K-PATENTS PROCESS REFRACTOMETER PR-23-RP

Similar documents
A PROCESS REFRACTOMETER FOR CONCENTRATION MEASUREMENT OF LIQUIDS K-PATENTS PROCESS REFRACTOMETER PR-23-GP SB:PR-23-GP/0

A PROCESS REFRACTOMETER FOR CONCENTRATION MEASUREMENT OF LIQUIDS K-PATENTS PROCESS REFRACTOMETER PR-23-GP SB:PR-23-GP/0

Refractometer. MONITORED CHEMICALS Acetic acid CH 3

1. Instrument diagnostics Interpreting the Optical Image and Diagnostic Values Prism washing... 8

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Applications Features

Servo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability.

Digital conductivity transmitter

Flow Measurement SITRANS F M

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

mass flowmeter for compressed air

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Total Consistency Measurement. Metso Microwave Consistency Transmitter

DigitalFlow XMT868i. Panametrics Liquid Flow Ultrasonic Transmitter. GE Measurement & Control. Applications. Features

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Magnetic Flowmeter Systems

Technical Information Smartec CLD18

The transducer component converts the measured signal and displays the actual value.

ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging.

Digital inductive conductivity transmitter

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

Model Sono-Trak Transit Time

oxy.iq Panametrics Oxygen Transmitter Applications Features bhge.com Two-wire, loop-powered 4 to 20 ma transmitter An oxygen transmitter for use in:

Features. NULL-KOTE Circuitry Makes the sensor immune to adverse effects of conductive coating build up.

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

Technical Information Smartec CLD18

Sarasota CM200 Sarasota HME900 Density Converter Electronics

RCM DIRECT READING FLOWMETER

ABB FCB330 FCH350 Mass Flowmeter datasheet

OPTISONIC 7300 Technical Datasheet

Technical Information Smartec CLD18

Electro-Magnetic Flowmeters COPA-XE

DigitalFlow DF868. Panametrics Liquid Ultrasonic Flowmeter. GE Measurement & Control. Applications. Features

TIDALFLUX 2300 F Technical Datasheet

Technical Information Condumax CLS21D/CLS21

B850 Boiler House Energy Monitor

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

OPTIFLUX 5000 Technical Datasheet

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

Mass Flowmeter CoriolisMaster FCM2000

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

Technical specification PIOX R400-*CTF

Flow Measurement SITRANS F M

B850 Boiler House Energy Monitor

Micro Motion Fork Viscosity Meters

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

Conductivity measurement SmarTec S CLD 132

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

E l e c t r o m a g n e t i c f l o w m e t e r s

Float Switches with Permanent Magnet For Vertical Installation Model RSM

CoriolisMaster FCB330, FCB350, FCH330, FCH350 Coriolis mass flowmeter

ANALYTICAL - COMPLEXITY MADE SIMPLE

DigitalFlow DF868 Panametrics Liquid Ultrasonic Flowmeter. GE Sensing. Applications. Features

Parts Per Million Dissolved Oxygen Systems

Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter

OPTIFLUX 5000 Technical Datasheet

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

Electromagnetic flowmeters and switches DWM 1000/2000

PanaFlow HT. Panametrics Ultrasonic SIL Flow Meter for Liquids. GE Measurement & Control. Applications. Features & Benefits

PSI Temperature Scanners

Non-Submersible Industrial Pressure Transducer

REFLEX RADAR INDICATOR

Conductive conductivity measurement mypro CLM 431 / CLD 431 conductive

TMU. Coriolis Mass Flow Meter. for liquids and gas

Flow Measurement SITRANS F US Clamp-on

Micro Motion Fork Density Meters

Mass Flowmeter CoriolisMaster FCM2000

ph or ORP Transmitter

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)

Technical Information Memosens CLS82D

4.00 ULTRASONIC ANALYZER

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

UTM10 Series Ultrasonic Transit-time Flowmeters

KFS. Flap-type flow meter. Design and range of application

MEAS CAL ALARM CONF APT2000 TC

Coriolis Massflowmeter

Conductivity Sensor for High-Temperature Applications ConduMax W CLS 13

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

Magnetostrictive Level Transmitter

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

BATAILG TAIL GAS ANALYZER. Rev. 1.1

Technical Information OUSBT66

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

6.00 INFRARED ANALYZER

Level Measurement Continuous level measurement Radar transmitters

EN-2018 MAGNETIC FLOW METERS

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display

Level Plus. RefineME Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology

Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

OPTIWAVE 1010 Technical Datasheet

Magnetic Inductive Flowmeter

LST400 Ultrasonic level / open channel flow transmitter

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Transcription:

A PROCESS REFRACTOMETER FOR LIQUID CONCENTRATION MEASUREMENT FOR THE OIL AND GAS INDUSTRIES K-PATENTS PROCESS REFRACTOMETER PR-23-RP SB:PR-23-RP/1 March 2016

