RAIL PANEL AT TRANSITION SECTION PLAN - POST DETAIL PLAN - TUBE SPLICE. Colorado Department of Transportation. Staff Bridge Branch

Similar documents
24" B B Joint X501 Joint See MARKINGS Note PCB-RXX-350-TL3 " X501 Y301 (Typ.) " A PLAN (reinforced casting option shown) A " dia. Hinge Bar (Typ.) NOT

ALUMINUM PIPE GUIDERAIL 01/01/

STEEL PIPE GUIDERAIL 01/01/

BRIDGE RAILING, 4 TUBE B-26-F POST DETAILS MICHIGAN DEPARTMENT OF TRANSPORTATION

Midwest Roadside Safety Facility

Midwest Roadside Safety Facility

Midwest Roadside Safety Facility

(50 FT FT) MICHIGAN DEPARTMENT OF TRANSPORTATION 10-0" 7-6" 8-0" 6-0" Truss Depth. 3" sheets 5 & 6 of 10) DEPARTMENT DIRECTOR. Kirk T.

TYPE J (20 FT - 40 FT) MICHIGAN DEPARTMENT OF TRANSPORTATION 10-0" 7-6" NOTE: sheet 5 & 6 of 10) DEPARTMENT DIRECTOR. Kirk T.

Midwest Roadside Safety Facility

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

B-27-A BRIDGE RAILING, 3 TUBE WITH PICKETS SECTION THROUGH RAILING WITH BRUSH BLOCK SECTION THROUGH RAILING WITH SIDEWALK

1.1 RELATED DOCUMENTS

Midwest Roadside Safety Facility

BID TABULATION SHEET

GENERAL ELEVATION SECTION A-A

AUXILIARY FRAMING AND ACCESSORIES

2. Remove from the Standard Plate manual: Standard Plate Index, Sheets 1-4 of 4, Numerical Index of Standard Plates (August 31, 2012)

SECTION METAL FABRICATIONS

E:\Wilmot\DGN\14018pp.dgn 3/11/2015 6:49:16 AM

Standard Plate Sheer Reinforcement for Precast Drainage Structures has been updated upon recommendation of the Bridge Office.

Midwest Roadside Safety Facility

KOLO SHELTER Installation Instructions Parts List

Midwest Roadside Safety Facility

Current Standard Plates including Transmittal Letters are available on the web at:

B " 787

D. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC

GENERAL ISOMETRIC LAYOUT

New Product Release: October 2014 Boone Racks

Deck Design Guide. One and Two Family Residential Dwellings

ROUND STEEL POLE STRAIGHT

CONTENTS TOOL LIST U P S I D E I N N O V A T I O N S, L L C RAMP AND STEP SYSTEM ASSEMBLY INSTRUCTIONS. Revised: June 2013

OHIO DEPARTMENT OF TRANSPORTATION CENTRAL OFFICE, 1980 W. BROAD ST., COLUMBUS, OHIO

PART MATERIALS. Section Fencing Materials. Description

3616 Old Howard Co. Airport Road Big Spring, TX

Digitally Signed 06/02/2015

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

Section COUPLINGS AND COUPLING ADAPTERS. This Section covers couplings and coupling adapters for ductile iron and steel pipe.

Factory Assistance: Phone: Fax: Page 1

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

DESIGN GUIDELINES (SD) COUNTY OF ALAMEDA PUBLIC WORKS AGENCY 399 ELMHURST STREET HAYWARD, CA

BEST PRACTICE GUIDE. Socket Bases. Working with Concrete Slabs

Manhole or Catch Basin Type A & B Cone Sections Precast - Design F Manhole or Catch Basin Cover (Reducer Cone Section Precast) Design D

1.1 SUMMARY. A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards.

KO LO SH E LT E R. High Capacity and Flexibility

SIG-032-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY III LUMINAIRE ARM (SEE CONTRACT) 6'-0", 8'-0", 10'-0" NOMINAL SPREAD

STRUCTURAL STEEL AND ALUMINUM PART 1 - GENERAL 1.01 SCOPE:

