ELIMINATION OF EXTRANEOUS NOISE SOURCES FROM ACOUSTIC EMISSION BASED TERMITE DETECTION INSTRUMENT BY USE OF MODAL RATIOS H.L. DUNEGAN AUGUST 15, 2001

Similar documents
THE DECI REPORT. H. L. Dunegan. August, 2000 AN ALTERNATIVE TO PENCIL LEAD BREAKS FOR SIMULATION OF ACOUSTIC EMISSION SIGNAL SOURCES.

Acoustic Emission Basic Process and Definition

EFFECTS OF LATERAL PLATE DIMENSIONS ON ACOUSTIC EMISSION SIGNALS FROM DIPOLE SOURCES. M. A. HAMSTAD*, A. O'GALLAGHER and J. GARY

ACOUSTIC EMISSION MEASUREMENTS ON SHELL STRUCTURES WITH DIRECTLY ATTACHED PIEZO-CERAMIC

EWGAE 2010 Vienna, 8th to 10th September

Electronic Noise Effects on Fundamental Lamb-Mode Acoustic Emission Signal Arrival Times Determined Using Wavelet Transform Results

FA22. Dual 12 inch Coaxial Loudspeaker. product specification. Performance Specifications 1

FX inch Coaxial Vocal Monitor. product specification SERIES. Performance Specifications 1

Minimizing Input Filter Requirements In Military Power Supply Designs

Transfer Function (TRF)

Processor Setting Fundamentals -or- What Is the Crossover Point?

Paper Title: FIELD MONITORING OF FATIGUE CRACK ON HIGHWAY STEEL I- GIRDER BRIDGE

Acoustic Emission Linear Location Cluster Analysis on Seam Welded Hot Reheat Piping

3D Distortion Measurement (DIS)

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.

Abstract: Stringent system specifications impose tough performance requirements on the RF and microwave cables used in aerospace and defense

SECTION NEUTRALIZATION BELOW VHF NEUTRALIZATION

FA28. Dual 8 inch Coaxial Loudspeaker. product specification. Performance Specifications 1

FW inch Coaxial Cardioid Stage Monitor. product specification. Performance Specifications 1

NEURAL NETWORK FATIGUE LIFE PREDICTION IN NOTCHED BRIDGE STEEL I-BEAMS FROM ACOUSTIC EMISSION AMPLITUDE DATA

The Use of a Floating Threshold for Online Acoustic Emission Monitoring of Fossil High Energy Piping

ON LAMB MODES AS A FUNCTION OF ACOUSTIC EMISSION SOURCE RISE TIME #

FATIGUE CRACK CHARACTERIZATION IN CONDUCTING SHEETS BY NON

EE 3302 LAB 1 EQIUPMENT ORIENTATION

Improving the Noise Discrimination for an Ammonia Tank AE Test

USB-UT350(T) Portable Ultrasonic Pulser/Receiver and Analog to Digital Converter. User s Guide

DETECTION AND SIZING OF SHORT FATIGUE CRACKS EMANATING FROM RIVET HOLES O. Kwon 1 and J.C. Kim 1 1 Inha University, Inchon, Korea

An Alternative to Pyrotechnic Testing For Shock Identification

Passive Wireless Sensors

Thermal Johnson Noise Generated by a Resistor

Single Beam Echosounder Test Equipment

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

772D coaxial dual-directional coupler 773D coaxial directional coupler. 775D coaxial dual-directional coupler 776D coaxial dual-directional coupler

PD Solutions. On-Line PD Measurement Devices

Advanced Digital Receiver

Laboratory Experiment #1 Introduction to Spectral Analysis

Figure 4.1 Vector representation of magnetic field.

PORTABLE EDDY CURRENT FLAW DETECTOR

IE-35 & IE-45 RT-60 Manual October, RT 60 Manual. for the IE-35 & IE-45. Copyright 2007 Ivie Technologies Inc. Lehi, UT. Printed in U.S.A.

