Emerging Subsea Networks

Similar documents
from ocean to cloud SEAMLESS OADM FUNCTIONALITY FOR SUBMARINE BU

Emerging Subsea Networks

Emerging Subsea Networks

Emerging Subsea Networks

SPECTRAL HOLE BURNING EFFECTS AND SYSTEM ENGINEERING RULES FOR SYSTEM UPGRADES

SUBMARINE SYSTEM UPGRADES WITH 25 GHZ CHANNEL SPACING USING DRZ AND RZ-DPSK MODULATION FORMATS

Emerging Subsea Networks

40 Gb/s and 100 Gb/s Ultra Long Haul Submarine Systems

Dynamic gain-tilt compensation using electronic variable optical attenuators and a thin film filter spectral tilt monitor

OBSERVATION AND MITIGATION OF POWER TRANSIENTS IN 160Gbps OPTICAL BACKHAUL NETWORKS

40Gb/s Coherent DP-PSK for Submarine Applications

from ocean to cloud Copyright SubOptic2013 Page 1 of 5

EXTREMELY LONG-SPAN NON-REPEATERED SUBMARINE CABLE SYSTEMS AND RELATED TECHNOLOGIES AND EQUIPMENT

from ocean to cloud EFFICIENCY OF ROPA AMPLIFICATION FOR DIFFERENT MODULATION FORMATS IN UNREPEATERED SUBMARINE SYSTEMS

Emerging Subsea Networks

Emerging Subsea Networks

from ocean to cloud LATENCY REDUCTION VIA BYPASSING SOFT-DECISION FEC OVER SUBMARINE SYSTEMS

from ocean to cloud USING COHERENT TECHNOLOGY FOR SIMPLE, ACCURATE PERFORMANCE BUDGETING

Optical Fibre Amplifiers Continued

Emerging Subsea Networks

Emerging Subsea Networks

Pass Cisco Exam

Performance Limitations of WDM Optical Transmission System Due to Cross-Phase Modulation in Presence of Chromatic Dispersion

from ocean to cloud TCM-QPSK PROVIDES 2DB GAIN OVER BPSK IN FESTOON LINKS

EDFA TRANSIENT REDUCTION USING POWER SHAPING

Transient Control in Dynamically Reconfigured Networks with Cascaded Erbium Doped Fiber Amplifiers

Design of an Optical Submarine Network With Longer Range And Higher Bandwidth

Current Trends in Unrepeatered Systems

Module 19 : WDM Components

Power Transients in Hybrid Optical Amplifier (EDFA + DFRA) Cascades

CWDM Cisco CWDM wavelengths (nm)

EDFA WDM Optical Network using GFF

An Amplified WDM-PON Using Broadband Light Source Seeded Optical Sources and a Novel Bidirectional Reach Extender

International Journal of Computational Intelligence and Informatics, Vol. 2: No. 4, January - March Bandwidth of 13GHz

Ultra-long Span Repeaterless Transmission System Technologies

Semiconductor Optical Amplifiers (SOAs) as Power Boosters. Applications Note No. 0001

from ocean to cloud THE FUTURE IS NOW - MAXIMIZING SPECTRAL EFFICIENCY AND CAPACITY USING MODERN COHERENT TRANSPONDER TECHNIQUES

S-band gain-clamped grating-based erbiumdoped fiber amplifier by forward optical feedback technique

Emerging Subsea Networks

Optical Transport Tutorial

from ocean to cloud LOW COMPLEXITY BACK-PROPAGATION FOR UPGRADING LEGACY SUBMARINE SYSTEMS

Multi-wavelength laser generation with Bismuthbased Erbium-doped fiber

Gain-clamping techniques in two-stage double-pass L-band EDFA

Design and Manufacturing Process Management for Tera-bit/FP Class Submersible Plant

Comparative Analysis Of Different Dispersion Compensation Techniques On 40 Gbps Dwdm System

Emerging Subsea Networks

Emerging Subsea Networks

International Journal of Advanced Research in Computer Science and Software Engineering

