TRANSDUCER IN-LINE AMPLIFIER

Similar documents
TRANSDUCER IN-LINE AMPLIFIER

MODEL UBP-10 UNIVERSAL IN-LINE TRANSDUCER AMPLIFIER BI-POLAR SUPPLY, 0-10 VOLT OUTPUT

SENSOTEC UNIVERSAL INLINE TRANSDUCER AMPLIFIER BIPOLAR VOLTAGE MODEL. $!}~ f?(' 7. ()ept 1200 CHESAPEAKE AVE" COLUMBUS OHIO (614)

Model TS. Transducer Simulator User s Guide. Sensotec Sensors

SENSOTEC, INC Arlingate Lane Columbus, Ohio Phone (614) Facsimile (614) Toll Free Free (800)

TECHNICAL MANUAL. SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100

Series APD4059. For Load Cells/Pressure Transducer Transmitters. Field Rangeable, with Calibration Resistor. Standard Features.

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

TECHNICAL MANUAL. SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100

Instruction Manual. HB Series Mini Level Sensor

AMP-13 OPERATOR S MANUAL

PARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET

742A Series Resistance Standards

BC145 SIGNAL ISOLATOR BOARD

Model 9305 Fast Preamplifier Operating and Service Manual

Preliminary Data Sheet!

Model A-5. Mid Range Wet/Wet Differential Pressure Transducer. A-5, Datenblatt Seite 1 DESCRIPTION FEATURES

201AP Charge Amplifier User Manual

SSR V-12C. Industrial Switching Applications: Hellroaring Technologies, inc. P.O. Box 1521, Polson, Montana 59860

MINCO PRODUCTS, INC Commerce Lane, Minneapolis, Minnesota U.S.A. Telephone: (763) FAX: (763)

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

Copyright 2014 by Minarik Drives

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

SSR-150xxx-40VL-12P-xC-xxxCS

Ricochet Alphasonic Level Transmitter Model LA15/20 Owner s Manual

SSR VL-12P-xC-NCS

MODEL 3810/2 Line Impedance Stabilization Network

TSSP-1 (Stainless Steel Thermistor Probe) Manual Rev A

LED Series Sealed High-Intensity Area Lights

LINCO MEASUREMENT MODEL CP-2B MASTER METER PROVER COUNTER INSTRUCTION MANUAL

HELLROARING TECHNOLOGIES, INC. P.O. BOX 1521 POLSON, MT

Model A. DIN Rail Strain Gage Conditioner. Installation and Operating Manual

DA6002D-DA10004D. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

Model 863 Quad Timing Filter Amplifier Operating and Service Manual

P.O. BOX 1521 POLSON, MT SSR V-12C

Model 113 Scintillation Preamplifier Operating and Service Manual

RHS SERIES RH Set Point Controller/Probe

EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure

DA560D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

JMAA-1800HR15. Installation and Operation Instructions. 180w Performance Series Amplifier Kit For Harley RoadGlide/ Ultra

VOLUME CONTROL CONNECTION TERMINAL

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual

2012 MFJ ENTERPRISES, INC.

ELECTRIC FIELD PROBE ANTENNA MODEL PEF-10A. 20 Hz 1 MHz

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

AMP-12 OPERATOR S MANUAL

DA604D DA954D DA501D DA801D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

Global Water Instrumentation, Inc.

Model 9302 Amplifier-Discriminator Operating and Service Manual

Broadband Current Probe Series Operation Manual

COMBILOG ANTENNA MODEL AC MHz. rev: 0202

SX204. Headphone Amplifier. Symetrix. Owner s Manual

Current Probe Fixture Instruction Manual

CT-2 and CT-3 Channel Taggers OPERATION MANUAL

MFJ ENTERPRISES, INC.

XPR522 XPR540. XPR SERIES INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

Signal Isolation Module. Instruction Manual SIM

Wilcom MODEL T336B CIRCUIT TEST SET. Operating Instructions

PCO-7114 Laser Diode Driver Module Operation Manual

E7000, E7500, and E ma Analog Transmitters

TT881 Explosion-Proof Temperature Assembly Installation and Operating Instructions

Model 439 Digital Current Integrator Operating Manual

Worldwide Manufacturer of Gas Detection Solutions. Transmitter EC 23. Operation Manual

Model 41E. Precision Low Profile Load Cell DESCRIPTION FEATURES

DIN Thermocouple Conditioner MODEL 5M14(V)