ELEG 205 Analog Circuits Laboratory Manual Fall 2016

A SIMPLE METHOD TO COMPARE THE SENSITIVITY OF DIFFERENT AE SENSORS FOR TANK FLOOR TESTING

Fluke MDA-510 and MDA-550 Motor Drive Analyzer

First and second order systems. Part 1: First order systems: RC low pass filter and Thermopile. Goals: Department of Physics

AN-671 APPLICATION NOTE One Technology Way P.O. Box 9106 Norwood, MA Tel: 781/ Fax: 781/

MONITORING THE EVOLUTION OF INDIVIDUAL AE SOURCES IN CYCLICALLY LOADED FRP COMPOSITES

SA620 Low voltage LNA, mixer and VCO 1GHz

For the filter shown (suitable for bandpass audio use) with bandwidth B and center frequency f, and gain A:

CX896-MT inch Coaxial Loudspeaker, 70 V. product specification SERIES. Performance Specifications 1

FA12ac. Self-Powered 12 inch Coaxial Loudspeaker. product specification. Performance Specifications 1

Model 7000 Low Noise Differential Preamplifier

E84 Lab 3: Transistor

High Dynamic Range Receiver Parameters

MULTI-CHANNEL CARS BAND DISTRIBUTION USING STANDARD FM MICROWAVE EQUIPMENT. Presented By

SPECS. Impulse (4 and 8 ohm) Two-Way Weather-Resistant Injection-Molded Speaker System SPECIFICATIONS. Built under U.S.

ABSTRACT 1. INTRODUCTION

RX599-MT inch Coaxial Loudspeaker, 70 V. product specification SERIES. Performance Specifications 1

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Physics in Entertainment and the Arts

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

TONE DECODER / PHASE LOCKED LOOP PIN FUNCTION 1 OUTPUT FILTER 2 LOW-PASS FILTER 3 INPUT 4 V + 5 TIMING R 6 TIMING CR 7 GROUND 8 OUTPUT

HEAD. Advanced Filters Module (Code 5019) Overview. Features. Module with various filter tools for sound design

Enhanced Resonant Inspection Using Component Weight Compensation. Richard W. Bono and Gail R. Stultz The Modal Shop, Inc. Cincinnati, OH 45241

Product and Measurement Solutions for the Automotive Industry

MESA-HPX. Assembly and Installation Manual. w/appendix A for Prodelin Antenna. 901-Manual-MESA-HPX

Technical Notes Volume 1, Number 25. Using HLA 4895 modules in arrays: system controller guidelines

SELECTION OF MATERIALS AND SENSORS FOR HEALTH MONITORING OF COMPOSITE STRUCTURES

Quadra 15 Available in Black and White

EXTRACTING INFORMATION FROM CONVENTIONAL AE FEATURES FOR ONSET DAMAGE DETECTION IN CARBON FIBER COMPOSITES

Part Number I s (Amps) n R s (Ω) C j (pf) HSMS x HSMS x HSCH x

ISO INTERNATIONAL STANDARD. Non-destructive testing Ultrasonic inspection Evaluating electronic characteristics of ultrasonic test instruments

Low Frequency Section: 98.0 db SPL, (2.83 V input) High Frequency Section: db SPL, (2.83 V input)

ULTRASOUND DETECTOR D240x OPERATING INSTRUCTIONS. Pettersson. Phone: Fax:

Use of parabolic reflector to amplify in-air signals generated during impact-echo testing

CONSIDERATIONS FOR ACCELEROMETER MOUNTING ON MOTORS

XRT6164A Digital Line Interface Transceiver

Digital Waveform with Jittered Edges. Reference edge. Figure 1. The purpose of this discussion is fourfold.

XR-8038A Precision Waveform Generator

Model Hz to 10MHz Precision Phasemeter. Operating Manual

SPECIFICATIONS QW -1. Listen To This. Mid Frequency Section: 101 db SPL, (2 Volt input) High Frequency Section: 111 db SPL, (2.

When input, output and feedback voltages are all symmetric bipolar signals with respect to ground, no biasing is required.

Capacitive Touch Sensing Tone Generator. Corey Cleveland and Eric Ponce

PORTABLE EDDY CURRENT FLAW DETECTOR VD3-81 EDDYCON

Better system sensitivity through preamplifiers

CX inch Coaxial Loudspeaker. product specification SERIES. Performance Specifications 1

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Impact of the Output Capacitor Selection on Switching DCDC Noise Performance

Filter Considerations for the IBC

GX inch Coaxial Loudspeaker. product specification SERIES. Performance Specifications 1

Advanced Test Equipment Rentals ATEC (2832)

DAMAGE IN CARBON FIBRE COMPOSITES: THE DISCRIMINATION OF ACOUSTIC EMISSION SIGNALS USING FREQUENCY

Dytran Instruments, Inc. 1

Signal Detection with EM1 Receivers

Low voltage LNA, mixer and VCO 1GHz

Looking deeper through Pre Amplifier gain A study

ALM473 DUAL MONO \ STEREO AUDIO LEVEL MASTER OPERATION MANUAL IB

*TD Cinema Mid-High-Very High Loudspeaker System User Manual MHV (254mm) mid, coax high- very high compression driver.

