ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

Similar documents
DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

770E DIGITAL MULTIMETER OPERATOR S MANUAL

AMM-1022 Digital Multimeter USER`S MANUAL

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

DVM1190 DIGITAL MULTIMETER

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

USER'S MANUAL DMR-6700

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

OPERATOR S INSTRUCTION MANUAL

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

User Manual. All rights reserved. Specifications are subject to change without notice.

Digital Clamp Meter Model: &

True RMS Digital Multimeter Model:

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

DIGITAL MULTIMETER INSTRUCTION MANUAL

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

KMD-S04 Multímetro de bolsillo

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

AC/DC CLAMP METER USER S MANUAL

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

DM-45 Digital Multimeter

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

Pen-type DIGITAL MULTITESTER

User Manual. All rights reserved. Specifications are subject to change without notice.

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

UT207A/208A/209A Operating Manual. Table of Contents

400Amp True RMS AC/DC Clamp Meter Model EX613

Autoranging Multimeter Extech EX503

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

MULTIMETRE DIGITAL 3 3/4 AVEC ECHELLE AUTOMATIQUE & EXTINCTION AUTOMATIQUE MANUEL D UTILISATION

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Model UT10A: OPERATING MANUAL Table of Contents (1)

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

Model DIGITAL MULTIMETER

DIGITAL MULTIMETER AUTORANGING

MS8216 DIGITAL MULTIMETER OPERATOR S MANUAL

ET-3888 True RMS Clamp Meter. User Manual

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

USER'S MANUAL AM-100 AM-105 TRMS AM-110 TRMS. Digital Multimeters

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL- KM 2782 / 2782-T

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

INSTRUCTION MANUAL DIGITAL MULTIMETER

User s Guide. 400A AC/DC Clamp Meter. Model MA220

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

NOTE: Fully read and understand this manual before using this Digital Multimeter.

400Amp True RMS AC Clamp Meter + NCV

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

R/C SMD Tweezers Multimeter Model RC200

DIGITAL MULTIMETER OPERATOR S MANUAL

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

User Manual Digital Multimeter

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

200Amp AC Clamp Meter + NCV Model MA250

DIGIT & POINTER MULTIMETER

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

MS2030 CAT III 600 V A V AUTO RS232

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

OPERATING INSTRUCTION

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

Sales: Technical: Fax:

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

The Meter Structure The Figure 2-1 shows the Meter structure.

Analog Technologies VC99. Multimeter FEATURES

User Manual Digital Multimeter. model no.: MSR-U1000

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

ProfiScale MULTI Multimeter

Dawson DDM190. Digital Multimeter User s Manual

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

CONTENTS MS2033A. 1.Introduction Safety Information...01

Digital Multimeter, Pen Type

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

DMM8900 SERIES USERS MANUAL

Model : OPERATING MANUAL Table of Contents (1)

ATK Clamp Meter

Table of Contents Title Page

RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL

Model UT20B: OPERATING MANUAL Table of Contents (1)

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

DIGITAL CLAMP METER Use s Manual

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

Instruction Manual IDM 66RT Digital Multimeter

1.General instructions Specifications Description...7

S-11 S-11. Digital Multimeter Operating Instruction. Digital Multimeter Operating Instruction

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Digital Multimeter with Backlight

Transcription:

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL 1

1. SAFETY INFORMATION SAFETY SYMBOLS Warning! Dangerous Voltage (Risk of electric shock). Caution! Refer to the user s manual before using this Meter. Double Insulation (Protection Class Ⅱ). Alternating Current (AC). Direct Current (DC). Either DC or AC. Ground (maximum permitted voltage between terminal and ground). The symbol indicating separate collection for electrical and electronic equipment. The RESPONSIBLE BODY shall be made aware that, if the instrument is used in a manner not specified by the manufacturer, the protection provided by the instrument may be impaired. The finger or any part of your body shall not be beyond the barrier of the test probe when measuring. Individual protective equipment must be used if HAZARDOUS LIVE parts in the installation where measurement is to be carried out could be ACCESSIBLE. The following safety information must be observed to insure maximum personal safety during the operation at this meter. 1.1 Do not operate the meter if the body of meter or the test leads appear damaged. 1.2 Check the main function dial and make sure it is at the correct position before each measurement. 1.3 When making current measurements ensure that the circuit not live before opening it in order to connect the test leads. 1.4 Do not perform resistance, capacitance, diode and continuity test on a live power system. 1.5 Do not apply voltage between the test terminals and test terminal to ground that exceeds the maximum limit record in this manual. 1.6 Exercise extreme caution when measuring live system with voltage greater than 60V DC or 30V AC. 1.7 Change the battery when the symbol appears to avoid incorrect data. 1.8 Use the DMM indoor, altitude up to 2000m and temperature 5 to 40. Maximum relative humidity 80% for temperatures up to 31, decreasing linearly to 50% relative humidity at 40. Pollution Degree 2. 2