Table of Contents. Safety Notices

CRD 410 MANUAL FITTING INSERTER

USER S MANUAL PROCESS CONTROL MODULE PCM3

EA3012 TRANSCONDUCTANCE AMPLIFIER OPERATION MANUAL

INSTRUCTION MANUAL MODEL 2455T SUBCARRIER MODULATOR

TIA-952 Optical/Electrical Converter. Operating Instructions

XIA3145 INSTALLATION/OWNER S MANUAL 2/1-Channel Mobile Power Amplifier

F Series SINGLE-PHASE DIGITAL SWITCHBOARD MONITORS FVA, FVD, FAA, FAD, FF, FT MODELS

JMAA-3600HR16-UL. Installation and Operation Instructions. Performance Series 360w RMS 4-Channel Amplifier Kit For Harley RoadGlide Ultra

Model RGH. Rod End In-line Compression/Tension Load Cell DESCRIPTION FEATURES

MANLEY LABORATORIES, INC. OWNER'S MANUAL MANLEY 50 WATT MONOBLOCK AMPLIFIER

ASSEMBLY INSTRUCTIONS

Glass Electrode Meter

41P Portable Calibrator User Manual

Model 427A Delay Amplifier Operating and Service Manual

305 Stimulus Isolator. Description

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR

Digital Lighting Systems, Inc.

SERIES M MIXER MASTS

Radio Remote(s) (Installation Manual)

DATASHEET AND OPERATING GUIDE TCS Series Thermistors

Users Manual. Non-Contact Displacement Measuring System

XPA2100 XPA4100 XPA6100. XPA SERIES INSTALLATION/OWNER S MANUAL Mobile Power Amplifiers

HT2 Humidity Transmitter HT2 Humidity and Temperature Transmitter Installation and Operating Instructions

2013 MFJ ENTERPRISES, INC.

Model Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

Global Water Instrumentation, Inc.

MBC Bipolar Microstep Driver. User s Guide. 910 East Orangefair Lane, Anaheim, CA

User s Guide FLSC-45/45B. Paddlewheel Signal Conditioner. Shop online at omega.com

Ricochet Alphasonic Level Transmitter Model LA15 Owner s Manual

Performance Series 360w 4-CH Amplifier Kit For Harley Street Glide with Lower/Rear Speakers JMAA-3600HC14-SG

TIA-527 Balanced Optical/Electrical Converter. Operating Instructions

2007 MFJ ENTERPRISES, INC.

Programmable K-Factor Scaler B and Programming Software Kit B

Models Tension/Compression Pancake Load Cell Model 3174 with tension base DESCRIPTION FEATURES

Transcription:

TRANSDUCER IN-LINE Voltage Model AMPLIFIER 2080 Arlingate, Columbus, Ohio 43228, (614) 850-5000

Sensotec, Inc. 2080 Arlingate Lane Columbus, Ohio 43228 Copyright 1995 by Sensotec, Inc. all rights reserved TEL (614) 850-5000 FAX (614) 850-1111 1-800-848-6564 Voltage Transducer In-Line Model User s Guide Sensotec Part Number: 008-0171 - 00 Rev. A: September 1996 IMPORTANT! IT IS RECOMMENDED THAT YOU READ THIS DOCUMENT THOROUGHLY BEFORE APPLYING POWER TO THIS UNIT. THIS DOCUMENT CONTAINS INFORMATION ON WIRING, CALIBRATION, AND USE OF FEATURES.

TRANSDUCER IN-LINE AMPLIFIER VOLTAGE MODEL The SENSOTEC Transducer In-Line Amplifier is a small, rugged stainless steel package that can be connected between the transducer and a readout instrument. The In-Line Amplifier both supplies a highly regulated bridge excitation voltage for the transducer and converts the millivolt signal of the pressure transducer to a voltage signal of 0-5 VDC. The In-Line Amplifier includes: 1) Regulation on the input power circuit for use with unregulated 11-26 VDC. 2) Bridge excitation voltage regulator, after the input regulator, for accuracy. 3) High gain amplifier. 1.1 SPECIFICATIONS 4) Multi-turn zero and gain adjustments. Power requirements: 11-26 VDC unregulated @ 35mA. Output: 0-5 VDC with 0 volts = and 5 volts = with sensitivity of mv/v =. Output impedance: 250 ohms nominal. Bridge excitation factory set at VDC. Zero, gain adjustments: 15% nominal. Short circuit protected. Dimensions: 1 1/2 diameter; 3 long. Page 1 of 5 008-0171-00

