Keysight U1461A Insulation Multimeter/ U1453A Insulation Tester

Similar documents
Keysight U1231A/ U1232A/U1233A Handheld Multimeter. Quick Start Guide

Agilent U1231A/U1232A/U1233A Handheld Multimeter. Quick Start Guide

Agilent U1273A/U1273AX Handheld Digital Multimeter. Quick Start Guide

Agilent U1271A/U1272A Handheld Digital Multimeter. Quick Start Guide

Keysight U1241C/ U1242C Handheld Digital Multimeter. Quick Start Guide

Agilent U1253B True RMS OLED Multimeter. Quick Start Guide

Agilent U1251B and U1252B Handheld Digital Multimeter. Quick Start Guide

Agilent U1450A/U1460A Insulation Resistance Testers

Agilent U1211A, U1212A, and U1213A Clamp Meter. Quick Start Guide U1211A U1212A U1213A

Keysight Technologies U1450A/U1460A Insulation Resistance Testers

Agilent U1251A and U1252A Handheld Digital Multimeter

1507/1503. Insulation Testers. Users Manual

Agilent U1231A, U1232A, and U1233A Handheld Digital Multimeter

Keysight U1273A/U1273AX Handheld Digital Multimeter

Keysight U1231A, U1232A, and U1233A Handheld Digital Multimeter

Keysight U1273A/U1273AX Handheld Digital Multimeter

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

DM-45 Digital Multimeter

Agilent U1190A Series Handheld Clamp Meters

Agilent U1273A/U1273AX Handheld Digital Multimeter

DVM1190 DIGITAL MULTIMETER

MS2030 CAT III 600 V A V AUTO RS232

Keysight U1253B True RMS OLED Multimeter

USER'S MANUAL DMR-6700

Keysight U1211A, U1212A, and U1213A Clamp Meters

Dawson DDM190. Digital Multimeter User s Manual

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

4-range High voltage insulation resistance tester KEW 3126

Agilent U1251A and U1252A Handheld Digital Multimeter

Model 77 Series IV. Digital Multimeter. Users Manual

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

USER'S MANUAL BM878, BM877 & BM876 Insulation Tester Combination Multimeter

Keysight U1253B True RMS OLED Multimeter

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

Keysight U1241B and U1242B Handheld Digital Multimeters

79/26 Series III Multimeter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

1507/1503. Insulation Testers. Technical Data. Features and benefits:

Agilent U1271A/U1272A Handheld Digital Multimeter

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

MIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

AC/DC CLAMP METER USER S MANUAL

Agilent U1253B True RMS OLED Multimeter

15B+/17B+/18B+ Calibration Manual. Digital Multimeter

1.General instructions Specifications Description...7

MIT400/2 CAT IV Insulation testers

Agilent U1251B and U1252B Handheld Digital Multimeter

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

NOTE: Fully read and understand this manual before using this Digital Multimeter.

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

MIT400 CAT IV Industrial Insulation Testers

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

MIT400 CAT IV Industrial Insulation Testers

Analog Technologies. Multimeter 115C and 117C

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

AMM-1022 Digital Multimeter USER`S MANUAL

Keysight U1401B Handheld Multi-Function Calibrator/Meter

OPERATOR S INSTRUCTION MANUAL

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

1587/1577 Insulation Multimeters

DIGITAL HiTESTER. Instruction Manual

U1401A Handheld Multi-Function Calibrator/Meter

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

USER'S MANUAL DMR-4350

323/324/325 Clamp Meter

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

# Digital Multimeter

Keysight Technologies U1280 Series Handheld Digital Multimeters

MIT415 Insulation tester

INSULATION TESTER SERIES

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

Agilent U1241A and U1242A Handheld Digital Multimeters

1507/1503. Insulation Testers. Users Manual

Digital Multimeter User Manual

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

Accuracy 1.2 PERCENT AC VOLTAGE, 0.5 PERCENT DC VOLTAGE, 1.5 PERCENT DC CURRENT, 1 PERCENT RESISTANCE, 2.5 PERCENT TEMPERATURE Battery Type

Autoranging Multimeter Extech EX503

770E DIGITAL MULTIMETER OPERATOR S MANUAL

QUICK SETUP GUIDE SECULIFE HITAM

USER'S MANUAL DMR-4300

OPERATING INSTRUCTION

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

Compact MultiMeters + Voltage Detector

Portable Appliance Testers. OmegaPAT MI 2140 BetaPAT MI 2141 User Manual Ver Code No