ALL SEASON PATIO COVER

SIG-030-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY I LUMINAIRE ARM 6'-0", 8'-0", 10'-0" NOMINAL SPREAD (SEE CONTRACT) POLE CAP

SQUARE STEEL POLE STRAIGHT

CONCRETE ACCESSORIES BAR-LOCK REBAR COUPLER SYSTEM

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Current Standard Plates including Transmittal Letters are available on the web at:

B Connectors. Automation. Structural Framing System Connectors & Fasteners

STRATUS SHELTER. Take bike parking to new heights

Installation Instructions

1.8 METER SERIES 1194 ANTENNA SYSTEM

CAT-350 Product Manual

STRUCTURAL ATTACHMENTS

Pipe Product Catalog Table of Contents

1.8 METER SERIES 1184 ANTENNA SYSTEM

Fixings & Fastenings. Bright Zinc Plated, Galvanised & Stainless Steel. Lockinex. ea i, ea u i

HEADED ANCHOR BOLT OPTION

Shearwall System Installation Guide

TREX PERGOLA INSTALLATION INSTRUCTIONS

SIGNALS AND LIGHTING FIELD GUIDE

Swerve Rack CUSTOM RACKS AVAILABLE

Dura-Lock Roof System

Independent Containment System (ICS)

BASEBALL FOUL POLES GROUND SLEEVE MOUNTED

UFGS (November 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

24" max from each end of the ledger. See detail 6A & 6B, typ. both ends IRC R Ledger R507.2

SKT-SP Tangent Terminal

FIRE STATION NO TH STREET NORTH ST. PETERSBURG, FL M-1 SCOPE OF WORK SYMBOL DESCRIPTION SYMBOL DESCRIPTION HVAC SYMBOL LEGEND

Track Rack. * Track Racks are not lockable

Cable Railing Kit Application Guide

SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS

Steel Casework Metal Framing System

TYPICAL STANDOFF GLASS RAIL ELEVATION TYPICAL SECTION RS0B20 WITH RECTANGULAR BACK PLATE TYPICAL STAIRS

SECTION ROUGH CARPENTRY

A. Rough carpentry includes but is not limited to the following:

Installation of Balustrade Systems

SECTION STRUCTURAL STEEL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

INSTALLATION INTRUCTIONS

Downtown Rack. Custom logo option available

712 - STRUCTURAL STEEL CONSTRUCTION SECTION 712 STRUCTURAL STEEL CONSTRUCTION

March 1, Fax:

Collins Engineers Palmetto Islands County Park Boardwalk Repairs 03/28/2014 SECTION ROUGH CARPENTRY

Straight Stringer Installation Instructions

Assembly Instructions for. for 31" MGS (Midwest Guardrail System) ROAD SYSTEMS, INC.

SECTION MASONRY ANCHORAGE AND REINFORCEMENT. Display hidden notes to specifier. (Don't know how? Click Here)

Door Canopy. PDL Building Products Industrial Parkway, N. Olmsted, OH Phone:

Intex Engineered Pergola System Installation Instructions. NOTE: See Appendix for Foundation Requirements

SECTION SHEET METAL FLASHING AND TRIM

SUBJECT: Standard Plates 4132, 4155, Drainage Structures and Castings Info

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

ULT R A S PACE SAV E R SQ UA R E D

Installation Instructions

Open Up Your View With CABLE SYSTEMS

TECHNICAL CORRECTION October Process Industry Practices Structural. PIP STF05121 Fabrication and Installation of Anchor Bolts

Transcription:

Limits of pay length for Bridge RailType 10M (For post spacing, see Dwg. No. B ) B60610 (Use with B60610A) 8 min. 1 max. 8 min. 1 max. 10 0 Max. 10 0 Max. post spacing 10 0 Max. 2 5 Post 1 x 1 slotted 1 x 4 slotted holes at splices 1 x 1 slotted holes at bridge holes in post exp n device POST Type 3G or 3H transition (See M6061) The height of the transition will vary to match bridge rail and roadway guardrail: 1 when bridge deck has a overlay, when bridge deck has a silica fume overlay and 4 when bridge deck does not have an overlay. All tubes shall be ASTM A500 Grade B. DATE DATE DATE ed By 3/99 11/99 5/00 5/01 4/02 6/04 3/07 10/13 2 11 Open joint in curb to match location and width of any joint in the supported slab. See slab joint details for treatment of any expansion devices or joint sealants at the curb. TERMINAL (See Roadway plans for ends not attached to Guard Rail.) bolt with hex nut and lock washer 2 x 2 threaded anchor studs with hex nuts, hardened washers, and lock washers automatically end welded to tube. #4 Cont. (tot. 5) #4 spa as shown. 21 x 1 0 A325 or A 449 bolts with hex nuts and lock washers (Proj ) anchor 1 6 7 1R 3 Places Used when placed on concrete slab. 1 1 2 11 9 9 1 6 asphalt overlay, Silica Reflector tab at each post. See M6061 for details Fum e overlay or future EXPANSION DEVICE overlay for bare decks Slab reinforcing 1 1 4 8 4 1 holes Bar x x 6 ANCHOR DETAIL hole in post PL 10 8 #4 typical 5 1 1 1 1 holes and anchor PLAN POST DETAIL 4 1 x 1 slots 1 6 7 TRANSITION 4 (See roadway plans for ends requiring attachment to guard rail.) Traffic face of post 1 x 1 horizontal slots in post at tube hole between tubes for reflector mount tab mount. Chamfer traffic face of curb x 6 1 6 3 0 hole at tube splice, and 1 x 4 slots at bridge exp n device. 5 Optional drain hole in post for galvanizing 4 7 4 2 11 ELEVATION Slot both inner and outer tubes. Stagger top and bottom splices into different post spacings except at expansion joint, place at opposite End of sleeper ends of same post space. (Range of motion = 1 0 at bridge expansion device.) 1 9 1 x 1 horizontal slots TS 5 x 5 x.3125 respectively. snug only. grade. Tube 4 x 4 from A572 PL expansion joints. tubes and 1 x 6 A325 bolts, hex nuts, All posts and base plates shall be ASTM A572 Grade 50. All other steel shall be ASTM A36 unless otherwise noted. The above material and all anchor bolts and miscellaneous bolts, nuts, and washers shall be galvanized after fabrication in accordance with Section 509. Concrete, reinforcing steel, and structural steel elements shall conform to the requirements of sections 601, 602 and 509, Post anchor, encased in concrete, shall be ASTM A36 (AASHTO M183) steel and need not be galvanized. The tubes shall be shop bent or fabricated to fit horizontal curve when radius is less than 1,500 feet. Tubes shall be continuous over not less than two posts. No welded butt splices will be allowed in the tube sections. The centerline of the tube splice shall be 1 8 minimum and 2 6 maximum from the centerline of the posts. All bolts that have lock washers shall be tightened to Posts shall be perpendicular to the longitudinal roadway One or more 10 0 post spacings may be reduced (6 8 min.) in order to maintain dimensions from the end of the rail and Payment will be made under item 606, Bridge Rail type 10M for all posts, post anchors, base plates, backing plates, anchor bolts, miscellaneous bolts, nuts, washers, tubes, tube expansion devices, tube splices, end plates, curb concrete (Class D), curb reinforcing steel, and reflector tabs. Prior to fabrication of this item, three sets of working drawings which comply with the requirements of section 105, shall be submitted to the Engineer for information only. Structural Steel: AASHTO M183 (ASTM A36) AASHTO M223 (ASTM A572) GRADE 50 COLD FORMED ASTM A500 GRADE B For additional details see next rail sheets. x.375 x 3 0 fabricated washers, and lock washers. INFORMATION ONLY DESCRIPTION Concrete Class D (Bridge) Reinforcing Steel (Epoxy Coated) fy = 36,000 psi fy = 50,000 psi fy = 46,000 psi UNIT LB. CU.YD. LB. PER LIN. FT. 45.1.06 6.6 Print $DATE$ File Name: Sheet_B60610.dgn BRIDGE RAIL TYPE 10M Project No./ Unit 022X Unit Leader er: XX Detailer: XX Structure XXXXX Numbers XXXXX Subset Sheets: BXX of