MIL-STD 461F Results for M&A Technology Companion epad Computer

1GHz low voltage LNA, mixer and VCO

Application Report. Art Kay... High-Performance Linear Products

SIA Software Company, Inc.

Transcription:

ELIMINATION OF EXTRANEOUS NOISE SOURCES FROM ACOUSTIC EMISSION BASED TERMITE DETECTION INSTRUMENT BY USE OF MODAL RATIOS H.L. DUNEGAN AUGUST 15, 2001 INTRODUCTION The major problem faced with the use of acoustic or acoustic emission instruments for the detection of termites or other wood feeding insects in wood is their susceptibility to being triggered by extraneous air borne signals as well as friction between members or casual contact of the board being inspected. The primary reason extraneous noise is a problem results from the basic design of the instruments. It is desirable to detect the termite activity in wood products which are inherently attenuating in nature compared to other types of buildng materials such as metals and glass. Therefore it is necessary to operate in the frequency range from 30KHz to 150KHz with high amplification of the sensor signal in order to detect termite activity at a reasonable distance from the sensor in wood products. This low frequency operation and high sensitivity needed to detect termites results in an instrument that is also very good at detecting signals that are airborne and signals due to impact and friction on the member being tested. This problem is very similar to the problem faced when designing acoustic emission instrumentation for detecting crack growth in structures constructed from metal plates, such as aircraft and bridges. The solution we found for solving the problem of extraneous noise in these types of structures led to the issuance of several patents. The basis for these patents is the use of modal ratios of different plate modes traveling in the plate. It was discovered that out-of-plane (OOP) sources of acoustic noise such as airborne, impact, and friction, resulted in a large low frequency flexure wave, a shear wave, and a small component of an extensional wave. A growing crack is an in-plane (IP) source and produces a high frequency extensional and shear wave and a low amplitude flexure wave whose amplitude depends on the depth in the plate where crack extension occurs. We discovered that breaking the detected signal into a high frequency (HF) component, and a low frequency (LF) component, and taking the ratio of the HF/LF amplitudes would allow us to identify the type of source (OOP or IP) that produced the signal. An instrument was designed to detect the peak amplitude of the HF and LF components and calculate their ratio. A filter was designed such that a set ratio value could be selected and only signals produceing ratios above the set value would be accepted as a crack growth created signal. The reader is advised to read the above patents for a detailed explanation of the modal ratio procedure. TERMITE ACTIVITY There exists a close parallel of detecting crack growth in metal plates and detecting termites in a wood plank. Both the crack growth and the termite activity are (IP) sources for generating stress waves which can be detected with acoustic emission sensors and instruments. There is also a close parallel in 1

both cases that extraneous noise sources are (OOP) sources. Therefore an experimental study was made of termite activity using our instrument the AESMART 2000 developed under the previous named patents to determine if modal ratios could be used to eliminate extraneous noise for the portable TRACKER instrument. The results proved very successful and the modal ratio circuit with the appropriate filters will be incorporated into the portable TERMITE TRACKER instrument as well as a multiple channel instrument the AESMART TERMITE DETECTOR. Experimental results of this study will now be presented. EXPERIMENTAL PROCEDURE Figure 1 A wood board 2X4 inch in dimensions and 2 meters long containing termites was used in the study. Figure 1 shows the board with the TERMITE TRACKER transducer attached to a waveguide that has been inserted into a drill hole in the board. Figure 2 shows the experimental setup used for detecting and recording the signals from the termites in the board. The instruments used were the AESMART 2000, a Tektronix digital oscilloscope with FFT capability, and a Krohn-hite band pass filter with 4 pole skirts. Figure 2 The SE40-Q 40 KHz transducer seen attached to the waveguide in figure 1 was fitted with a 20dB internal preamplifier which was powered by the AESMART2000 instrument. The broadband signal 20KHz-500KHz from the AESMART 2000 was first inserted into the digital oscilloscope in figure 2 in order to measure the broadband frequency response of termite activity and extraneous noise sources. It was discovered that most of the termit activity and airborne and rubbing noise was contained in the frequency range from 20KHz to 50KHz. This was not surprising since the peak response of the SE40-Q transducer is in the 40KHz range of frequency. We discovered that the frequency spectra of the termite activity and the extraneous noise sources did differ significantly which led us to further experiment with the use of frequency ratios in order to develop a modal ratio filter. This was accomplished by bypassing the filter stages in the AESMART 2000 instrument, and using the variable bandpass filter capability of the Krohn-hite instrument instead. Figure 3 shows the frequency response of the termite activity averaged over 126 samples. Note that there appears to be two distinct frequencies bands from the termite activity containing most of the 2

