EMC TEST REPORT CE TEST REPORT. for Audio / Video receivers and associated equipment

Similar documents
EMC TEST REPORT CE TEST REPORT. Report Number : ETLE Report issue date: August 21, 2009

TEST REPORT TEST REPORT. Report Number : ETLE Report issue date: May 26, Address : , Gongreung-dong, Nowon-gu, Seoul, Korea

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

FCC TEST REPORT. Table of Contents. FCC Measurement Report

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

FCC TEST REPORT. Table of Contents. Report no. ETLE , Page 2 of 21

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

TEST REPORT... 1 CONTENT...

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-12

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-10

EMC TEST REPORT. Report No. : EM/2004/10096 Page : 1 of 19

ELECTRONICS TESTING CENTER(ETC), TAIWAN

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

Declaration of Conformity.

2620 Modular Measurement and Control System

Certificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

BUREAU VERITAS. itaste svd

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758

1 SUMMARY OF STANDARDS AND RESULTS

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

EMC VERIFICATION SUMMARY Report No.: SZHH

EMC TEST REPORT. According to

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

EMC test report AU01+E04

TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST CONDUCTED EMISSION TEST RADIATED EMISSION TEST 11

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

EMC Test Report. Report Number: M030826

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated

CE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

Contents. Report No.: EMC-CE-2114 Page: 2 of 39

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

EMC TEST REPORT For CE

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

EMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter

EN v3.1.1 TEST REPORT FOR. Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017

EMC standards. Presented by: Karim Loukil & Kaïs Siala

Test Report GUANGDONG EAST POWER CO., LTD

BS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE

ENGINEERING TEST REPORT #: A LSR JOB #: C-2411

FCC TEST REPORT. Table of Contents. Report no. ETLE , Page 2 of 21

EMC Test report for LED Panel Light Models , , , , ,

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

ETSI EN V2.2.0 ( ) ETSI EN V2.1.1 ( ) TEST REPORT. United GULF GATE Co.

Test Report. Ningbo Goldmore Industrial Co.,Ltd.

CE CONFORMANCE REPORT

TABLE OF CONTENTS Page 1 of VERIFICATION OF CONFORMITY SYSTEM DESCRIPTION PRODUCT INFORMATION SUPPORT EQUIPMENT

Report No.: 9A042401C2 Page 1 of 36. Test Report EN : Prepared for

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST CONDUCTED EMISSION TEST RADIATED EMISSION TEST 10

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

IST EMC LAB. EMISSION TEST REPORT. : DSP-4284GM Basic Alternate. : PDP(Plasma Display Panel) : Daewoo Electronics Corp. : Daewoo Electronics Corp.

TEST REPORT. Table of Contents

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

EMC TEST REPORT. Report No.: CE10-LIE040101E

DIRECTORY - EMISSIONS

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

Guangdong East Power Co., Ltd. Uninterruptible Power Systems

EMI T E S T R E P O R T

TEST REPORT. Report No. : EM/2008/80003 Page : 1 of 54

FCC TEST REPORT FCC ID: PFNDMS2344UHDW

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi

EN v1.2.1 ( ) TEST REPORT FOR b/g PCIExpress Minicard MODEL NUMBER: AR5BXB63 REPORT NUMBER: 06U

A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan

9. Electrostatic Discharge Immunity Test (ESD)

FCC TEST REPORT FCC ID: PFNDMS-2344UHDS

Revision history. Revision Date of issue Test report No. Description KES-E Initial

Page: 1 of 41 EMC TEST REPORT. Product Name : Multi-socket with surge protection : SPG3-B-10, SPG3-B-15, SPG3-B-5, SPG3-B-6

Test and Measurement for EMC

EMISSION. EN : 2006 Clause 6.5 Pass. Harmonic Current EN : 2006+A1: 2009+A2: 2009 Class A Pass

EMC TEST REPORT. ADDRESS : #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

C E R T I F I C A T I O N

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49

ELECTRONICS TESTING CENTER, TAIWAN

EMC TEST REPORT. according to

SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE

EMC TEST REPORT. According to

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

Transcription:

