PSM Soft. Features and Functions January PC Software Guide. Getting connected and Communication

Similar documents
PSM3750 START UP GUIDE

Multi-function Gain-Phase Analyzer (Frequency Response Analyzer) Model 2505

Laboratory Experiment #1 Introduction to Spectral Analysis

An Introductory Guide to Circuit Simulation using NI Multisim 12

Explanation of options and accessories for the GP102 and GP102 -PAV

SIGNAL RECOVERY. Model 7265 DSP Lock-in Amplifier

Standalone High Accuracy Transformer Analysis. Basic 0.02dB with class leading high frequency performance. RS232, USB and LAN as standard

Fig. 1. NI Elvis System

Bode 100. User Manual

ECE 4670 Spring 2014 Lab 1 Linear System Characteristics

LAB I. INTRODUCTION TO LAB EQUIPMENT

ECE3204 D2015 Lab 1. See suggested breadboard configuration on following page!

ECE 6416 Low-Noise Electronics Orientation Experiment

ET 304A Laboratory Tutorial-Circuitmaker For Transient and Frequency Analysis

Experiment 1.A. Working with Lab Equipment. ECEN 2270 Electronics Design Laboratory 1

Spectrum Analyzer R&S FS300

Smart Measurement Solutions. Bode 100. User Manual

ME 365 EXPERIMENT 1 FAMILIARIZATION WITH COMMONLY USED INSTRUMENTATION

Measurement of the equivalent circuit of quartz crystals

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

3.2 Measuring Frequency Response Of Low-Pass Filter :

EE 201 Lab! Tektronix 3021B function generator

TEST & MEASURING INSTRUMENTS. Analyzer. (4 Ports) 4 Ports

Measure Low Value Impedance Current Shunt Impedance

PPA45xx series START UP GUIDE

UCE-DSO210 DIGITAL OSCILLOSCOPE USER MANUAL. FATIH GENÇ UCORE ELECTRONICS REV1

AV3672 Series Vector Network Analyzer

Lab #5 Steady State Power Analysis

The object of this experiment is to become familiar with the instruments used in the low noise laboratory.

FREQUENCY RESPONSE ANALYZERS

Low_Pass_Filter_1st_Order -- Overview

9063-RC Data Acquisition and Control Interface

U1604A Handheld Oscilloscopes, 40 MHz

WaveStation Function/Arbitrary Waveform Generators

LAB I. INTRODUCTION TO LAB EQUIPMENT

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

Impedance 50 (75 connectors via adapters)

APPLICATION NOTE 33 Battery Cell Electrochemical Impedance Spectroscopy N4L PSM3750 Impedance Analyzer + BATT470m Current Shunt

WaveStation Function/Arbitrary Waveform Generators

PSM PsimetriQ USER MANUAL. Issue 2.0

Frequency and Time Domain Representation of Sinusoidal Signals

EECS40 RLC Lab guide

MultiSim and Analog Discovery 2 Manual

SAMPLE: EXPERIMENT 2 Series RLC Circuit / Bode Plot

ArbStudio Arbitrary Waveform Generators. Powerful, Versatile Waveform Creation

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

EXPERIMENT NUMBER 10 TRANSIENT ANALYSIS USING PSPICE

Low Value Impedance Measurement using the Voltage / Current Method

Battery Impedance Measurement

Magnitude and Phase Measurements. Analog Discovery

Handheld Digital Storage Oscilloscopes 2510 Series

WaveStation Function/Arbitrary Waveform Generators

Test No. 1. Introduction to Scope Measurements. Report History. University of Applied Sciences Hamburg. Last chance!! EEL2 No 1

Figure AC circuit to be analyzed.

Use of the LTI Viewer and MUX Block in Simulink

Experiment 8: An AC Circuit

Sefram. Sefram SEFRAM A new family of thermal recorders 6 to 36 channels. Make sure to visit our Website

AC Measurements with the Agilent 54622D Oscilloscope

Technical note. Impedance analysis techniques

Power Supply Rejection Ratio Measurement

Figure E2-1 The complete circuit showing the oscilloscope and Bode plotter.