ESTIMATION OF NOISE FIGURE USING GFF WITH HYBRID QUAD PUMPING

DESIGN ROBUSTNESS OF SUBMARINE NETWORKS USING OPTICAL ADD AND DROP MULTIPLEXING

UNREPEATERED SYSTEMS: STATE OF THE ART CAPABILITY

Improved Analysis of Hybrid Optical Amplifier in CWDM System

PERFORMANCE ANALYSIS OF 4 CHANNEL WDM_EDFA SYSTEM WITH GAIN EQUALISATION

from ocean to cloud WELCOME TO 400GB/S & 1TB/S ERA FOR HIGH SPECTRAL EFFICIENCY UNDERSEA SYSTEMS

PERFORMANCE ANALYSIS OF WDM AND EDFA IN C-BAND FOR OPTICAL COMMUNICATION SYSTEM

Exam : : Cisco Optical SONET Exam. Title. Ver :

Compensation of Dispersion in 10 Gbps WDM System by Using Fiber Bragg Grating

Performance of A Multicast DWDM Network Applied to the Yemen Universities Network using Quality Check Algorithm

VePAL UX400 Universal Test Platform

Wideband Rare-earth-doped Fiber Amplification Technologies Gain Bandwidth Expansion in the C and L bands

WDM in backbone. Péter Barta Alcatel-Lucent

Extending the Offset Frequency Range of the D2-135 Offset Phase Lock Servo by Indirect Locking

1.6 Tbps High Speed Long Reach DWDM System by incorporating Modified Duobinary Modulation Scheme

All-Optical Clock Division Using Period-one Oscillation of Optically Injected Semiconductor Laser

Optical Fiber Amplifiers. Scott Freese. Physics May 2008

Gigabit Transmission in 60-GHz-Band Using Optical Frequency Up-Conversion by Semiconductor Optical Amplifier and Photodiode Configuration

AN EFFICIENT L-BAND ERBIUM-DOPED FIBER AMPLIFIER WITH ZIRCONIA-YTTRIA-ALUMINUM CO-DOPED SILICA FIBER

RZ BASED DISPERSION COMPENSATION TECHNIQUE IN DWDM SYSTEM FOR BROADBAND SPECTRUM

OBSERVATION AND EVALUATION OF POWER TRANSIENTS IN 45 CHANNEL SSDWDM OPTICAL NETWORK

32-Channel DWDM System Design and Simulation by Using EDFA with DCF and Raman Amplifiers

Single- versus Dual-Carrier Transmission for Installed Submarine Cable Upgrades

UNREPEATERED SYSTEMS: STATE OF THE ART

A Technique to improve the Spectral efficiency by Phase shift keying modulation technique at 40 Gb/s in DWDM optical systems.

WDM. Coarse WDM. Nortel's WDM System

Simulative Analysis of 40 Gbps DWDM System Using Combination of Hybrid Modulators and Optical Filters for Suppression of Four-Wave Mixing

Optical fiber-fault surveillance for passive optical networks in S-band operation window

Optical Transport Technologies and Trends

Temporal phase mask encrypted optical steganography carried by amplified spontaneous emission noise

Transient gain dynamics in long-haul transmission systems with electronic EDFA gain control

International Journal of Advanced Research in Computer Science and Software Engineering

Emerging Subsea Networks

Implementation and analysis of 2 Tbps MDRZ DWDM system at ultra narrow channel spacing

Emerging Subsea Networks

Prabhjeet Singh a, Narwant Singh b, Amandeep Singh c

Multiwavelength optical fibre source

REDUCTION OF CROSSTALK IN WAVELENGTH DIVISION MULTIPLEXED FIBER OPTIC COMMUNICATION SYSTEMS

30 Gbaud Opto-Electronics and Raman Technologies for New Subsea Optical Communications

RZ-DPSK 10GB/S SLTE AND ITS TRANSMISSION PERFORMANCE ASSESSMENTFOR APPLICATION TO TRANS-PACIFIC SUBMARINE CABLE SYSTEMS

Optimized Flattened Gain Spectrum in C Band WDM using Automatic Gain Control in Bi-Directionally Pumped EDFA

