Tel.: 0755-22678966 Email: service@huayuan-elec.com Add.: 1F No1 Building, Hong Hui Industrial Park, Liu Xian Second Road, Bao an istrict, Shenzhen, Guangdong, China G1 serials General Vector Inverter
G1 series general vector inverter is the first technology advantages of the European and generation of general inverters which is developed Japanese inverters. Comprehensive protection b y H u a Yu a n E l e c t r i c C o., L t d i n d e p e n d e n t l y, function and the really independent air duct design Perfect I / O interface covering the full power range of 0.75K-500K. The give the product good reliability and safety, excellent product is designed in conjunction with design EMC performance, rich and easy-to-use product Modular software design to support customization and expansion concept of high reliability, super performance, functions, advanced control algorithms and strict complete functions, easy to use, strong adaptability crystal control make G1 series a general cost- to the environment, combined with the application effective inverter. Va r i o u s s e l e c t i o n Bottom installation support for the whole series For 3.7k and above, middle installation with flange can be chosen Optional local or remote keyboard Reliable protection characteristics of domestic inverters and the New topological framework Three-phase current detection Superior performance Machine tools, textile, packaging, chemical industry, transmission, fans and pumps, ceramic industry, woodworking machine Support V / F control, open-loop vector control Excellent torque characteristics as well as acceleration and deceleration performance Easy to use User - defined parameter set Fan maintenance without disassembling Modular control components Small volume Textile Machine tools Small size, saving installation space Independent air duct design Independent air duct design, achieving electrical isolation and pollutant isolation 01 Petrifaction Independent air duct Packaging Fan 02
xternal C reactor, K and above + +1 QF Three-phase input power supply External braking resistor, 22 K and above PB L1/R T1/U L2/S T2/V L3/T T3/ PE Electromotor M PE Ground terminal Forward running Forward inching Fault resetting Multi-function digital input Multifunction output terminal 2 Open loop vector control, 0.5 Hz with 150% load, low frequency, large torque, meeting the site requirement on high torque output TB1 I2 TC1 I3 Multifunction output terminal 1 Open loop vector control. 50 Hz with 100% load, 0.1s acceleration time, fast torque dynamic response, high accuracy of speed control TA1 I1 I4 SE TA 2 SK Multifunction relay output 0 VAC, less than 3A VC, more than 3A TB2 I5 J11 TC2 Backward I6 Reserved I7 24 V GN Programmable digital output If open, 01 provides 24 V / 10 ma power supply 01 Shielded wire terminal GN 10V 0-10 V/0-20 ma Analog input 0-10 V AI1 0-10 V/0-20 ma V V I J8 J9 I A01 AI2 A02 GN GN 0-10 V Analog output A RS485 B RJ 45 External keyboard interface Note: Jumper J8: AI1 input 0-10V, 0-20mA can be chosen Jumper J9: A01 Output 0-10V, 0-20 ma can be chosen J11: I input drain, source can be chosen Open loop vector control. 5 Hz with 100% load, sudden load and unload, torque and speed waveforms, rapid response to impact load 03 Open loop vector control. 50 Hz with 100% load, forward and reverse switching torque, current, speed waveform Advanced vector control algorithm and dead-zone protection, smooth current and steady speed during switching, steady speed, ensuring the smooth operation of system 04
项目 Item 规格 Specifications Item Specifications Auto voltage regulation (AVR) hen the input voltage deviates from the rated voltage, the function can be used to regulate the output voltage, so that AVR should be activated under normal circumstance, especially when the input voltage is higher than the rated voltage Input Rated voltage, frequency 4T:380 V,50/60 Hz Allowable voltage range Range: 320-528V; degree of unbalance : <3%, frequency range: 47-63 Hz Output voltage 0 - INPUT Basic functions Auto current limiting hen the input current reaches the auto current limiting, the function can adjust output frequency of inverter, so that the current will not be over the auto current limiting. This function will farthest avoid over current fault of inverter to keep the inverter uninterruptedly working. output Output frequency Overload capacity (160K below) Control mode 0-1500 Hz G:150% - 60s;180% - 3s;200% - 0.5s P:120% - 60s;150% - 3s;180% - 0.5s V/F control, open-loop vector control (SCV) Overvoltage stalling control MOBUS communication Binding function Input terminal drain/source section Used to control the voltage of C bus during the running of the inverter to prevent overvoltage of C bus Standard MOBUS communication protocol for rapid communication with peripherals Operation command channel is bound