Multi-Channel, Network-Enabled

Similar documents
NE SERIES. ne Models ne800 ne1600 ne2400

Protea-Equipped Media Amplifier

Protea-Equipped Media Amplifier

NXP SERIES. nxp Series. nxp nxp nxp nxp nxp nxp nxp nxp 3.02

pêma protea êquipped media amplifier

ne800 ne ne ne ne1600 ne ne ne2400 ne Network Enabled Two Channel Power Amplifiers Operating Manual

PowerMatch PM8500 / 8500N TECHNICAL DATA SHEET. configurable power amplifier. Key Features. Product Overview. Applications

DPA602 1/7. Multi-Channel Network Amplifier. General Description. Features. Applications. AtlasIED.com. DPA602 Front. DPA602 Back

PowerMatch PM8500 / PM8500N TECHNICAL DATA SHEET. configurable power amplifier. Key Features. Product Overview. Applications

PowerMatch PM4250 / PM4250N TECHNICAL DATA SHEET. configurable power amplifier. Key Features. Product Overview. Applications

FreeSpace IZA 2120-LZ Integrated Zone Amplifier

Overview. Features. Technical Data Sheet 1 / 5. Power Amplifier XMV8140-D

DNA Pro series 10K8 3K8

PowerShare PS602 adaptable power amplifier

DIGITAL CROSSOVERS AND DSP PROCESSORS

FreeSpace IZA 250-LZ / 190-HZ TECHNICAL DATA SHEET. integrated zone amplifier. Key Features. Product Overview. Product Information.

PowerShare PS604A adaptable power amplifier

MediaMatrix X-Frame 88

AX6220Z/AX6240Z. Energy-Efficient, DSP-Powered and Ethernet/USB-Controlled 1000/900-Watt 70/100 V High-Impedance Power Amplifier.

DSP AMPLIFIERS DI

Dodecahedron Speaker Set

WPE 48N USER MANUAL Version1.1

8101 SPECIFICATION SHEET

FreeSpace ZA 250-LZ / 190-HZ zone amplifier TECHNICAL DATA SHEET. Key Features. Product Overview. Product Information.

RM28ac. Self-Powered Dual 8 inch Coaxial Reference Monitor. product specification. Performance Specifications 1

Datasheet. Octadrive DSP-CN * Applies to Part Number: *This unit has a CobraNet interface installed

C1300FDi DSP power amplifier 2x650W, install

Sub218Lac. Self Powered Dual 18 inch Direct-Radiating Subwoofer. product specification. Performance Specifications 1

SPNTWB. Conference Interface - Wideband Bridging TECHNICAL DATA

Network Enabled Two Channel Power Amplifiers Operating Manual

FreeSpace ZA 250-LZ / 190-HZ zone amplifier TECHNICAL DATA SHEET. Key Features. Product Overview. Product Information.

MA6480A. Energy-Efficient, Multi-Function 240-Watt Mixing Amplifier with Dual 70/100 V and 4 Ohms Outputs. Features

Harman Pro Group Section: POWERED BY. Full Line Catalog Installed Sound Commercial Audio Portable PA Tour Sound Cinema Sound.

V2-1000N/2000N/3000N/4000N

FA12ac. Self-Powered 12 inch Coaxial Loudspeaker. product specification. Performance Specifications 1

MA40E Mini Amplifier with DSP

VSX Loudspeaker. Management Systems. VSX Output Filters

MA80FT Mini Amplifier

PB-400-CN. Datasheet. IndustryAmp PB-400-CN * Applies to Part Number: *This unit has a CobraNet interface installed

441 DUAL CHANNEL 15 BAND 2/3 OCTAVE GRAPHIC EQUALIZER 451 SINGLE CHANNEL 31 BAND 1/3 OCTAVE GRAPHIC EQUALIZER

TS212ac. Self Powered Dual 12 inch Direct-Radiating Subwoofer. product specification. Performance Specifications 1

digimix-18 Digital Mixing Consoles

TGX10 DSP power amplifier 4x2500W, live

Parque Tecnológico de Andalucía C/ Severo Ochoa Nº MÁLAGA, ESPAÑA Tlf: Fax:

SPNCWB. Wideband Bridging Conference Interface TECHNICAL DATA

REVAMP2600 Instruction manual

XO-Series Crossovers OPERATING MANUAL AND USER GUIDE. XO-Series Crossovers XO-204 XO-206 XO-204X XO-206X.

