80i-600A AC Current Probe

Similar documents
36 AC/DC True RMS. Clamp Meter. P Read First: Safety Information

SureGrip TM. XWWarning

742A Series Resistance Standards

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

12B/18 MultiMeter Instruction Sheet

374/375/376 Clamp Meter

374/375/376 Clamp Meter

374 FC/375 FC/376 FC Clamp Meter

Electrical Multimeter

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

374/375/376. Calibration Manual. Clamp Meter

323/324/325 Clamp Meter

80i-110s. AC/DC Current Probe Instructions. Introduction

5520A. Service Manual. PQ Option

HART Mode. Users Guide. July Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies.

712C. Users Manual. RTD Calibrator

User Guide. Digital AC/DC Clamp Meter Model 38394

User s Guide. Digital AC/DC Clamp Meter Model 38394

1507/1503. Insulation Testers. Users Manual

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

51-54 Series II. Thermometer

T+ and T+ PRO Electrical Tester

Glass Electrode Meter

16 Multimeter with Temperature

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

16 Multimeter with Temperature

Models 110, 111 & 112

T6-1000/T Service Information. Electrical Tester

80i-110s AC/DC CURRENT PROBE

Circuit Breaker Finder

5520A. Operators Manual. PQ Option

Broadband Current Probe Series Operation Manual

True RMS AC / DC Power Clamp Meter Model

200Amp AC Clamp Meter + NCV Model MA250

F R F R G

PCO-7114 Laser Diode Driver Module Operation Manual

DMM8900 SERIES USERS MANUAL

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

ELECTROSURGICAL UNIT ANALYZER

DM-46 Instruction Manual

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

Insulation Tester. Users Manual

Agilent 1146A AC/DC Oscilloscope Current Probe

1000A AC DIGITAL CLAMPMETER MODEL KM 3060

Questions? Call Toll-Free

Model 935A Current Source Operation Manual

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

Broadband Current Probe Series Operation Manual

VT1586A Rack Mount Terminal Panel Installation and User s Manual

MICROTOOLS MICRONETBLINK KIT

netzerotools.com 374/375/376 Users Manual Clamp Meter

Current Probe Fixture Instruction Manual

EA3012 TRANSCONDUCTANCE AMPLIFIER OPERATION MANUAL

INSTRUMENTS, INC. Model 2960AX Disciplined Quartz Frequency Standard 2960AX. Section Page Contents

DL102 Counter Loop Amplifier

AM-500 Autoranging Mulitmeter. AM-500-EUR Digital Multimeter. Users Manual

Instruction Manual ICM 135R Electrical Clamp Multimeter EN FR IT DE ES

312, 316, 318. Clamp Meter. Users Manual

High Performance Microphone Splitter. Artcessories. User's Manual

Pro. SimpliFiber. Getting Started Guide. Optical Power Meter and Fiber Test Kits

UNCONTROLLED WHEN PRINTED

1523, 1524 Thermometer Readout User s Guide

PHASE ROTATION METER. Operating and Instruction Manual. a n d A C C E S S O R I E S

User s Guide. Model MA A AC Mini Clamp-on Meter

Bulk Current Injection Probe Test Procedure

Directed Energy, Inc Oakridge Dr., Suite 100, Fort Collins, CO

DA560D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Pen Multimeter. Model

712B. Users Manual. RTD Calibrator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

2000 A AC TRUE RMS DIGITAL CLAMP METER WITH NON-CONTACT EF-DETECTION

HHMA2 DC / TRUE RMS AC NON-CONTACT MILLIAMMETER

HP 86290B RF PLUG-IN GHz HEWLETT PACKARD

15B & 17B. Multimeters. Users Manual

INSTRUCTION MANUAL LKG

MODEL 3810/2 Line Impedance Stabilization Network

DA604D DA954D DA501D DA801D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

This manual should be read in its entirety prior to operation of the TS200 Test Set Page 2 of 9

User s Manual. Ground Resistance Clamp On Tester MODEL

Preliminary Data Sheet!

T5-600/T Electrical Tester

712B/714B. Calibration Manual. RTD/Thermocouple Calibrator

SSR V-12C. Industrial Switching Applications: Hellroaring Technologies, inc. P.O. Box 1521, Polson, Montana 59860

Model 935A. Dual Tone Sender INSTRUCTION MANUAL

HELLROARING TECHNOLOGIES, INC. P.O. BOX 1521 POLSON, MT

1630-2/ FC. Calibration Manual. Earth Ground Clamp

PDB4. Four Channel Passive Direct Box USER'S GUIDE

P.O. BOX 1521 POLSON, MT SSR V-12C

DA6002D-DA10004D. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

1587/1577 Insulation Multimeters

POWER SERIES Plus. Volt / Amp / Hertz. Digital Switchboard Meter. User s Manual IM2493VAF-3