CE TEST REPORT for Audio / Video receivers and associated equipment Report Number : ETLE100104.03 Report Issue Date: January 15, 2010 Model / Serial No. : WSTA-VM300P / NONE Multiple Model Name : WSTA-VM320P, WSTA-VM330P, WSTA-VM300PM, WSTA-VM320PM, WSTA-VM330PM, CSA-370, CSA-370M, CSA-370P, Freeway 2M, ATL300M, WSTA-VM37TF Product Type : Inmotion Satellite Antenna Brand name : Applicant : WiWORLD CO.,Ltd. Address : 585-1 Yongsan-dong, Yuseong-gu, Daejeon 305-500 Korea Manufacturer : WiWORLD CO.,Ltd. Address : 585-1 Yongsan-dong, Yuseong-gu, Daejeon 305-500 Korea Test Standard(s) : EN 55013: 2001 + A1: 2003 + A2: 2006 EN 55020: 2007 Test Result : Positive Total pages including Attachments : 36 Prepared by: Hyung Min, Choi (Test Engineer) Reviewed by: Yo Han, Park (Chief Engineer) January 15, 2010 January 15, 2010 ETL Inc. #371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel: 82-2-858-0786 Fax: 82-2-858-0788 The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory Report no. ETLE100104.03, Page 1 of 19

DIRECTORY Pages A) Documentation Directory 2 Test Standards 3 Address of the test laboratory, Conditions/Power Utilized, Description of the EUT & Symbol Definitions 4 Equipment under Test 15 General Remarks & Summary 16 Test Setups (Photographs) 17 19 B) Test Data Conducted Emissions 150 khz - 30 MHz 5 Interference power Emissions 30 MHz - 300 MHz 6 Harmonic Current Emissions and Flicker 7 Susceptibility test EN 55020 150 khz - 150 MHz 8 Electrostatic Discharge (ESD) 9 12 Radiated Electromagnetic Fields 13 EFT / Burst 14 C) Attachment A. Test Data A1 A5 B. List of Test Equipments B1 B2 C. Photo documentations C1 C8 D. Technical description of the test sample (e.g.cdf, Declaration) D1 D2 Report no. ETLE100104.03, Page 2 of 19

EMC TEST STANDARD(S) The emc tests were performed according to the following standards: EMC - Directive 2004/108/EC and its amendments ----------------------------------------------------------------------- EN 55013: 2001 + A1: 2003 + A2: 2006 EN 55020: 2007 IEC 61000-4-2: 1995 + A1: 1998 + A2: 2000 IEC 61000-4-3: 2006 + A1: 2007 IEC 61000-4-4: 2004 EN 61000-3-2: 2006 EN 61000-3-3: 2008 Note: For undated references, the latest edition of the publication at the time of testing (including amendments) was applied. Report no. ETLE100104.03, Page 3 of 19

ADDRESS OF THE TEST LABORATORY Seoul EMC Laboratory #371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Hwaseong Open Area Test Site #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea ENVIRONMENTAL CONDITIONS During the measurement the environmental conditions were within the listed ranges: Temperature : 15 C - 35 C Humidity : 30 %R.H. - 60 %R.H. Atmospheric Pressure : 86 kpa - 106 kpa POWER SUPPLY SYSTEM UTILIZED Power supply system DC 12 V SHORT DESCRIPTION OF THE EQUIPMENT UNDER TEST (EUT) Number of received / tested samples: 1 / 1 Serial Number: none DEFINITIONS FOR SYMBOLS USED IN THIS TEST REPORT The black square indicates that the listed condition, standard or equipment is applicable for this report. Blank box indicates that the listed condition, standard or equipment was not applicable for this report. Report no. ETLE100104.03, Page 4 of 19

Conducted Emission (Interference Voltage) Test Conducted emissions were measured from 150 khz to 30 MHz with a bandwidth of 9 khz on the 230 V AC power and return leads of the EUT according to the methods defined in EN 55013. The EUT was placed upon a non-metallic table 0.8 m above the horizontal metal reference plane and placed 40 cm from a vertical ground plane which is connected to the horizontal metal ground plane. Test not applicable Test area - mesh room Anechoic chamber Full compact chamber Used test instruments and test accessories please see Attachment B. Equipment type Television and sound receivers and associated equipment Frequency Range [MHz] Note. 1) Decreasing linearly with the logarithm of the frequency. Quasi-Peak limit [db( μv )] Average limit [db( μv )] 0.15 to 0.5 66 to 56 1) 56 to 46 1) 0.5 to 5 56 46 5 to 30 60 50 Pass Fail Minimum limit margin db at MHz Maximum limit exceeding db at MHz Remarks: This test was not applied. Because, EUT power supplies from a DC 12 V. Report no. ETLE100104.03, Page 5 of 19