TYPICAL APPLICATIONS UPSTREAM, MIDSTREAM AND DOWNSTREAM OPERATIONS K-Patents Process Refractometer PR-23-RP is used in the upstream, midstream and downstream operations of the fuel oil refining and petrochemical industry. TRANSPORTATION Interface detection for gathering and transportation operations, distribution pipelines, supply and delivery stations, and railcar and truck loading and unloading: Crude oil, fuel oil, diesel oil, hydrocarbon, refined products and alternative fuels. SULFURIC ACID ALKYLATION Acid catalyst, spent acid recovery. HYDTROTREATING Aromatic content of the hydrocarbon stream. NATURAL GAS PROCESSING Glycol dehydration, Amine gas treating: H 2 S and CO 2 removal. K-PATENTS PROCESS REFRACTOMETER PR-23-RP

INSTALLATION NON-WELD SENSOR BODY AND CROSS FLOW CELL OPERATION K-Patents Process Refractometer PR 23 RP sensor is factory calibrated to measure refractive index n D and temperature T in standard units. Each sensor has identical calib ration n D =1.32...1.53 (corresponding to 0-100 % by weight). One or two sensors can be connected to one indicating transmitter. K-Patents Process Refractometer PR 23 RP is a heavy-duty refinery model designed to meet the unique requirements of the refining and petroleum industries. Typical applications include accurate liquid concentration measurements, e.g. acid in alkylation, glycol or amines in gas processing and multi-product (crude oil, fuel oil, diesel) interfaces in transfer operations. The Refractometer sensor is installed in the process, either directly by welding stud, or via a 1 inch, 2 inch or 3 inch cross flow cell. Due to the sensor s rugged, innovative non-weld sensor body, and self-cleaning or optional automatic wash system capabilities, the PR-23-RP functions accurately and reliably in harsh refinery conditions. Intrinsically safe and hazardous area certification is provided for hazardous areas. The PR-23-RP comes with user-specified supplementary tests and documents. The following items can be specified and ordered: metallurgical and material hardness certification (e.g. compliance with the NACE MR0103 or NACE MR0175/ ISO 15156 standard), API recommended tests and welding documents (e.g. WPS, PQR, WQR, NDE, radiographic test and hydrostatic shell test), material traceability certification and the positive material identification (PMI) test. A factory acceptance test (FAT), site acceptance test (SAT), and customized drawings stating client specific information are also available on request. Measurement accuracy is unaffected by undissolved particles and impurities, bubbles, and color or temperature changes in the process medium. The K-Patents PR 23-RP does not require recalibration or regular maintenance. Because PR-23 sensors have identical calibration, and each sensor gives the Refractive Index nd and temperature as outputs, all sensors can be freely inter changed without the inconvenience of optical calibration or parameter changes. Non-linear conversion from the refractive index to concentration units and temperature compensation are based on standard tables. These are programmed into the transmitter, independently of the sensor. K-Patents' manufacturing process is ISO 9001 certified. K-Patents also supports verification as part of the user's own quality system. Each sensor is provided with a calibration certificate comparing a set of standard liquids to actual sensor output. Calibration and accuracy can therefore easily be verified on-site, using certified refractive index liquids and the K-Patents documented verification procedure.

DIGITAL MEASUREMENT PRINCIPLE DATA LOGGING VIA ETHERNET Light source Prism Critical angle Process medium Optical image K-Patents PR-23-RP includes an Ethernet -based communications solution, which allows connection to computer networks (LAN) and to the Internet. Real-time measurement data and diagnostic information can be obtained through this interface, making it a valuable service tool for parameter changes and software updates. Only a cross-over cable and data acquisition software are needed for collecting data from a PR-23 refractometer. Communication is built on standard protocols (UDP/IP) and K-Patents offers ready-toinstall data acquisition software. The light source emits light at the interface, between a prism and the process solution, where the rays meet the surface at different angles. Light source Prism Reflected light The angle corresponding to the shadow line is called the Critical Angle of Total Reflection. The Critical Angle is a function of the refractive index and therefore the con cen tration of the solution. This software is expandable if the user wishes to modify the program. Being written in Java, the program is system independent and can be tailored to almost any computing environment. Critical angle Solution Refracted light Depending on the angle, some rays undergo a total internal reflection. The rest of the light is refracted into the process solution. A digital CCD-camera detects the optical image and shadow line. The camera transforms the optical image point by point into an electrical signal. In this way, the exact shadow line position is located and the refractive index n D is determined. A built-in temperature sensor measures the temperature T on the interface of the process liquid. The indicating transmitter converts the refractive index n D and temperature T into concentration units. Thus, an optical image with a dark and light sector is created. The diagnostics program ensures that the measurement is reliable.

