Fluke 170 Series True-rms Digital Multimeters

Fluke T5 Electrical Testers. Fluke T and T5-600 Voltage, Continuity and Current Testers

1587/1577 Insulation Multimeters

1507/1503. Insulation Testers. Technical Data. Features and benefits:

Fluke 83V and 87V Digital Multimeters

Fluke 1587 FC/1577 Insulation Multimeters

Digital multimeter selection guide

Fluke 1660 Series Multifunction Installation Testers

n/a FLUKE 116 MULTIMETER

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

79/26 Series III Multimeter

Fluke Digital Multimeters Solutions for every need

Insulation resistance testing. A complete solution for every application

Digital multimeter selection guide

114, 115, and 117. True-rms Multimeters. Users Manual

114, 115, and 117. True-rms Multimeters

Electrical Multimeter

374/375/376 Clamp Meter

Fluke 170 Series True-rms Digital Multimeter Extended Specifications

Analog Technologies. Multimeter 115C and 117C

374/375/376 Clamp Meter

5320A. Multifunction Electrical Tester Calibrator. Extended Specifications

+/- (3 PERCENT +2) AC VOLTAGE, +/- (2 PERCENT +2) DC VOLTAGE, +/- (5 PERCENT +3) RESISTANCE. User Manual, Test Lead Wrap, TP2 Test Probes

Model 77 Series IV. Digital Multimeter. Users Manual

Measure voltage without test leads. Product Highlights

Fluke 712B and 714B Temperature Calibrators

Fluke 8845A/8846A Digital Multimeters Extended Specifications

1650 Series Multifunction Installation Testers

The future of installation testing is here. The Fluke 1650 Series Multifunction Testers

374 FC/375 FC/376 FC Clamp Meter

Fluke 355 and 353 True-rms 2000 A Clamp Meters Versatile and rugged tools for applications with high currents

Model 77 Series IV. Digital Multimeter. Users Manual

15B & 17B. Multimeters. Users Manual

Insulation Testers and Earth Ground Testers

With any other power quality analyzer you re just wasting energy.

Fluke 345. Power Quality Clamp Meter. The ideal meter for commissioning and troubleshooting modern electrical loads

True-rms Multimeter. Users Manual

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

True-rms Multimeter. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com

Models 110, 111 & 112

12B/18 MultiMeter Instruction Sheet

374/375/376 Clamp Meter

Pinpoint power quality problems faster

15B & 17B. Users Manual. Multimeters

ENGLISH. Datasheet Stock No RS PRO IDM 99III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph

Analog Technologies. Multimeter 15B and17b

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

ENGLISH. Datasheet Stock No RS PRO IDM 98III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph

The future of installation testing is here. The 1650 Series Multifunction Testers

Data sheet IDM 99III Digital Multimeter

Clamp Meter ABCs. Application Note. The transformer action

Electrical Multimeter

Model 77 Series IV. Digital Multimeter. Users Manual

Data sheet IDM 98III Digital Multimeter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Insulation resistance testing. A complete solution for every application.

Electrical and HVAC Test Tools

Pinpoint power quality problems faster

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

312, 316, 318. Clamp Meter. Users Manual

374/375/376 Clamp Meter. Users Manual

Fluke 1660 Series Multifunction Installation Testers

Agilent 970-Series Handheld Multimeters Data Sheet

Instruction Manual IDM 98-III & IDM 99-III Digital Multimeters

Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators Extended Specifications

Fluke 370 FC Series true-rms wireless AC/DC clamp meters

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

SUBJECT TO CHANGE WITHOUT NOTICE

8845A/8846A 6.5 Digit Precision Multimeters

1650 Series Multifunction Installation Testers

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

Insulation Testing. Distributor Training Program

Tested Tough. Trusted Safe.

175, 177, 179. True-rms Multimeters. Users Manual

80 Series III. Multimeters. Getting Started

Fluke and

AC/DC CLAMP METER USER S MANUAL

5790A Automated AC Measurement Standard

Insulation resistance testing. A complete solution for every person.

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

Oscilloscope Calibration Options for 55XX Series Multi-Product Calibrators

netzerotools.com 374/375/376 Users Manual Clamp Meter

323/324/325 Clamp Meter

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

NOTE: Fully read and understand this manual before using this Digital Multimeter.