Line 6 L I M I T E D R E F URBISH E D (B-ST O C K) W A RR ANT Y

Two Element Phased Vertical Array System

N2790A Differential Voltage Probe

Wilcom MODEL T336B CIRCUIT TEST SET. Operating Instructions

Grid Radar Installation Manual

DIGITAL CLAMPMETER MODEL

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

15B & 17B. Users Manual. Multimeters

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

Transcription:

x Instruction Sheet 80i-600A AC Current Probe INTRODUCTION The Model 80i-600A is a clamp-on ac current probe designed to extend the current measuring capability of an ac current meter to 600 amperes. A clamp-on, 1000-turn coil designed into the probe allows measurements to be made without breaking the circuit under test. The coil serves as the secondary of a current transformer. The current carrying conductor being measured serves as the primary. Because of a high efficiency, quadrature type of winding used, wire size and the position of the wire within the probe jaws does not effect accuracy. SPECIFICATIONS Input Current Range: 1A to 600A Output: 1 milliamp per ampere of input current (1mA/A) Accuracy: ±2% of reading, 50 Hz to 1 khz ±3% of reading (typical), 30 Hz to 50 Hz or 1 khz to 10 khz. Working Voltage: 750V ac rms maximum Maximum Conductor Size: 50.8 mm (2 inch.) Shunt (load) Resistance: less than 12 Ω at multimeter input to maintain specified accuracy Typical Bandwidth: -10% at 10 Hz and 50 khz (1A, 400 Hz reference, excludes multimeter response) Usable Current Range: 0.1A to 2000A, 5 seconds maximum above 600A Safety: Protection Class Class II as defined in IEC 348 and ANSI C39.5 MULTIMETER COMPATIBILITY The 80i-600A is compatible with any multimeter capable of reading ac current equal to 1/1000 of the current to be measured. To take full advantage of the probe's accuracy, a multimeter ac current accuracy of ±0.75% or better is recommended. A voltmeter fitted with an external shunt will qualify as a suitable current meter. However, to ensure the probe's accuracy, the shunt (or multimeter input resistance in ac current) should be less than 12 Ω. This requirement is met on Fluke DMM's when using a current range of 20 ma or greater. When making a measurement, the current-carrying conductor is not broken, and remains electrically isolated from the current meter input terminals. As a result, the current meter's INPUT LO or COM terminal may be either floated (isolated) or grounded. P/N 944025 June 1994 1994 Fluke Corporation. All rights reserved. Printed in U.S.A. All product names are trademarks of their respective companies.

METER READINGS When the 80i-600A is connected to a compatible current meter and clamped around a single current-carrying conductor, the meter reading will be one 1000th of the actual current in the conductor. For example, a 5-ampere (A) input current will be transformed into a 5 milliampere (ma) output current (see Figure 1). When measuring current in an ac line cord, the jaws should be clamped around only one conductor (the black or hot wire in a three wire cord). If the jaws are clamped around both current carrying conductors, the currents will cancel and produce a zero reading. If the probe is clamped around two wires carrying current in the same direction, the sum will be read. Reversing one of the wires causes the difference to be read. LOW-LEVEL CURRENT MEASUREMENTS The 80i-600A AC Current Probe is specified to measure currents of 1A or greater. Currents less than 1A will produce meter readings that are below the true value. Low-level currents can be measured by looping the input wire through the jaws so that the sum of the current through the jaws is greater than 1A. The actual current can then be calculated by dividing the meter reading by the number of turns looped through the jaws. For example, to measure a current of 400 ma (0.4A), form a 10-turn loop and clamp the jaws of the 80i-600A around all 10 turns. The meter reading will be 4 ma, which corresponds to a primary current of 4A. The actual current in the conductor is 4A divided by 10-turns, or 400 ma. 320A 320 ma AC AC CURRENT FUNCTION A SINGLE CURRENT-CARRYING CONDUCTOR 300 ma RANGE 300mA COM RED BLACK Figure 1. Typical 80I-600A Using a Typical Meter NOTE The range selection on the meter should always be 20 ma or greater (12 Ω shunt or lower). Lower ranges with higher shunt values will cause reading errors.