1.2 WIRING INSTRUCTIONS Caution: Be sure amplifier power (11-26 VDC) is connected to Pins A and B (Fig.1). Permanent damage will occur as a result of an extended overvoltage applied to the incorrect pins. Step 1. Connect transducer, power supply, and readout instrument (see Fig. 1). Step 2. Allow amplifier to stabilize after power supply and readout instrument are connected (approximately 30 minutes). Figure 1 Note If leadwires between amplifier and readout are less than 10 ft., use Pins B or C as common for both power supply and signal return (3 wire system). If leadwires exceed 10 ft., use Pin B for power supply common and Pin C for signal common (4 wire system). Page 2 of 3 008-0171-00

1.3 CALIBRATION Note: Step 1. Step 2. Step 3. The shunt cal resistor is connected externally by the purchaser to Pins E and F (Fig. 1). The value of the shunt cal resistor is given on the transducer calibration sheet supplied by transducer manufacturer. Allow unit to warm up to stable reading. With no load or pressure on transducer, remove balance screw cover and with small screwdriver adjust zero balance potentiometer to indicate zero VDC on meter. Note: Since the amplifier is a unipolar device, the output will not go below zero VDC. Be careful not to have erroneous readings at zero. Apply either a full scale pressure or load to the transducer or a known shunt calibration resistance and adjust the gain potentiometer to full scale or desired output of the amplifier. Step 4. Recheck zero (Step 2.). Step 5. Repeat steps 2 and 3 until zero volts is equal to zero pressure, and 5 volts is equal to full scale output. CAUTION: NOTE: The zero BAL and GAIN adjustments are independent. However, any offset at zero will be added to the full scale output reading. Replace screw covers to prevent moisture from getting into amplifier. Page 3 of 3 008-0171-00

APPENDIX A.1.1 LIMITED WARRANTY ON PRODUCTS Any of our products which, under normal operating conditions, proves defective in material in workmanship within one year from the date of shipment by SENSOTEC, will be repaired or replaced free of charge provided that you obtain a return material authorization from SENSOTEC and send the defective product, transportation charges prepaid with notice of the defect, and establish that the product has been properly installed, maintained, and operated within the limits of rated and normal usage. Replacement product will be shipped F.O.B. our plant. The terms of this warranty do not extend to any product or part thereof which, under normal usage, has an inherently shorter useful life than one year. The replacement warranty detailed here is the buyer's exclusive remedy, and will satisfy all obligations of SENSOTEC whether based on contract, negligence, or otherwise. SENSOTEC is not responsible for any incidental or consequential loss or damage which might result from a failure of any SENSOTEC product. This express warranty is made in lieu of any and all other warranties, express or implied, including implied warranty of merchantability or fitness for particular purpose. Any unauthorized disassembly or attempt to repair voids this warranty. A.1.2 SERVICE UNDER WARRANTY Advanced authorization is required prior to the return to SENSOTEC. Before returning the items, either write to the Customer Service Department c/o SENSOTEC, Inc., 2080 Arlingate Lane, Columbus, Ohio 43228, or call (800) 848-6564 with: 1) a part number; 2) a serial number for the defective product; 3) a technical description* of the defect; 4) a no-charge purchase order number (so products can be returned to you correctly); and 5) ship and bill addresses. Shipment to SENSOTEC shall be at Buyer's expense and repaired or replacement items will be shipped F.O.B. our plant in Columbus, Ohio. Non-verified problems or defects may be subject to an evaluation charge. Please return the original calibration data with the unit. A.1.3 NON-WARRANTY SERVICE Advance authorization is required prior to the return to SENSOTEC. Before returning the item, either write to the Customer Service Department c/o SENSOTEC, Inc., 2080 Arlingate Lane, Columbus, Ohio 43228, or call (800) 848-6564 with: 1) a model number; 2) a serial number for the defective product; 3) a technical description* of the malfunction; 4) a purchase order number to cover SENSOTEC's repair cost; and 5) ship and bill addresses. After the product is evaluated by SENSOTEC, we will contact you to provide the estimated repair costs before proceeding. Shipment to SENSOTEC shall be at Buyer's expense and repaired items will be shipped to you F.O.B., our plant in Columbus, Ohio. Please return the original calibration data with the unit. Page 4 of 3 008-0171-00

A.1.4 REPAIR WARRANTY All repairs of SENSOTEC products are warranted for a period of 90 days from date of shipment. This warranty applies only to those items which were found defective and repaired, it does not apply to products in which no defect was found and returned as is or merely recalibrated. Out of warranty products may not be capable of being returned to the exact original specifications or dimensions. * Technical description of the defect: In order to properly repair a product, it is necessary for SENSOTEC to receive information specifying the reason the product is being returned. Specific test data, written observations on the failure and the specific corrective action you require is needed. Page 5 of 5 008-0171-00