ABCs of DMMs. Multimeter features and functions explained. Application Note. Introduction. Choosing your DMM. Some basics

Fluke digital multimeters. Solutions for every need

GAMMA 20 DIGITAL MULTIMETER

34XR Digital Multimeter. Users Manual

400Amp True RMS AC/DC Clamp Meter Model EX613

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

Fluke 3540 FC Three-Phase Power Monitor

IDM 98-III & IDM 99-III Digital Multimeters

5080A Multi-Product Calibrator

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

80i-110s. AC/DC Current Probe Instructions. Introduction

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

PROCESS TOOLS SELECTION GUIDE

Transcription:

Installation Tester and DMM Kits Kit Contents: Part Number FLUKE-1652C-CLAMPKIT FLUKE-1652C05-CLAMPKIT FLUKE-1653B-CLAMPKIT/D FLUKE-1653B02-CLAMPKIT/D FLUKE-1654B-CLAMPKIT/D FLUKE-1654B02-CLAMPKIT/D FLUKE-117/TL175/SB Kit Contents FLUKE 1652C Installation Tester and Fluke 323 Clamp Meter UK Kit FLUKE 1652C Installation Tester and Fluke 323 Clamp Meter EU Kit FLUKE 1653B Installation Tester and Fluke 324 Clamp Meter UK Kit FLUKE 1653B Installation Tester and Fluke 324 Clamp Meter EU Kit FLUKE 1654B Installation Tester and Fluke 325 Clamp Meter UK Kit FLUKE 1654B Installation Tester and Fluke 325 Clamp Meter EU Kit Fluke 117 Digital Multimeter, TL175 Test Lead Set and SB Bluetooth Speaker See below for individual parts datasheets. Contact Information: www.farnell.co.uk www.newark.com www.fluke.com

Fluke 117 Electrician s Multimeter with Non-Contact Voltage Technical Data Compact true-rms meter for commercial applications The Fluke 117 is the ideal meter for demanding settings like commercial buildings, hospitals and schools. The 117 includes integrated non-contact voltage detection to help get the job done faster. Features include: VoltAlert technology for non-contact voltage detection AutoVolt automatic ac/dc voltage selection LoZ: helps prevent false readings due to ghost voltage Large white LED backlight to work in poorly lit areas True-rms for accurate measurements on non-linear loads Measures 10 A (20 A overload for 30 seconds) Resistance, continuity, frequency and capacitance Min/Max/Average to record signal fluctuations Compatible with optional magnetic hanger (ToolPak ) for hands free operation CAT III 600 V safety rated Actual size R N10140 General specifications Accuracy is specified for 1 year after calibration, at operating temperatures of 18 C to 28 C, with relative humidity at 0 % to 90 %. The accuracy specifications take the form of: ± ( [ % of reading ] + [ counts ] ) Maximum voltage between any 600 V terminal and earth ground Surge protection 6 kv peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 Fuse for A input 11 A, 1000 V FAST Fuse (Fluke PN 803293) Display Digital: 6,000 counts, updates 4/sec Bar graph 33 segments, updates 32/sec Operating temperature -10 C to + 50 C Storage temperature -40 C to + 60 C Battery 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 Battery life 400 hours typical, without backlight

