GAFCHROMIC. Therapy Dosimetry Media Models to

Similar documents
- Water resistant. - Large size.

Nuclear Associates

GAFCHROMIC HD-810 Radiochromic Dosimetry Film Configuration, Specifications and Performance Data

A study of GafChromic XR Type R film response with reflective-type densitometers and economical flatbed scanners

IV. 4. An Optical Common-mode Rejection for Improving the Sensitivity Limit of a Radiochromic Imaging Film

State of the Art Film Dosimetry

A Guide to Radiochromic Film Dosimetry with EBT2 and EBT3

Post-irradiation colouration of Gafchromic EBT radiochromic film

Cylindrical Ion Chambers Victoreen Model 550 Series

The most Comprehensive, Reliable, Economical and Easy to use GAFCHROMIC film based RT QA system Updated Feb 08 BUSINESS UNIT OF ISP

SCINTILLATING FIBER DOSIMETER ARRAY

ISPFILMQATM STATE-OF-THE-ART RADIOTHERAPY VERIFICATION SOFTWARE. Supports all major radiotherapy technologies! FilmQA TM

Cylindrical Ion Chambers

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Nuclear Associates

NDT Supply.com 7952 Nieman Road Lenexa, KS USA

Mammographic Accreditation Phantom Nuclear Associates Model

Inovision Model 451P Pressurized µr Ion Chamber Survey Meter

Using Radiochromic Film Tips and Techniques

Development of new dosimeter for measuring dose distribution in CT

Analysis of Post-exposure Density Growth in Radiochromic Film with Respect to the Radiation Dose

GafChromic QuiCk Phantom with EBT3P/3+P Film and FilmQA Pro for Radiation Therapy Dosimetry Applications

GafChromic EBT2 and EBT3 Films for Ball Cube II Phantom

Dosimetric properties of improved GafChromic films for seven different digitizers

Model R2002. Instruction Manual. Infrared Thermometer. reedinstruments www.

X-ray Imaging. PHYS Lecture. Carlos Vinhais. Departamento de Física Instituto Superior de Engenharia do Porto

Temperature Compensated Barometers Model Oakton. NIST Traceable Digital Thermometer Model Radiation Oncology

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

COMPUTED RADIOGRAPHY CHAPTER 4 EFFECTIVE USE OF CR

Nuclear Associates

Acceptance Testing of a Digital Breast Tomosynthesis Unit

When small things matter. Small Field Dosimetry Application Guide

Homogeneity of GAFCHROMIC EBT2 film among different lot numbers

ELECTRONIC CONTROL CONCEPTS 160 Partition Street Saugerties, NY or local phone

FFDM in the Field: Physicist's Role in the QC of Mammography Laser Printers May Carl R. Keener, Ph.D., DABMP, DABR

GCMS-3 GONIOSPECTROPHOTOMETER SYSTEM

spectro-guide Total Appearance Control color and gloss in one unit Easy to use and handle Solid Color

Quality control of Gamma Camera. By Dr/ Ibrahim Elsayed Saad 242 NMT

Test Equipment for Radiology and CT Quality Control Contents

PD233: Design of Biomedical Devices and Systems

UP-D74XRD. DICOM Digital Imager.

Nuclear Associates

Fast Laser Raman Microscope RAMAN

Quality Control for Stereotactic Breast Biopsy. Robert J. Pizzutiello, Jr., F.A.C.M.P. Upstate Medical Physics, Inc

Electronic Brachytherapy Sources. Thomas W. Rusch

Unit thickness. Unit area. σ = NΔX = ΔI / I 0

Nuclear Associates Precision Photometer

Experiences of users in Digital Radiography

Nuclear Associates

PSD Characteristics. Position Sensing Detectors

EPSON Perfection Scanner Parts. Scanner Specifications. Basic Specifications

A new approach to film dosimetry for high energy photon beams: Lateral scatter filtering

Computed Radiography

LED Tester BTS256-LED

Dose Reduction and Image Preservation After the Introduction of a 0.1 mm Cu Filter into the LODOX Statscan unit above 110 kvp

Beam-Restricting Devices

Nuclear Associates

II Victoreen Model 7020/7040 THEBES. Radiation Oncology. Introduction. Features. Applications

