TT230 Series Thin Transmitters

Similar documents
User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

250T Loop-Powered (2-wire) Transmitter 250T. Input. Isolation. 350T DC-Powered (3-wire) Transmitter 350T. Input. Isolation

Isolated Transmitters: 600T Series

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series

OPTITEMP TT 20 Technical Datasheet

Two-Wire Programmable Transmitter for:

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

FC Series Signal Conditioners

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

Isolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Temperature Transmitters - DIN Rail Mounted

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER

FC-33, DC SELECTABLE SIGNAL CONDITIONER

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Multifunction Intelligent 4-wire Isolated Signal Conditioner

USER S MANUAL. USB Programmable, DIN Rail Mount Thin Temperature Transmitter Model TT RTD Input, Two-Wire Transmitter

Temperature Transmitters - Head Mounted

User's Manual: Series 250T AC Current Input (External Sensor) Two-Wire Transmitters

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

Temperature transmitter itemp PCP DIN rail TMT 121

Assembly. Front view. Parametrization interface. Power Bus

S200 I/O System Units

Universal Intelligent 2-wire In-head Transmitters

ISOLATED 4-20 ma TRANSMITTERS

Introduction ISOLATED SIGNAL CONDITIONING can significantly increase

Industrial Modbus I/O Modules

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

CompactLogix 5370 L3 Control System

itemp HART DIN rail TMT112

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

EX1000 Series EX1000A EX1000A-TC EX1016A EX1032A EX1048A EX10SC EX1000A-TCDC RELIABLE DATA FIRST TIME EVERY TIME.

Universal Intelligent 2-wire DIN Rail Transmitters

ATA-2001 Analog LVDT/RVDT Signal Conditioner with digital calibration

SPT. Description. Features. Site-Programmable, Isolated Temperature Transmitter

SEM210 SEM210X UNIVERSAL TEMPERATURE TRANSMITTER

7SD/7SH/7SM Temperature Controllers

0 2 1 â Ó. itemp HART TMT182. Technical Information

User's Manual: Series 250T Model 250T Frequency Input Two-Wire Transmitters

Modicon Momentum automation platform 0

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

Correlation of Voltage and Temperature Measurement

SLC 500 RTD/Resistance Input Modules

DRG-SC Series Signal Conditioners

TxBlock-USB Transmitter

Miniature Temptran RTD Transmitters

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Isolated Module TRPxxxxxP 系列产品

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Each click of a dial opens a doorway to precision. 2553A. Precision DC Calibrator. Bulletin 2553A-01EN

SITRANS T measuring instruments for temperature

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

Transmitter. Configuration Code TM01 Series 440 Programmable RTD Temperature Transmitter. Application Areas. Features and Benefits

CALYS 50. Field multifunction calibrator for basic use

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

2002-ALM USER MANUAL

HART Compatible Intelligent 2-wire DIN Rail Transmitters

High-precision process calibrator Model CED7000

PACSystems* RX3i. Isolated RTD Input Module, 8 Channels, IC695ALG508-CA. Module Features. GFK-2501C November 2012

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Miniature resistance thermometer Model TR33, thread-mounted

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

PD30ETD10xxSA. Photoelectrics, Diffuse reflective. Main features. Description

TT2780. Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H

5069 Compact I/O Modules Specifications

Portable Multi-Channel Recorder Model DAS240-BAT

ATA-2001 Analog LVDT/RVDT Signal Conditioner with digital calibration

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Modbus I/O. RS-485 to 3-wire Universal 50W Power Supply

C1901 Single Pen Circular Chart Recorder. C1901 a rugged, reliable recorder for all single channel recording applications

0 2 1 â Ó. itemp HART TMT182. Technical Information

TECHNICAL DATASHEET #TDAX022420

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

Resistance thermometer Model TR31, miniature design

Additel 875 Series Dry Well Calibrators

Universal Intelligent 2-wire DIN Rail Transmitters

Nuclear Qualified Weed Instrument Model N7030 RTD and N7040 Thermocouple Analog Temperature Transmitter

Part Numbers. SNAP-AIARMS-i SNAP-AIARMS-i-FM* SNAP-AIVRMS-i SNAP-AIVRMS-i-FM* SNAP-AIMA-i. SNAP-AIMA-iSRC SNAP-AIMA-iSRC-FM* SNAP-AIMA2-i

MODEL: R30US4. Remote I/O R30 Series

Isolators A3/1.

