Modular equipment. Presentation, standards. Standard contactors TeSys GC

Similar documents
TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

Characteristics 5 TeSys k contactors and reversing contactors

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

3 - Protection components Circuit-breakers

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

Motor starters. TeSys E. Designed for the essential

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7

NS..S contactor relays - with spring terminals AC operated

Protection components

Protection components

Components for safety applications

RE7RL13BU off-delay timing relay with control contact s - 24 V AC DC - 2OC

RE7TP13BU adjustable on-delay timing relay s - 24 V AC DC - 2OC

Technical features table for miniature circuit-breakers SH 200 Series

RE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC

Pendant control stations 6

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M

Control relays. K mini-control relays. 2 or 4 for CA2-K and CA3-K: 2 for CA4-K. Conforming to VDE 0110 group C V 750

RE17LLBM asymmetrical flashing relay s V AC - solid state output

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Pendant control stations 6

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Zelio Control Measurement Relays

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

References 1 for asynchronous motors 1

Page 13-2 Page Page 13-7

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

Electronic timer CT-SDS.22

Zelio Plug-In Relays. RXG interface relays. Catalog

Capacitor Switching Contactors

Type CP-S, CP-C & CP-A Switch mode

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

Output of three-phase motors at 50 Hz and 400 V

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

(1,5 modules per pole)

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

Pendant control stations 6

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Contactors and Contactor Assemblies

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

TeSys H. Protection. Motor controllers. Reliable. Motor starters. Contactors. Circuit breakers. Smart. Ultra-compact 22.5 mm motor starters

Datasheet - PROTECT-IE-02

RXG12BD interface plug-in relay - Zelio RXG - 1C/O standard - 24VDC-10A-with LTB and LED

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Control module CP-A CM

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

Description Basic devices with positive operation contacts

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors.

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

Electronic timer CT-MFS.21

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

Controls Contactors and Contactor Assemblies Special Applications

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Electromechanical pressure and vacuum switches 0

Components for safety applications Preventa safety modules

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Three-phase monitoring relays

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

Three-phase monitoring relay CM-PFS

itl impulse relays IEC/EN itls: IEC/EN itls b Allows remote indication of its operating state (open/closed)

Type: DILEM 10(220V50HZ,240V60HZ) Article No.:

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Semiconductor contactors, Solid-state relays

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Type: DILM40(RDC24) Article No.:

Transcription:

Presentation, standards Standard contactors TeSys GC Presentation TeSys GC contactors are designed for use in modular panels and enclosures. These contactors feature: b Easy installation v quick clip-on fi xing and locking onto mm omega rail, v easy connection by means of ready-to-tighten, captive, pozidrive screw terminals. GC b Compact size All units have a common depth of 0 mm and width in modules of. mm (width of one module:. mm). b User safety v use of materials conforming to strictest fi re safety standards, v live parts protected against direct fi nger contact, v completely safe operation, v state indication on front panel. Standards This range of modular contactors has been designed taking into account the requirements of international standard IEC 0. This standard is specifi c to Electromagnetic contactors for domestic and similar use. It has very strict requirements, meeting the expectations of users, with regard to the safety of equipment and persons in premises and areas accessible to the public. Conformity with this standard makes it possible to obtain the following quality labels without the need for additional tests: NF-USE, VDE, CEBEC, etc. Applications TeSys GC modular contactors are designed for switching all single-phase, -phase or -phase loads up to 00 A. Power switching These contactors have multiple applications in industrial, agricultural and commercial premises, hospitals and the home, i.e. wherever switching of a specifi c supply is required: b lighting, b heating, b ventilation, b motorised shutters or gates. 0 pages 000/ to 000/ pages 000/ and 000/ pages 000/ and 000/ pages 000/ and 000/ 000-EN_Ver.0

