EFFECTS OF ACCELEROMETER MOUNTING METHODS ON QUALITY OF MEASURED FRF S

Similar documents
Good Modal Practices

Vibration Fundamentals Training System

Response spectrum Time history Power Spectral Density, PSD

2 Study of an embarked vibro-impact system: experimental analysis

Introduction to LIVM Accelerometers

Introduction To Impulse Hammers

AN ADAPTIVE VIBRATION ABSORBER

(i) Sine sweep (ii) Sine beat (iii) Time history (iv) Continuous sine

AN5E Application Note

sin(wt) y(t) Exciter Vibrating armature ENME599 1

Do all accelerometers behave the same? Meggitt-Endevco, Anthony Chu

SOLVING VIBRATIONAL RESONANCE ON A LARGE SLENDER BOAT USING A TUNED MASS DAMPER. A.W. Vredeveldt, TNO, The Netherlands

Section 7 - Measurement of Transient Pressure Pulses

Modal Parameter Estimation Using Acoustic Modal Analysis

CHOOSING THE RIGHT TYPE OF ACCELEROMETER

CONTENTS. Cambridge University Press Vibration of Mechanical Systems Alok Sinha Table of Contents More information

System Inputs, Physical Modeling, and Time & Frequency Domains

PVA Sensor Specifications

Experimental investigation of crack in aluminum cantilever beam using vibration monitoring technique

Resonant Frequency Analysis of the Diaphragm in an Automotive Electric Horn

Models Z7, Z11, Z602WA and Z820WA Impedance head operating guide

Model Correlation of Dynamic Non-linear Bearing Behavior in a Generator

FREE AND FORCED VIBRATION EXPERIMENTS ON A CROSSBEAM SYSTEM

26 Endevco Isotron accelerometers

SDOF System: Obtaining the Frequency Response Function

Anthony Chu. Basic Accelerometer types There are two classes of accelerometer in general: AC-response DC-response

BASICS OF MODAL TESTING AND ANALYSIS

Accelerometer Sensors

A study of Vibration Analysis for Gearbox Casing Using Finite Element Analysis

Modal damping identification of a gyroscopic rotor in active magnetic bearings

Development of a Package for a Triaxial High-G Accelerometer Optimized for High Signal Fidelity

Solution of Pipeline Vibration Problems By New Field-Measurement Technique

ME scope Application Note 02 Waveform Integration & Differentiation

Dytran Instruments, Inc. 1

Model CAACS Commercial Automated Accelerometer Calibration System

LORENTZ FORCE DETUNING ANALYSIS OF THE SPALLATION NEUTRON SOURCE (SNS) ACCELERATING CAVITIES *

BLADE AND SHAFT CRACK DETECTION USING TORSIONAL VIBRATION MEASUREMENTS PART 1: FEASIBILITY STUDIES

ELASTIC STRUCTURES WITH TUNED LIQUID COLUMN DAMPERS

DYNAMIC CHARACTERIZATION OF ORIFICE TYPE AEROSTATIC BEARING

Investigate and Optimize Your Structures with Kistler's Modal Portfolio

Optimize Stator Endwinding Vibration Monitoring with Impact Testing

The units of vibration depend on the vibrational parameter, as follows:

3.0 Apparatus. 3.1 Excitation System

Acceleration Sensor AS - 022

ANALYSIS OF 3RD OCTAVE BAND GROUND MOTIONS TRANSMISSION IN SYNCHROTRON RADIATION FACILITY SOLARIS Daniel Ziemianski, Marek Kozien

GENERAL PURPOSE PIEZOELECTRIC LOAD CELL

The ENDEVCO high-g shock triaxial accelerometer: A smaller, more cost-effective solution to making triaxial measurements. Endevco technical paper 334

PRODUCT DATA. Piezoelectric Accelerometer Miniature Triaxial DeltaTron Accelerometers Types 4524, 4524 B