MODEL AT-10 ANALOG TRANSMITTER

Temperature Measurement

Temperature Measurement

JUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program

Ouput Loop Powered Products Section C

Transcription:

M O N I T O R I N G & O N T R O L S O L U T I O N S DIN-Rail Mount TT230 Series Thin Transmitters USB-onfigured Slim design Space-Saving 2/3-Wire Isolated Transmitters 8400-72e

Depend on Acromag Experience counts: especially when you are selecting an I/O partner. And with 0 years of I/O experience, Acromag can help you to improve reliability, increase productivity and reduce your costs. Acromag: The I/O Leader Acromag is a customer-driven manufacturer focused on developing process automation I/O products that provide the best long term value in the industry. ompare and you ll find that Acromag products offer an unmatched balance of price, performance, and features. 0 Years of I/O Experience Acromag has more than 0 years of measurement and control experience. Since 1957, we have delivered nearly a million units to thousands of customers around the globe for manufacturing, power, environmental, transportation, and military applications. Top Quality and a 2-Year Warranty We take every measure to guarantee you dependable operation and products that perform at or beyond their specifications. Our state-of-the-art manufacturing and military-grade components add an extra degree of ruggedness. Most products qualify for an extended 2-year warranty. And with ISO 9001/AS9100 certified quality control, you get full confidence. All trademarks are the property of their respective owners. Online Ordering For your convenience, Acromag provides full product documentation and pricing information on our website. You can obtain quotes or even place your order directly on our website. Fast Delivery from Stock Most products can be shipped within 24 hours of receiving your order. Special Services We are happy to accommodate your special requirements and offer the following services: custom product development custom calibration source inspections, quality audits special shipping, documentation protective humiseal coating plastic and stainless steel tagging ertification and Approvals Many Acromag products carry globally recognized agency approvals and safety certifications. E Ethernet conformance UL, cul Modbus conformance ATEX Profibus certification SA IEex Acromag, Incorporated 3075 South Wixom Road Wixom, Michigan 48393 USA 2

Model TT230 Series # Description Thin 2/3-Wire Transmitters Introduction The TT230 series features space-saving thin transmitters and isolators that combine flexibility with rugged housing to withstand harsh industrial environments. Advanced signal processing capabilities, variable range input, and convenient USB programming make these instruments versatile for many applications. TT231 RTD RTD ohms Power (optional) ma TT233 Thermocouple, Millivolt T mv Power (optional) ma TT234 Potentiometer/ Thermistor Pot Therm Power (optional) ma TT235 Isolated RTD RTD ohms Power (optional) ma Various sensor signals (by model) Output 4-20mA current (sink or source) Power Loop-power (2-wire connection) Local D power source (3-wire connection) Key Features and Benefits Space saving 12.5mm housing 100 ohm Pt RTD; alpha = 379-393 0-900 ohms linear resistance See data sheet TT23 urrent, Millivolt Type J,K,T,R,S,E,B,N thermocouple ±100mV See data sheet TT237 Low-Voltage 100-100K ohms from potentiometer/slidewire 2K - 30K ohms thermistor ustom 100-1M ohms See data sheet TT238 High-Voltage 100, 200, 500, or 1000 ohm Pt RTD; 120 ohm Ni RTD; 10 ohm u RTD 0-450 ohms linear resistance See data sheet TT239 Frequency, Pulse Easy setup via USB with Windows configuration software Supports sink and source output in a single model Better than 0.1% accuracy 1500V A isolation Wide operation temperature of -40 to 80 Fast response times Adjustable filtering levels Normal/reverse acting operation (except TT231) ma mv Power (optional) ma 0-20mA, 4-20mA D ±1mA, ±20mA D 0-500mV D ±500mV D 0-20A A V Power (optional) ±1V D ±5V D ±10V D ma V Power (optional) ±15V D ±75V D ±150V D ma KHz Power (optional) 0-100Khz Up to 12V rms amplitude Unipolar or bipolar signals ma Shock and vibration resistant See data sheet See data sheet See data sheet See data sheet Designed for use in hazardous locations UL/cUL lass 1 Division 2 Zone 2 Tel: 248-295-0880 Fax: 248-24-9234 sales@acromag.com www.acromag.com 3075 S Wixom Rd, Wixom, MI 48393 USA 3