902 FC. HVAC True-rms Clamp Meter

IDM 503 & 505 Digital Multimeters

374 FC/375 FC/376 FC Clamp Meter

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

DDM350 Pen-Type Digital Multimeter User s Manual

DIGIT & POINTER MULTIMETER

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Transcription:

Keysight U46A Insulation Multimeter/ U453A Insulation Tester Quick Start Guide

Standard Accessories Included In Your Purchase Standard Accessories Included In Your Purchase The following accessories are shipped standard with the U46A and U453A testers: Hard carrying case Alligator clips (red and black) Test leads (red and black) 9 mm probes (red and black) 4 mm probes (red and black) Remote switch probe and adapter Four.5 V AA lithium batteries IR to USB cable U7A IR to Bluetooth adapter Printed copy of the U7A Operating Instructions Printed copy of the U46A/U453A Quick Start Guide (this document) Model U46A also includes the following accessories: Thermocouple adapter (J/K-Type) Thermocouple bead (J-Type) Thermocouple bead (K-Type) If any item is missing or damaged, keep the shipping materials and contact the nearest Keysight Sales Office. NOTE The descriptions and instructions in this guide apply to the U46A Insulation Multimeter and U453A Insulation Tester. Model U46A appears in all illustrations. The word tester is used to represent both models. All related documents and software are available for download at www.keysight.com/find/hhtechlib. U46A/U453A Quick Start Guide

Install or Change the Batteries Install or Change the Batteries The tester is powered by four.5 V AA lithium batteries (included in the shipment). Before installing or changing the batteries, pull from a corner and stretch the orange rubber holster to remove it. 3 4 Turn On the Tester Turn the rotary switch from the position to any other position to begin making measurements. U46A/U453A Quick Start Guide

The Tester at a Glance The Tester at a Glance Vsense/Red LED indicator (Vsense for model U46A) Display screen Keypad Rotary switch Input terminals IR communication port Test lead/probe holders Battery access (Under the orange rubber holster) Tilt stand Fuse access (Under the orange rubber holster) U46A/U453A Quick Start Guide 3

Using the Rotary Switch Using the Rotary Switch NOTE Press [T DAR PI] to select the alternate measurement function(s) or test methods for insulation resistance tests. Legend Measurement function U46A U453A 50 V insulation resistance, T, DAR, PI 00 V insulation resistance, T, DAR, PI 50 V insulation resistance, T, DAR, PI 500 V insulation resistance, T, DAR, PI 000 V insulation resistance, T, DAR, PI Earth-bond resistance, T Resistance, Continuity, Diode, Capacitance AC V, AC V with LPF - AC V - Auto (V), DC V, AC V Auto (mv), DC mv, AC mv, Temperature - Auto (μa ma), DC μa ma, AC μa ma - WARNING Remove the test leads from the measuring source or target before changing the rotary switch position. Refer to the U46A/U453A User s Guide for a complete list and description of all rotary switch labels. 4 U46A/U453A Quick Start Guide

Using the Keypad Using the Keypad Legend Key response when pressed for: Less than second More than second IR Test: Initiates an insulation test [] as long as [Test] is held ( is shown) the tester sources (outputs) a high voltage and measures insulation resistance EBR Test: Initiates an earth-bond resistance test [] as long as [Test] is held ( is shown) Trig Hold: Freezes the present reading in the display [3] Lock: Locks the insulation test or earth-bond resistance test [4] Hz: Displays the frequency (when the rotary switch is in the V, mv (U46A), or μa ma (U46A) position) Esc: Discards the changes made in the Setup menu Selects the alternate measurement function(s) T: Configures the tester for a timed test [4][5] DAR: Configures the tester for a dielectric absorption ratio test [][5] PI: Configures the tester for a polarization index test [][5] Limit: Enables Limit comparison Trip: Configures the tester for Leakage Current, Scan, or Ramp Trip tests [4][5] Range: Sets a manual range Leak: Displays the leakage current [4] Auto Hold: Automatically freezes the present reading once the reading is stable [3] View: Enters the Log review menu Log: Starts the data Log Max Min: Enables Max Min recording [6] Auto: Enables autoranging U46A/U453A Quick Start Guide 5