FLUTTER CONTROL OF WIND TUNNEL MODEL USING A SINGLE ELEMENT OF PIEZO-CERAMIC ACTUATOR

Impact sound insulation: Transient power input from the rubber ball on locally reacting mass-spring systems

Model CAACS Commercial Automated Accelerometer Calibration System

DETERMINATION OF CUTTING FORCES USING A FLEXURE-BASED DYNAMOMETER: DECONVOLUTION OF STRUCTURAL DYNAMICS USING THE FREQUENCY RESPONSE FUNCTION

Development of Shock Acceleration Calibration Machine in NMIJ

Laboratory Experiment #2 Frequency Response Measurements

MODEL MODIFICATION OF WIRA CENTER MEMBER BAR

EXPERIMENTAL ANALYSIS OF BOLT LOOSENING DYNAMICS CHARACTERISTIC IN A BEAM BY IMPACT TESTING

PRODUCT DATA. Piezoelectric Accelerometer Miniature Triaxial Charge Accelerometers Types 4326-A and 4326-A-001

MATHEMATICAL MODEL VALIDATION

Part 2: Second order systems: cantilever response

Hybrid Vibration Energy Harvester Based On Piezoelectric and Electromagnetic Transduction Mechanism

Developer Techniques Sessions

Dynamic Vibration Absorber

Correction for Synchronization Errors in Dynamic Measurements

IPC-TM-650 TEST METHODS MANUAL

Aero Support Ltd, 70 Weydon Hill Road, Farnham, Surrey, GU9 8NY, U.K.

Piezoelectric accelerometer design. Piezoelectric transducers Quartz and piezoceramics Mechanical design Charge amplification Design trade-offs

Dynamics of Mobile Toroidal Transformer Cores

CHAPTER 6 INTRODUCTION TO SYSTEM IDENTIFICATION

Conventional geophone topologies and their intrinsic physical limitations, determined

Piezoelectric multilayer triaxial accelerometer

Chapter 30: Principles of Active Vibration Control: Piezoelectric Accelerometers

Mounting Instructions

Modal Excitation. D. L. Brown University of Cincinnati Structural Dynamics Research Laboratory. M. A. Peres The Modal Shop, Inc Cincinnati, OH

IOMAC' May Guimarães - Portugal

FATIGUE CRACK CHARACTERIZATION IN CONDUCTING SHEETS BY NON

A New Solution for Shock and Vibration Calibration of Accelerometers

A detailed experimental modal analysis of a clamped circular plate

HOW HIGH IN FREQUENCY ARE ACCELEROMETER MEASUREMENTS MEANINGFUL

Structure-borne Vibration Analysis of Acoustic Enclosure of Compressor

Kistler portable triaxial Force Plate

vibrati vibration solutions by sensor type Measurement Specialties brings more than twenty years of

Fundamentals of Structural Dynamics

Bridge Vibrations Excited Through Vibro-Compaction of Bituminous Deck Pavement

Texas Components - Data Sheet. The TX53G1 is an extremely rugged, low distortion, wide dynamic range sensor. suspending Fluid.

A novel procedure for evaluating the rotational stiffness of traditional timber joints in Taiwan

Identification of Delamination Damages in Concrete Structures Using Impact Response of Delaminated Concrete Section

Experimental Investigation of Crack Detection in Cantilever Beam Using Natural Frequency as Basic Criterion

the pilot valve effect of

Sensors for Vibration, Acceleration, and Shock Measurement. Product Catalog

Modal Parameter Identification of A Continuous Beam Bridge by Using Grouped Response Measurements

Principles of Vibration Measurement and Analysis. Dr. Colin Novak, P.Eng July 29, 2015

Telling. The tailpiece of the violin family is an

BASICS OF STRUCTURAL VIBRATION TESTING AND ANALYSIS

Fabrication & Testing of composite tractor trolley chassis Mr. Ashish Azade 1 Mr.Tushar B.Shinde 2