Key Features Sink or Source Output Extra output connections support sourced output (3-wire) with local power supply. Loop-powered 4-20mA Power is received from the output loop (2-wire) to provide sinking current output. Simple onfiguration Digital setup and calibration with straightforward Windows (XP, Vista, 7, 8) software via USB. Space Saving A strikingly thin enclosure, at only 12.5mm wide, to easily achieve high-density DIN-rail mounting. Options Rugged Design -40 to 80 Wide ambient temperature operation, shock and vibration-resistant, as well as E and UL/cUL lass 1, Division 2, Zone 2 approved. Tel: 248-295-0880 Fax: 248-24-9234 sales@acromag.com www.acromag.com 3075 S Wixom Rd, Wixom, MI 48393 USA 4

General Operation and Performance Specifications The following specifications are common to all TT230 Series transmitter modules. USB Interface Physical USB onnector USB Data Rate USB Mini-B type socket, 5-pin 12Mbps. USB v1.1 and 2.0 compatible General ase Material General-purpose enclosure designed for mounting on 35mm T-type DIN rail. Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General-purpose NEMA Type 1 enclosure. Output Output Range Accuracy 4 to 20mA D ±0.05% of span typical I/O onnectors Shipping Weight Removable plug-in terminal blocks rated for 12A/250V; AWG #2-12, stranded or solid copper wire. 0.22 kg (0.5 pounds) packed Environmental Operating Temperature Storage Temperature -40 to 80 (-40 to 17 F) -40 to 85 (-40 to 185 F) Dimensions 12.5 (0.50) *in millimeters (inches) TOP VIEW (OUTPUT/POWER) Relative Humidity 5 to 95% non-condensing 114.5 (4.51) Power Requirement 12-32V D D SELV (Safety Extra Low Voltage); 24mA max. Isolation (except model TT231) 1500V A peak. 250V A (354V D) continuous isolation between input and output circuits. Shock and Vibration Immunity Electromagnetic ompatibility (EM) ompliance Vibration: 4g, per IE 008-2-4. Shock: 25g, per IE 008-2-27. Radiated Emissions: BS EN 1000--4, ISPR 1. RFI: BS EN 1000--2, IE 1000-4-3. onducted RFI: BS EN 1000--2, IE 1000-4-. ESD: BS EN 1000--2, IE 1000-4-2. EFT: BS EN 1000--2, IE 1000-4-4. Surge Immunity: BS EN 1000--2, IE 1000-4-5. 99.0 (3.90) Approvals E compliant. UL/cUL listing. Designed for lass I; Division 2; Groups ABD; Zone 2. BOTTOM VIEW (INPUT) TT Series USB Transmitter onnections HOST P RUNNING AROMAG ONFIGURATION SOFTWARE Model USB-ISOLATOR (REOMMENDED) Acromag THE LEADER IN INDUSTRIAL I/O R P ONNET DEVIE ONNET ABLE Model 4001-112 POWER RESET ONNETION ABLE Model 4001-113 Tel: 248-295-0880 Fax: 248-24-9234 sales@acromag.com www.acromag.com 3075 S Wixom Rd, Wixom, MI 48393 USA 5 MODEL TT2XX TRANSMITTER

Module onfiguration Screen shots of Windows-based transmitter configuration software. Using simple pull-down menus and user-input, your transmitter is ready for use in a snap. Tel: 248-295-0880 Fax: 248-24-9234 sales@acromag.com www.acromag.com 3075 S Wixom Rd, Wixom, MI 48393 USA