Setting-up precautions Standard contactors TeSys GC Setting-up precautions The contactor controls must be bounce free. If not, connect a coil suppression block (GAP, or ) across the coil terminals y 0 V. When several contactors which operate at the same time are mounted side by side, a GAC ventilation / module must be fi tted every contactors. It is advisable to mount electronic units at the bottom of the modular panel and to separate them from electromechanical units by a space equal to one module, or by ventilation / modules (GAC ). Derating of contactors mounted in a modular enclosure if the temperature within the enclosure is > 0 C Contactor rating 0 C 0 C 0 C () A A A A A A A 0 A 0 A 0 A A A A A A 0 A 00 A 00 A A 0 A () Ventilation / module must be fi tted 0 pages 000/ to 000/ pages 000/ and 000/ pages 000/ and 000/ pages 000/ and 000/ 000-EN_Ver.0

Characteristics TeSys GC standard contactors Contactor type GC GC GC0 GC GC00 Environment Rated insulation voltage Conforming to IEC 0 V 00 (Ui) Conforming to VDE 00 V 00 Rated impulse withstand voltage (Uimp) Conforming to standards Product certifications kv in enclosure IEC 0, VDE 0- and IEC 0- for auxiliary contacts NF- USE, VDE, CEBEC, ÖVE Degree of protection Conforming to VDE 00 Protection against direct fi nger contact (IP 0 open, IP 0 in enclosure) Protective treatment Standard version TC Ambient air temperature around the device Storage C - 0 + 0 Operation C - + 0 (0.. Uc) Maximum operating altitude Without derating m 000 Operating positions Without derating ± 0 in relation to normal vertical mounting plane Shock resistance / sine wave = 0 ms Vibration resistance 00 Hz Contactor open Contactor closed Contactor open Contactor closed 0 gn gn gn gn Flame resistance Conforming to IEC 0 Pole characteristics Number of poles, or Rated operational current (Ie) (Ue y 0 V) In AC-a (heating) A 0 00 In AC-b (motor control) A. Rated operational voltage Up to V 0 two-pole contactors, three and four-pole contactors (Ue) Frequency limits Of the operating current Hz 00 Conventional thermal current (lth) Rated breaking and making capacity Permissible short time rating no current fl owing for preceding minutes with θ y 0 C Short-circuit protection by fuse or circuit breaker U y 0 V θ y 0 C A 0 00 Conforming to IEC 0 (AC-b) I rms 00 V -phase A 0 0 00 For 0 s A 00 0 0 00 For 0 s A 0 00 0 gl fuse A 0 00 Circuit-breaker I t (at ka rms prospective) 0 V A s 000 0 000 000 000 00 V A s 000 000 00 0 000 Average impedance per pole At lth and 0 Hz mω.. Power dissipated per pole Maximum cabling c.s.a. For the above operational currents W 0... 0 Flexible cable conductor mm without cable end conductors mm Flexible cable with cable end conductor mm conductors mm.. Solid cable conductor mm without cable end conductors mm 0 Tightening torque Power circuit connections N.m 0. 0.... 0 pages 000/ to 000/ pages 000/ and 000/ pages 000/ and 000/ 000-EN_Ver.

Characteristics (continued) TeSys GC standard contactors Contactor type GC, GC single or -pole GC, GC or -pole GC0, GC -pole GC0, GC or -pole GC00 -pole GC00 -pole Control circuit characteristics Rated control circuit voltage (Uc) 0 or 0 Hz V 0 V, for other voltages, please consult your Regional Sales Office Control voltage limits (θ y 0 C) Average coil consumption at 0 C and at Uc 0 Hz coils Operational 0.. Uc Drop-out 0. 0. Uc a 0 Hz Inrush VA 0 Sealed VA... Maximum heat dissipation 0/0 Hz W.... Operating time Closing C ms 0 0 Opening O ms 0 Mechanical durability In operating cycles 0 Maximum operating rate In operating cycles per 00 at ambient temperature y 0 C hour Maximum cabling c.s.a. Flexible cable without cable end Flexible cable with cable end or conductors mm. conductor mm. conductors mm. Solid cable without cable end or conductors mm. Tightening torque N.m 0. Instantaneous auxiliary contact characteristics Rated operational voltage (Ue) Up to V 0 Rated insulation voltage (Ui) Conforming to V 00 IEC 0- Conforming to V 00 VDE 00 Conventional thermal current (Ith) For ambient θ y 0 C A Mechanical durability Operating cycles 0 Maximum cabling c.s.a. Flexible or mm. solid conductor Tightening torque N.m 0. 0 pages 000/ to 000/ pages 000/ and 000/ pages 000/ and 000/ 000-EN_Ver.

