IOMAC'13 5 th International Operational Modal Analysis Conference

Similar documents
STRUCTURAL HEALTH MONITORING USING STRONG AND WEAK EARTHQUAKE MOTIONS

Identification of dynamic response parameters of a concrete building during recent earthquakes by using structural vibration monitoring

2166. Modal identification of Karun IV arch dam based on ambient vibration tests and seismic responses

IOMAC' May Guimarães - Portugal

University of Molise Engineering Faculty Dept. SAVA Engineering & Environment Section. C. Rainieri, G. Fabbrocino

Ambient and Forced Vibration Testing of a 13-Story Reinforced Concrete Building

Laboratory evaluation of a fully automatic modal identification algorithm using automatic hierarchical clustering approach

Dynamic Excitation Related Uncertainty in Ambient Vibration Testing of a Truss Bridge

IOMAC' May Guimarães - Portugal REAL-TIME STRUCTURAL HEALTH MONITORUN AND DAMAG DETECTION

Modal tracking with only a few of sensors: application to a residential building

IDENTIFICATION OF NONLINEAR SITE RESPONSE FROM TIME VARIATIONS OF THE PREDOMINANT FREQUENCY

Development of Optimal Experimental Design Parameters for Pseudo Ambient Vibration Testing of Bridges

Modal Parameter Identification of A Continuous Beam Bridge by Using Grouped Response Measurements

EXPERIMENTAL MODAL AND AERODYNAMIC ANALYSIS OF A LARGE SPAN CABLE-STAYED BRIDGE

An approach for decentralized mode estimation based on the Random Decrement method

Figure 1: The Penobscot Narrows Bridge in Maine, U.S.A. Figure 2: Arrangement of stay cables tested

VIBRATION ANALYSIS AND MODAL IDENTIFICATION OF A CIRCULAR CABLE-STAYED FOOTBRIDGE

A HARMONIC PEAK REDUCTION TECHNIQUE FOR OPERATIONAL MODAL ANALYSIS OF ROTATING MACHINERY

Modal identification using SMITM Minwoo Chang 1, Shamim N. Pakzad 2, and Rebecca Leonard 3,

IOMAC'15 DYNAMIC TESTING OF A HISTORICAL SLENDER BUILDING USING ACCELEROMETERS AND RADAR

Oscillation Monitoring with the PI Server for Large Power Systems

Current-Based Online Bearing Fault Diagnosis for Direct-Drive Wind Turbines via Spectrum Analysis and Impulse Detection

Structure Health Monitoring System Using MEMS-Applied Vibration Sensor

Oscillation Monitoring System - Damping Monitor -

Modal Testing of Mechanical Structures subject to Operational Excitation Forces

MODAL IDENTIFICATION OF BILL EMERSON BRIDGE

Response spectrum Time history Power Spectral Density, PSD

Spatial coherency of earthquake-induced ground accelerations recorded by 100-Station of Istanbul Rapid Response Network

How to perform transfer path analysis

Operational modal analysis applied to a horizontal washing machine: A comparative approach Sichani, Mahdi Teimouri; Mahjoob, Mohammad J.

Quality indicators for embedded stochastic subspace identification algorithms in wireless structural health monitoring systems

Microtremor Array Measurements and Three-component Microtremor Measurements in San Francisco Bay Area

TRAIN INDUCED SEISMIC NOISE OF ACCELERATING AND DECELERATING TRAIN SETS

Output Only Modal Testing of a Car Body Subject to Engine Excitation Brincker, Rune; Andersen, P.; Møller, N.

Convenient Structural Modal Analysis Using Noncontact Vision-Based Displacement Sensor

Calibration and Processing of Geophone Signals for Structural Vibration Measurements

Site-specific seismic hazard analysis

Comparison of Transmissibility of Non-Metallic Materials For Vibration Isolation

1319. A new method for spectral analysis of non-stationary signals from impact tests

Experimental Vibration-based Damage Detection in Aluminum Plates and Blocks Using Acoustic Emission Responses

Implementation and analysis of vibration measurements obtained from monitoring the Magdeburg water bridge

Non-contact structural vibration monitoring under varying environmental conditions

Vibration Fundamentals Training System

Influence of Peak Factors on Random Vibration Theory Based Site Response Analysis

Shinde Suyog Sudhakar, Galatage Abhijeet.A, Kulkarni Sumant.K, International Journal of Advance Research, Ideas and Innovations in Technology.