Accessories onfiguration Software TT230 Series onfiguration Simple to use, whether you need the full software interface package (includes USB isolator and cables) or just the configuration software itself. Acromag makes it easy to get started. Acromag Agility onfig Tool Easy to download, configuation too mobile app for free download at the Google Play Store. TT-SIP Software Interface Package, includes: configuration software D-ROM, USB-Isolator, and two USB cables (4001-112, 4001-113). TT230-onfig/al Factory custom configuration/calibration service for all TT230 models. TT230-ONFIG Free download of TT230 Transmitter onfiguration Software. Mounting Hardware Din-Rail Mounting For your convenience, Acromag offers several mounting accessories to simplify your system installation. Our 19 rack-mount kit provides a clean solution for mounting your I/O modules and a power supply. Or you can buy precut DIN rail strips for mounting on any flat surface. 20RM-1-DIN 19 rack-mount kit with DIN rail. DIN RAIL 3.0 DIN RAIL 1.7 DIN rail strip, Type T, 3 inches (75mm) or 1.7 inches (425mm) Power Supplies Universal Slimline Power Supplies Power Requirement 85 to 24V A or 105 to 370V D Output 5V D, 12V D, or 24V D 10W to 240W PS5R-SB24 Power supply, 15W, 0.5A at 24V D PS5R-SD24 Power supply, 0W, 2.5A at 24V D Visit www.acromag.com for additional models and more information. USB Isolator USB-to-USB Isolator This compact, industrial-grade isolator provides a high-voltage isolation barrier between a computer and a connected USB device; protecting equipment from electrical surges, transient voltage spikes, and ground loop currents. USB-Isolator USB isolator, includes USB cable (Part # 4001-112) for isolator-to-p connection USB ables ables for P-to-USB isolator, USB isolator-totransmitter connections, and mobile device-to- USB isolator-to-transmitter connections. 4001-112 USB able, Type A to Type B, 1 meter 4001-113 USB able, Type A to Mini-B, 1 meter 5028-55 USB able, USB OTG able, inches Tel: 248-295-0880 Fax: 248-24-9234 sales@acromag.com www.acromag.com 3075 S Wixom Rd, Wixom, MI 48393 USA 7

TT231 RTD/resistance input two-wire/three-wire transmitter BOTTOM VIEW (INPUT SIDE) TOP VIEW (OUTPUT SIDE) Platinum RTD or Resistance H 2 4-WIRE 3-WIRE 2-WIRE 1 IN IN 3 4 L 1 2 3 4 5 7 8 Local Power Supply w/ Sourced Output I 5 SINKING 24V D R INPUT LOAD LOAL I ARD 8 SUPPLY 7 USB onfigured SIDE VIEW 99.0 mm (3.90 in.) ADD JUMPER (2-WIRE ONLY) 12.5 mm (0.50 in.) 114.5 mm (4.51 in.) Loop-Powered w/ Sinking Output I P 24VD 5 I DS/PL SOURING RV INPUT ARD 100 ohm Pt RTD or 0-900 ohm input 4-20mA output (sink/source) 12-32V D loop/local power Description The TT231 model is a space-saving two-wire transmitter that converts a 100 ohm Platinum RTD sensor input to a proportional 4-20mA signal. Power is received from the output loop current or a D supply when using a three-wire connection. The transmitter provides sensor excitation plus performs linearization, lead-wire compensation, and lead-break detection. Setup and calibration are fast and easy with a convenient USB connection to your P and Acromag s Windows configuration software. Advanced signal processing capabilities, variable range input, and convenient USB programming make this instrument a very versatile temperature measurement device. These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions. TT230 Series Transmitter onfiguration Software is downloadable (FREE) from www.acromag.com. Windows XP, Vista, 7, & 8 Key Features & Benefits Easy setup and digital calibration via USB with Windows configuration software Flexible RTD or linear resistance input ranges (any 100 ohm Pt RTD with 375-393 alpha) Space-saving 12.5mm (0.5 inch) unit with pluggable terminals for convenient wiring High accuracy, linearity, stability, and reliability Advanced analog signal conditioning ASI eliminates digitization errors Low temperature drift (<80ppm/ ) Supports sink or source output wiring Programmable over/under-range limits Selectable upscale or downscale operation for sensor errors and lead-break detection NAMUR-compliant output loop current Shock (25g) and vibration (4g) resistant Mounts on Type T DIN-rail Wide ambient operation (-40 to 80 ) E compliant. UL/cUL lass 1 Div 2 Zone 2 approvals Bulletin #8400-0f