NOT FOR DISTRIBUTION JINST_083P_0914 v1

Improved spatial resolution by MOSFET dosimetry of an x-ray microbeam

ABB MEASUREMENT & ANALYTICS. TALYS ASP500 series Flexible analyzer for real-time control of chemical processes

Fast Laser Raman Microscope RAMAN

Characterisation of gafchromic EBT2 film for use in radiation therapy dosimetry

Radioisotope Shielded Work Station Components Models to

STEREOTACTIC BREAST BIOPSY EQUIPMENT SURVEYS

Bandpass Edge Dichroic Notch & More

transmission and reflection characteristics across the spectrum. 4. Neutral density

BRANDON RICE UNIVERSITY OF FLORIDA

Comparison of peripheral dose measurements using Ionization chamber and MOSFET detector

Nuclear Associates

SRS MapCHECK. SRS Patient QA, No Film. Your Most Valuable QA and Dosimetry Tools

Nuclear Associates , , CT Head and Body Dose Phantom

3D Diode Array Commissioning: Building Confidence in 3D QA Technology

Model S471-LED Optometer

NEMA. Cardiology Phantom Nuclear Associates Model Diagnostic Imaging. Introduction. Features. Applications

Intraoral X-Ray For Film and Digital Systems

CFT-90 Converted Green High Brightness Green LED

Measurements of MeV Photon Flashes in Petawatt Laser Experiments

Detector-Filter Combination Series

CRISATEL High Resolution Multispectral System

Spatially Resolved Backscatter Ceilometer

Evaluation of a commercial flatbed document scanner and radiographic film scanner for radiochromic EBT film dosimetry

STUDENT REVIEW QUESTION SET K CR/DR CONTENT AREA

Grid patterns, spatial inter-scan variations and scanning reading repeatability in radiochromic film dosimetry

EPSON P R O D U C T I N F O R M A T I O N G U I D E UPDATE EPSON GT /7/01 TABLE OF CONTENTS

A True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY. Series 4 CR

Cartogam Real-Time Portable Gamma-Ray Imaging System

New spectral benefi ts, proven low dose

English User's Guide

ADVANCED THERAPY DOSIMETER MODEL 35040

Introduction of a Single Chip TLD System for Patient Dosimetry

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

QA Considerations. QA for LGK Perfexion : : Follow NRC licensing guidelines (10( CFR ) Leksell Gamma Knife Perfexion

EPSON GT Scanner Parts. Scanner Specifications. Maximum document size

Nuclear Associates

QUANTUM CALCU-FLASH-S OPERATING INSTRUCTIONS

Monte Carlo study on a new concept of a scanning photon beam system for IMRT

Detectors for small field dosimetry

Mammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over

Thermo Scientific SPECTRONIC 200

Transcription:

GAFCHROMIC Therapy Dosimetry Media Models 37-040 to 37-045! Superior uniformity and sensitivity! Dose rate and fractionation independent! Maps dose distribution! Provides quantitative measurements (via densitometer or scanner)! No darkroom (handle in room light, no chemicals, no waste)! Water-resistant Introduction GAFCHROMIC Therapy Dosimetry Media is a radiation-sensitive imaging film that is colorless, grainless, and offers a very high spatial resolution, making it invaluable for measuring dose distribution around small brachytherapy sources and stereotactic radiosurgery fields. It is available in a variety of dose sensitivity and size formats. Applications Can be used in plastic phantoms or (with special care) in water phantoms Can be used invivo for certain high-dose or multifraction applications Routine dosimetry, such as dose mapping, beam profiling and highresolution radiography Surface dose and buildup region Dose distributions Penumbra characterizations Depth dose measurements Multi-leaf collimator shaped beams Stereotactic radiosurgery beam parameters Dynamic wedge profiles IMRT (Intensity Modulated Radiotherapy Treatment) dose distributions Dose distributions near traditional and new endovascular brachytherapy sources GAFCHROMIC superior to conventional film in dosimetry studies 1 GAFCHROMIC s sensitivity to energy change is far less than silver-based films (see graph) 2 References 1. P.J. Muench, A.S. Meigooni, R. Nath, and W.L. McLaughlin, Photon Energy Dependence of the Sensitivity of Radiochromic Film and Comparison with Silver Halide Film and LiF TLDs Used for Brachytherapy Dosimetry, Medical Physics, 18:4 (July/August 1991), 769-775. 2. W.L. McLaughlin, C. Yun-Dong, C.G. Soares, A. Miller, G. Van Dyk, and D.F. Lewis, Sensitometry of the Response of a new Radiochromic Film Dosimeter to Gamma Radiation and Electron Beams, Nuclear Instruments and Methods in Physics Research, A302 (1991), 165-176.