OPERATION 1. Connect the 80i-600A output connectors between the common and the appropriate current input jack of a suitable meter, then switch the meter on. NOTE Refer to Table 1 to determine the appropriate input jack and proper function setting for use with a Fluke handheld DMM. Use Table 2 for use with other typical DMMs. 2. Select a 20 ma ac or greater current range. 3. Clamp the probe around the current-carrying conductor to be measured (see Figure 1). Make sure the probe jaws are tightly closed around the conductor. NOTE Wire size and the position of the wire within the probe jaws does not affect measurement accuracy. 4. Multimeter readings displayed in milliamps (ma) can be read directly as amperes of conductor current. Readings displayed in amperes (A) must be multiplied times 1000 to obtain the amperes of conductor current. MAINTENANCE Performance Test Verify the probe accuracy by measuring the output of a 20A (±0.2%), 60 Hz current source (Fluke 5100B and 5220A or equivalent). When used with a compatible DMM with ± 0.75% or better ac current accuracy (Fluke 8060A or equivalent), the probe should measure 20.00A ± 0.40A (20.00 ma, ± 0.40 ma). There are no calibration adjustments in the 80i-600A. Cleaning Use a soft cloth dampened in a mild solution of detergent and water to clean the 80i-600A. Do not use solvents. A light coating of dripless oil on the jaw surfaces will prevent corrosion.

Table 1. Clamp/Meter Setup Guide FLUKE MODEL INPUT JACK (for red lead) FUNCTION 21 300 ma (limited to 320A) 23, 21 Series II, 23 Series II 300mA 10A for > 320A 25,27 maµa A for > 320A ma/ 75,77, 75 Series II, 77 Series II 300mA 10A for >320A 29,79 Series II 40 ma 10A for 40A 83,85,87 maµa A for > 400A ma/ 8060A,8062A A AC~, A* 8020A,8020B, 8021B,8022A, 8024A,8024B, 8026B ma AC~, ma* * 20 ma range for up to 20A 200 ma range for up to 200A 2000 ma range for up to 600A Table 2. Typical DMM Range Selection Guide INPUT CURRENT RANGE RECOMMENDEDDM M RANGE OR SHUNT EQUIVALENT DISPLAY FOR 3-1/2 DIGIT DMM 1A to 10A 20 ma (10Ω Shunt) 1.00 to 10.00 10A to 200A 200 ma (1Ω Shunt) 10.0 to 200.0 200A to 600A 2000 ma (0.1Ω Shunt) 200 to 600

WARRANTY Fluke Corporation (Fluke) warrants this instrument to be free from defects in material and workmanship under normal use and service for a period of 1 year from date of shipment. Software is warranted to operate in accordance with its programmed instructions on appropriate Fluke products. It is not warranted to be error free. This warranty extends only to the original purchaser and shall not apply to fuses, computer media, batteries or any product which, in Fluke s sole opinion, has been subject to misuse, alteration, abuse or abnormal conditions of operating or handling. Fluke s obligation under this warranty is limited to repair or replacement of a product which is returned to an authorized service center within the warranty period and is determined, upon examination by Fluke, to be defective, if Fluke determines that the defect or malfunction has been caused by misuse, alteration, abuse or abnormal conditions of operation or handling, Fluke will repair the product and bill the purchaser for the reasonable cost of repair. If the product is not covered by this warranty, Fluke will, if requested by purchaser, submit an estimate of the repair costs before work is started. To obtain repair service under this warranty purchaser must forward the product, (transportation prepaid) and a description of the malfunction to the nearest Fluke Service Center. The product shall be repaired at the Service Center or at the factory, at Fluke s option, and returned to purchaser, transportation prepaid. The product should be shipped in the original packaging carton or a rigid container padded with at least four inches of shock absorbing material. FLUKE ASSUMES NO RISK FOR IN- TRANSIT DAMAGE. THE FOREGOING WARRANTY IS PURCHASER S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY, OR FITNESS FOR ANY PARTICULAR PURPOSE OR USE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR LOSS WHETHER IN CONTRACT, TORT, OR OTHERWISE. CLAIMS Immediately upon arrival, purchaser shall check the packing container against the enclosed packing list and shall, within (30) days of arrival, give Fluke notice of shortages or any nonconformity with the terms of the order, if purchaser fails to give notice, the delivery shall be deemed to conform with the terms of the order. The purchaser assumes all risk of loss or damage to instruments upon delivery by Fluke to the carrier. If an instrument is damaged in transit, PURCHASER MUST FILE ALL CLAIMS FOR DAMAGE WITH THE CARRIER to obtain compensation. Upon request by purchaser, Fluke will submit an estimate of the cost to repair shipment damage. Fluke will be happy to answer all questions to enhance the use of this instrument. Please address your requests or correspondence to: FLUKE CORPORATION, P.O. BOX 9090, EVERETT, WA 98206-9090, ATTENTION: Sales Department. For European Customers: Fluke Europe B.V., P.O. Box 1186, 5602 B.D., Eindhoven, The Netherlands.

For application or operation assistance, or information on Fluke products, call: USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-678-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 Or, visit Fluke s Web site at www.fluke.com. Address correspondence to: Fluke Corporation Fluke EuropeB.V. P.O. Box 9090 P.O. Box 1186 Everett, WA 98206-9090 5602 BD Eindhoven, USA The Netherlands