The Reduction of FWM effects using Duobinary Modulation in a Two-Channel D-WDM System

Practical Aspects of Raman Amplifier

Optimized Dispersion Compensation with Post Fiber Bragg Grating in WDM Optical Network

Performance Analysis of Gb/s DWDM Metropolitan Area Network using SMF-28 and MetroCor Optical Fibres

Construction Technology for Use in Repeatered Transoceanic Optical Submarine Cable Systems

Optical Fiber Technology

Balanced hybrid and Raman and EDFA Configuration for Reduction in Span Length

RXT-1200 Modular Test Platform

Suppression of Stimulated Brillouin Scattering

Full-duplex bidirectional transmission of 10-Gb/s millimeter-wave QPSK signal in E-band optical wireless link

Optoelectronic Oscillator Topologies based on Resonant Tunneling Diode Fiber Optic Links

Transcription:

A NEW CABLE FAILURE QUICK ISOLATION TECHNIQUE OF OADM BRANCHING UNIT IN SUBMARINE NETWORKS Hongbo Sun, Likun Zhang, Xin Wang, Wendou Zhang, Liping Ma (Huawei Marine Networks Co., LTD) Email: sunhongbo@huaweimarine.com Huawei Marine Networks Co., LTD / HuaWei Bld., No.3 Xinxi Rd., Shang-Di Information Industry Base, Hai-Dian District, Beijing P.R. China Abstract: When cable faults occur in an undersea fibre communication system with an OADM function, performance of survival traffic maybe degraded or even interrupted. A new fault isolation scheme that induces zero penalty on survival traffic is discussed in this paper. Experiments detailed below shows that this scheme is safe to a submarine cable line with no risk of optical power transient during fault isolation operation and has no impact on transmission. 1. INTRODUCTION A branching unit with OADM function is attractive to submarine networks carriers due to the benefits of flexible distribution of transmission connectivity between multiple landing stations, namely: cost sharing amplifier bandwidth, decrease transmission latency, simplified network management and improve traffic availability [1, 2]. For a submarine cable system employing an OADM BU, when cable faults occur in the trunk or spur cable line, some channels will be lost in the surviving line. As repeaters in a submarine system always work with constant optical output power, the surviving channels will share the overall launch power of the repeaters. This cause the power level of the surviving channels to increase dramatically and the nonlinear effect will be too strong to maintain their performance, causing this traffic to deteriorate or even shut down [1, 3]. Various fault isolation or recovery solutions for submarine cable systems with an OADM BU have been introduced to maintain survival traffic during the time waiting for repair [1-6]. A new fault isolation scheme is discussed here. The scheme has the advantage of high reliability, compact and low power consumption. Experimental results have demonstrated no impact on survival traffic in trunk or branch faults scenarios. An automatic mode which can provide quick fault isolation is also discussed. Further experimental work detailed here will also verify whether the schemes based on optical switching will introduce power transients to the surviving line. 2. SCHEME DESCRIPTION Fig. 1 shows the typical optical route of submarine cable system with OADM BU. DWDM signals enter the input port of the BU, and are split into two paths by the OADM. In the express path, the drop bandwidth is blocked, and the express signals couple with the add signals to the output port of the BU. In the drop path, the dummy channels are looped from the add path to the drop path of the OADM via the internal loop path and combined with the dropped signals. The light path in the opposite direction is identical. Copyright SubOptic2016 Page 1 of 6