Therapy range dosimetry media types GAFCHROMIC MD-55 (Model 37-041) Very high resolution; tissue equivalent; dynamic range (1.0 to 100 Gy); energy fractionation effects; available in 5 x 5 inch sheets GAFCHROMIC MD-22 (Model 37-041-2525) Very high resolution; tissue equivalent; dynamic range (1.0 to 100 Gy); energy fractionation effects; available in 2.5 x 2.5 inch octagonal shaped sheets (ideal for IMRT Phantom Film Stack Insert Model 74-013 applications) GAFCHROMIC HD-810 (Model 37-040) Very high resolution; tissue equivalent; dynamic range (5 to 400 Gy); energy fractionation effects; available in 8 x 10 inch sheets GAFCHROMIC D-200 (Model 37-043) Very high resolution; tissue equivalent; dynamic range (5 to 400 Gy); energy fractionation effects; available in film strips that have an overall size of 12 x 60 mm with an active area (window) of 8 x 22 mm (well suited for spectroscopy applications) GAFCHROMIC HS (high sensitivity ) (Model 37-044) Very high resolution; tissue equivalent; dynamic range (0.5 to 40 Gy); energy fractionation effects; available in 5 x 5 inch sheets GAFCHROMIC HS-14 (high sensitivity ) (Model 37-044- 1400) Very high resolution; tissue equivalent; dynamic range (0.5 to 40 Gy); energy independent (> 0.2 MeV); dose rate independent; no dose fractionation effects; available in film strips measuring 0.5 x 3.875 inch GAFCHROMIC XR - Type T (Model 37-045) It s a transparent radiochromic dosimetry film optimized for measuring and mapping low-energy photons; ideal for low dose rate brachytherapy; dynamic range (0.1 to 10 Gy); no significant energy dependence (60 to 120 kev); dose rate and fractionation independent; very high resolution; available in 5 x 5 inch sheets Temperature Store below 77 F (25 C). Do not use above 131 F (55 C) Humidity Below 77 F (25 C), no humidity effect, 50% relative humidity or less is preferred 37-041* GAFCHROMIC MD-55 Therapy Dosimetry Media, package of five 5 x 5 inch sheets 37-041-2525* GAFCHROMIC MD-22 Therapy Dosimetry Media, package of twenty 2.5 x 2.5 inch octagonal shaped sheets 37-040* GAFCHROMIC HD-810 Therapy Dosimetry Media, package of five 8 x 10 inch sheets 37-043* GAFCHROMIC D-200 Therapy Dosimetry Media, package of two-hundred film strips. Each strip has an overall size of 12 x 60 mm with an active area (window) of 8 x 22 mm 37-044* GAFCHROMIC HS Therapy Dosimetry Media, package of five 5 x 5 inch sheets 37-044-1400* GAFCHROMIC HS-14 Therapy Dosimetry Media, package of twenty-five 0.5 x 3.875 inch film strips Model 37-045* GAFCHROMIC XR - Type T Low Dose Rate Brachytherapy Dosimetry Media, package of five 5 x 5 inch sheets See Radiochromic Densitometer data sheet (Model 37-443) for complete specifications 2x the sensitivity of MD-55. * Use Radiochromic Densitometer (Model 37-443). are subject to change without notice. GAFCHROMIC is a registered trademark of International Specialty Products. 37-040-ds rev 3 11 mar 03