Accuracy specifications Measurement Range Resolution Accuracy ± ([% of reading] + [counts]) DC millivolts 600.0 mv 0.1 mv 0.5 % + 2 DC volts 6.000 V 0.001 V 60.00 V 0.01 V 600.0 V 0.1 V 0.5 % + 2 Auto volts 600.0 V 0.1 V 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 khz) AC millivolts 1 true-rms 600.0 mv 0.1 mv 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 khz) Ordering information Fluke-117 Electrician s Multimeter with Non-Contact Voltage Included TL75 Test leads, holster, User s manual and 9 V battery (installed). AC volts 1 true-rms 6.000 V 0.001 V 60.00 V 0.01 V 600.0 V 0.1 V 1.0 % + 3 (45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 khz) Continuity 600 Ω 1 Ω Beeper on < 20 Ω off > 250 Ω; detects opens or shorts of 500 µs or longer. Ohms 600.0 Ω 0.1Ω 0.9 % + 2 6.000 kω 0.001 kω 60.00 kω 0.01 kω 600.0 kω 0.1 kω 0.9 % + 1 6.000 MΩ 0.001 MΩ 40.00 MΩ 0.01 MΩ 1.5 % + 2 Diode test 2.000 V 0.001 V 0.9 % + 2 Capacitance 1000 nf 1 nf 10.00 µf 0.01 µf 1.9 % + 2 100.0 µf 0.1 µf 9999 µf 1 µf 100 µf to 1000 µf 1.9 % + 2 > 1000 µf 5 % + 20 Lo-Z capacitance 1 nf to 500 µf 10 % + 2 typical AC amps true-rms (45 Hz to 500 Hz) 6.000 A 0.001 A 10.00 A 0.01 A 20 A overload for 30 seconds max. 1.5 % + 3 DC amps 6.000 A 0.001 A 10.00 A 0.01 A 1.0 % + 3 20 A overload for 30 seconds max. Hz (V or A input) 2 99.99 Hz 0.01 Hz 999.9 Hz 0.1 Hz 9.999 khz 0.001 khz 50.00 khz 0.01 khz 0.1 % + 2 Notes: 1 All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display nonzero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mv are dc-coupled. 2 Frequency is ac coupled, 5 Hz to 50 khz for ac voltage. Frequency is dc coupled, 45 Hz to 5 khz for ac current. 2 Fluke Corporation 117 Electrician s Multimeter with Non-Contact Voltage Fluke. Keeping your world up and running. Fluke Corporation PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com 2006 Fluke Corporation. All rights reserved. Specifications subject to change without notice. Printed in U.S.A. 10/2006 2634028 D-EN-N Rev B

New Fluke TL175 TwistGuard Test Leads Twist. Test. TL175 TwistGuard Test Leads offer: Patented TwistGuard extendable tip shroud that meets new electrical safety requirements to reduce tip exposure while providing the versatility needed for most measurements New WearGuard lead wire wear indicator. Each test lead is covered by two layers of silicone insulation; inner contrasting color is exposed when the leads are nicked, scuffed, or otherwise damaged and in need of replacement Double insulated silicone leads. TL175 withstands high temperatures and remains flexible in cold temperatures Extra-heavy strain relief on both probe-end and plug-end, tested beyond 30,000 bends without failure Universal input plugs compatible with all instruments that accept standard 4 mm shrouded banana plugs Probes always show correct category rating for tip exposure being used TL175E also available. Includes removable 4 mm lantern tips for versatility Conforms to EN61010-031:2008 Ratings: CAT II 1000 V, CAT III 1000 V, CAT IV 600 V, 10 A max., Pollution Degree 2 Environmental ratings: -20 C to 55 C, altitude: 2000 m The new Fluke TL175 TwistGuard Test Leads are the only test leads in the world with adjustable length test tips for use in different measurement environments. By simply twisting the test lead the user can change the exposed probe tip length from 19 mm to 4 mm. TwistTest

TL175 TwistGuard Test Leads Reduce tip exposure for accurate placement Extreme strain relief tested to withstand over 30,000 bends Increase tip exposure for CAT II probing Universal plugs compatible with all 4 mm shrouded inputs Reduce tip exposure for CAT III testing WearGuard TM indicator shows insulation damage Regulation requirements On March 1st 2011 a new European safety standard EN 61010-031 for test leads and accessories has become valid. This new standard affects test leads and accessories, for all kind of test instruments, i. e. multimeter, clamps, insulation testers, Two of the major requirements of this standard are: 1.) For CAT III and CAT IV rated accessories the conductive metal parts must be below 4 mm 2.) Requirement about duration of the insulation of the test leads, either by a wear indicator or double insulation after lifetime wear The new test lead Fluke TL175 are fully compliant to this new regulation, and allows you to use the accessory in CAT III and CAT IV environments. Ordering information Model TL175 TwistGuard TM Test Leads, 2mm dia probe tips TL175E TwistGuard TM Test Leads, 2mm dia probe tips with 4mm adapters Fluke. Keeping your world up and running. Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands Web: www.fluke.eu For more information call: In Europe/M-East/Africa +31 (0)40 2 675 200 or Fax +31 (0)40 2 675 222 Fluke (UK) Ltd. 52 Hurricane Way Norwich, Norfolk NR6 6JB United Kingdom Tel.: (020) 7942 0700 Fax: (020) 7942 0701 E-mail: industrial@uk.fluke.nl Web: www.fluke.co.uk 2010, 2011 Fluke Corporation. Specifications subject to change without notice. Pub_ID: 11774-eng Modification of this document is not permitted without written permission from Fluke Corporation.