Interference power Emissions Test Interference power at the antenna terminal was performed in a shielded room by using the absorbing clamp on the mains and interface cables in the frequency range 30 MHz - 300 MHz. Test not applicable Test area - open site Anechoic chamber Full compact chamber Used test instruments and test accessories please see Attachment B. Equipment type Frequency Range [MHz] Quasi-Peak limit [db(pw)] Average limit [db(pw)] Associated equipment (Video recorders exciuded) 30 to 300 45 to 55 1) 35 to 45 1) Note. 1) Increasing linearly with the frequency. Pass Fail Minimum limit margin 3.40 db at 200.002 MHz Maximum limit exceeding db at MHz Remarks: Please refer to the test data and graph in Attachment A. Report no. ETLE100104.03, Page 6 of 19

Harmonic Current Emissions and Flicker Power Frequency Harmonics Tests: The measured values of the harmonics components of the input current, including line current and neutral current, shall be compared with the limits given in EN 61000-3-2. Flicker Emission Tests: The total impedance of the test circuit, excluding the appliance under test, but including the internal impedance of the supply source, shall be equal to the reference impedance. Test not applicable Test area - ETL Harmonics test room Anechoic chamber Full compact chamber Used test instruments and test accessories please see Attachment B. Pass Fail Remarks: This test was not applied. Because, EUT power supplies from a DC 12 V. Report no. ETLE100104.03, Page 7 of 19

Susceptibility Test (EN 55020) This standard for immunity requirements applies to television broadcast receivers, sound broadcast receivers and associated equipment intended for use in the residential, commercial and light industrial environment. Test not applicable Test area - ETL AV Test lab. Used test instruments and test accessories please see Attachment B. Pass Fail Remarks: This test was not applied. Because, EUT doesn t have tuner. Report no. ETLE100104.03, Page 8 of 19

Electrostatic Discharge (ESD) Immunity Test Tests were conducted in accordance with IEC 61000-4-2. The test programs and software shall be chosen so as to exercise all normal modes of operation of the EUT. The use of special exercising software is encouraged, but permitted only where it can be shown that the EUT is being comprehensively exercised. Test not applicable ETL Test Room Used test instruments and test accessories please see Attachment B. Test specifications: Discharge Voltage (Air): 2.0 kv 4.0 kv 6.0 kv 8.0 kv Discharge Voltage (Contact): 2.0 kv 4.0 kv Discharge Impedance: Discharge Repetition Rate: Number of Discharges: Kind of Discharges: 330 Ω / 150 pf 1 s 10 at all locations Air discharge Contact discharge Polarity: Positive Negative Location of Discharge: See Photograph (ESD Point map) Each location on the surface touchable by hand HCP, VCP Required performance criterion: B Test results: PASS (Met criterion A) Remarks: No false or other malfunctions were observed during and after the test. Please refer to the test point in next page. Report no. ETLE100104.03, Page 9 of 19

Test data Test Point Discharge Type Discharge voltage [± kv] Result HCP / VCP Indirect 2 / 4 Met criterion A 1. Antenna surface Air 2 / 4 / 6 / 8 Met criterion A 2. Antenna port Contact 2 / 4 Met criterion A 3. Metal cover of Receiver Contact 2 / 4 Met criterion A 4. Tuner port of Receiver Contact 2 / 4 Met criterion A 5. RS-232C port of Receiver Contact 2 / 4 Met criterion A 6. Front of Receiver Air 2 / 4 / 6 / 8 Met criterion A Report no. ETLE100104.03, Page 10 of 19

CONTACT AIR 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 Report no. ETLE100104.03, Page 11 of 19

CONTACT AIR 3 3 3 3 6 6 6 6 3 6 3 3 3 3 3 3 4 5 3 3 Report no. ETLE100104.03, Page 12 of 19

Radiated Electromagnetic Fields Immunity Test Tests were conducted in accordance with IEC 61000-4-3 over the frequency range of 900 MHz. The transmitting antenna was located 3 m from the EUT at a height of 0.8 m above the front side of the EUT was positioned parallel to the antenna line of sight, The EUT was exposed to a uniform field of 3 V/m using vertical antenna polarizations. Test not applicable ETL immunity chamber Full compact chamber Used test instruments and test accessories please see Attachment B. Test specifications: Frequency Range / Field Strength: 900 MHz / 3 V/m 80 MHz - 150 MHz / EN 55020 Table 7 Distance Antenna - EUT: 3 m Modulation: AM 1 khz 80 % Pulse (Repetition freq. 217 Hz, Duty cycle: 1/8) Dwell Time: 3 s Polarization of Antenna: Horizontal Vertical Position of EUT: 0 90 180 270 Required performance criterion: A Test result: PASS (Met criterion A) Test data Frequency Range [MHz] Antenna Polarity Position [Angle] Result 900 Vertical Right / Left Met criterion A Remarks: No false or other malfunctions were observed during and after the test. Report no. ETLE100104.03, Page 13 of 19