SHOCK AND VIBRATION RESPONSE SPECTRA COURSE Unit 4. Random Vibration Characteristics. By Tom Irvine

SDOF System: Obtaining the Frequency Response Function

Parallel data processing architectures for identification of structural modal properties using dense wireless sensor networks

Chapter 2 Real-Time Structural Health Monitoring and Damage Detection

IOMAC' May Guimarães - Portugal TIME-FREQUENCY ANALYSIS OF DISPERSIVE PHENOMENA IN BRIDGES

Preliminary study of the vibration displacement measurement by using strain gauge

Impact sound insulation: Transient power input from the rubber ball on locally reacting mass-spring systems

VIBRATIONAL TESTING OF A FULL-SCALE PILE GROUP IN SOFT CLAY

Mani V. Venkatasubramanian Washington State University Pullman WA

Borehole vibration response to hydraulic fracture pressure

CRITERIA FOR MATHEMATICAL MODEL SELECTION FOR SATELLITE VIBRO-ACOUSTIC ANALYSIS DEPENDING ON FREQUENCY RANGE

2015 HBM ncode Products User Group Meeting

What Can We Learn from High Quality Instrumentation in Structures? John Clinton

Mechanical Spectrum Analyzer in Silicon using Micromachined Accelerometers with Time-Varying Electrostatic Feedback

ANALYSIS ON RESPONSE OF DYNAMIC SYSTEMS TO PULSE SEQUENCES EXCITATION

EARTHQUAKE RESPONSE OF HIGHWAY BRIDGES SUBJECTED TO LONG DURATION SEISMIC MOTIONS. Kataoka Shojiro 1

EXPERIMENTAL ANALYSIS OF BOLT LOOSENING DYNAMICS CHARACTERISTIC IN A BEAM BY IMPACT TESTING

Monopile as Part of Aeroelastic Wind Turbine Simulation Code

MODEL MODIFICATION OF WIRA CENTER MEMBER BAR

Title: Reference-free Structural Health Monitoring for Detecting Delamination in Composite Plates

Research Article Long-Term Vibration Monitoring of Cable-Stayed Bridge Using Wireless Sensor Network

Experimental investigation of crack in aluminum cantilever beam using vibration monitoring technique

K L Rakshith, Smitha, International Journal of Advance Research, Ideas and Innovations in Technology.

DECENTRALISED ACTIVE VIBRATION CONTROL USING A REMOTE SENSING STRATEGY

WIND-INDUCED VIBRATION OF SLENDER STRUCTURES WITH TAPERED CIRCULAR CYLINDERS

Recent Advances to Obtain Real - time Displacements for Engineering Applications

Wind Turbine Analysis System - Type 3652 MKII & MKIII

BEAMFORMING WITHIN THE MODAL SOUND FIELD OF A VEHICLE INTERIOR

IOMAC' May Guimarães - Portugal TEMPERATURE AND TRAFFIC LOAD EFFECTS ON MODAL FREQUENCY FOR A PERMANENTLY MONITORED BRIDGE

Real-time Monitoring of Power Oscillations and Modal Damping in the European ENTSO-E System

732. Numerical and experimental identification of vibration convection chamber of fluid power boiler

Modal Testing of Mechanical Structures Subject to Operational Excitation Forces Møller, N.; Brincker, Rune; Herlufsen, H.; Andersen, P.

Identification of Delamination Damages in Concrete Structures Using Impact Response of Delaminated Concrete Section

Reference: PMU Data Event Detection

Th P6 01 Retrieval of the P- and S-velocity Structure of the Groningen Gas Reservoir Using Noise Interferometry

Solution of Pipeline Vibration Problems By New Field-Measurement Technique

Field Testing of Wireless Interactive Sensor Nodes

FATIGUE CRACK CHARACTERIZATION IN CONDUCTING SHEETS BY NON

A Dissertation Presented for the Doctor of Philosophy Degree. The University of Memphis

FAULT DIAGNOSIS AND RECONFIGURATION IN FLIGHT CONTROL SYSTEMS

DYNAMIC CHARACTERISTICS OF A BRIDGE ESTIMATED WITH NEW BOLT-TYPE SENSOR, AMBIENT VIBRATION MEASUREMENTS AND FINITE ELEMENT ANALYSIS