Optimized for use with GAFCHROMIC Dosimetry Media! Designed to measure the optical density of self-developing GAFCHROMIC Dosimetry Media! Optimized to measure the principle (671 nm) absorption spectrum peak of GAFCHROMIC Dosimetry Media! High-precision, instant readout, easy to use! Compact, hand-held, rugged! Unsurpassed performance and value; priced at a fraction of the cost of laser densitometers! Features a high-quality 2-D film transport! Provides three-times the sensitivity of He-Ne laser densitometers Radiochromic Densitometer with Film Transport System Nuclear Associates Model 37-443 Introduction The Radiochromic Densitometer is a highly accurate, reliable, and rugged test tool that allows precise and repeatable measurements to be made quickly and easily. Its state-of-the-art design incorporates a narrow bandpass filter. This filter matches the principle peak of the dose absorption spectrum for our GAFCHROMIC Dosimetry Media, thus maximizing sensitivity and calibration stability. By using the Radiochromic Densitometer (Model 37-443) with Film Transport System, readings of optical density for GAFCHROMIC Dosimetry Media can be obtained directly, accurately, and reproducibly. The two-dimensional film transport system is supplied with the radiochromic densitometer. Its micrometer-like design provides a precise method of holding and moving a piece of GAFCHROMIC Dosimetry Media over the aperture of the densitometer in both x and y dimensions. The micrometer movement and the device s vernier scale provide an x-y axis precision of ± 0.1 mm. The Radiochromic Densitometer includes a handy carrying/storage case and a five-step calibrated density tables (gray scale). A durable, aluminum-bottom casing houses 4 AA batteries (good for approximately 3,000 exposures), and the detector light source. Densitometer Density range 0 to 4.00 Accuracy ± 0.02 D over specified range Reproducibility ± 0.01 D Aperture 2 mm Measuring length (throat) 5.3 in (135 mm) Zero range Auto-zeros to density 0.0 (for densities up to 1.00) Sensor High-efficiency silicon photodiode Light source Ultra-bright red LED. A bandpass filter mounted above the LED provides a 10 nm bandwidth centered at 671 nm. Lamp turns on during measurement; provides extremely long life with minimum spectral and intensity degradation; reduces specimen heating to a minimum Controls Zero button Automatically zeros unit Power On/Off switch Read-button Initiates read sequence Calibration control Screwdriveradjustable; 20-turn potentiometer used to calibrate against a known step tablet Lamp-button Turns light source on for three seconds Operating temperature 50º to 104ºF (10º to 40ºC) Display 3 digit, 0.5 inch LCD with polarity and low-battery indicator Power Four 1.5 V AA batteries Dimensions 3.2 (w) x 7.1 (d) x 2.4 in (h) (81 x 180 x 61 mm) Weight 1.8 lb (0.8 kg) Film transport system Range of film movement 6 x 3 cm Precision ± 0.1 mm Dimensions 5.87 (w) x 10.87 (l) x 0.5 in thick (14.9 x 27.8 x 1.6 mm). Base thickness plus measuring device height equals 2.12 inch Weight 2.2 lb (1 kg) 37-443 Radiochromic Densitometer with Film Transport System For additional information, please contact Cardinal Health, Radiation Management Services customer service at 440.248.9300, 800.850.4608, or fax: 440.349.2307; located at 6045 Cochran Road, Cleveland, Ohio 44139-3303, USA. Tested. Meets applicable standards. are subject to change without notice. GAFCHROMIC is a registered trademark of International Specialty Products. Copyright 2003 Cardinal Health, Inc. or one of its subsidiaries. All rights reserved. 37-443-ds rev 1 11 mar 03