TT231 RTD/resistance input two-wire/three-wire transmitter Performance Specifications IMPORTANT: To prevent damage or errors from grounded Ps and surges, Acromag strongly recommends use of their USB-ISOLATOR when configuring a TT230 Series transmitter. USB Interface USB onnector USB Mini-B type socket, 5-pin. USB Data Rate 12Mbps. USB v1.1 and 2.0 compatible. USB Transient Protection Transient voltage suppression on power and data lines. USB able Length 5.0 meters maximum. Driver Not required. Uses built-in Human Interface Device (HID) USB drivers of the Windows operating system. Default onfiguration 100Ω Pt RTD, α=0.00385 Ω/Ω/, 0-200 input, 4-20mA output, upscale break detection. onfiguration Two-, three- or four-wire sensor input connections. Ranges 100 ohm Platinum RTD, alpha = 375-393, 385 (default), -50 to 850 (-58 to 152 F). 0 to 900 ohms linear resistance. Programs in, F, or ohmic integer values only. Zero Adjust RTD 3/4 wire: -50, -17.78, or 0 (-58, 0, 32 F). RTD 2 wire: 0 (32 F) fixed. RES: 0 or 100 ohms. Full-Scale Adjust RTD: up to 850 (152 F), 50 (58 F) span minimum. Resistance: up to 900 ohms, 8 ohm span minimum. Excitation urrent 0.5mA, nominal, each ± lead. Lead-Wire ompensation 25 ohms per lead. Lead Break (Sensor Burnout) Detection onfigurable for either upscale or downscale. Filter Bandwidth -3dB at 700Hz, typical, normal mode filter. Output Output Range 4 to 20mA D. Under-scale limit adjustable for 2.1 to 3.mA, nominal. Over-scale limit adjustable for 21 to 30mA, nominal. Output Fault Limits (Sensor Fault) 0.4mA below selected under-scale threshold and 1.0mA above over-scale threshold, typical. Output ompliance Rload = (Vsupply - 8.V) / 0.020A. Rload = 0 to 750 ohms @ 24V D. Output Accuracy Better than ±0.1% of span, typical for spans less than 500. Includes the effects of repeatability, terminal point conformity, and linearization, but does not include sensor error. Ambient Temperature Effect Better than ±0.008% per of input span or ±80ppm/, typical. Includes the combined effects of zero and span drift over temperature. Output Response Time (for step input change) 500µS, typical with 250 ohm load (to reach 98% of final output value). Environmental Operating temperature -40 to 80 (-40 to 17 F). Storage temperature -40 to 85 (-40 to 185 F). Relative humidity 5 to 95% non-condensing. Power Requirement 9-32V D SELV (Safety Extra Low Voltage), 30mA max. Shock and Vibration Immunity Vibration: 5g, per IE 008-2-4. Shock: 50g, per IE 008-2-27. Electromagnetic ompatibility (EM) ompliance Radiated Emissions: BS EN 1000--4, ISPR 1. RFI: BS EN 1000--2, IE 1000-4-3. onducted RFI: BS EN 1000--2, IE 1000-4-. ESD: BS EN 1000--2, IE 1000-4-2. EFT: BS EN 1000--2, IE 1000-4-4. Surge Immunity: BS EN 1000--2, IE 1000-4-5. Approvals E compliant. UL/cUL listing. Designed for lass I; Division 2; Groups ABD; Zone 2 Physical General General-purpose enclosure designed for mounting on 35mm T-type DIN rail. ase Material Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General-purpose NEMA Type 1 enclosure. I/O onnectors Removable plug-in terminal blocks rated for 12A/250V; AWG #2-12, stranded or solid copper wire. Dimensions 12.5 x 114.5 x 99.0 mm (0.5 x 4.51 x 3.90 inches). Shipping Weight 0.22 kg (0.5 pounds) packed. Models TT231-000 Transmitter, RTD/resistance input. Services TT230-onfig/al Factory custom configuration/calibration service. Specify input type, input/output zero and full-scale values, filtering, and sensor fault settings on order. Software TT-SIP (recommend one kit per customer) Software Interface Package for Acromag TT Series transmitters. Includes configuration software D-ROM (5040-944), isolator (USB-ISOLATOR) and two USB cables (4001-112, 4001-113). Accessories See www.acromag.com for more information. USB-ISOLATOR USB-to-USB isolator, includes USB cable (4001-112). All trademarks are property of their respective owners. opyright Acromag, Inc. 2015. Data subject to change without notice. Printed in USA 8/2015