Enhanced Resonant Inspection Using Component Weight Compensation. Richard W. Bono and Gail R. Stultz The Modal Shop, Inc. Cincinnati, OH 45241

Non Destructive Testing & Modal Analysis for Seismic Risk Assessment

(i) Sine sweep (ii) Sine beat (iii) Time history (iv) Continuous sine

Wide-Area Measurements to Improve System Models and System Operation

high, thin-walled buildings in glass and steel

The vibration transmission loss at junctions including a column

Disturbance Rejection Using Self-Tuning ARMARKOV Adaptive Control with Simultaneous Identification

Non-Data Aided Doppler Shift Estimation for Underwater Acoustic Communication

A Novel Crack Location Method Based on the Reflection Coefficients of Guided Waves

Development of a Low Cost 3x3 Coupler. Mach-Zehnder Interferometric Optical Fibre Vibration. Sensor

BASICS OF MODAL TESTING AND ANALYSIS

Separation of Sine and Random Com ponents from Vibration Measurements

Dynamic Analysis & Correlation for Exhaust System

Fault detection of a spur gear using vibration signal with multivariable statistical parameters

Transcription:

IOMAC'13 5 th International Operational Modal Analysis Conference 2013 May 13-15 Guimarães - Portugal STRUCTURAL HEALTH MONITORING OF A MID HEIGHT BUILDING IN CHILE R. Boroschek 1, A. Aguilar 2, J. Basoalto 3 and P. León 4 ABSTRACT This article presents the Structural Health Monitoring of the Central Tower at the Faculty of Physical and Mathematical Science of the University of Chile. The building has been monitored since 2009 with a network of 8 uniaxial accelerometers and 17 environmental sensors which register ambient conditions, like wind speed and direction, temperature, rainfall, ambient and soil humidity. The building is a nine stories, 30 meters high, shear wall reinforced concrete structure. During this period, it has been continuously monitoring ambient vibrations and more than 1700 seismic events of different intensity. Modal parameters are obtained automatically with frequency and time identification methods applied over ambient vibrations records. Earthquakes records are analyzed with multiple input multiple output (MIMO) techniques. Results of the analysis have been published automatically on Internet since the beginning of measurements. This article also presents an analysis of the seismic records on the building during the Mw=8.8 2010 Chile earthquake. Structural Damage was observed on the building and modal parameters changes were identified. Keywords: Operational Modal Analysis, Earthquake, Automatic System Identification. 1. INTRODUCTION The instrumented building called Central Tower was constructed in 1962. It is located at the Engineering Faculty of the University of Chile and is used for office and classroom. It has 9 stories above ground and 2 underground levels. It has a total surface of 4,600 m2, approximately. It has a total height of 30.2 meters and a plan area 30 x 19 meters. Figure 1 shows some pictures of the building. The structural system consists on a reinforced concrete shear and gravity walls. Typical wall thickness is 35 cm and typical slab thickness is 25 cm. The typical ratio between total wall area to plan area is 7.7 % [1]. The building is instrumented with an array of 8 uniaxial accelerometers that allow the continuous recording of the structural response due to ambient vibrations and seismic events. Furthermore, it has 17 environmental sensors which detect and save the data obtained from ambient conditions, as wind 1 Structural Engineer, M. Sc., Ph. D. University of Chile, rborosch@ing.uchile.cl 2 Structural Engineer, Rubén Boroschek y Asociados, aaguilar.uribe@gmail.com 3 Engineering Student, Civil Engineering Department, University of Chile, jbasoal@ing.uchile.cl 4 Engineering Student, Civil Engineering Department, University of Chile, paleon@ing.uchile.cl

R. Boroschek, A. Aguilar, J. Basoalto, P. León speed and direction, temperature, rainfall, etc. All data is processed in a central and automatic system with different signals analysis techniques and their results are real time reported on a web site. Modal parameters are identified with these methods and the dynamic structural behavior is correlated with environmental changes like temperature and humidity changes. The system also can detect and process earthquakes records and report the modal parameters changes due to structural damage or modification, working as a non-common response identification and alert system. Figure 1 Torre Central - General Views. All records are saved and backed up, so it can be used for new identification techniques tests, which can be contrasted with theoretical models or experimental results. This article presents a brief description of the instrumentation, recording process and internet report, but also it is centered on the effects of the 8.8 Magnitude Chilean earthquake of 2010. 2. SENSOR ARRAY AND WEB REPORT The monitoring system has 8 accelerometers, with two parallel acquisition systems: the first one for seismic records without amplification and with a trigger configuration; the second with amplification of 10 for ambient vibrations. The accelerometer location is shown in Figure 2 [1, 2]. Figure 2 Sensor Location