Figure 3 Figure 4 energy of the signals at approximately 25KHz and 35KHz frequencies. The lack of any signals below 20 KHz is due to the presence of a 20KHz hi-pass filter. Since the resonant frequency of the SE40-Q transducer is 40KHz we were surprised to see a lack of signal at this frequency. This is probably due to the modification of the frequency response caused by the waveguide attached to the transducer. Figure 4 shows the frequency content averaged over 126 signals produced by gently rubbing the board with the index finger near the transducer location. This rubbing could also be detected at 1 meter away from the transducer. Note that the low frequency content of the signals matches that of the termite activity but there is a lack of signals at the higher frequency compared to the termite activity. Note also that the average amplitude of the low frequency signals are 10dB higher than that from the termite activity. Figure 5 shows the frequency spectra produced by jingling of car keys 1 meter away from the transducer. Note a shift to lower frequencies in comparison to the termites and rubbing, and a lack of higher frequency content. Again the amplitude of the low frequency signals appear to be approximately 10dB higher than the amplitude produced by the termites. Jingling of the car keys at 30 feet distance from the transducer could still be easily detected by the system. Figure 5 FILTERING TECHNIQUES The high frequency and low frequency filters normally used in the AESMART 2000 were bypassed and the Krohn-hite variable filter instrument was used for filter selection. The optimum filter ranges for separating the termite activity from the extraneous noise sources was a low frequency (LF) bandpass between 20 and 25KHz, and a high frequency (HF) bandpass between 25 and 50KHz. Signals from the termites and noise in these two frequency ranges were peak detected and passed on to the A/D converter in a computer running with DECI-24 labview based software. The peak amplitudes of signals with these two frequency 3

components were digitized and the ratio of the was calculated. When a valid signal was detected: the time of the event, the sum of the events, the peak amplitude of the HF and LF signal, and the HF/LF ratio were recorded and downloaded to a microsoft Excel spread sheet. Figure 6 shows the type of information recorded in the Excel spreadsheet. Run time minutes events HF amp LF amp ratio ratio Filter filter =2set 23.85 0.3975 130 298 83 3.59 FILTER Filter on ON 23.9 0.398333 131 Figure 6840 322 2.61 TERMITES Termites 24.01 0.400167 132 1519 576 2.64 24.12 0.402 133 415 117 3.54 24.17 0.402833 134 728 156 4.66 24.34 0.405667 135 391 181 2.16 24.45 0.4075 136 322 88 3.67 24.61 0.410167 137 439 166 2.65 24.67 0.411167 138 1133 425 2.67 24.83 0.413833 139 298 127 2.35 24.89 0.414833 140 288 98 2.95 25.05 0.4175 141 425 137 3.11 25.16 0.419333 142 532 225 2.37 25.43 0.423833 143 322 142 2.28 25.49 0.424833 144 791 322 2.45 25.54 0.425667 145 640 635 1.01 FILTER Filter Off OFF 25.6 0.426667 146 5615 5327 1.05 RUBBING Keys BOARD Jingling 25.65 0.4275 147 6367 6055 1.05 25.65 0.4275 148 5625 4902 1.15 25.71 0.4285 149 6221 6030 1.03 25.76 0.429333 150 3276 3940 0.83 25.76 0.429333 151 1948 2427 0.8 25.82 0.430333 152 454 322 1.41 HF/LF RATIO 8 7 6 5 4 3 2 1 NOISE STUDIES FROM TERMITE ACTIVITY-HF/LF RATIO VS EVENTS HF/LF RATIO FILTER SETTING = 2 26-Jul-01 Figure 7 KEYS JINGLING-RATIO FILTER OFF 0 0 100 200 300 400 500 600 EVENTS RUBBING- RATIO FILTER OFF A portion of this data was recorded with a ratio filter setting of 2 and the filter was turned on. Therefore only signals producing HF/LF ratios of greater than 2 were accepted by the system. The filter was then turned off and noise due to jingling of keys was introduced. Note that the ratios calculated due to this noise source are all below the value of 2. Note also that the amplitude of the signals due to this noise source were much higher in amplitude. Jingling of keys and Rubbing of the surface both produced ratios of less than 2 and were not recorded with the ratio filter set at 2 and turned on.. Figure 7 shows a graphical presentation of the calculated ratios as a function of events recorded during the test. Note that the ratio of the events recorded from the jingling keys and rubbing of the board while the filter was turned off, both group at values below 2. Both jingling of keys and rubbing of the surface produce a fairly constant noise source and therefore not much data from the termite activity is recorded during this period. Most noise sources encountered in the field only 4