DESIGN Air cooling fins Processor card Thermal conductor Thermal isolation CCD-camera Light source One-piece body construction with no welds CORE-Optics PTFE Prism gasket All measuring components (light source, prism, temperature sensor and CCD camera) are in one solid CORE optics module. Prism Temperature sensor The patented CORE-optics are mechanically isolated from external forces and vibrations. In addition, they require no mechanical adjustments. (US Patent No. 6067151)

[6.50] Ø165 SPECIFICATIONS Sensor PR-23-RP AISI 304 AISI316L 2" ANSI 300 AISI316L flange Sensor PR-23-RP and Cross flow cell CF-RP-M20-M10 for 1 inch pipe line size Indicating transmitter DTR 0,81 20,7 11,79 299,5 Sensor PR-23-RP for pipe line [18,88] 480 [12.53] 318 [8,88] 226 [0.79] 20 [2.38] Ø60.4 5,12 130 1,77 Ø 45 [0,77] 20 Ø88.9 [3"] or larger Refractive Index range: Standard: Full range, n D = 1.3200...1.5300 (corresponds to 0...100 % b.w.) Accuracy: Refractive index n D ±0.0002 (typically corresponds to ± 0.1% by weight) Repeatability n D ±0.0001 (typically corresponds to ±0.05% by weight) Speed of response: 1 s undamped, damping time selectable up to 5 min Calibration: With Cargille standard R.I. liquids over full range of n D 1.3200...1.5300 CORE-Optics: No mechanical adjustments (US Patent No. US6067151) Digital measurement: 3648 pixel CCD element Light source: Light emitting diode (LED), 589 nm wavelength, sodium D-line Temperature sensor: Built-in Pt-1000, linearization according to IEC 751 Temperature compensation: Automatic, digital compensation Instrument verification: According to ISO 9000 quality system: with standard R.I. liquids and Transmitter's menu guided procedure Ambient temperature: Sensor: max. 45 C (113 F), optional max. 65 C (149 F), min. -20 C (-4 F) Indicating transmitter: max. 50 C (122 F), min. 0 C (32 F) SENSOR PR-23-RP AND CROSS FLOW CELL CF-RP: Sensor type: Probe type, seamless one-piece wetted parts construction with no welds Process connection: ANSI-flange 300 lbs, 2 inches, insertion length 130 mm (51 inches) Cross Flow Cell process connection: ANSI-flange 300 lbs for nominal pipe sizes of 1 inch, 2 inches or 3 inches Process pressure: up to 25 bar (350 psi) Process temperature: -40 C...150 C (-40 F...302 F) Process wetted parts, standard: AISI 316L stainless steel, Alloy 20 or Hastelloy C-276; prism sapphire, prism gaskets PTFE Sensor protection class: IP67, Nema 4X Sensor weight: 7.89 kg (17.4 lbs) Cross flow cell weight: 10.9 kg (24 lbs) ASME Code compliance: The main physical properties have been designed in accordance with ASME Section VIII, Division 1 and Division 2 INDICATING TRANSMITTER DTR: Display: 320x240 pixel graphical LCD with LED backlight Keypad: 18 membrane keys Current output: Two independent current outputs, 4-20 ma, max. load 1,000 Ohm, galvanic isolation 1,500 VDC or AC (peak), hold function during prism wash Ethernet connection: 10/100 Mbit/s, data acquisition over UDP/IP Protocol with K-Patents PR-11111 data logging software Power: AC input 100-240 VAC/50-60 Hz, optional 24 VDC, 30 VA Alarms/Wash relays: Two built-in signal relays, max. 250 V/3 A Sensor connectivity: One or two sensors can be connected to the DTR. Sensors independent of each other: own parameter sets and usable in different applications. Two current outputs configurable independently to indicate process concentration or temperature of either sensor. Transmitter protection class: Enclosure IP66, Nema 4X Indicating transmitter weight: 4.5 kg (10 lbs) INTERCONNECTING CABLE: IEC 61158-2 compliant two-wire cable Interconnecting cable length: Standard 10 m (33 ft), max. 200 m (660 ft) OPTIONS: Prism wash, intrinsic safety and hazardous area approvals, cable fittings to the indicating transmitter: European cable glands M20x1.5 or US conduit hubs ORDERING INFORMATION: - Sensor model and process connection - Desired scale - Properties of process solution - Process temperature range - User specified tests and documents - Process pipe size - Process flow rate - Supply voltage and frequency - Options and accessories K-PATENTS OY P.O. BOX 77 ELANNONTIE 5 FI-01511 VANTAA, FINLAND PHONE: INT.+358-207-291 570 FAX: INT.+358-207-291 577 INFO@KPATENTS.COM WWW.KPATENTS.COM K-PATENTS, INC. 1804 CENTRE POINT CIRCLE, SUITE 106 NAPERVILLE, IL 60563 U.S.A. PHONE: (630) 955 1545 FAX: (630) 955 1585 INFO@KPATENTS-USA.COM WWW.KPATENTS.COM We reserve the right to make technical alterations.