SPNCWB. Wideband Bridging Conference Interface TECHNICAL DATA

StudioLive MIXER INPUTS.

REVAMP2250 Instruction manual

CLEAR SET-UP AND CONFIGURATION ADVANCED REMOTE CONTROL AND SUPERVISION. Select amplifier type and activate through "drag and drop.

MA120 - MA240 Instruction manual

Mic Inputs: 12 high-performance, digitally controlled, auto-sensing mic pres, switchable +48V

Titan Modular Mainframe Amplifier Cards

HQ-31 HQ-15 USER S GUIDE SINGLE CHANNEL 31 BAND 1/3 OCTAVE GRAPHIC EQUALIZER DUAL CHANNEL 15 BAND 2/3 OCTAVE GRAPHIC EQUALIZER

SAGA PRO SERIES STEREO POWER AMPLIFIER OPERATION MANUAL

Specifications MPS 602

MC450/MC650 (MC750) OPERATING INSTRUCTIONS

Stereo / Mono. Audio Power Amplifier - 60 W. Introduction. Applications

Datasheet. IndustryAmp PB-800-CN * Applies to Part Number: *This unit has a CobraNet interface installed

Instruction Manual for Models

WMA 4300 Professional Series Installation Power Amplifer Owner s Manual

PRELIMINARY AA35G/AA60G. 3-Input, 35-Watt Mixer Amplifier with Global Power Supply

Owner s Manual B 300 B 600 B 900 B 1200 B 1500 B 902 B 1202 B 1802 B300 B1802

Tel. 0621/ FAX 0621/

data sheet MS-HM.01 AUDIO SYSTEM FOR INTEGRATION INTO MEDIA BOARDS

Dante. Dante Network Class D Professional Audio Amplifier D-3000

IPX5:4 DSP power amplifier 4x1250W, install

RACKHEAD Dual Tube/Solid-State Channel Bass Amp

FEATURES: Affordable, reliable power perfect for DRM Series Passive Loudspeakers, installations, and production audio systems

Clever Features, Contractor Friendly AMIS215EQ. Stereo 15 band 2/3 Octave Graphic Equalizer AMIS31EQ. Mono 31 band 1/3 Octave Graphic Equalizer

UMA 4300 Professional Series Installation Power Amplifer Owner s Manual

CX-A6 Amplifier Installation & User Guide V8.0

CX-A6 Amplifier Installation & User Guide V9.0

What is Helix??? It s a

PROFESSIONAL POWER AMPLIFIERS. User Instructions. American DJ V3000 LIMITER. American DJ LIMITER I LIMITER. ON channel 2

STEREO POWER AMPLIFIER OWNER MANUAL PR-150 DESIGNED IN U.K. PDF created with FinePrint pdffactory trial version

DPA74/154 AUDAC PROFESSIONAL AUDIO EQUIPMENT. DPA74/154 Quad Channel Class-D Amplifier. User Manual & Installation Guide

Important Note 1. Mains Supply (rack units) 4 DC Power Supply Indicators (rack units) Module Module and 1084 Modules 8

M 1400/M 1400i. M 1400/M 1400i AMPLIFIER. M 1400/M 1400i R E L A T E D P R O D U C T S 1 O F 8 P A G E S. High-Current Power Amplifier.

*TD * PLX Series Professional Audio Amplifiers User Manual. 4-ohm minimum impedance models with Speakon output terminals: PLX 1104 PLX 1804

A 4000 A Owner s Manual HPA HPA A4000 A5000 PROFESSIONAL POWER AMPLIFIER POWER CHANNEL 2 CHANNEL 1 PROFESSIONAL POWER AMPLIFIER POWER CHANNEL 2

FTX-1001 FTX-1501 FTX-2001 CFT-1800 Power Amplifier. Series III. Operating Manual

User's Manual PS 2/2A LTO R. Version 1.1 Septemper 2005 English

dbtechnologies DEVICE PLUGINS COD _Section_C_REV. 1.0

Overview. Features. Technical Data Sheet 1 / 6. Mixing Console MG20. MG20 is a versatile mixer suitable for a wide range of users and applications.