NINTH INTERNATIONAL CONGRESS ON SOUND AND VIBRATION, ICSV9 ACTIVE VIBRATION ISOLATION OF DIESEL ENGINES IN SHIPS

Accelerometers. Providing quick, accurate and reliable motion data

Mechanical vibration Rotor balancing. Part 31: Susceptibility and sensitivity of machines to unbalance

Enhanced Resonant Inspection Using Component Weight Compensation. Richard W. Bono and Gail R. Stultz The Modal Shop, Inc. Cincinnati, OH 45241

Installation of vibration sensors

VIBRATIONAL TESTING OF A FULL-SCALE PILE GROUP IN SOFT CLAY

Transcription:

The 21 st International Congress on Sound and Vibration 13-17 July, 2014, Beijing/China EFFECTS OF ACCELEROMETER MOUNTING METHODS ON QUALITY OF MEASURED FRF S Shokrollahi Saeed, Adel Farhad Space Research Center, Tehran, Iran e-mail: shokrollahi@isav.ir Modal testing is a vibration testing method that can be used to achieve the intrinsic properties of structures such as natural frequencies, damping coefficients and mode shapes. Accelerometers are one of the vital equipment s in modal testing. Selection of the appropriate method for connecting these sensors to structures plays an important role in achieving frequency response functions with minimum noise. Different methods exist for installation of accelerometers in structures. This paper identifies and clarifies issues regarding mounting of accelerometers. In this study, accelerometers are mounted with three different procedures (magnet, wax and stud) on a steel beam and results of modal testing have been compared in all three conditions. The results of this study show significant effects of the sensor installation methods on the response of the structure in both time and frequency domains. Based on these measured results and predictions from mathematical model, it is recommended to mounting accelerometers with studs as possible and the next priority is the use of wax (or instant adhesive) and magnet. 1. Introduction The method of mounting contact-type vibration transducers (such as accelerometers) can have a significant influence on the sensed vibration signals. The accelerometer mounting method will almost always have some influence on the frequency response. In some cases, the influence is negligible; in other cases, the mounting method can have a significant influence. Choosing the optimum mounting arrangement will significantly improve the accuracy. For an accelerometer to generate accurate and useful data, it must be properly coupled to the system under investigation. This means that the mounting must be rigid over the frequency range of interest to avoid distortion of the frequency response function. Figure 1 illustrates typical reasons for coupling errors. For best performance, particularly at high frequencies, the accelerometer base and the test object should have clean, flat, smooth and unscratched surfaces. The transmission of higher frequencies can be improved by a thin layer of silicon grease at the coupling surface. Figure 1. Typical reasons of coupling errors 1 ICSV21, Beijing, China, 13-17 July 2014 1

Since the natural frequency of an accelerometer, when mounted, is dependent on the stiffness of the coupling method (see Figure 2), choosing the correct method very important. Figure 2. Frequency response characteristics of different mounting methods 2 2. Mechanics of mounting The ability to couple motion, (in the form of vibration), to the accelerometer with high fidelity, is highly dependent upon the method of mounting the instrument to the test surface. For best accuracy, it is important that the mounting surface of the accelerometer be tightly coupled to the test surface to ensure the duplication of motion and avoiding relative motion effects, especially at higher frequencies. Since various mounting methods may adversely affect accuracy, it is important to understand the mechanics of mounting the accelerometer for best results. If we think of the piezoelectric material as having finite stiffness and damping which resist the deformation (strain) imposed by the seismic mass, then we can represent the accelerometer as shown in Figure 3a. This emphasizes that the accelerometer is a dynamic system itself with its own natural frequency that could affect the measurement result. For this reason, accelerometers are designed to have high natural frequencies. So a piezoelectric accelerometer can be regarded as a mechanical low pass with resonance peak. It shows the typical resonance behaviour and defines the upper frequency limit of an accelerometer. In order to achieve a wider operating frequency range the resonance frequency must be increased. This is usually done by reducing the seismic mass. However, the lower the seismic mass, the lower the sensitivity. The illustration in Figure 3a, is correct if the sensor is connected rigidly on the structure. In reality, this is not to be the case. An accelerometer has to be mounted non-rigidly on a structure for measurement. If considered as a rigid mass block, the accelerometer and its mount can be modelled as an SDOF system as shown in Figure 3b. (a) (b) Figure 3. The accelerometer and its mounting as a spring mass damper system (a). rigid connection, (b). non-rigid connection ICSV21, Beijing, China, 13-17 July 2014 2