EFT/Burst Immunity Test Tests were conducted in accordance with IEC 61000-4-4. Test not applicable ETL Test Room Used test instruments and test accessories please see Attachment B. Test specifications: Pulse Amplitude - AC Power Port: 1.0 kv 2.0 kv Burst Frequency: Time of Coupling: 5.0 khz 60 s Polarity: Positive Negative Location of Coupling Name of lines Type Length Remarks - - - Required performance criterion: Test result: B N/A Test data Line Line for test Test level [± kv] Coupling Method - - - - - Result Remarks: This test was not applied. Because, EUT power supplies from a DC 12 V. Report no. ETLE100104.03, Page 14 of 19

E Q U I P M E N T U N D E R T E S T Operation mode of the EUT.: The equipment under test was operated during the measurement under following conditions: Searching satellite mode Configuration of the equipment under test: Following devices and interface cables were connected during the measurement: Peripheral devices Type Model Serial no. Manufacturer DC Power Supply E3616A KR64301658 H.P Type of Cables Used Device from Device to Type of Cable(Port) Length[m] Type of shield EUT (Antenna) EUT (Receiver) LNB port >10.0 Shielded EUT (Receiver) DC Power Supply DC Input 1.0 Unshielded DC Power Supply Power socket AC Input 1.0 Unshielded Report no. ETLE100104.03, Page 15 of 19

S U M M A R Y GENERAL REMARKS: The Equipment Under Test (EUT) is the Inmotion Satellite Antenna (model: WSTA-VM300P). The model WSTA-VM300P is basic that was tested. The multi models WSTA-VM320P, WSTA-VM330P, WSTA-VM300PM, WSTA-VM320PM and WSTA- VM330PM are identical to basic model, except for model designation, dish type and azimuth range. The multi models CSA-370, CSA-370M, CSA-370P, Freeway 2M, ATL300M and WSTA-VM37TF are name at the request of buyer, identical to basic model, except for model designation. FINAL JUDGEMENT: The requirements according to the technical regulations and tested operation modes are - met. - not met. Criterion description Criterion A : No loss of performance or function Criterion B : The apparatus shall continue operate as intended after test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. Criterion C : Temporary loss of function or performance, which is provided the function, is self-recoverable or can be restored by the operation of the controls. The Equipment Under Test - Fulfills the general approval requirements cited on page 3. - Does not fulfill the general approval requirements cited on page 3. Date of receipt of test sample : January 04, 2010 Test start date : January 04, 2010 Test end date : January 12, 2010 Report no. ETLE100104.03, Page 16 of 19

Photograph of test setup: Interference power Emissions 30 MHz - 300 MHz Report no. ETLE100104.03, Page 17 of 19

Photograph of test setup: Electrostatic discharge (ESD) Report no. ETLE100104.03, Page 18 of 19

Photograph of test setup: Radiated electromagnetic field Report no. ETLE100104.03, Page 19 of 19

Attachment A Test Data and Test Setup Drawing(s) Summary Page Test Item Result ------------- : S1 (Input Immunity) met not met N/A ------------- : S2a (RFI Voltage immunity) met not met N/A ------------- : S2b (RFI Current immunity) met not met N/A ------------- : S3 (RFI Field Immunity) met not met N/A ------------- : S4 (Screen Effectiveness) met not met N/A ------------- : Harmonics & Flicker met not met N/A A2 A4 : Emission met not met N/A A5 : Test Setup Drawing(s) Report no. ETLE100104.03, Page A1 of A5

Interference Power Test Data EMC TEST REPORT EUT Type : Inmotion Satellite Antenna / WSTA-VM300P (S/N: N/A) Limit apply to : EN 55013 Applicant : WiWORLD CO.,Ltd. Operating Condition : Searching satellite mode Date : January 12, 2010 Result : Passed by 3.40 db Interference Power Tabulated Data Test port Frequency [MHz] Result [db(pw)] Limit [db(pw)] Margin [db] Quasi-peak Average Quasi-peak Average Quasi-peak Average Antenna Receiver DC Input NOTES : 37.084 33.10 26.60 46.90 36.90 13.80 10.30 200.002 41.80 40.80 54.20 44.20 12.40 3.40 32.154 34.90 31.10 46.30 36.30 11.40 5.20 42.614 34.40 30.40 47.50 37.50 13.10 7.10 32.959 32.50 26.80 45.40 35.40 12.90 8.60 37.894 29.70 23.60 46.00 36.00 16.30 12.40 1. * H : HOT Line, **N : Neutral Line 2. Margin value = Limit Result 3. All conditions were investigated and the worst-case emissions are reported. 4. If the limits for the average detector are met when using the quasi-peak detector, then the limits for the measurements with the average detector are considered to be met. Hyung Min, Choi Test Engineer Report no. ETLE100104.03, Page A2 of A5