Using the Input Terminals Legend Key response when pressed for: Less than second More than second Null: Enables Null : Increases or decreases the OLED brightness this option must first be enabled in the Setup Vsense (U46A): Enables the non-contact voltage detector Setup: Enters the Setup menu [] When the rotary switch is in one of the Ω Mega position. [] When the rotary switch is in the Ω EB position. [3] When the rotary switch is NOT in one of the Ω Mega or the Ω EB position. [4] When the rotary switch is in one of the Ω Mega or the Ω EB position. [5] Press [Test] to start the test. [6] Max Min is disabled when Trip is enabled. Using the Input Terminals WARNING To avoid damaging this device, do not exceed the input limit. Rotary position Input terminals Overload protection 000 Vrms 000 Vrms for short circuit <0.3 A 440 ma/000 V, 30 ka fast-acting fuse 6 U46A/U453A Quick Start Guide

Insulation Resistance (IR) Test Insulation Resistance (IR) Test Ensure that the device-under-test (DUT) is de-energized before performing any resistance measurement. The tester automatically detects if the circuit is energized. If the external voltage is detected to be greater than 30 V, the test is inhibited and the voltage hazard symbol ( ) is shown on the display. CAUTION DO NOT perform insulation resistance test in distribution systems with voltages higher than 600 V. Select a test voltage 3 Remote Switch Probe U46A/U453A Quick Start Guide 7

Insulation Resistance (IR) Test 4 Hold Test will continue until [Test] is released. NOTE When an insulation test is in progress, the red LED indicator at the top of the tester will blink every seconds (if the Limit function is not enabled). Using the Remote Switch Probe = Locking the Test for IR/EBR Tests Press once Press [Test] or [Lock] again to unlock and stop the test. 8 U46A/U453A Quick Start Guide

Insulation Resistance (IR) Test Performing PI/DAR/T for IR Tests Polarization Index (PI) = IR 0 minutes/ir minute Dielectric Absorption Ratio (DAR) = IR 60 seconds /IR 30 seconds (default; can be changed to IR 60 seconds /IR 5 seconds in Setup) Timed (T) for IR and EBR = IR minute (default; can be changed in Setup) NOTE Error is shown on the display if the IR is greater than the maximum range or less than 0.00 MΩ after t/t5/t30; if the test is interrupted by the user; or if the tester s battery is low. Viewing Leakage Current U46A/U453A Quick Start Guide 9

Insulation Resistance (IR) Test Performing Leakage Current/Scan/Ramp Trip Tests Use the Leakage Current Trip Test, Scan Trip Test, and Ramp Trip Test to test MOVs (Metal Oxide Varistors), gas discharge tubes, voltage arresters, or sparking gaps. The voltage source will be stopped when the current is greater than the trip current you set in the Setup. 3 4 NOTE For more information on the Leakage Current Trip Test, Scan Trip Test, and Ramp Trip Test, refer to the respective sections in the U46A/U453A User s Guide. 0 U46A/U453A Quick Start Guide

Earth-Bond Resistance (EBR) Test Earth-Bond Resistance (EBR) Test CAUTION The tester automatically detects if the circuit is energized. If the external voltage is detected to be greater than V, the test is inhibited and is shown on the display. Disconnect the tester and remove power before proceeding. 3 Remote Switch Probe 4 Hold OR > U46A/U453A Quick Start Guide

Voltage Measurement Voltage Measurement The Auto function is able to automatically identify the signal component (AC or DC) of an electrical source to be indicated on the primary display, and select a suitable measurement range according to the AC+DC reading The symbol blinks during the identification DC AC The AC+DC value is shown in the secondary display 3 DC AC U46A/U453A Quick Start Guide

Voltage Measurement Measuring AC Voltage with a Low-Pass Filter (LPF) AC 3 WARNING To avoid possible electric shock or personal injury, ensure that you are aware of the voltage level without the LPF enabled. There may be a possible presence of hazardous voltage, and voltages measured with the LPF enabled may be greater than indicated. For your safety, take note of the symbol. Disable the LPF when you have finished your measurement. When the LPF option is selected, the measurement function will switch to the manual range mode (defaults to 600 V) for variable speed drive (VSD) applications. It is recommended only to use 600 V and 000 V in the manual range for VSD testing. U46A/U453A Quick Start Guide 3