References Standard contactors TeSys GC Standard contactors, TeSys GC Maximum current rating category AC-a No. of poles Number of. mm modules Sold in lots of Basic reference, to be completed by adding the voltage code () Weight GC 0 A kg GC 0pp 0.0 GC 0pp 0.0 GC 0pp 0.0 GC 0pp 0.0 GC pp 0.0 GC pp 0.0 GC 00 GC 0pp 0.0 GC 0pp 0.0 GC 0pp 0.0 GC 0pp 0.0 GC pp 0.0 GC pp 0.0 GC 0pp 0.0 GC 0pp 0.0 0 GC 00pp 0.0 GC 00pp 0.0 GC 00pp 0.0 GC 0pp 0.0 GC 0pp 0.0 GC 00pp 0.0 GC 00pp 0.0 GC 0pp 0.0 GC 0pp 0.0 GC 0pp 0.0 GC pp 0.0 GC pp 0.0 GC 0pp 0.0 GC 0pp 0.0 00 GC 000pp 0.0 GC 000pp 0.0 GC 000 () Standard control circuit voltages (for other voltages, please consult your Regional Sales Offi ce): Volts 0 0/0 0 Hz J B E F M 0 Hz J B E F M 0 pages 000/ to 000/ pages 000/ and 000/ pages 000/ and 000/ 000-EN_Ver.0

References (continued) Standard contactors TeSys GC Instantaneous auxiliary contact blocks Number of contacts No. of poles Reference Weight kg GAC 0 0.0 GAC 0pp GAC 0 0.0 GAC 0 0.0 GAP p Accessories Description Coil suppression blocks comprising RC circuits For use on contactor Number Operational Sold in of modules voltage lots of V Unit reference Weight kg GAP 0.00 0 0 GAP 0.00 Ventilation / 0 GAC 0.0 / module Clips onto rail Cover plates / 0 GA C 0.00 GAC GA Cp 0 GA C 0.00 Set of sealable terminal covers (0 top parts + 0 bottom parts) or A or contacts 0 or A contacts GW 0.00 GW 0.00 GW GW p 0 or A or contacts GW 0.00 0 pages 000/ to 000/ pages 000/ and 000/ pages 000/ and 000/ 000-EN_Ver.0

Dimensions TeSys GC standard contactors Dimensions Contactors Common side view GC 0,, 0 GC 0, 0,, 0 module modules GC, 0 GC 0,, 0, 0,, 0, Common side view GC 00, 0, 00 GC 0,, 0 modules modules GC 00, 0, 00, 00 GC 0,, 0, 0,, 0 Common side view GC 000 GC 000 modules modules,,, 0 0 0 pages 000/ to 000/ pages 000/ and 000/ pages 000/ and 000/ Schemes : page 000/ 000-EN_Ver.

Dimensions (continued) schemes TeSys GC standard contactors Dimensions Auxiliary contacts Coil suppression blocks GAC 0, 0 and 0 GAP, and,,, 0,,, 0, Clip-on ventilation / module Cover plates GAC GA C GA C,, Schemes Contactors GC pp0 GC pp0 GC pp0 GC pp0 A A A A A A A A A GC pp GC pp GC pp0 GC pp0 R A A R R A R A R R R R A R R A R R R A R R R R R Auxiliary contacts GAC 0 GAC 0 GAC 0 /NO /NC /NO /NO /NO /NO 0 pages 000/ to 000/ pages 000/ and 000/ pages 000/ and 000/ Dimensions : page 000/ 000-EN_Ver.