Installer Guide. Read Me First... PA 8 ELITE PA 8 ULTRA ELITE PA 16 ELITE. Multi-Channel Power Amplifiers. If you need help...

PARAMETER PARAMETER PARAMETER PARAMETER. M Series Digital Processing Unit. Operation Manual

X:SIDER. The guidelines of the project are high power, fine tuning, endurance, care for details and high fidelity in any situation.

The C Series from Lab.gruppen

PB 700 PB 1000 PB 1100 PB 1500 PB 2600 PB 1200 PB 1700 PB 2200 PB 2700 USER'S MANUAL.

System Power Amplifier (SPA)

ne 4250 ne 8250 ne ne ne ne ne ne

Z4MK3/Z8MK3 : Zone Mixers

4 Channel Frequency Conscious Noise Gate. Operation Manual

Owner s Manual D2500 D2000 D1500 D1000

Chapter 7: Signal Processing (SP) Tool Kit reference

1160 Stereo Power Amplifier

Danley Sound Labs. DNA 5K4c DSP Amplifier. User Guide version 2

M 1400/M 1400i. M 1400/M 1400i AMPLIFIER. M 1400/M 1400i R E L A T E D P R O D U C T S 1 O F 8 P A G E S. High-Current Power Amplifier.

Transcription:

5-Year Warranty Hand-built in Webster, NY 70V Rated 100V Rated ne4250 NE SERIES Multi-Channel, Network-Enabled Power Amplifiers Our multi-channel ne (Networked-Enabled) Series Amplifiers are uniquely designed around an energy efficient Class-D platform with a switching power supply. Connecting and controlling an amplifier for networked systems has now been simplified with ne Amplifiers. This line offers ease of use, setup and control using standard 10/100 Ethernet protocol and Protea ne Software. No special outboard control units are needed. Choose either the ne4250 (4-channel) or (8-channel) packages rated at 250W per channel, with separate Hi-Z and Low-Z models. ne Series Amplifiers are offered in two separate platforms the standard network amplifier or a network amplifier with an on-board Protea DSP Processor. Each can be customized for any installation by adding your choice of AES3 inputs, mic pre inputs*, CobraNet or Dante modules. ne4250 & Features: 10/100 Ethernet comes standard for remote control and monitoring Low-Z, 25V, 70V, 100V models Protea DSP, AES3, CobraNet and Dante input options DC voltage remote gain control Switched-mode power supply, Class-D output Stepped, calibrated input attenuators Remote power standby Disable all front panel controls via software Temperature sensitive variable speed fan with front-to-back airflow Selectable HPF frequencies (80Hz, 400Hz, off) on 25V, 70V, and 100V models 4-stage level meters Output current and temp indicators Safety/Compliance: ctuv us, CE, FCC, RoHS Front Panel Controls Cooling Individual input attenuators, AC Power Switch Temp dependent speed-controlled fan (Front in, Side out) LED Indicators: Unit Status POWER Blue Switch: On, Off STANDBY Yellow Standby, flashing PROTECT Red On, Off DISABLE Yellow On, Off COM Green On, for Ethernet data or Device ID LED Indicators: Each Channel Red Clip SIGNAL LEVEL Yellow -6dB Green -18dB, -12dB BRIDGE Green Per Channel Pair TEMP Yellow Per Channel CURRENT Green Per Channel: Proportional to output Remote Accessories WR-1 2-Channel Level Control WR-1.5 Level and Preset Recall WR-2 Four-Position Switch WR-5* Programmable Button Controller newr-5* Programmable Network Remote FR-8* 8-Channel Network Fader Remote FR-16* 16-Channel Network Fader Remote RD/RW-8C* Serial Data Fader Remote Ashly Remote* Remote Control Application for Apple ipad ne Models ne4250 Channels 4 8 Continuous Average Power Output: Per Channel, Low Z models, Stereo Mode, All Channels Driven 8 Ohms 150W 150W 4 Ohms 250W 250W Low Z Output: Bridge Mode, All Channels Driven 8 Ohms 500W 500W 25V, 70V, 100V Distributed Output Models: 20Hz 20kHz 1% THD 25V (per channel 250W 250W 70V (per channel) 250W 250W 100V (per channel) 250W 250W Line Current Draw: 120VAC Mains (divide in half for 230V) Standby Mode 190mA 290mA Idle (no signal) 540mA 565mA Typical (1/8 power pink noise) 2.85A 5.00A Maximum (1/3 power pink noise) 6.00A 11.0A Thermal Dissipation: BTU/hr, All Channels Driven Standby mode 46.7 63.8 Idle (no signal) 123 187 Typical (1/8 power pink noise) 341 700 Maximum (1/3 power pink noise) 378 775 Signal to Noise 20 20k, Unweighted >107dB >107dB Ashly Audio, Inc. 847 Holt Road Webster, New York 14580-9103 USA US toll free: +1-800-828-6308 tel: +1-585-872-0010 fax: +1-585-872-0739 info@ashly.com sales@ashly.com www.ashly.com *Remotes offered on Protea-equipped versions only. 2014 All features, specifications and graphical representations are subject to change without notice. Ashly Audio is a division of Jam Industries, Ltd. DS-1 1213