The accuracy of the acceleration measurement depends largely on the mounting which is modelled by a spring and a damper. The accelerometer is of course more than just a mass block and it has its own natural frequency. This frequency is usually much higher than the frequency of the SDOF system in Figure 3b. The best accuracy would arise if the mounting were rigid. The flexibility of the mounting means that the characteristics of the accelerometer are compromised somewhat. Because of it, acceleration from the structure may be different from the experienced by the accelerometer. However, if the natural frequency of this SDOF system is five times or more of the frequency of the acceleration signal from the measured structure, then there is effectively no magnitude and phase distortion 3. According to last paragraph, during the mounting, other springs are inadvertently interposed between mating surfaces creating secondary spring-mass systems with lower natural frequencies than that of the accelerometer itself. So one can model the whole system as a two DOF system as shown in Figure 4. There are now two spring-mass systems and both will affect frequency response. 3. Experiment (a) Figure 4. A two DOF model of an accelerometer and its mounting (b) (a). schematic model, (b). mass-spring-damper model 3.1 Case study A steel beam is used to investigate the effects of different mounting methods on the quality of the structural response in time and frequency domains. The beam has cross section of b h = 40 12 mm 2 and a length of L = 500 mm (Figure 5). Various modes of bending have been studied. In table 1, the first two natural frequencies of the beam are calculated using the methods of numerical solution and the exact solution. Figure 5. Geometric dimensions and physical properties of beam Table 1. Natural frequencies of beam using numerical and analytical methods Solution method Natural Freq. # 1 (Hz) Natural Freq. # 2 (Hz) Numerical 248.59 683.51 Exact 249.05 686.51 ICSV21, Beijing, China, 13-17 July 2014 3

3.2 Accelerometer mounting methods The key question is which mounting method is most suited for the intended purpose. The recommended mounting method is that used for calibration 4. In this study, three different methods that have been considered for mounting accelerometers on the structure are magnet, wax, and stud. These methods are shown in Figure 6 and Figure 7. It is recommended that for using stud, the threaded depth should be at least 6.25 mm 5. (a) (b) Figure 6. Installing accelerometers a. magnetic property, b. wax Figure 7. Installing accelerometers using stud 3.3 Modal testing Since a frequency range of 800 Hz is considered for modal testing, all three methods of installation (stud, magnet and wax) are applicable for this study. A modal hammer is used to excite the Structure with free - free support condition as shown in Figure 8. For better excitation of the first two modes, a plastic hammer head is used. Six number of impacts were used to excite the structure at certain points of interest and the responses were averaged to obtain a used in signal processing. Duration for data collection after each impact is 2.5 seconds and Data acquisition was performed using YE7600 software. Signal processing performed using N-Modal software. Positions of accelerometers on the beam are shown in Figure 9. As it can be seen, the sensor cables are restrained by tape on the beam. Oscillation of these wires in connecting point to the sensor is one of the sources of error in modal testing, so be sure they're firm and their motion constrained very well. Modal tests have been performed on typical IEPE Accelerometers: Model CA- YD-1181 from TMC Solution Company weighs 10 grams and has a flat frequency response of 1-10 khz when stud mounted (Figure 10). ICSV21, Beijing, China, 13-17 July 2014 4