A B60610A (Use with B60610) 8 min. 1 max. 8 2 5 1 7 Backing plate 2 End plate (typ) 11 2 3 Backing plate Bridge rail tubes H.S. bolt # 4 cont. 1 6 1 1 DATE DATE DATE 3/99 11/99 5/00 5/01 4/02 6/04 3/07 10/13 1 hole in tubes for H. S. bolt of curb x 6 6 Approach slab post A Sleeper slab Expansion device RAIL TUBE DETAILS (tot. 4) (Use with Bridge Rail Type 10M) Thrie beam not shown. A 2 5 8 1 7 8 min. 1 max. End plate Backing plate 2 2 post drain hole 3 3 # 4 A Holes are 1 for H. S. bolts with hex nuts, 2 PL washers, and 1 lock washer Flush on roadway side 1 hole in tube for H. S. bolt (typ) min. end plate of curb x 6 6 A RAIL TUBE DETAILS PL x 12 x 16 (A36) x 7 H. S. bolts Field drill terminal section to match these bolt locations 8 BACKING PLATE 2 7 3 2 END PLATE DETAIL 3 x H.S. bolts (tot. 3) spa. as shown. asphalt overlay, silica fume overlay or future overlay for bare decks. Use when curb is placed on top of wall 2 0 1 6 1 1 Exp n Joint Mat l asphalt overlay, silica fume overlay or future overlay for bare decks. (Use when curb is to be placed on approach slab.) ed By (Use with Bridge Rail Type 10H) or 10R Thrie beam not shown. Print $DATE$ File Name: Sheet_B60610A.dgn BRIDGE RAIL TYPE 10M Project No./ Unit 022X Unit Leader er: XX Detailer: XX Structure XXXXX Numbers XXXXX Subset Sheets: BXX of

8 min. 1 max. Limits of pay length for Bridge Rail Type 10H (For post spacing, see Dwg. No. B ) 2 5 10 0 Max. 10 0 Max. post spacing 10 0 Max. 8 min. 1 x 1 slotted 1 max. Post holes at splices. section connector. Post B60610H (Use with Type 3G or 3H Transition B60610A) (See Roadway Quantities) The height of the Transition will vary to match bridge rail and roadway guardrail: 1 when CBC has a overlay. 2 8 hole in post. 1 x 1 slotted holes in post. when CBC has a silica fume overlay NOTES DATE DATE DATE 10/98 3/99 11/99 5/00 5/01 4/02 3/07 10/13 TERMINAL (See roadway plans for ends not attached to Guardrail) 2 x threaded anchor studs with hex nuts, hardened washers, and lock washers automatically end welded to tube. bolt with hex nut and lock washer. 1 6 5 Optional drain hole in post for galvanizing. For details and reinforcing of headwall and slab, see Dwg. No. B 21 X 1 0 A325 or A449 bolts with hex nuts and lock washers (Proj ) 1 6 7 3 1R TRANSITION Anchor Reflector Tab at each post. See M6061 for details 11 2 11 1 9 2 8 Fil asphalt overlay W/O fil, silica fum e overlay W/O fil or roadway pavem ent thickness 1 4 1 ANCHOR