NE uses Neutrik Components Rear Panel NE SERIES Multi-Channel, Network-Enabled Power Amplifiers Specifications Note: 0dBu = 0.775 VRMS Response 20Hz 20kHz, (unweighted) ±1dB Input Impedance 20k Ohms, Balanced Voltage Gain 26dB (Low-Z), 32dB (70V), 35dB (100V) Input Sensitivity 6.2dBu (Low-Z), 4.2dBu (25V), 7.2dBu (70V), 7.2dBu (100V) Maximum Input Level +21dBu Software Contolled Internal HPF (25V, 70V, 100V models) 80Hz (12dB/oct), 400Hz (6dB oct), OFF Distortion (8 Ohm load) (SMPTE) <0.5% typical (THD-N) <0.5% typical () Damping Factor (8 Ohms, 1kHz) >250 Output Circuitry Class D Output Overcurrent, Main Supply Amplifier/Load Protection Rail Overvoltage, Chassis Temperature, Inrush Limiting, Mains Fuse Environmental 40-120 F, (4-49 C) noncondensing Rear Panel Controls Connectors (each channel) Power Requirements AC Main Power Cable Connector Ethernet 10/100, Channel bridge switch (Low-Z only), Remote standby, Preset recall (4), Remote Level (8), Remote Data Input: Euroblock Output: Euroblock 120VAC or 240VAC, ±10% 50 60Hz 15A Edison, 3-Prong IEC Weights and Dimensions Dimensions 19 W x 3.50" H x 15.5 D (483mm x 88.9mm x 394mm) Unit Weight 4250: 18lbs (8.18kg) 8250: 19.7lbs (8.95kg) Shipping Weight 4250: 25lbs (11kg) 8250: 26lbs (12kg) Ashly Audio is a division of Jam Industries, Ltd.