5 th International Operational Modal Analysis Conference, Guimarães 13-15 May 2013 Additionally, three humidity sensors have been installed in a borehole in the west side of the building. The humidity sensors are located at 20, 10 and 5 meters below the surface and they are connected to the accelerometers data acquisition system, Figure 3 (a) and (b). The monitoring system also acquires information from a meteorology station located at a close by building roof and maintained by the Meteorology Group of the Department of Geophysics at the University of Chile, Fig 3 (c). Every 15 minutes the station collects data from temperature, precipitation and wind speed, among others. Figure 3 Sensors: (a) schematic dwell location, (b) well, humidity sensors and (c) meteorology station. The structural health monitoring system stores and process all data recorded every 15 minutes in a high capacity computer, controlled by the acquisition system. The acquisition system is configured to obtain continuous records of 15 minutes duration, in 100 Hz sampling frequency files. Data processing is done using three system identification techniques to determine modal parameters: Peak Peaking (PSD analysis) and Stochastic Sub Space Identification (SSI), both for ambient vibrations processing. A Multiple Input Multiple Output technique (MIMO) process is applied on the seismic events. The results are synchronized with a server at the Civil Engineering Department and published on Internet 5. Figure 4 shows the monitoring workflow. Figure 4 Monitoring Service Workflow [2]. 3. SYSTEM IDENTIFICATION TECHNIQUES The SSI technique developed by Van Overschee and De Moor [3, 4, and 5] uses the stochastic space model, described by the equations system (1). This technique identifies modal properties from output only response signals. x A x w k 1 k k y C x v k k k (1) Eq. (1) constitutes the basis for time-domain modal identification through ambient vibration measurements. There are several techniques and algorithms to obtain modal parameters from the stochastic subspace model [3]. The algorithms to identify the state-space matrices ( A, C ) are based 5 www.ingcivil.uchile.cl/shm

R. Boroschek, A. Aguilar, J. Basoalto, P. León on the measurements and by robust numerical techniques, such as QR factorization, singular value decomposition (SVD), and least squares [5]. Once the mathematical description of the structure is found, modal parameters such as frequency, i damping ratio i and operational mode shapes, are determined as: real ln i * i i i i i i i t i C (2) To corroborate the results, the Power Spectrum Density (PSD) method is used. To identify the dynamic properties of the building during earthquake excitations an equivalent parametric viscoelastic model is used and adjusted using the MOESP (Multivariable Output-Error State Space) system identification method [6]. In this method the state space equilibrium and observation equations are given by: (3) Considering that every step {z k } can be expressed as a function of previous values, the relation with {y k } can be written as: (4) (5) where is the extended observability matrix with order s and is a Toeplitz matrix. Given that [O s ] depends on [A] it is possible to obtain from this matrix the natural properties of the structure [6]. 4. MODAL PARAMETERS VARIATIONS DUE TO THE MW=8.8 EARTHQUAKE 4.1. Results of remote-continuous monitoring. Ambient vibrations Since April 2009, continuous monitoring has been developed under ambient vibrations, calculating the first three modal parameters every 15 minutes. In the period corresponding between June 2009 and December 2011 near 90,000 data vibration were registered and processed to obtain these frequencies and they are plotted in Figure 5. In this figure the variation of predominant frequency due to the earthquake of February 2010 is clearly notice by a drop on the frequency values. (The system stops working during the month of February 2011).

Frequency (Hz) 5 th International Operational Modal Analysis Conference, Guimarães 13-15 May 2013 3.2 3 U. DE CHILE - SHM: CENTRAL TOWER - FCFM - PSD f1 f2 f3 2.8 2.6 2.4 2.2 2 1.8 1.6 06-09 09-09 12-09 03-10 06-10 09-10 12-10 03-11 06-11 09-11 12-11 Date (mm-yy) Figure 5 Firsts three natural frequencies. For each data record an automatic identification of frequencies, damping ratios and modal shapes through two methods, PSD (Power Spectral Density) and SSI (Stochastic Sub-Space Identification) is performed. The mean and standard deviation of the first three modal frequencies obtained with PSD method, before and after the last Chilean earthquake, are shown in Table 1. The modal parameters variations during the earthquake are not included in this statistic. Additionally, Figure 6 shows the histogram of both periods of time for these frequencies. Table 1 Frequency values obtained by PSD methods and comparison before and after 27F Maule earthquake PRE 27F POST 27F Mode Standard Standard Difference f [Hz] Deviation f [Hz] Deviation [%] [%] [%] 1 2,24 2,16 1,909 2,16 14,62 2 2,62 1,94 2,321 2,28 11,52 3 2,98 2,72 2,734 3,56 8,19 Mean Value 11,44