DETAIL 1 holes Bar 2 x x 6 TS 4 x 4 x.375 x 3 0 (May be fabricated from A572 PL) 5 8 4 of curb x 6 (See roadway plans for ends requiring attachment to Guardrail) 10 8 1 Traffic face of post 1 x 1 horizontal 1 1 PL 1 holes and anchor PLAN POST DETAIL slots in post at tube. hole between tubes for reflector tab mount. All tubes shall be ASTM A500 Grade B. All posts and base plates shall be ASTM A572 Grade 50. All other steel shall be ASTM A36 unless otherwise noted. The above material and all anchor bolts and miscellaneous bolts, nuts, and washers shall be galvanized after fabrication in accordance with Section 509. Concrete, reinforcing steel, and structural steel elements shall conform to the requirements of Sections 601, 602 and 509, respectively. Post anchors, encased in concrete, shall be ASTM A36 (AASHTO M183) steel and need not be galvanized. The tubes shall be shop bent or fabricated to fit horizontal curve when radius is less than 1,500 feet. Tubes shall be continuous over not less than two posts. No welded butt splices will be allowed in tube sections. The centerline of the tube splice shall be 1 8 minimum and 2 6 maximum from the centerline of the posts. All bolts that have lock washers shall be tightened to snug only. Posts shall be perpendicular to the longitudinal roadway grade. One or more 10 0 post spacings may be reduced (6 8 min.) in order to maintain dimensions from the end of the rail and expansion joints. Payment will be made under Item 606, Bridge Rail Type 10H for all posts, post anchors, base plates, backing plates, anchor bolts, miscellaneous bolts, nuts, washers, tubes, tube splices, end plates, and reflector tabs. which comply with the requirements of Section 105, shall be submitted to the Engineer for information only. 3 0 Structural Steel: 1 6 AASHTO M183 (ASTM A36) fy= 36,000 psi AASHTO M223 (ASTM A572) fy= 50,000 psi fy= 46,000 psi Cold formed ASTM A500 Grade B 4 7 4 4 7 4 For additional details see next rail sheets Tubes and 1 x 6 A325 bolts, hex nuts, washers, and lockwashers. INFORMATION ONLY Description Unit Finished Grade 1 x 1 slots Lb 45.1 Slot both inner and outer tubes. Concrete Class D (Bridge) CY ed By Stagger top and bottom splices into different post spacings. Reinforcing Steel (Epoxy Coated) Lb Print $DATE$ File Name: Sheet_B60610H.dgn Unit 022X Unit Leader BRIDGE RAIL TYPE 10H HEADWALL MOUNTED er: XX Structure XXXXX Detailer: XX Numbers XXXXX Subset Sheets: BXX of Project No./