ne4250 Digital Signal Processing for NE Multi-Channel Protea is compatible with Microsoft Windows 8, 7 (Vista/XP) 32 & 64 bit systems. Audio professionals find our Protea DSP to be very intuitive and easy to navigate and you will too. No need to attend a one-week training class away from home to learn our software. Common sense layout of controls and features, on-line help, or a visit to the Technical Support page on our website provides answers to all of your questions. Protēa DSP Specifications All DSP functions can be linked to 1 of 16 link groups Input Source Selection Input Source Select Options Analog, Auto (Net, AES3, Analog) Brick Wall Limiter -20dBu to +20dBu Ratio Infinite 0.2ms/dB to 50 ms/db Compressor -20dBu to +20dBu Ratio 1.2:1 to infinite 0.2 to 50ms Detector Peak/Average Attenuation Bus 2 available In, Out, Attenuation, Graphical Autoleveler Controls Target Level -40dBu to +20dBu Action Gentle, normal, aggressive, user defined Maximum Gain 0dB to +22dB Input, Gain, Attenuation Ratio 1.2:1 to 10:1 Below Target -30dB to 0dB Gain Increase/Decrease Rate Hold Time 0-6 sec Ducking: High/Low Priority, Trigger, Filibuster, Ducked Program Trigger -80dBu to +20 dbu Ducking Ducking Depth 0dB to -30dB, - Enable Ducking at Matrix Mixer Yes Input Gate -80dBu to +20dBu Range off, 100dB to 0dB 0.2ms/dB to 50 ms/db Key Signal, Gate LED, Graphical Advanced Gate Controls Key Engage Enable Yes Key 20Hz to 20kHz Key Bandwidth 0.016 to 3.995 Octave Gain Gain (with/without VCA) -50dB to +12dB, off, polarity invert Digital VCA Groups 4 available Remote RD8C Gain Enable per channel, 0dB to - WR-5 (newr-5) Remote Gain 0 to -50dB, Mute EQ: 31-Band Filter Type Constant Q or proportional Bandwidth 0.499oct to 0.25oct EQ: Parametric 2,4,6, or 10 Band 20-20kHz Level -30dB to +15dB Q Value 0.016 to 3.995 Octave EQ: Hi/Low Shelf 6/12 db/oct Level -15dB to +15dB EQ: All Pass EQ: Variable Q HP/LP Q Value 3.047 to 0.267 EQ: Notch/Bandpass Q Value 92.436 to 0.267 Crossover: 2 Way, 3 Way, 4 Way Crossover & High Pass/Low Pass Filters Bessel & Butterworth Filters 12/18/24/48 db/oct Linkwitz-Riley Filter 12/24/48 db/oct Off, 20Hz-20KHz Delay: @ 48kHz Sampling Rate (Input Time, Distance & Temperature) Speaker Delay 0-21ms Delay 0-682ms Delay: @ 96kHz Sampling Rate (Input Time, Distance & Temperature) Speaker Delay 0-10.6ms Delay 0-341ms Audio Tool Range -60dBu to +20dBu Increments 1dB Peak Hold Indicator Yes Signal Generator Tool: Pink noise, White noise, Sine wave Signal Level Off, -50dBu to +20dBu Sine Wave 20Hz-12kHz Matrix Mixer Gain (0.5dB increments) Off., -50 to +12dB Mute Per channel Enable Ducking at Mixer Yes Processors Input A/D, Output D/A 24 bit DSP Processors 32-bit floating point Sample Rates 48kHz, 96kHz Propagation Delay @ 48kHz: 1.42ms Propagation Delay @ 96kHz: 0.71ms