Observations Observations Observations R. Boroschek, A. Aguilar, J. Basoalto, P. León 6000 4000 2000 U. OF CHILE - SHM: CENTRAL TOWER - FCFM - PSD - PRE27F - Hist. f1 0 1.6 1.7 1.8 1.9 2 2.1 2.2 2.3 2.4 2.5 Frequency 1 (Hz) Post 27F Mean: 1.909 Std.: 0.022 Pre 27F Mean: 2.235 Std.: 0.022 6000 4000 2000 U. OF CHILE - SHM: CENTRAL TOWER - FCFM - PSD - PRE27F - Hist. f2 0 2 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 Frequency 2 (Hz) Post 27F Mean: 2.321 Std.: 0.023 Pre 27F Mean: 2.624 Std.: 0.019 4000 2000 0 U. OF CHILE - SHM: CENTRAL TOWER - FCFM - PSD - PRE27F - Hist. f3 2.5 2.6 2.7 2.8 2.9 3 3.1 3.2 3.3 Frequency 3 (Hz) Post 27F Mean: 2.734 Std.: 0.036 Pre 27F Mean: 2.978 Std.: 0.027 Figure 6 Histograms of first three frequencies derived from ambient vibrations before and after 27F Maule earthquake. After the Mw=8.8 Chilean earthquake, light structural damage occurred in the structure. It is possible to observe a decrease of 11.4% in the average value for the first three frequencies when the building is subjected to ambient vibrations. Nevertheless, instant decrease of the average frequencies immediately after the earthquake was 16.6%. 4.2. Results of remote-seismic event monitoring. Since its implementation in 2009, the Structural Health Monitoring System has been recorded about 1,750 seismic events, including the Central-South Chile Mw = 8.8 earthquake recorded on February 27 th, 2010. These seismic events provided additional and important information for this system. Figure 7 shows modal frequency histograms obtained from earthquakes recorded since 2009 until end of 2011. It can be observed the huge difference between the amount of events post the February 27th earthquake and recorded previus events, mainly due to the high number of aftershocks and the longer observation period. The major seismic event produced structural damage, causing a decrease in the building stiffness, resulting in the reduction of the identified modal frequencies. It s interesting to note that after the earthquake, despite the variability determined by different intensities for each seismic event, frequencies remain within a defined range, without overlapping the values identified before the earthquake. However, observed damages in the structure because of the earthquake was considered light. No important structural deterioration was noted by visual inspections.

5 th International Operational Modal Analysis Conference, Guimarães 13-15 May 2013 Figure 7 Distribution of modal frequencies in seismic events of different intensities. An statistical description of each distribution is made in Table 2. As it can be noted, the same three natural frequencies were observed before the Mw=8.8 Chilean earthquake. Small seismic event frequency are no more than 1.3% lower than those determined by ambients vibration records. The largest variations in modal frequencies after the main earthquake were produced in modes 1st, 2nd and 4th. All cases show a reduction on their values larger than 10%, with the exception of the 3rd and 7th modes. The first mode change was 16.4% followed by the 4th, which experimented a decrease of 14.2 %. Despite this, the third mode shows the highest variation in the standard desviation of its frequency distribution after the event (66.6 %), which indicates that this mode was more afected by the seismic motions. The permanent decrease in natural frequencies is evidence of structural modification or damage. This fact helps to support the need to maintain a continous structural health control and monitoring that could alert dynamic structural parameters changes. Variability in frequencies distributions is larger post the earthquake. These can be explained by the quantity of aftershocks, seismic events intensities and structural damage.