Voltage Measurement Enable the LPF in the Setup to filter out higher frequencies with (AC/DC path) V, mv, μa, or ma measurements. > sec. > > > sec. > > > 4 U46A/U453A Quick Start Guide

Current Measurement Current Measurement WARNING Never attempt an in-circuit current measurement where the open-circuit potential to earth is greater than 000 V. CAUTION Current can be measured up to 440 ma (maximum) continuously. You can measure current more than 440 ma and up to 600 ma for 0 seconds maximum. Cool down the tester for twice the measuring time taken before proceeding to another current measurement. Refer to Voltage Measurement for more information on how the Auto function works. 3 AC LOAD LOAD DC U46A/U453A Quick Start Guide 5

Current Measurement Measuring Voltage Frequency Measuring Current Frequency Measuring Frequency/Pulse Width/Duty Cycle For model U46A only. This option must first be enabled in the Setup. Press and hold [ ] to enter the Setup. Browse to Menu 0 > % & ms and change the option from +CYCLE-D to +CYCLE-E or CYCLE-E. 6 U46A/U453A Quick Start Guide

Resistance Measurement Resistance Measurement 3 Removing Test Lead Resistance U46A/U453A Quick Start Guide 7

Continuity Test Continuity Test CAUTION To avoid possible damage to your tester or to the equipment under test, disconnect the circuit power and discharge all high-voltage capacitors before performing continuity tests. 3 OFF (open) ON (closed) 4 8 U46A/U453A Quick Start Guide

Diode Test Diode Test 3 4 NOTE Press and hold [Range] to enable Auto-diode. The Auto-diode feature will help you test both forward- and reverse-bias directions simultaneously. You do not need to change the measuring direction to identify the diode s condition. U46A/U453A Quick Start Guide 9

Capacitance Measurement Capacitance Measurement Before proceeding with capacitance measurements, first use the DC V function to confirm that the capacitor is fully discharged. 3 + 4 NOTE Hz Press [Lock Esc] to temporarily display the cable length of the circuit under test in the secondary display. 0 U46A/U453A Quick Start Guide

Temperature Measurement Temperature Measurement WARNING Do not connect the thermocouple to electrically live circuits. Doing so will potentially cause fire or electrical shock. 3 4 NOTE Press and hold [Range] to remove the ambient compensation for temperature measurements. U46A/U453A Quick Start Guide

Non-Contact Voltage Detector (Vsense) Non-Contact Voltage Detector (Vsense) WARNING Voltage could still be present even if there is no alert indication. Do not rely on the Vsense detector with shielded wires. Never touch live voltage or conductors without the necessary insulation protection. The Vsense detector may be affected by differences in socket design, insulation thickness, and insulation type. AC Voltage Source AC 3 > sec. NOTE Press [Range] to change the Vsense detector s sensitivity from HIGH SENSE to LOW SENSE. U46A/U453A Quick Start Guide

Non-Contact Voltage Detector (Vsense) THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK. U46A/U453A Quick Start Guide 3

Contacting Keysight You can contact Keysight Technologies at one of the following telephone numbers for warranty, service, or technical support information: In the United States: + 800 89-4444 In Canada: + 877 894-444 In China: 800-80-089 In Europe: 3 0 547 In Japan: 00-4-345 Or use our Web link for information on contacting Keysight worldwide: www.keysight.com/find/assist Or contact your Keysight Technologies Representative. Safety Notices CAUTION A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAU- TION notice until the indicated conditions are fully understood and met. Safety and EMC Information This meter is safety-certified in compliance with IEC/EN 600-:00 for Category III 000 V and Category IV 600 V; and IEC/EN 6557-, IEC/EN 6557-, IEC/EN 6557-4. EMC designed in compliance with IEC 636-:005/EN 636-:006. Use with standard or compatible test probes. Safety Symbols Earth (ground) terminal WARNING A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met. CAT III 000 V CAT IV 600 V Equipment protected throughout by double insulation or reinforced insulation Caution, risk of electric shock Caution, risk of danger (refer to the instrument manual for specific Warning or Caution information) Category III 000 V overvoltage protection Category IV 600 V overvoltage protection Do not use in distribution systems with voltages higher than 600 V For more details on any information not found in this document, refer to the Keysight U46A Insulation Multimeter/U453A Insulation Tester User s Guide.

This information is subject to change without notice. Keysight Technologies 03-04 Edition 3, August 04 *U46-9000* U46-9000 www.keysight.com