal Source 2 in the standard. As you can see in the following schematic, Signal Source 2 controls primarily the relay switching. When 12 V is supplied by Signal Source 2, the relay RLY2 will chatter. When Signal Source 2 is at 0 V, the DUT will be powered through Signal Source 1, which is also independently controlled. RLY 2 + Signal Source 1 - + Signal Source 2 - NC + - DUT T1 T1 T1 T1 T3 T4 The control of CI 260 waveform F

22 8 Relay monitoring, usage and recplacement The NSG 5071 is supplied with two Potter & Brumfield KUP-14A15-12 relays. Due to the extreme nature of the test, the relays performance may be degraded over time. Therefore, the relays are recommended by the standard to be replaced after 100 hours of operation. A counter is provided to determine how long the relays are used. Any time the relay is active, the counter will count. The NSG 5071 does not need to be actively switching at the time, but if the relay gets power, from BAT IN (CI 220) or Signal ssurce 1 is set to battery voltage (CI 260) the timer will run. This is, of course, the most conservative interpretation of usage, but represents a compromise to give the users of tracking the relay usage while at the same time having no effect on the pulses applied to the DUT. 8.1 Resetting the counter Each counter operates independently for RLY1 and RLY2 for CI 220/RI 130 and CI 260 respectively. Resetting the counter may be performed by pressing the red button on the counter. Resetting the counter NSG 5071 Inductive switch transient test circuit

8.2 Replacing the relays The relays may be replaced by loosening the five thumbscrews on the top of the NSG 5071 and carefully sliding the top cover to the rear. Take care not to damage the copper guide pins or the RF gasket. Everything should be disconnected to the NSG 5071 when exchanging relays. 23 Loosening the thumbscrews Removing the cover Next, the relays can be removed by firmly grasping and lifting the relay and with a slight rocking motion.

24 Firmly grasping and lifting the relay Replacing the relay is a simple matter of pressing the relay into the supplied socket and closing the cover. Take care not to damage the copper guide pins and RF gasket. The copper guides and RF gasket 8.3 Relay usage The NSG 5071 contains two of the Potter & Brumfield KUP-14A15-12 that are specified in the standard. However, with the authorization of the standards writer, other relays may be used. For this reason, the NSG 5071 is designed for more current than the built-in relay can handle, and it provides connections for other relays. The convenient screen on the circuit board defines the various connections. Take care with the connections and the overall current limit of the system when using relays other than the KUP-14A15-12. NSG 5071 Inductive switch transient test circuit

The user is responsible to limit the current of the battery voltage source to a level safe for the installed relay (10 A delivered). In case other relays are used, the current should be limited to a value of the installed relay, and not exceeding 30 A. 25 The connections provided for other relays It is important to remove the KUP-14A15-12 before using any other type of relay.

26 9 Maintenance The only user replaceable parts are the relays RLY1 and RLY2. No other user serviceable parts are inside. The KUP-14A15-12 should be regularly checked. In some cases, it may wear out in much less than 100 hours. This is relay considered a consumable item in the NSG 5071. 9.1 Cleaning Clean only with a clean, dry cloth. No cleaners are recommended. 9.2 Batteries The clock has an internal, non-replaceable battery. This battery is rated for 10 years. Contact your Teseq representative for replacements. 9.3 Calibration No calibration is required. You should periodically check your NSG 5071 to ensure that the output can be compared to the example plots in the standard, and in this document. NSG 5071 Inductive switch transient test circuit

10 Example plots 27 Your NSG 5071 should have plots that are representative of the plots seen here, and in the standard. Please note that these pulses are pseudo-random and every pulse will usually not appear exactly as shown. Additionally, it if often necessary to trigger on current see the standard for more details. Pulse A1

28 Pulse A2-1 Detail Pulse A2-2 Contact break NSG 5071 Inductive switch transient test circuit

29 Pulse A2-2 Contact make and break Pulse C1

30 Pulse C2 CI 260 Waveform F NSG 5071 Inductive switch transient test circuit

11 Dimensions and weight 31 Dimensions (LxWxH) Weight 353 x 270 x 126 mm (13.9 x 10.6 x 5 inch) 8.65 kg (19 lbs)

32 12 Specifications Maximum input voltage (Umax) Signal Source 1, Signal Source 2 BAT IN Maximum DUT current (Imax) Signal Source 1, Signal Source 2, BAT IN TTL control signal 15 V 10 A (Installed KUP-14A15-12 relay 30 A (Other relay) TTL low: 0-0.4 V TTL high: 2.63-5 V NSG 5071 Inductive switch transient test circuit

13 Environmental conditions 33 Temperature range Operation at: Storage at: Humidity: Air pressure: +10 to +40º C -10 to +60º C 30 to 78% (non condensing) 860 to 1060 hpa

34 14 Declaration of conformity NSG 5071 Inductive switch transient test circuit

NOTES 35

36 Headquarters Teseq AG 4542 Luterbach, Switzerland T + 41 32 681 40 40 F + 41 32 681 40 48 sales @ teseq.com www.teseq.com Manufacturer Teseq AG 4542 Luterbach, Switzerland T + 41 32 681 40 40 F + 41 32 681 40 48 sales @ teseq.com China Teseq Company Limited T + 86 10 8460 8080 F + 86 10 8460 8078 chinasales @ teseq.com Germany Teseq GmbH T + 49 30 5659 8835 F + 49 30 5659 8834 desales @ teseq.com Singapore Teseq Pte Ltd. T + 65 6846 2488 F + 65 6841 4282 singaporesales @ teseq.com Taiwan Teseq Ltd. T + 886 2 2917 8080 F + 886 2 2917 2626 taiwansales @ teseq.com France Teseq Sarl T + 33 1 39 47 42 21 F + 33 1 39 47 40 92 francesales @ teseq.com Japan Teseq K.K. T + 81 3 5725 9460 F + 81 3 5725 9461 japansales @t eseq.com Switzerland Teseq AG T + 41 32 681 40 50 F + 41 32 681 40 48 sales @ teseq.com UK Teseq Ltd. T + 44 845 074 0660 F + 44 845 074 0656 uksales @ teseq.com USA Teseq Inc. T + 1 732 417 0501 F + 1 732 417 0511 Toll free +1 888 417 0501 usasales @ teseq.com To find your local partner within Teseq s global network, please go to www.teseq.com December 2010 Teseq Specifications subject to change without notice. Teseq is an ISOregistered company. Its products are designed and manufactured under the strict quality and environmental requirements of the ISO 9001. This document has been carefully checked. However, Teseq does not assume any liability for errors or inaccuracies.