R. Boroschek, A. Aguilar, J. Basoalto, P. León Mode Mean f [Hz] Table 2 Mean and standard deviations for each modal frequency. Pre 27F Post 27F Variation Standard Standard Mean f Deviation Deviation [Hz] [Hz] [Hz] Mean f [%] St. Dev. [%] 1 2,21 0,03 1,85 0,04-16,4 33.3 2 2,60 0,03 2,26 0,04-12,9 33.3 3 2,95 0,03 2,67 0,05-9,6 66.6 4 6,26 0,07 5,37 0,10-14,2 42.9 5 7,45 0,09 6,63 0,14-11,1 55.6 6 7,96 0,14 7,13 0,20-10,4 42.9 7 9,00 0,09 8,26 0,13-8,2 44.4 Figure 8 shows modal damping ratio histograms obtained from MIMO identification process. No significant changes were observed in the modal damping ratios due to the damage. Figure 8 Distribution of modal damping ratios in seismic events. A statistical description of each distribution is made in Table 3. As it can be noted that after the Mw=8.8 Chilean earthquake, all modal damping ratios increased except for the 4th mode. The larges change was produced in the second mode, which increased over 29%. These variations can be explained in the increment of contact surface due to structural damage, which can be related with the structural dissipation mechanisms but also seismic intensities. The effect of intesity is now under investigation.

5 th International Operational Modal Analysis Conference, Guimarães 13-15 May 2013 Mode Table 3 Mean and standard deviations for each modal damping ratio. Mean [%] Pre 27F Post 27F Variation Standard Standard Mean Deviation Deviation [%] [%] [%] Mean [%] St. Dev. [%] 1 1,18 0,60 1,32 0,61 11,1 1.7 2 1,11 0,56 1,44 0,72 29,3 28.6 3 1,07 0,54 1,36 0,64 27,5 18.5 4 1,53 0,49 1,36 0,44-11,4-10.2 5 1,76 0,68 1,82 0,69 3,3 1.5 6 3,21 1,93 3,72 2,27 15,9 17.6 7 1,86 0,71 2,12 0,84 13,9 13.0 The variations of the modal damping standard deviations was found larger than 10% for most of the modes. 5. CONCLUSIONS A continuous automatic monitoring and modal identification system has been implemented at the Faculty of Physical and Mathematical Science of the University of Chile since 2009. Over 90,000 ambient vibrations records and over 1,750 seismic records have been recorded and processed by the system. The identification includes modal properties and the building response including the sixth largest magnitude earthquake of the world. An analysis of modal frequencies and modal damping ratios was done, showing that a significant reduction in all natural frequencies was caused by the earthquake. The combination between technologies and structural diagnosis allow the system to publish its state of health continuously and report its changes in dynamic properties. One of the largest recorded earthquakes of the world had proven the effectiveness of the system. ACKNOWLEDGEMENTS The Civil Engineering Department of the University of Chile and the Chilean Council for Research and Technology, CONICYT Fondecyt Project # 1070319 supported this research paper. The support of Engineer Pedro Soto is greatly appreciated. This research was part of the individual works for Engineer Thesis of Julio Basoalto and Pablo León, both undergraduate students of the University of Chile. REFERENCES [1] Yañez T. (2009) Implementación de un Sistema de monitoreo continuo de parámetros dinámicos de un edificio de muros, Thesis in fulfillment of the requirements for the degree of Civil Engineer, Universidad de Chile. [2] Boroschek R., Núñez T. and Yañez T. (2010) Development of a real time internet based monitoring system in a nine story, shear wall building, Proc. 14 European Conference of Earthquake Engineering, Ohrid, Macedonia. [3] Van Overschee P. and De Moor B. (1993) Subspace algorithms for the stochastic identification problem. Automatica, Vol. 29, no. 3, pp. 649-660.. [4] Van Overschee P. and De Moor B. (1994) N4SID: Subspace Algorithms for the identification of Combined Deterministic-Stochastic Systems. Automatica, Special Issue on Statistical Signal Processing and Control, Vol 30, no. 1, pp. 75-93. [5] Van Overschee P. and De Moor B. (1996) Subspace Identification for Linear Systems: Theory- Implementation- Applications. Kluwer Academic Publishers, Dordrecht, The Netherlands.

R. Boroschek, A. Aguilar, J. Basoalto, P. León [6] Yoshimoto, R., Mita, A., Keiichi Okada, K. (2005) Damage detection of base-isolated buildings using multi-input multi-output subspace identification. Earthquake Engng Struct. Dyn., 34:307-324.