with power input channel, without parameter setting Through jumper terminal, drain or source can be chosen for I1- I7 to meet the needs in different cases Starting torque Range of speed regulation 0.5 Hz 150%(SVC) 1:200(SVC) 1:100(V/F) Special functions Multi AI curve correction ouble motor parameters Up to 4 points can be chosen to set AI curve for flexible and convenient curve correction Two sets of parameters of asynchronous inverters are stored to achieve the switching function between two different motors Steady speed precision Speed fluctuation ±0.6%(SVC) ±0.6%(SVC) Virtual I / O port User customized parameter set 5 virtual IO ports make complex logic control applications convenient The customer can choose the required parameter set, sent to P14 as the custom parameter for daily view and modification Control features Torque response 40 ms (SVC) Low frequency mode High frequency mode Command source channel Frequency source channel Three modes, keyboard setting, external terminal setting, communication setting, switchable igital setting, analog setting, pulse setting, multi-speed, communication setting etc. for selection Frequency precision igital setting: 0.01 Hz Analog setting: Max frequency 0.2% igital setting: 0.1 Hz Analog setting: Max frequency 0.2% 7 digital input terminals, I1-I7, drain and source input can be chosen I7 can be used as a high speed pulse input, supporting 12 V and 24 V level, the maximum frequency of 50 KHz Input terminal Frequency resolution Modulation system 0.01 Hz SVPM 0.1 Hz Operation and running 2 analog input terminals AI1:0 10V or 0-20 ma can be chosen: AI2:0 10V can be chosen through parameter setting, 2 analog input terminals AI both can be used as digital input terminal I Carrier frequency 0.5-16 KHz, based on model 1 programmable switch output, the output level is 24 V when open Auto carrier adjustment hen the function is activated, the inverter can automatically adjust carrier frequency based on the temperature inside. Output terminal 2 programmable relay output, 0 VAC/3 A VC/ 3A Torque boost In V/F control mode, the torque can increase by 0.1% -% manually. Torque curve 0: User customized V/F curve; 1: 2 power curve; 2: 1.7 power curve; 3: 1.2 power curve Acceleration and deceleration time 0-6500.0 s, linear or sigmoid curve acceleration and deceleration mode, optional 4 groups of acceleration and deceleration time Frequency range: 0.00-50.00 Hz Inching function Acceleration and deceleration time: 0.1 60.0 s Basic functions Simple PLC, multi speeds Internal PI akeup Torque limit C brake Optional interval time: 0.0 100.0s Up to 16 speeds can be achieved through built-in PLC function and control terminal function To achieve close-loop control Process PI has sleep and wakeup function The torque is limited during speed control to prevent frequent over-current alarm Starting frequency: 0.00 max set frequency C braking time: 0.01.00s (0.0: not activated) 1 Serial number 2 Voltage level 2S: Single phase 220 V 2T: three phase 220 V 4T: three phase 380 V G1-4T 0040 G/P 1 2 3 4 3 Power level 0007:0.75 K 0015:1.5 K 0150:15 K 4 Motor type G: General P : Fan and pump C braking current: 0.0 100% rated current of the inverter 05 06
8 TECHNICAL PARAMETERS 10 INSTALLATION IMENSIONS Type Rated volume (kva) General load (G-type) Rated output current (A) Motor type (k) Fan and pump load (P-type) Rated volume Rated output Motor type (kva) (A) (k) G1-4T0007G 1.7 2.5 0.75 G1-4T0015G 2.6 4 1.5 G1-4T0022G 3.4 5.2 2.2 G1-4T0040G/0055P 5.9 9 4 8.6 13 5.5 G1-4T0055G/0075P 8.6 13 5.5 11.2 17 7.5 Frame A Frame B Frame C G1-4T0075G/0110P G1-4T0110G/0150P 11.2 16.5 17 7.5 11 16.5 21 32 11 15 G1-4T0150G/0185P 21 32 15 38 18.5 G1-4T0185G/0220P 38 18.5 45 22 G1-4T0220G/00P 45 22 40 60 G1-4T00G/0370P 40 60 50 75 37 G1-4T0370G/0450P 50 75 37 60 90 45 Frame Frame F 9 KEYBOAR INSTALLATION SIZE Frame A B C F imensions: x H x 97 x 167 x 144 143 x 235 x 160.2 161.5 x 260 x 173.7 170 x 320 x 190.5 235 x 390 x 198.6 Hole size: x H1 Screw size 86 x 156 132 x 224 150.5 x 249 151 x 3.5 214 x 373 M5 M5 M5 M5 M5 Inverter type G1-4T0007G G1-4T0015G G1-4T0022G G1-4T0040G/0055P G1-4T0055G/0075P G1-4T0075G/0110P G1-4T0110G/0150P G1-4T0150G/0185P G1-4T00G/0370P G1-4T0370G/0450P Unit:(mm) Unit: (mm) 07 08
Shijiazhuang Beijing Tianjing Jinan uxi Suzhou Hangzhou Taizhou Foshan Shenzhen Established In process Tianjin Office Tel: 0755-23227099 Fax: 0755-296461 Room 5-1-201, Qingfeng Park, the South of est Jinyang Road, in the outer ring, Zhongbei Town, Tianjin City Suzhou Office Tel: 0755-23227099 Fax: 0755-296461 Room 6-104, Yangguang Pavilion, No. 76, Chenghu Road, uzhong istrict, Suzhou City Hangzhou Office Tel: 0755-23227099 Fax: 0755-296461 Room 1202, Unit 2, Building 9, Lanqiaoming Garden, Jianggan istrict, Hangzhou City, Zhejiang Province Official website of HuaYuan 09