Figure 8. Structural stimulation with modal hammer Figure 9. A view of the test structure and arrangement of sensors Figure 10. Frequency response characteristics of accelerometer used in this study 4. Structural response in time domain Structural response to applied excitations in all three cases of mounting is presented in Figure 11 to Figure 13. The prominent aspect in these figures is the presence of different response damping rate in three situations. In installation with stud, relatively rigid connection is created compared with the other two methods. So in this case, the connection stiffness (k) is greater than the other two methods and relative motion between vibrating structure and accelerometers is much less. In this case, the outputs of accelerometers are almost pure response of the structure. But in other cases, especially in the magnet mounting method the damping rate of structural response is lower due to relative motion effect between the structure and the accelerometers. ICSV21, Beijing, China, 13-17 July 2014 5

Figure 11. Structural response in time domain (magnet) Figure 12. Structural response in time domain (wax) Figure 13. Structural response in time domain (stud) 5. Structural response in frequency domain With plotting the response of the structure in frequency domain, important information is extractable about the dynamic characteristics of the structure. A peak point in this diagram demonstrates the resonant frequencies of the structure. Around these points, structural damping is dominant and simple procedures such as Peak-Picking can be used to obtain the initial estimate of damping ratios. Modal Indication Function (MIF) for the three cases is shown in Figure 14 to Figure 16. Low noise and increasing the quality of the MIF Graph are clearly visible in Figure 16. The stud mount method yields the best results because when the instrument is installed in this fashion, the accelerometer and the test surface are essentially fused together by virtue of the high clamping force of the stud 6, ensuring the exact duplication of motion of both bodies at all frequencies. ICSV21, Beijing, China, 13-17 July 2014 6

Figure 14. Structural response in frequency domain (magnet) Figure 15. Structural response in frequency domain (wax) Figure 16. Structural response in frequency domain (stud) In table 2, the values of the first and second resonance frequencies of the structures using any of accelerometer installation methods are presented. In table 1, the frequency values from analytical methods (exact solution) and numerical methods (finite element analysis with a converged mesh) are shown for comparison. Mounting method Magnet Wax Stud Table 2. Experimental resonance frequencies of beam Resonance frequency # 1 (Hz) 246.09 248.05 247.07 Resonance frequency # 2 (Hz) 673.34 666.02 669.92 ICSV21, Beijing, China, 13-17 July 2014 7

6. Conclusion The results of this research indicate that different methods for accelerometer mounting, affect the accuracy of the FRF data in an experimental modal analysis. To achieve the greatest accuracy in modal testing especially at higher frequencies, connection of the accelerometers to structure must to be sturdy and rigid to minimize relative motion. The stud type mounting is for this reason prevails. In this case, the accelerometer and structure surfaces are paired perfectly with each other, especially if you use a thin layer of grease between the surfaces. Mounting wax is very convenient to use but it should only be used when no other alternatives are feasible. The low modulus (rigidity) of wax makes the results unreliable at higher frequencies. Magnetic mounting adapters are used to attach accelerometers to ferromagnetic surfaces. In general, magnetic adapters should be used with caution and rarely trusted at frequencies above 1 khz. REFERENCES 1 2 3 4 5 6 Wagner, J., Burgemeister, J., (2012). Piezoelectric Accelerometers: Theory and Application, MMF Technical paper, 6 th revised edition. [Online] available : http://www.mmf.de/manual/transducermane.pdf Ewins, D. J., Modal Testing: Theory, Practice and Application, Second Edition, Research Studies Press Ltd, England, (2000). He, J., Fu, Zh., Modal Analysis, Butterworth-Heinmann, Woburn, MA 01801-2041, (2001). Mathews, J., Guide to accelerometer installation, Endevo Technical Paper TP 319, Endevco Corporation, USA, (2001). Anon., Structure-borne Vibratory Acceleration Measurements and Acceptance Criteria of Shipboard Equipment, MIL-STD-740-2, (1986). Anon., Accelerometer Mounting Considerations, Dytran Technical Paper, DYTRAN Instruments Inc, [Online] available : http://www.dytran.com/assets/pdf/accelerometermountingconsiderations.pdf ICSV21, Beijing, China, 13-17 July 2014 8