Trunk Express Drop Input Express OADM OS Trunk Express Add Output Dummy Dummy Drop Drop Add Fig. 1: A typical optical routing of an OADM BU Dummy Add A new fault isolation scheme for cable faults in a submarine cable system with an OADM function is proposed. Fig. 2 shows the working principle of the scheme for trunk cable faults. When the trunk cable faults, the traffic channels from the trunk line will be lost, then nothing but the added channels will be transmitted in trunk line. To compensate for the lost channel power, the OADM BU will reroute the dummy channels from the branch station to the trunk line, and the power of the surviving traffic channels will be suppressed to its normal level. Fig. 3: The optical route of an OADM BU with spur cable fault isolation The new scheme can be implemented by combining a high reliability, miniature optical switch with an OADM module as shown in Fig. 4, with the added advantage of low additional power consumption. The scheme has a symmetrical structure and so implementation in the opposite transmission direction is the same. Fig. 4: Implementation of new fault isolation scheme Fig. 2: The optical routing of an OADM BU with trunk cable fault isolation When the spur cable faults, the OADM BU will reroute the drop channels back to trunk cable line to compensate the lost channel power as shown in Fig. 3. By monitoring input power at input port of the OADM BU, the fault isolation scheme can work in an automatic mode. In automatic mode, the OADM BU reroutes the light path to the presupposed status according to the detected cable fault pattern, and restores the traffic carried on the surviving channels quickly. Should the fault cable be repaired, the light path will restore to the normal operation status automatically. For cable faults in trunk line, by monitoring the input power, any power loss, can be detected triggering the fault Copyright SubOptic2016 Page 2 of 6

isolation operation which will reroute the internal optical path as shown in Fig. 2. The operation for spur line faults works in like manner as shown in Fig. 3 when power loss at spur input port detected. 3. EXPERIMENTAL DEMONSTRATION AND TEST RESULTS In order to test and verify the new scheme and automatic fault isolation function, a bidirectional test bed with one fibre pair OADM BU was constructed as shown in Fig. 5. The test bed includes stations A, B and C deployed with SLTE. The OADM BU divides the system into 3 segments of S1 (1000km), S2 (1100km) and S3 (1000km). Each segment consists of several 66.7km spans of Corning Vascade EX2000 fibre. The launch power of the repeater is +16dBm, with an average noise figure of 4.9dB, operating in the amplified band width range from 1530nm to 1564nm. The SLTE has a total of 40 channels spaced at 100GHz. There are 8 add/drop channels with bandwidth ranges from 1543.73nm to 1549.32nm, and the NMS is installed in each terminal station. Several cable faults scenarios are shown in Fig. 5, the label cut 1, cut 2 and cut 3 denote the different locations. Cut2 S1 Cut1 Cut3 DROP OADM-BU OADM ADD ADD OADM Station C Fig. 5: The experimental demonstration set-up The spectrum and transmission performance of the express channels and add/drop channels are tested at station B and form the baseline data for normal operation as shown in Fig. 6. DROP S3 S2 OSNR(dB) Optical power(dbm) 27 26 25 24 23 22 21 20 10.5 1525 1530 1535 1540 1545 1550 1555 1560 1565-25 -30-35 -40-45 -50-55 OSNR Q Wavelength(nm) Normal Operation -60 1525 1530 1535 1540 1545 1550 1555 1560 1565 Wavelength(nm) Fig. 6: Spectrum and transmission performance of express and add/drop channels at station B w/o cable cut When the cable fault occurs in cut 1 in Fig. 5, the spectrum of the surviving channels is tested at station B as shown in red within Fig. 7. The optical power of each survival channels is about 5~8 db higher than the original power in Fig. 6, and the traffics are disrupted by nonlinear impairments without fault isolation. When the OADM BU has finished the fault isolation operation after receiving a command from the NMS, the received spectrum at station B, including the survival and rerouted dummy channels is as shown in blue in Fig. 7. This indicates the survival channels return to normal power after fault isolation. The automatic fault isolation function has therefore been verified in this scenario. The results further indicate that the traffic could recover within one second. When a cable cut repair is simulated the optical circuit also restores to normal operation status quickly in automatic fault isolation mode. 13 12.5 12 11.5 11 Q(dB) Copyright SubOptic2016 Page 3 of 6