Interference Power Test port : Antenna Limit : Quasi-peak Average [db(pw)] [db(μv)] 70 60 50 Level 40 30 20 10 0 30.000 50.000 100.000 200.000 300.000 Frequency [MHz] Test port : Receiver [db(pw)] [db(μv)] 70 60 50 Level 40 30 20 10 0 30.000 50.000 100.000 200.000 300.000 Frequency [MHz] Quasi-peak Average Report no. ETLE100104.03, Page A3 of A5

Interference Power Test port : DC Input Limit : Quasi-peak Average [db(pw)] [db(μv)] 80 70 60 50 Level 40 30 20 10 0 30.000 50.000 100.000 200.000 300.000 Frequency [MHz] Quasi-peak Average Report no. ETLE100104.03, Page A4 of A5

The setup drawing(s) DC Power Supply EUT (Antenna) EUT (Receiver) : Signal line : AC Power line : DC Power line Report no. ETLE100104.03, Page A5 of A5

Attachment B List of Test Equipment Report no. ETLE100104.03, Page B1 of B2

Emission Test Equipments Description Model Number Manufacturer Serial Number Cal Due Date EMI TEST Receiver ESPI3 R & S 100478 10.09.18 Absorbing Clamp MDS-21 R & S 831676/013 10.03.31 Immunity Test Equipments Description Model Number Manufacturer Serial Number Cal Due Date Electrostatic Discharge Simulator & ESD Gun Hybrid Log Periodic Antenna ESS-2002 & TC-815R NOISEKEN ESS0827924 & ESS0827983 10.09.18 HLP-2603 EMC Automation 030004 N/A Signal Generator 2025 IFR 202301/933 10.04.03 Function generator 33220A Agilent MY44008103 10.04.03 Amplifier GRF5066 OPHIR 1011 N/A Field Monitoring Controller SI-300 EMC Automation 20700 N/A Power Meter 437B H.P 3125U24502 10.09.18 Power Sensor 8482A H.P 2652A17488 10.09.18 Dual Directional Coupler C5571 Werlatone 7860 10.04.03 Switch Module RSM-02 EMC Automation 20002 N/A Report no. ETLE100104.03, Page B2 of B2

Attachment C Constructional Photographs of Equipment Under Test (EUT) Report no. ETLE100104.03, Page C1 of C8

Front view of EUT (Antenna) Rear View of EUT (Antenna) Report no. ETLE100104.03, Page C2 of C8

Front view of EUT (Receiver) Rear View of EUT (Receiver) Report no. ETLE100104.03, Page C3 of C8

CE Marking Information Note. The CE marking must have a height of at least 5 mm. If the CE marking is reduced or enlarged the proportions given in the above graduated drawing must be respected. Report no. ETLE100104.03, Page C4 of C8

Internal of EUT (Antenna) #1 Report no. ETLE100104.03, Page C5 of C8

Internal of EUT (Antenna) #2-1 Report no. ETLE100104.03, Page C6 of C8

Internal of EUT (Antenna) #2-2 Report no. ETLE100104.03, Page C7 of C8

Internal of EUT (Receiver) Report no. ETLE100104.03, Page C8 of C8

Attachment D Constructional Data Form and Product Information Form(s) Report no. ETLE100104.03, Page D1 of D2

CONSTRUCTION DATAFORM FOR EMC TESTING Applicant Address Factory Address : WiWORLD CO.,Ltd. : 585-1 Yongsan-dong, Yuseong-gu, Daejeon 305-500 Korea : WiWORLD CO.,Ltd. : 585-1 Yongsan-dong, Yuseong-gu, Daejeon 305-500 Korea Type : Inmotion Satellite Antenna Rated voltage : DC 12 V Serial No. : NONE Rated input power : Protection type : Protection class : Configuration of equipment: Rev. : Rev. : Rev. : Rev. : Source of interference : Internal frequency : Noise suppression components : Measures for electromagnetic shielding : Place of issue date Seal and signature of applicant If applicable, if necessary complete overleaf Report no. ETLE100104.03, Page D2 of D2 End of Test Report