occur on a periodic basis. Therefore the loss of termite activity data during such a period is minimal. Figure 8 shows a plot of the peak amplitude of the HF signals per event This data shows that over an order of magnitude range of amplitudes are present due to Termite activity. HF VOLTAGE (mv) 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 difference. CUMULATIVE EVENTS 2.6 INCH WAVEGUIDE RATIO FILTER SET = 2 HF VOLTAGE vs EVENTS Figure 8 KEYS JINGLING FILTER OFF 0 0 100 200 300 400 500 600 700 600 500 400 300 200 100 EVENTS RUBBING FILTER OFF NOISE STUDIES-EVENTS VS TIME FROM TERMITE ACTIVITY 2.6 INCH WAVEGUIDE, HF/LF FILTER= 2 LF=20-25 Khz BANDPASS HF=25-500 Khz BANDPASS 26-Jul-01 RUBBING BOARD NEAR SENSOR KEYS JINGLING RATIO FILTER ON RATIO FILTER OFF Figure 9 0 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 TIME (min) RATIO FILTER ON RATIO FILTER OFF 331 EVENTS/MINUTE The HF threshold for recording the data in figure 8 was set at 300 millivolts. We postulate that the signals above 1000 millivolts are probably due to feeding activity, and the numerous lower level signals due to movement and other activity within the gallery. Note that the signals recorded due to the keys jingling are higher amplitude than those due to termite activity as was shown earlier in this report. The noise signals due to rubbing do not show the same high amplitude Figure 9 shows a graphic of the cumulative events as a function of time of the test. The average events per minute with the filter on, such that only termite activity is being recorded is 331 events/mnute. Note the increase in slope of the data for conditions where the filter is turned off and the noise sources due to jingling of keys and rubbing of the board produce signals that significantly change the event rate. Termite activity can vary greatly over a period of 24 hours, but as can be seen by figure 9 the activity is fairly constant over a period of a few minutes. MULTIPLE CHANNEL OPERATION An acoustic emission instrument that has the capability of filtering out extraneous noise sources such as impact, friction, and airborne signals will fulfill two primary needs: One, locating termite or other wood feeding insects where there is no visual evidence of their presence, and two, monitoring of treatment processes to eradicate such insects to assure that the treatment process has been effective. 5

For many situations involving local treatment, a portable battery powered unit can be effective in solving both of the above needs. In other situations involving tenting of large structures, which prohibit the presence of human occupancy. the ability to monitor many locations within the structure while the treatment is in process is desired. For this situation the multiplexing of many channels placed at stratigic locations throughout the structure would be an effective method to determine how long the treatment should take to eradicate the insects. A simplified block diagram of such a system to accomplish the effective monitoring of many loacations is shown in figure 10. As many as 100 transducers in direct contact or mounted on Figure 10 waveguides as shown in figure 1, could be placed in termite infested locations throughout a large structure. They could all be connected by a single cable, with each transducer having an address that could be selected by the computer for monitoring and recording of data from each specific location. The cable is then taken to a van or other vechile which contains the hardware and computer for analyzing the data. A dwell time is selected by the operator and the system sequentially muxes and records data from each channel based on the selected dwell time. The AE signal from the termite activity is split into two frequency components, the peak amplitude of each channel is measured and the ratio calculated by the computer. A ratio filter is constructed for the elimination of extraneous noise as shown by data in this report. The filtered data is downloaded to an excel spread sheet (figure 6) to allow analysis and plotting of each channels data. 6

The treatment process is started and all channels are monitored. When all channels cease to record any activity from the locations being monitored, the treatment can be considered effective in eradication of the wood feeding insects. If activity is recorded from any channel, the treatment process should continued until all activity ceases. Only then can it be determined that the treatment was successful. In order for this monitoring method to be successful, the ability to measure movement of the insects within the gallery is necessary. Simply monitoring the higher amplitude signals due to feeding would not be adequate since the insects could simply quit eating but still be alive. Dunegan Engineering Consultants Inc., PO Box 61808, Midland, TX 79711 Tele: (432) 561-5901, Fax: (432) 563-0178, Email: hal@deci.com, Web: www.deci.com 7