Limits of pay length for Bridge Rail Type 10R (For limits, see Dwg. No. B ) Type 3G or 3H Transition See Std. M6061 B60610P (Use with B60610A) 3 Min. 3 8 Max. 10 0 Typical post spacing 10 0 Max. Post Post 1 8 (min.) 2 6 (max.) (typical) section connector. 3 Min. 3 8 Max. 2 5 The height of the Transition will vary to match bridge rail and roadway guardrail: 1 when bridge deck has a overlay. All tubes shall be fabricated from ASTM A500 Grade B. All when bridge deck has a silica fume posts and tube splices shall be fabricated from ASTM A572 overlay and 4 when bridge deck does not Grade 50 or ASTMA588 steel. All miscellaneous steel shall be have an overlay. fabricated from ASTM A36 steel. The above material, except as noted, and all anchor bolts and miscellaneous bolts, nuts and washers shall be galvanized after See Section End lag screw fabrication in accordance with Section 509. Structural steel elements shall conform to the requirements of Section 509. Tubes shall be continuous over not less than two posts. No welded butt splices will be allowed in the tube sections All bolts that have lock washers shall be tightened to snug only. Posts shall be perpendicular to the grade of the deck. DATE DATE DATE ed By 3/99 11/99 5/00 4/02 3/07 10/13 1 7 deck thickness +1 7 3 Min. 3 8 Max. BF Abutment (See Roadway plans for ends not attached to Guardrail) and hardened lock washers. 11 5 1 Timber stringer TERMINAL 2 x threaded anchor studs automatically end welded to tube. Attach to post with hex nuts (Typ.) holes L 2 x 3 x x 0 7 2 H.S. bolts bolts with lockwashers (6 ea. post) pilot holes for drilling of stringer W 6 x 25 x 5 0 1 1 40 (drain spacing) install flush at traffic face of wheel guard and locate to miss tube splice and posts. Reflector 4 1 x 1 10 Lag Screws with washers and lock washers (1 on each side of post, except at splice, and 2 equally spaced between each post) Bent PL x 1 4 x 1 4 @ each post. Remove any existing 1 at traffic asphalt planking so that the plate face and 1 at back, for drainage. may be attached directly to the deck. 1 9 1 Brush on asphaltic pitch coat over bolts See M6061 for details attach to post with bolt with hex nut and lock washer and plate L 2 x 3 x (size to fit) 2 11 8 x 8 schedule 40 HBP pipe drain through Corrugated Steel Bridge Plank Timber Stringer er: Drains optional TRANSITION (See Roadway plans for ends requiring wheel guard PL x 3 x 1 (two at each post) H.S. bolts (2 ea. post) L 2 x 3 x @ each post Existing timber wheel attachment to guardrail) guard shall be removed. Shall not be galvanized. Shall be painted in the field after installation. Paint in accordance with section 509. Adjust per relative position of steel deck corrugations hole in post L 2 x 3 x x 0 7 at each post 6 6 3 Min. 3 8 Max. TS 12 x 6 x 0.1875 5 1 1 ELEVATION Cut tab to fit W 6 x 25 Post Traffic BF Abutment 6 1 x 1 slotted holes in post 5 PL x 1 x 4 1 x 1 drain hole at bottom slots at tube splice. 5 1 6 7 4 Slot both inner and outer tubes. (preservative). Structural Steel: AASHTO M222 (ASTM A588) or AASHTO M223 (ASTM A572) AASHTO M183 (ASTM A36) Cold formed ASTM A500 Grade B For additional details see next rail sheets 3 0 Stagger top and bottom splices into different post spacings. Place at opposite ends of same post space. Posts, backing plates, miscellaneous plates, angles, lag screws, miscellaneous bolts, nuts, washers, tubes, tube splices, end plates, reflector tabs, galvanizing and painting shall be included in Item 606 Bridge Rail Type 10R. shall be submitted to the Engineer for information only. Treat all bolt holes in timber with an acceptable timber treatment Use similar detail at 1 X 6 wheel guard tubing, using a fabricated splice tube of 11 x 5 x. Vertically center 1 x 1 10 lag screws in slotted holes in tube splices. Screws must go through deck and into stringer. 4 7 4 FOR INFORMATION ONLY Description f y = 50,000 psi f y = 36,000 psi f y = 46,000 psi TS 4 x 4 x x 3 0 (May be fabricated from A572 PL 3/8) Tubes and 1 x 6 H.S. bolts, hex nuts, washers and lockwashers. Unit Lb. 81.3 Print $DATE$ File Name: Sheet_B60610P.dgn Unit 022X Unit Leader BRIDGE RAIL TYPE 10R REPLACEMENT RAIL er: XX Structure XXXXX Detailer: XX Numbers XXXXX Subset Sheets: BXX of Project No./