2. SPECIFICATIONS 2.1 GENERAL SPECIFICATIONS Display: LCD with a max. reading of 6000. Range control: Auto range & Manual range control Polarity: Automatic negative polarity indication. Zero adjustment: Automatic. Over range indication: The OL or -OL display. Low battery indication: Display " " sign. Data hold: Display DH sign. Relative measurement: Display sign. Auto Power Off: When measurement exceeds 15 minutes without switching mode and pressing key, the meter will switch to standby mode. Press any key to exit standby mode. When restart the system, press and hold SELECT key to disable auto power off. Safety standards: EMC/LVD. CAT Ⅲ 600V. CAT Ⅳ 300V. The meter is up to the standards of IEC1010 Double Insulation,Pollution Degree 2, Overvoltage Category Ⅲ. Operating environment: Temperature 32 to104 F (0 C to 40 C), Humidity 80% RH. Storage environment: Temperature -4 to140 F (-20 C to 60 C), Humidity 90% RH. Fuse: F0.8A 600V 5 x 20mm, F15A 600V 5 x 20mm. Power supply: 9V battery (6F22). Test lead probe: RE10, CATⅢ 600V / CATⅣ 300V, 15A, L=90cm. Dimension: 177(H) x 92(W) x 40(D) mm Weight: Approx. 320g (including battery). 2.2 ELECTRICAL SPECIFICATIONS Accuracies are ± (% of reading + number in last digit) at 23 ± 5 C, 75% RH. 2.2.1 DC Voltage 60.00mV ± ( 0.8%+2 ) 0.01mV 600.0mV 0.1mV 6.000V 1mV ± ( 0.5%+2 ) 60.00V 10mV 600.0V 100mV 600V ± ( 0.8%+2 ) 1V Impedance: 10MΩ,More than 100MΩ on 60mV/600mV range 3

2.2.2 AC Voltage 60.00mV 0.01mV ± ( 1.2%+3 ) 600.0mV 0.1mV 6.000V 1mV 60.00V ± ( 0.8%+3 ) 10mV 600.0V 100mV 600V ± ( 1.2%+3 ) 1V AC True RMS Frequency: 40Hz~1kHz Impedance: 10MΩ,More than 100MΩ on 60mV/600mV range 2.2.3 DC Current 600µA 0.1µA 6000µA 1µA ± ( 1.2%+2 ) 60mA 10µA 600mA 100µA 6A 1mA ± ( 2.0%+3 ) 15A 10mA Overload protection: 0.8A/600V, 15A/600V fuse Continuous testing the maximum steady-state current of 1A 2.2.4 AC Current 600µA 0.1µA 6000µA 1µA ± ( 1.5%+3 ) 60mA 10µA 600mA 100µA 6A 1mA ± ( 2.5%+5 ) 15A 10mA AC True RMS Frequency: 40Hz~1kHz Overload protection: 0.8A/600V, 15A/600V fuse Continuous testing the maximum steady-state current of 1A 2.2.5 Resistance 600Ω ± ( 1.0%+3 ) 0.1Ω 6kΩ 1Ω 60kΩ 10Ω ± ( 1.0%+2 ) 600kΩ 100Ω 6MΩ 1kΩ 60MΩ ± (1.5%+3 ) 10kΩ 4

2.2.6 Capacitance 9.999nF ± ( 3.0%+10 ) 1pF 99.99nF 10pF 999.9nF ± ( 2.5%+5 ) 100pF 9.999µF 1nF 99.99µF ± ( 5.0%+10 ) 10nF 999.9µF 100nF 9.999mF ± (10.0%+20) 1µF 99.99mF 10µF 2.2.7 Diode and Audible continuity test Range Description Test condition Display read approximately forward voltage of diode Forward DC current approx. 1.5mA Reversed DC voltage approx. 3.2V Built-in buzzer sounds if resistance is less than 50Ω 2.2.8 Frequency Open circuit voltage approx. 1V 9.999Hz 0.001Hz 99.99Hz 0.01Hz 999.9Hz 0.1Hz 9.999kHz ± ( 0.1%+5 ) 1Hz 99.99kHz 10Hz 999.9kHz 100Hz 9.999MHz 1kHz Sensitivity: sine wave 0.6V rms (9.999MHz: 1.5V rms) 2.2.9 Duty cycle 0.1%~99.9%: ± (2.0%+2) Frequency lower than 10kHz Sensitivity: sine wave 0.6V rms 2.2.10 Temperature -20~150 ± (3 +1) -4~302 ± (5 +2) / 1 /1 151~1000 ± (3%+2) 303~1832 ± (3%+3) NiCr-NiSi sensor 5