NE 4250 Architect & Engineering Specs ne4250 The four-channel power amplifier shall deliver a minimum power of 150 Watts RMS per channel into 8 Ohm loads and 250 Watts RMS per channel into 4 Ohm loads with all channels operating. When switched into bridged-mono mode, channels 1+2 or 3+4 of the amplifier shall deliver at least 500 Watts RMS into an 8 Ohm load. The power amplifier shall include Euroblock input connectors and Euroblock output connectors. It shall have balanced analog inputs. The power amplifier shall have remote standby for power up, DC remote level control and contact closure preset recall. It shall have Ethernet control and monitoring of power functions, level, mute, polarity, temperature, current, and amplifier fault conditions. response shall be 20Hz to 20kHz + 1.0dB. Signal-to-Noise shall be greater than 98dB unweighted and SMPTE intermodulation distortion shall be less than.5% into an 8 Ohm load, 10dB below rated output. The front panel shall provide the status of power, standby, protect, power switch disable, signal level, bridge, over-temperature, over-current, and Ethernet communication. The amplifier shall mount in a standard 19 inch rack using two spaces (3.5. high) and weigh 19.7pounds (9kg) or less. The power amplifier shall be an Ashly model ne4250 The power amplifier with a factory installed AES option shall be an Ashly model ne4250d The power amplifier with a factory installed CobraNet option shall be an Ashly model ne4250c ne4250 with DSP Option The four-channel power amplifier shall deliver a minimum power of 150 Watts RMS per channel into 8 Ohm loads and 250 Watts RMS per channel into 4 Ohm loads with all channels operating. When switched into bridged-mono mode,channels 1+2 or 3+4 of the amplifier shall deliver at least 500 Watts RMS into an 8 Ohm load. The power amplifier shall include Euroblock input connectors and Euroblock output connectors. It shall have balanced analog inputs. The power amplifier shall have remote standby for power up, DC remote level control and contact closure preset recall. It shall have Ethernet control and monitoring of power functions, level, mute, polarity, temperature, current, and amplifier fault conditions. response shall be 20Hz to 20kHz + 1.0dB. Signal-to-Noise shall be greater than 98dB unweighted and SMPTE intermodulation distortion shall be less than.5% into an 8 Ohm load, 10dB below rated output. The front panel shall provide the status of power, standby, protect, power switch disable, signal level, bridge, over-temperature, over-current, and Ethernet communication. The power amplifier shall have an internal factory installed digital signal processing (DSP) option controlled using Protea (network enabled) software. Each amplifier input channel shall be configured with pluggable DSP blocks to have its own dynamics control, gain functions, graphic and/or parametric EQ, Hi-pass/Lo-pass filters, time delay, metering, and test signal generator. A mixer section with assignable routing shall allow any input to drive any or all amplifier outputs. Outputs shall have the same DSP functions as inputs, with the addition of a fast, automated crossover setup. Both inputs and outputs shall copy/paste their settings to other channels, or link with one or more other channels to track their settings. Presets shall be used to store and retrieve global parameters of an amplifier s control surface and DSP section from a file. Sub-Presets shall allow for a collection of individual DSP function parameters within and across both channels of an amplifier to be stored and recalled as a set, affecting only those parameters which have been tagged. Up to 35 presets/sub-presets shall be stored within the amplifier, and shall be recalled in real time via Ethernet from a computer using Protea software. The amplifier shall mount in a standard 19 inch rack using two spaces (3.5. high) and weigh 19.7 pounds (9kg) or less. The power amplifier shall be an Ashly model ne4250pe The power amplifier with a factory installed AES option shall be an Ashly model ne4250ped The power amplifier with a factory