Limits of pay length for Bridge Rail Type 10R (For post spacing, see Dwg. No. B ) B60610R (USE WITH B60610A) 10 0 Max. 10 0 Max. post spacing 10 0 Max. 1 x 1 slotted 1 x 1 slotted holes in post. post 1 x 4 slotted Post holes at splice. holes at bridge expansion device. section connector. 2 5 Type 3G or 3H Transition. (See Roadway Quantities) The height of the Transition will vary to match bridge rail and roadway guardrail: 1 when bridge deck has a overlay, when bridge deck has a silica fume overlay and 4 when bridge deck does not have an overlay. DATE DATE DATE ed By 10/98 3/99 11/99 5/00 5/01 4/02 3/07 10/13 2 8 (See Roadway plans for ends not attached to Guard Rail.) er/detailer: Change as per project (1 min. for this post and base plate) 1 7 anchor bolt with hex nut and lock washer. Open joint in curb to match location and width of any joint in the supporting slab. See slab joint details for treatment of any expansion devices or joint sealants at the curb. 5 11 6 min. 2 2 8 EXPANSION DEVICE ON WING TERMINAL TRANSITION Reflector Tab at each post. 2 x threaded See M6061 anchor studs with hex for details nuts, hardened washers, and lock washers automatically end welded to tube. Optional drain hole in post for galvanizing. 21 fully threaded A449 galvanized rods with hex nuts and lock washers. Rods to be set in 1 cored holes with an approved epoxy grout. Holes shall be 2 0 deep at wingwalls. The coring of holes and epoxy grout to be included in the bid price for Item No. 606 Bridge Rail Type 10R. Installed rods shall not project more than beyond the nut. er/detailer: 8 min. and 1 max. preferred. However, check existing bridge(s) for skew, expansion joint, and wingwall details at the end of the curbs and adjust this dimension as necessary. If there is insufficient room for the first 3G guardrail post, shown above, off the end of the bridge, then extend bridge rail tubes beyond the end of the curb. Do not change the 2 5 shown above. This will move the first 3G post away from the curb. asphalt overlay, silica fum e overlay or future overlay for bare decks. 5 hole in post. of curb x 6. (See roadway plans for ends requiring attachment to guardrail.) The above material and all anchor bolts and miscellaneous bolts, nuts, and washers shall be galvanized after fabrication in accordance with Section 509. Concrete, reinforcing steel, 10 and structural steel elements shall conform to the requirements of Sections 601, 602 and 509, respectively. See note 8 1 Traffic face of post The tubes shall be shop bent or fabricated to fit horizontal curve when radius is less than 1,500 feet. 1 x 1 8 4 Keep weld clear of anchor bolt holes. 3 0 1 6 PL 1 1 1 holes and anchor PLAN POST DETAIL horizontal slots in post at tube. hole between tubes for reflector tab mount. 4 7 4 4 7 4 Tube 4 x 4 x.375 x 3 0 fabricated from A572 PL Structural Steel: AASHTO M183 (ASTM A36) fy= 36,000 psi AASHTO M223 (ASTM A572) Grade 50 fy= 50,000 psi tubes and Cold formed ASTM A500 Grade B fy= 46,000 psi 1 x 6 A325 bolts, hex nuts, washers and lockwashers. 1 x 1 slots All tubes shall be ASTM A500 Grade B. All posts and base plates shall be ASTM A572 Grade 50. All other steel shall be ASTM A36 unless otherwise noted. Tubes shall be continuous over not less than two posts. The centerline of the tube splice shall be 1 8 minimum and 2 6 maximum from the centerline of the posts. All bolts that have lock washers shall be tightened to snug only. Posts shall be perpendicular to the longitudinal roadway grade. One or more 10 0 post spacings may be reduced (6 8 min.) in order to maintain dimensions from the end of the rail and expansion joints. Payment will be made under Item 606, Bridge Rail Type 10R for all posts, base plates, backing plates, anchor bolts, miscellaneous bolts, nuts, washers, tubes, tube expansion devices, tube splices, end plates, cored holes, grout, and reflector tabs. which comply with the requirements of Section 105, shall be submitted to the Engineer for information only. For additional details see next rail sheets. INFORMATION ONLY TS 5 x 5 x.3125 Description Unit at tube splice, and 1 x 4 slots at bridge expansion device. Slot both inner and outer tubes. Stagger top and bottom Lb 45.8 Finished Grade splices into different post spacings except at expansion joint, place at opposite ends of same post space. (Range of Bar 3 x 3 x with motion = 1 0 at bridge. expansion device.) 1 holes. Print $DATE$ File Name: Sheet_B60610R.dgn BRIDGE RAIL TYPE 10R REPLACEMENT RAIL Project No./ Unit 022X Unit Leader er: XX Detailer: XX Structure XXXXX Numbers XXXXX Subset Sheets: BXX of