3. OPERATION 3.1 DC and AC Voltage Measurement 1) Connect the black test lead to "COM" socket and red test lead to the "VΩHz" socket. 2) Set the selector switch to desired mv or V position. 3) Press SELECT key to choose DC or AC measurement. 4) Measure the voltage by touch the test lead tips to the test circuit where the value of voltage is needed. 6) On AC range, press Hz/% key to measurement frequency or duty cycle. 3.2 DC and AC Current Measurement 1) Connect the black test lead to "COM" socket. For measurement up to 600mA, connect the red test lead to the "µama" socket; for measurement from 600mA to 15A, connect the red test lead to the "15A" socket. 2) Set the selector switch to desired µa ma or A position. 3) Press SELECT key to choose DC or AC measurement. 4) Remove power from the circuit under test and open the normal circuit path where the measurement is to be taken. Connect the meter in series with the circuit. 6) On AC range, press Hz/% key to measurement frequency or duty cycle. 3.3 Resistance Measurement 1) Connect the black test lead to "COM" socket and red test lead to the "VΩHz" socket. 2) Set the selector switch to desired position. 3) Connect tip of the test leads to the points where the value of the resistance is needed. 4) Read the result from the LCD panel. Note: When take resistance value from a circuit system, make sure the power is cut off and all capacitors need to be discharged. 3.4 Capacitance Measurement 1) Connect the black test lead to "COM" socket and red test lead to the "VΩHz" socket. 2) Set the selector switch to desired position. 3) Press SELECT key to choose Capacitance measurement. 4) Connect tip of the test leads to the points where the value of the capacitance is needed. Note: Before testing, discharge the capacitor by shorting its leads together. Use caution in handing capacitors because they may have a charge on them of considerable power before discharging. 6

3.5 Diode and Audible continuity Test 1) Connect the black test lead to "COM" socket and red test lead to the "VΩHz" socket. 2) Set the selector switch to desired position. 3) Press SELECT key to choose Diode or Audible continuity measurement. 4) Connect the test leads across the diode under measurement, display shows the approx. forward voltage of this diode. 5) Connect the test leads to two point of circuit, if the resistance is lower than approx. 50Ω, the buzzer sounds. Note: Make sure the power is cut off and all capacitors need to be discharged under this measurement. 3.6 Frequency and Duty cycle measurement 1) Connect the black test lead to "COM" socket and red test lead to the "VΩHz" socket. 2) Set the selector switch to desired Hz position. 3) Press Hz/% key to choose Frequency or Duty cycle measurement. 4) Connect the probe across the source or load under measurement. 3.7 Temperature Measurement 1) Connect the black banana plug of the sensor to "COM" socket and red banana plug to the "VΩHz" socket. 2) Set the selector switch to desired / position. 3) Press SELECT key to choose or measurement. 4) Put the sensor probe into the temperature field under measurement. 3.8 Data Hold On any range, press the key to lock display value, and the DH sign will appear on the display, press it again to exit. 3.9 Back Light On any range, press the key over 2 seconds to light the back light, press it again for more than 2 seconds to wink the light. 3.10 Relative measurement Press the REL key, you can measure the relative value and sign will appear on the display, the auto range mode is changed to manual range mode. Press it again to exit relative measurement and sign disappears, but you can not go back to auto range mode. This function is non effective on Hz/% measurement. 3.11 Auto/Manual range The auto range mode is a convenient function, but it might be faster to manually set the range when you measure values that you know to be within a certain range. 7

To select manual range, repeatedly press RANGE key until the display shows the desired range. The range steps upward as you press RANGE key. The meter will go back to auto range mode when you press RANGE key for more than 2 seconds. Caution: while using the manual range mode, if OL sign appears on the display, immediately set range to a higher. 4. Battery replacement 1) When the battery voltage drop below proper operation range, the symbol will appear on the LCD display and the batteries need to changed. 2) Before changing the battery, set the selector switch to OFF position. Open the cover of the battery cabinet by a screwdriver. 3) Replace the old battery with the same type battery. 4) Close the battery cabinet cover and fasten the screw. Caution: Dispose the used batteries according to the rules, which are defined by each community. Warning: If an explosion or fire hazard could occur through fitting a battery of the wrong type. 5. Fuse replacement 1) This meter is provided with a 0.8A/600V fuse to protect the battery test and the current measuring circuits which measure up to 600mA, with a 15A/600V fuse to protect the 15A range. 2) Ensure the instrument is not connected to any external circuit, set the selector switch to OFF position and remove the test leads from the terminals. 3) Remove the three screws on the bottom case and lift the bottom case. Replace the old fuse with the same type and rating: 5 20mm 0.8A/600V or 5 20mm 15A/600V fuse. 4) Close the bottom case and fasten the screws. 6. MAINTENANCE 1) Before open the battery cover, disconnect both test lead and never uses the meter before the battery cover is closed. 2) To avoid contamination or static damage, do not touch the circuit board without proper static protection. 3) If the meter is not going to be used for a long time, take out the battery and do not store the meter in high temperature or high humidity environment. 4) Repairs or servicing not covered in this manual should only by qualified personal. 5) Periodically wipe the case with a dry cloth and detergent. Do not use abrasives or solvents on the meter. 8

Distributed by MTi Victoria Road, Avonmouth, Bristol, BS11 9DB Tel: 0117 938 6400 Fax: 0117 923 5374 Email: enquiries.ethos@adivision.co.uk Web: www.ethos-instruments.co.uk 9