installed CobraNet option shall be an Ashly model ne4250pec ne4250.70 The four-channel power amplifier shall deliver a minimum power of 250 Watts RMS per channel into 70V loads with all channels operating. When switched into bridged-mono mode, channels 1+2 or 3+4 of the amplifier shall deliver at least 500 Watts RMS into a 140V load. The power amplifier shall include Euroblock input connectors and Euroblock output connectors. It shall have balanced analog inputs. The power amplifier shall have remote standby for power up, DC remote level control and contact closure preset recall. It shall have Ethernet control and monitoring of power functions, level, mute, polarity, temperature, current, and amplifier fault conditions. response shall be 20Hz to 20kHz + 1.0dB. Signal-to-Noise shall be greater than 98dB unweighted and SMPTE intermodulation distortion shall be less than.5% into an 8 Ohm load, 10dB below rated output. The front panel shall provide the status of power, standby, protect, power switch disable, signal level, bridge, over-temperature, over-current, and Ethernet communication. The amplifier shall mount in a standard 19 inch rack using two spaces (3.5. high) and weigh 19.7 pounds (9kg) or less. The power amplifier shall be an Ashly model ne4250.70 The power amplifier with a factory installed AES option shall be an Ashly model ne4250.70d The power amplifier with a factory installed CobraNet option shall be an Ashly model ne4250.70c ne4250.70 with DSP Option The four-channel power amplifier shall deliver a minimum power of 250 Watts RMS per channel into 70V loads with all channels operating. When switched into bridged-mono mode, channels 1+2 or 3+4 of the amplifier shall deliver at least 500 Watts RMS into a 140V load. The power amplifier shall include Euroblock input connectors and Euroblock output connectors. It shall have balanced analog inputs. The power amplifier shall have remote standby for power up, DC remote level control and contact closure preset recall. It shall have Ethernet control and monitoring of power functions, level, mute, polarity, temperature, current, and amplifier fault conditions. response shall be 20Hz to 20kHz + 1.0dB. Signal-to-Noise shall be greater than 98dB unweighted and SMPTE intermodulation distortion shall be less than.5% into an 8 Ohm load, 10dB below rated output. The front panel shall provide the status of power, standby, protect, power switch disable, signal level, bridge, over-temperature, over-current, and Ethernet communication. The power amplifier shall have an internal factory installed digital signal processing (DSP) option controlled using Protea (network enabled) software. Each amplifier input channel shall be configured with pluggable DSP blocks to have its own dynamics control, gain functions, graphic and/or parametric EQ, Hi-pass/Lo-pass filters, time delay, metering, and test signal generator. A mixer section with assignable routing shall allow any input to drive any or all amplifier outputs. Outputs shall have the same DSP functions as inputs, with the addition of a fast, automated crossover setup. Both inputs and outputs shall copy/paste their settings to other channels, or link with one or more other channels to track their settings. Presets shall be used to store and retrieve global parameters of an amplifier s control surface and DSP section from a file. Sub-Presets shall allow for a collection of individual DSP function parameters within and across both channels of an amplifier to be stored and recalled as a set, affecting only those parameters which have been tagged. Up to 35 presets/ sub-presets shall be stored within the amplifier, and shall be recalled in real time via Ethernet from a computer using Protea software. The amplifier shall mount in a standard 19 inch rack using two spaces (3.5. high) and weigh 19.7 pounds (9kg) or less. The power amplifier shall be an Ashly model ne4250.70pe The power amplifier with a factory installed AES option shall be an Ashly model ne4250.70ped The power amplifier with a factory installed CobraNet option shall be an Ashly model ne4250.70pec