Limits of pay length for Bridge Rail Type 10R (For limits, see Dwg. No. B ) B60610T Type 3G Transition. See Std. M6061 (Use with B60610A) 3 Min. 10 0 Typical post spacing 10 0 Max. 3 8 Max. Post 1 8 (min.) Post 3 Min. 3 8 Max. 2 5 The height of the Transition will vary to match bridge rail and roadway guardrail: 1 when bridge deck has a overlay. when bridge deck has a silica fume overlay and 4 when bridge deck does not All tubes shall be fabricated from ASTM A500 Grade B. All posts and tube splices shall be fabricated from ASTM A572 Grade 50 or ASTMA588 steel. All miscellaneous steel shall be 2 6 (max.) have an overlay. fabricated from ASTM A36 steel. section connector. The above material, except as noted, and all anchor bolts and miscellaneous bolts, nuts and washers shall be galvanized after See Section End lag screw fabrication in accordance with Section 509. Structural steel elements shall conform to the requirements of Section 509. Tubes shall be continuous over not less than two posts. No welded butt splices will be allowed in the tube sections. All bolts that have lock washers shall be tightened to snug only. Posts shall be perpendicular to the grade of the deck. 3/99 11/99 5/00 4/02 3/07 10/13 3 Min. 3 8 Max. BF Abutment (See Roadway plans for ends not attached to Guardrail) and hardened lock washers. Timber stringer TERMINAL 2 x threaded anchor studs automatically end welded to tube. Attach to post with hex nuts 40 (drain spacing) Install flush at traffic face of wheel guard and locate to miss tube splice and posts. Reflector 4 1 x 1 10 Lag Scews with 2 11 er: Drains Optional TRANSITION (See Roadway plans for ends requiring attachment to Guardrail) hole in post 6 3 Min. BF Abutment 3 8 Max. TS 12 x 6 x 0.1875 6 Cut tab to fit Traffic 6 1 x 1slotted holes in post drain hole at bottom PL x 1 x 5 Posts, backing plates, miscellaneous plates, angles, lag screws, miscellaneous bolts, nuts, washers, tubes, tube splices, end plates, reflector tabs, galvanizing and painting shall be included in Item 606 Bridge Rail Type 10R. shall be submitted to the Engineer for information only. Treat all bolt holes in timber with an acceptable timber treatment (preservative). Strucural Steel: AASHTO M222 (ASTM A588) or fy= 50,000 psi AASHTO M223 (ASTM A572) fy= 36,000 psi AASHTO M183 (ASTM A36) fy= 46,000 psi Cold formed ASTM A500 Grade B DATE DATE DATE ed By 1 Deck thickness 1 7 +1 11 5 2 H.S. bolts bolts with lockwashers (6 ea. post) pilot holes for drilling of stringer washers and lock washers (1 on each side of post, except at splice, and 2 equally spaced between each post) W 6 x 25 x 5 0 See M6061 for details attach to post with bolt with hex nut and lock washer Existing timber wheel guard shall be removed. 1 4 Bent PL x 1 4 x @ each post Remove any existing 1 at traffic asphalt planking so that the plate face and 1 at may be attached directly to the deck. back, for drainage. 1 9 1 Brush on asphaltic pitch coat over bolts and plate 8 x 8 schedule 40 pipe drain through HBP wheel guard Timber Deck Gusset PL x 7 x 1 at each post PL x 7 x 12 Timber Stringer at each post 5 PL x 7 x 1 at each post 1 1 W 6 x 25 Post ELEVATION 5 For additional details see next rail sheets 3 0 1 6 TS 4 x 4 x.375 x 3 0 (May be fabricated from 4 7 4 4 7 4 A572 PL ) Tubes and 1 x 6 H.S. bolts, hex nuts, washers and lockwashers. 1 x 1 slots at tube splice. Slot both inner and outer tubes. Stagger top of bottom splices into different post spacings. Place at opposite ends of same post space. Use similar detail at 1 X 6 wheel guard tubing, using a fabricated splice tube of 11 x 5 x. Vertically center 1 x 1 10 lag screws in slotted holes in tube splices. Screws must go through deck and into stringer. FOR INFORMATION ONLY Description Unit Lb 81.3 Print $DATE$ File Name: Sheet_B60610T.dgn BRIDGE RAIL TYPE 10R REPLACEMENT RAIL Project No./ Unit 022X Unit Leader er: XX Detailer: XX Structure XXXXX Numbers XXXXX Subset Sheets: BXX of