Precision Power Analyzers

OPERATIONAL AMPLIFIERS LAB

Lab 3: Very Brief Introduction to Micro-Cap SPICE

A Walk Through the MSA Software Vector Network Analyzer Transmission Mode 12/18/09

EENG-201 Experiment # 4: Function Generator, Oscilloscope

2026Q CDMA/GSM Interferer MultiSource Generator

PHYS 3322 Modern Laboratory Methods I AC R, RC, and RL Circuits

Introduction to basic laboratory instruments

DC/DC Converter Stability Measurement

Reference Design: Subwoofer Signal Conditioner

Lab 9 Frequency Domain

Integrators, differentiators, and simple filters

SFRA45 QUICK MEASUREMENT GUIDE

Arbitrary/Function Waveform Generators 4075B Series

Pre-Lab. Introduction

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Model and

HAMEG Modular System Series 8000

EE2210 Laboratory Project 1 Fall 2013 Function Generator and Oscilloscope

EE354 Spring 2016 Lab 1: Introduction to Lab Equipment

Dayton Audio is proud to introduce DATS V2, the best tool ever for accurately measuring loudspeaker driver parameters in seconds.

AC+DC Power Sources. Newtons4th Ltd. N4A06-6kVA Single Phase N4A18-18kVA Three Phase N4A30-30kVA Three Phase Higher Power Systems also Available

Dayton Audio is proud to introduce DATS V2, the best tool ever for accurately measuring loudspeaker driver parameters in seconds.

Lab 1B LabVIEW Filter Signal

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications

Laboratory Exercise 6 THE OSCILLOSCOPE

Real-Time FFT Analyser - Functional Specification

Basic Communication Laboratory Manual. Shimshon Levy&Harael Mualem

Equivalent Circuit Determination of Quartz Crystals

DEPARTMENT OF INFORMATION ENGINEERING. Test No. 1. Introduction to Scope Measurements. 1. Correction. Term Correction. Term...

SigCal32 User s Guide Version 3.0

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

Portable Multi-Channel Recorder Model DAS240-BAT

Bench LCR Meter Model 891

RLC-circuits with Cobra4 Xpert-Link

ECE4902 Lab 5 Simulation. Simulation. Export data for use in other software tools (e.g. MATLAB or excel) to compare measured data with simulation

Transfer Function (TRF)

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

1. Hand Calculations (in a manner suitable for submission) For the circuit in Fig. 1 with f = 7.2 khz and a source vin () t 1.

Transcription:

PSM Soft PC Software Guide Features and Functions January 2010 The PSM series Phase Sensitive Multimeters provide a wide range of exceptionally accurate and versatile instrumentation in one unique package. These applications can be accessed by either direct local front panel operation, or remotely by using the PSM Soft PC software. The software format is particularly suited to electrochemical analysis however, that does not mean other areas of analysis cannot be expertly conducted also. PSM Soft conveniently utilizes all available functions and by using this guide, in conjunction with the instrument user manual, steps through the main software operating windows whilst becoming familiar with its use. By using PSM Soft, interfacing the PC and the instrument could not be easier, using a general USB or RS232 communication port allows direct access whilst providing convenient data storage for further analysis. Getting connected and Communication PC Connection When first executing PSM Soft, the Frequency Response Analyser (FRA) default window will appear. From the main toolbar select Connection and then interface. The connection window will appear and allow the appropriate port and communication configuration to be set. Once configured, select Communication Test and confirm the instrument identification appears, select ok. The instrument is now ready for use with the open FRA window in view.

Permanently Displayed Generator and Summary Sections Generator Control Section The Frequency Generator control panel is available in all modes of operation. Amplitude, DC Voltage Offset and Frequency can be adjusted either by selecting the appropriate option widow arrows or by inserting the required parameter. The Waveform type has to be selected by the arrows, whilst the generator is activated by selecting the On/Off button. Configuration Summary Section The Configuration Summary section is available in all modes of operation and provides a guide to the main configuration setup. The configuration windows are selectable from the main toolbar and are described in more detail below. Accessing these windows allows such items as the Acquisition and Ranging parameters for the instrument to be set or adjusted. Toolbar Selected Configurations Windows Acquisition Window (Toolbar-Configuration-Acquisition) This window sets the measurement control and display presentation of the input signals. Each setting can be selected by selecting the box arrows and the relevant pop-up menu option. In the right hand set of boxes use the box arrows or insert an appropriate value, when finished select validation OK. Ranging Window (Toolbar-Configuration-Ranging) This window is used for setting Channel 1 and Channel 2 input parameters. It provides the means to set the coupling type, shunt values and the input connections used. Auxiliary fixtures are also selected from this window and appropriate parameters are selected using the box arrows and pop-up menu option, when finished select validation OK.