NE 8250 Architect & Engineering Specs The eight-channel power amplifier shall deliver a minimum power of 150 Watts RMS per channel into 8 Ohm loads and 250 Watts RMS per channel into 4 Ohm loads with all channels operating. When switched into bridged-mono mode, channels 1+2 or 3+4 or 5+6 or 7+8 of the amplifier shall deliver at least 500 Watts RMS into an 8 Ohm load. The power amplifier shall include Euroblock input connectors and Euroblock output connectors. It shall have balanced analog inputs. The power amplifier shall have remote standby for power up, DC remote level control and contact closure preset recall. It shall have Ethernet control and monitoring of power functions, level, mute, polarity, temperature, current, and amplifier fault conditions. response shall be 20Hz to 20kHz + 1.0dB. Signal-to-Noise shall be greater than 98dB unweighted and SMPTE intermodulation distortion shall be less than.5% into an 8 Ohm load, 10dB below rated output. The front panel shall provide the status of power, standby, protect, power switch disable, signal level, bridge, over-temperature, over-current, and Ethernet communication. The amplifier shall mount in a standard 19 inch rack using two spaces (3.5. high) and weigh 21 pounds (10kg) or less. The power amplifier shall be an Ashly model The power amplifier with a factory installed AES option shall be an Ashly model d The power amplifier with a factory installed CobraNet option shall be an Ashly model c with DSP Option The eight-channel power amplifier shall deliver a minimum power of 150 Watts RMS per channel into 8 Ohm loads and 250 Watts RMS per channel into 4 Ohm loads with all channels operating. When switched into bridged-mono mode, channels 1+2 or 3+4 or 5+6 or 7+8 of the amplifier shall deliver at least 500 Watts RMS into an 8 Ohm load. The power amplifier shall include Euroblock input connectors and Euroblock output connectors. It shall have balanced analog inputs. The power amplifier shall have remote standby for power up, DC remote level control and contact closure preset recall. It shall have Ethernet control and monitoring of power functions, level, mute, polarity, temperature, current, and amplifier fault conditions. response shall be 20Hz to 20kHz + 1.0dB. Signal-to-Noise shall be greater than 98dB unweighted and SMPTE intermodulation distortion shall be less than.5% into an 8 Ohm load, 10dB below rated output. The front panel shall provide the status of power, standby, protect, power switch disable, signal level, bridge, over-temperature, over-current, and Ethernet communication. The power amplifier shall have an internal factory installed digital signal processing (DSP) option controlled using Protea (network enabled) software. Each amplifier input channel shall be configured with pluggable DSP blocks to have its own dynamics control, gain functions, graphic and/or parametric EQ, Hi-pass/Lo-pass filters, time delay, metering, and test signal generator. A mixer section with assignable routing shall allow any input to drive any or all amplifier outputs. Outputs shall have the same DSP functions as inputs, with the addition of a fast, automated crossover setup. Both inputs and outputs shall copy/paste their settings to other channels, or link with one or more other channels to track their settings. Presets shall be used to store and retrieve global parameters of an amplifier s control surface and DSP section from a file. Sub-Presets shall allow for a collection of individual DSP function parameters within and across both channels of an amplifier to be stored and recalled as a set, affecting only those parameters which have been tagged. Up to 35 presets/sub-presets shall be stored within the amplifier, and shall be recalled in real time via Ethernet from a computer using Protea software. The amplifier shall mount in a standard 19 inch rack using two spaces (3.5. high) and weigh 21 pounds (10kg) or less. The power amplifier shall be an Ashly model pe The power amplifier with a factory installed AES option shall be an Ashly model ped The power amplifier with a factory installed CobraNet option shall be an Ashly model pec.70 The eight-channel power amplifier shall deliver a minimum power of 250 Watts RMS per channel into 70V loads with all channels operating. When switched into bridged-mono mode, channels 1+2 or 3+4 or 5+6 or 7+8 of the amplifier shall deliver at least 500 Watts RMS into a 140V load. The power amplifier shall include Euroblock input connectors and Euroblock output connectors. It shall have balanced analog inputs. The power amplifier shall have remote standby for power up, DC remote level control and contact closure preset recall. It shall have Ethernet control and monitoring of power functions, level, mute, polarity, temperature, current, and amplifier fault conditions. response shall be 20Hz to 20kHz + 1.0dB. Signal-to-Noise shall be greater than 98dB unweighted and SMPTE intermodulation distortion shall be less than.5% into an 8 Ohm load, 10dB below rated output. The front panel shall provide the status of power, standby, protect, power switch disable, signal level, bridge, over-temperature, overcurrent, and Ethernet communication. The amplifier shall mount in a standard 19 inch rack using two spaces (3.5. high) and weigh 21 pounds (10kg) or less. The power amplifier shall be an Ashly model.70 The power amplifier with a factory installed AES option shall be an Ashly model.70d The power amplifier with a factory installed CobraNet option shall be an Ashly model.70c.70 with DSP Option The eight-channel power amplifier shall deliver a minimum power of 250 Watts RMS per channel into 70V loads with all channels operating. When switched into bridged-mono mode, channels 1+2 or 3+4 or 5+6 or 7+8 of the amplifier shall deliver at least 500 Watts RMS into a 140V load. The power amplifier shall include Euroblock input connectors and Euroblock output connectors. It shall have balanced analog inputs. The power amplifier shall have remote standby for power up, DC remote level control and contact closure preset recall. It shall have Ethernet control and monitoring of power functions, level, mute, polarity, temperature, current, and amplifier fault conditions. response shall be 20Hz to 20kHz + 1.0dB. Signal-to-Noise shall be greater than 98dB unweighted and SMPTE intermodulation distortion shall be less than.5% into an 8 Ohm load, 10dB below rated output. The front panel shall provide the status of power, standby, protect, power switch disable, signal level, bridge, over-temperature, overcurrent, and Ethernet communication. The power amplifier shall have an internal factory installed digital signal processing (DSP) option controlled using Protea (network enabled) software. Each amplifier input channel shall be configured with pluggable DSP blocks to have its own dynamics control, gain functions, graphic and/or parametric EQ, Hi-pass/Lo-pass filters, time delay, metering, and test signal generator. A mixer section with assignable routing shall allow any input to drive any or all amplifier outputs. Outputs shall have the same DSP functions as inputs, with the addition of a fast, automated crossover setup. Both inputs and outputs shall copy/paste their settings to other channels, or link with one or more other channels to track their settings. Presets shall be used to store and retrieve global parameters of an amplifier s control surface and DSP section from a file. Sub-Presets shall allow for a collection of individual DSP function parameters within and across both channels of an amplifier to be stored and recalled as a set, affecting only those parameters which have been tagged. Up to 35 presets/sub-presets shall be stored within the amplifier, and shall be recalled in real time via Ethernet from a computer using Protea software. The amplifier shall mount in a standard 19 inch rack using two spaces (3.5. high) and weigh 21 pounds (10kg) or less. The power amplifier shall be an Ashly model.70pe The power amplifier with a factory installed AES option shall be an Ashly model.70ped The power amplifier with a factory installed CobraNet option shall be an Ashly model.70pec