Howtek MultiRAD 860 Model 37-860 Radiation Oncology Advanced generation film digitizer technology offers diagnostic quality primary read capabilities, digital overread of mammograms, digital comparative read of prior mammograms, and detection of microcalcifications and lesions. Final Read initial quality (e.g., in orthopedics) saves steps, time, duplication, and non-chargeable preliminary reads. More information and less noise from dense film areas -- see in the dark even where films are dense or overexposed. High energy red LED illumination offers laser quality at fluorescent prices.! 3.85 OD HiResolve Film Digitizer! Technical advances account for image superiority! Dynamic range of 3.85 OD - Reduces image noise by almost half! Patent pending solid state, high energy red LED illuminator - Precise control of individual LED s - Self-calibrating for optimal illumination and brightness! Consistent photometric accuracy - Film to film, hour to hour, day to day! No fluorescent artifacts - No hot spots, no shifting illumination or flicker! No annual laser maintenance costs Diagnostic quality Dynamic range 0 to 3.85 OD Gray scale 8 or 12 bit Spot size 43.5 micron at 8 K High resolution K Dots per inch Resolving power 14x17x12 bit 8x10x12 bit 1 K 73 dpi 1.4375 lp/mm 2.5 MB 0.8 MB 2 K 146 dpi 2.875 lp/mm 10 MB 3.4 MB 4 K 292 dpi 5.75 lp/mm 40 MB 13 MB 8 K 584 dpi 11.5 lp/mm 162 MB 54 MB Productivity Scan rate 125 lines/second, 14 x 17 inch film scanned @ 2 x 2.5 K, 12 bit in < 20 seconds Film sizes 5 to 14 inch (w) (12.7 to 35.6 cm); up to 40 inch (l) (101.6 cm) Batch feeder Standard 60 sheet film feeder Selective mode Region of interest high resolution capture Technology Light source Patent pending solid state, high energy red LED illuminator Detection system 8,000 element CCD, low noise high fidelity system Calibration Automatically and continuously consistent photometric accuracy film to film, hour to hour, day to day, week to week Feeding mechanism Patented SureFeed system Interface SCSI-2 Applications software Multiple vendors Dimensions 18 (w) x 14 (d) x 18.5 in (h) (45.72 x 35.56 x 47 cm) Power requirements 100 to 240 V; 50/60 Hz; 1.5 A Temperature Operating 60 to 90 F (16º to 32ºC) Non-operating - 30 to 160 F (- 34ºC to 71ºC) Relative humidity 35 to 85%, non-condensing Certification TuV; UL; CE; FCC-A; FDA 510(k) 970908 Weight 60 lb (27.3 kg) 37-860 Howtek MultiRAD 860 are subject to change without notice. MultiRAD, HiResolve, and SureFeed are trademarks of Howtek. 37-860-ds rev 1 11 mar 03

Howtek MultiRAD 460 Model 37-460! 3.85 OD Diagnostic Film Digitizer! Technical advances account for image superiority! Dynamic range of 3.85 OD - Reduces image noise by almost half! Patent pending solid state, high energy red LED illuminator - Precise control of individual LED s - Self-calibrating for optimal illumination and brightness! Consistent photometric accuracy - Film to film, hour to hour, day to day! No fluorescent artifacts - No hot spots, no shifting illumination or flicker! No annual laser maintenance costs Advanced generation film digitizer technology offers diagnostic quality primary read capabilities, and accurate comparative readings where clinical decisions are based on small changes in gray scale. Critical clinical information from small changes in density enables the diagnostician to discern fine tissue damage. Final Read initial quality saves steps, time duplication, and non-chargeable preliminary reads. More information and less noise from dense film areas -- see in the dark even where films are dense or overexposed. High energy red LED illumination offers laser quality at fluorescent prices. Diagnostic quality Dynamic range 0 to 3.85 OD Gray scale 8 or 12 bit Spot size 43.5 micron at 8 K High resolution K Dots per inch Resolving power 14x17x12 bit 8x10x12 bit file size 1 K 73 dpi 1.4375 lp/mm 2.5 MB 0.8 MB 2 K 146 dpi 2.875 lp/mm 10 MB 3.4 MB 4 K 292 dpi 5.75 lp/mm 40 MB 13 MB Productivity Scan rate 125 lines/second, 14 x 17 inch film scanned @ 2 x 2.5 K, 12 bit in < 20 seconds Film sizes 5 to 14 inch (w) (12.7 to 35.6 cm); up to 40 inch (l) (101.6 cm) Batch feeder Standard 60 sheet film feeder Selective mode Region of interest high resolution capture Technology Light source Patent pending solid state, high energy red LED illuminator Detection system 8,000 element CCD, low noise high fidelity system Calibration Automatically and continuously consistent photometric accuracy film to film, hour to hour, day to day, week to week Feeding mechanism Patented SureFeed system Interface SCSI-2 Applications software Multiple vendors Dimensions 18 (w) x 14 (d) x 18.5 in (h) (45.72 x 35.56 x 47 cm) Power requirements 100 to 240 V; 50/60 Hz; 1.5 A Temperature Operating 60 to 90 F (16º to 32ºC) Non-operating - 30 to 160 F (- 34ºC to 71ºC) Relative humidity 35 to 85%, non-condensing Certification TuV; UL; CE; FCC-A; FDA 510(k) 970908 Weight 60 lb (27.3 kg) 37-460 Howtek MultiRAD 460 are subject to change without notice. MultiRAD and SureFeed are trademarks of Howtek. 37-460-ds rev 1 11 mar 03