Alarm Window (Toolbar-Configuration-Alarm) This window is used for the Alarm control. Alarm monitor data can be set using the zoom menus whilst activation can be set using the threshold data boxes. Also using this window, the rear instrument BNC analogue output voltage can be enabled and controlled for external use. Main Modes of Operation FRA Mode Selecting the Frequency Response Analyser tab will enable the FRA mode. The instrument will analyse the gain and phase between channel 1 and 2 and present the information in the main display window. As can be seen the circuit analysis shows the CH1 & CH2 magnitudes with an attenuation of -15.4dB and a phase angle of -78.9 at a frequency of 5KHz. The user can alter settings in the configuration window to read or show alternative parameters, whilst the option of creating a datalog file, when required, is also available in this window. VVM Mode Selecting the Vector Voltmeter tab will enable the VVM mode. This mode is also known as the PAV Phase angle voltmeter and is used to accurately analyse phase angles and voltages between channels 1 and 2. Shown here are the measurement voltages from a LVDT output using a 1KHz input reference signal. When selecting LVDT mode in the parameter box, the scaling factor can be adjusted to suit the displacement required.

LCR Mode Selecting the LCR tab, component and circuit Impedance measurements can be made. Also displayed is the probable circuit arrangement to clarify the measurements obtained. This mode is normally used in conjunction with the LCR active head or the (IAI) Impedance Analyser which can be selected from the ranging window described above. Here using the active head a CR circuit comprising of a 200nf and 1KΩ resistor is measured. RMS Mode Selecting the RMS tab allows both the AC and DC content of the signals to be analysed. Low blanking can also be enabled from this window so that zero is shown if a measurement is below a certain level. Power Mode Selecting the Power tab allows measurements of current and voltage, both as fundamental and true values. To do this, Channel 2 must be configured with an external shunt and told the shunt value so that the current can be calculated. Normally for this mode both channel 1 and 2 inputs are isolated from earth so the measurement is carried out differentially. To start or stop Power integration use the appropriate buttons in this window.

Harm -THD Mode Selecting the Harm THD mode shows the total harmonic distortion information from both channel 1 voltage and channel 2 current. From this page it is possible to set the maximum range of harmonics (up to 64) too be assessed and also select a specific harmonic to be analysed. Sweep Modes Sweep FRA Mode Sweep Data Selecting the Sweep FRA tab will show the CH1-CH2 gain response from an inserted start/stop frequency bandwidth. Both the X and Y scales can be configured to present data in a number of ways and once the graph has been plotted it can be exported to the PC. Note prior to exporting data, open Preferences from the main toolbar, this will allow the type of data to be saved, file path, extension file to be used etc. Then select the export button. Here a Gain v Frequency graph has been plotted for an attenuation circuit, note the cursor information in the bottom LH box showing detailed graph measurements. An example of sweep data exported as a csv file to a basic spreadsheet.

Sweep LCR Mode Using the Sweep LCR tab allows circuit or component impedance measurements to be plotted over a wide frequency band. Normally, this mode is used with the IAI or Active Head fixtures. The graph data can be exported to a PC for further analysis and displayed in a spreadsheet, the same as for the FRA data above. Here a sweep is made over a frequency bandwidth of 15kHz to 80kHz on a Piezo device. It can be seen that it s resonance/anti-resonance point is about 45KHz. The response display can be chosen to be shown in either linear or logarithmic form depending on requirements. By selecting the table sweep button a sweep can be generated from a previously stored table. The second picture shows a zoomed response of the resonance where the sweep is between 35kHz and 50khz.

Simulator, Analyser and Calculator Modes Piezo EQ Calculator This circuit calculator aid is available by selecting Tools from the main toolbar. It enables a resonant circuit to be analysed and provides an equivalent component structure to be calculated. The graph shows the impedance sweep of the piezo resonant circuit over the frequency band of 35KHz to 50KHz. When selecting the Compute EQ Circuit button it shows how the piezo calculator provides the relevant component parameters of the calculated circuit. Circuit Simulator This facility can be utilized by selecting the Circuit simulator button. It can be used for either FRA or LCR circuit simulation and is a useful aid for circuit design frequency response. By choosing the component type and value a simulated impedance or gain plot will be produced. Here the component values of the above calculated circuit are entered, together with the same sweep frequency band. The graph shows the simulated LCR impedance and phase which should be the same as the original plot.

Data Analyser By selecting the Data Analyser button, and in this case using the information obtained from the previous LCR sweep above, the data can be analysed in several ways. These two graphs for instance show the data as a bode plot, top view, with the impedance in white and the phase in red, whilst the bottom view is a nyquist plot of the same data. Cursors are available and can be moved to points in the plot for a more accurate measurement. www.newtons4th.com