power in the line to guarantee the performance of the survival traffic. If the transmission distance is extended then fault isolation will be necessary. When fault isolation finished, the performance recover same with the results showed in Fig. 7 (b) and (c). (a) (a) (b) (b) (c) Fig. 7: (a)spectrum (b)onsr (c)q value at station B w/wo fault isolation under cable cut 1 scenario When a cable fault occurs in cut 2 in Fig. 5, the ASE output from the repeater adjacent to the BU will partial compensate the lost channel power provided the power supply of the repeater maintains. The received spectrum is tested at station B as shown in green within Fig. 8 (a). The transmission performance tested at station B shows that the degradation of the Q factor is about 2~3 db, and shows that ASE from the adjacent repeater cannot entirely compensate for the lost channel (c) Fig. 8: (a)spectrum (b)onsr (c)q value at station B w/wo cable fault at spans non-adjacent to OADM BU For the scenario that a cable fault occurs in cut 3 in Fig. 5, the fault isolation operation is similar with that of a trunk fault. Experiments have clearly shown that if the add/drop channels are a small portion Copyright SubOptic2016 Page 4 of 6

of the full DWDM bandwidth, there is little impact on the optical transmission performance of the express channels, and no fault isolation action will be necessary in this occurrence [4]. 4. ANALYSIS AND TEST OF OPTICAL POWER TRANSIENT When a cable fault occurs, some channel power will be lost in the line. When the OADM BU finishes the fault isolation, the lost channel power will be compensated instantly. There is a risk that such a fault isolation operation may cause an optical power transient resulting in potential damage in the fibre line [7, 8]. To establish the level of risk, the test setup shown in Fig. 9 was used. The arrangement shown can simulate the adding of lost channels during the fault isolation operation in a cascaded EDFA chain. Using a dummy light source and optical switch to simulate the channel lost/add process, and combining this with a PIN diode, an amplification circuit and an oscilloscope it is was possible to detect any optical power transient in line. Fig. 9: The experimental setup for detection of optical power transient during fault isolation operation To estimate the most severe situation, the n which denote the initial channel number is set to 1 to simulate only 1 channel left in surviving line when the cable faults occurs. The outputs at the first, second and fifth EDFA were measured during the optical path switching procedure. The strongest transient was detected at the output of the first EDFA, proving that the transient will not be amplified in the cascaded EDFAs. Fig. 10 shows the oscilloscope response measured at the first EDFA. By calculating the voltage level, the maximum increase in the optical power peak was found to be 1.39dB higher than nominal output during the optical switch operation; therefore the optical transient is low enough not to induce damage in the line. The reason for this is considered to be the 0.5 microseconds switch speed of the optical switch. Fig. 10: The optical power transient measured in fault isolation simulation 5. CONCLUSIONS The new cable fault isolation scheme of the OADM BU provides the advantages of high reliability, compact and low power consumption. The results of transmission experiments clearly show that such an OADM fault isolation system can be achieved without penalty on survival traffic. By monitoring traffic power at the input port, the OADM BU can quickly identify and isolate faults without the need for manual operation at terminal stations in some scenarios. Testing also demonstrates that an optical switch will not introduce an optical power transient sufficient enough to cause damage to the submarine cable line. Copyright SubOptic2016 Page 5 of 6

6. REFERENCES [1] Takanori Inoue et al., Meshed Submarine cable Network with OADM Technology, SubOptic 2010, Yokohama [2] Daniel Welt, The Case for OADM Undersea Branching Units with Bandwidth Re-use, SubOptic 2010 [3] A.V.Turukhin et al., Faults and Recovery Methods in Regional Undersea OADM Networks, ECOC 2009 [4] Ekaterina A. Golovchenko, et al., Trans-Oceanic OADM Networks: Faults and Recovery, SubOptic 2010 [5] A. Akhtar et al., First Field Demonstration of Fault Resilience in a Regional Undersea OADM Network, OFC 2012 [6] Wendou Zhang, et al., Protecting survival traffics under cable-failure case of OADM topology, SubOptic 2013. [7] Miroslav Karasek et al., Channel Addition/Removal Response in Cascades of Strongly Inverted Erbium-Doped Fiber Amplifiers, JOURNAL OF LIGHTWAVE TECHNOLOGY, VOL. 16, NO. 12, DECEMBER 1998 [8] A.K.Srivastava et al, EDFA transient response to channel loss in WDM transmission System, IEEE PHOTONICS TECHNOLOGY LETTERS. VOL. 9. NO. 3, MARCH 1997 Copyright SubOptic2016 Page 6 of 6