TT233 Thermocouple/millivolt input two-wire/three-wire transmitter BOTTOM VIEW (INPUT SIDE) TOP VIEW (OUTPUT SIDE) THERMOOUPLE J, K, T, E, R, S, B, OR N OR MILLIVOLT OPTIONAL EARTH GROUND SHIELDED ABLE OPTIONAL SHIELD GROUND 1 INPUT / 2 G 3 4 S 1 2 3 4 5 7 8 Local Power Supply w/ Sourced Output I 5 SINKING 24V D R INPUT LOAD LOAL I ARD 8 SUPPLY 7 USB onfigured SIDE VIEW 99.0 mm (3.90 in.) 12.5 mm (0.50 in.) 114.5 mm (4.51 in.) Loop-Powered w/ Sinking Output I P 24VD 5 I DS/PL SOURING RV INPUT ARD Universal thermocouple or ±100mV input 4-20mA output (sink/source) 12-32V D loop/local power Description The TT233 model is a space-saving two-wire transmitter that isolates and converts a millivolt or thermocouple sensor input to a proportional 4-20mA control signal. Power is received from the output loop current or a D supply when using a three-wire connection. The transmitter performs thermocouple linearization, coldjunction compensation, and lead-break detection. High-voltage isolation separates the input from the output circuit. Isolation protects from surges, reduces noise, and eliminates ground loop errors. Setup and calibration are fast and easy with a convenient USB connection to your P and Acromag s Windows configuration software. Advanced signal processing capabilities, variable range input, and convenient USB programming make this instrument a very versatile temperature measurement device. These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions. TT230 Series Transmitter onfiguration Software is downloadable (FREE) from www.acromag.com. Windows XP, Vista, 7, & 8 Key Features & Benefits Easy setup and digital calibration via USB with Windows configuration software Universal thermocouple or millivolt input (T Type J, K, T, R, S, E, B, N or ±100mV) Space-saving 12.5mm (0.5 inch) unit with pluggable terminals for convenient wiring High accuracy, linearity, stability, and reliability Low temperature drift (<80ppm/ ) User-selectable filtering (none, low, med., high) Supports sink or source output wiring Supports reverse-acting (inverse) output Selectable upscale or downscale operation for sensor errors and lead-break detection 1500V input isolation NAMUR-compliant output loop current Shock (25g) and vibration (4g) resistant Mounts on Type T DIN-rail Wide ambient operation (-40 to 80 ) E compliant. UL/cUL lass 1 Div 2 Zone 2 approvals TT233 Model software allows you to configure transmitters offline, save the file, and download settings into units later, at your convenience. Bulletin #8400-1f

TT233 Thermocouple input two-wire/three-wire transmitter Performance Specifications IMPORTANT: To prevent damage or errors from grounded Ps and surges, Acromag strongly recommends use of their USB-ISOLATOR when configuring a TT230 Series transmitter. USB Interface USB onnector USB Mini-B type socket, 5-pin. USB Data Rate 12Mbps. USB v1.1 and 2.0 compatible. USB Transient Protection Transient voltage suppression on power and data lines. USB able Length 5.0 meters maximum. Driver Not required. Uses built-in Human Interface Device (HID) USB drivers of the Windows operating system. Default onfiguration/alibration : T J, -210 to 70, high filter, Break: up Output: 4 to 20mA. Ranges and Accuracy Range Accuracy T J T K T T T R T S T E T B T N mv -210 to 70 (-34 to 1400 F) -200 to 1372 (-328 to 2502 F) -20 to 400 (-43 to 752 F) -50 to 178 (-58 to 3214 F) -50 to 178 (-58 to 3214 F) -200 to 1000 (-328 to 1832 F) 20 to 1820 (500 to 3308 F) -230 to 1300 (-382 to 2372 F) -100 to 100mV ±0.5 ±0.5 ±0.5 ±1.0 ±1.0 ±0.5 ±1.0 ±1.0 ±0.1mV Error includes the effects of repeatability, terminal point conformity, and linearization. Does not include J error. Thermocouple Reference (old Junction ompensation) ±0.2 typical, ±0.5 maximum at 25. Ambient Temperature Effect Better than ±80ppm/ (±0.008%/ ). Zero Scaling Adjust 0 to 95% of range, typical. Full Scale Adjust 5 to 100% of full scale range, typical. Lead Break (Sensor Burnout) Detection onfigurable for either upscale (24mA) or downscale (3.3mA) operation. Over-Voltage Protection Bipolar Transient Voltage Suppressers (TVS), 5.V clamp level typical. Resolution Millivolt input: 0.0025% (1 part in 40,000) Thermocouple input: 0.1. Filter Selectable digital filtering settings (none, low, medium, high). Filter Bandwidth Normal mode plus digital filtering within the AD. Bandwidth (-3dB) varies with digital filter setting from 4Hz without filtering to 0.33Hz with high filtering. Noise Rejection (ommon Mode, High Filter) 155dB @ 0Hz, typical with 100 ohm input unbalance. Output Output Range 4 to 20mA D. Output ompliance Rload = (Vsupply - 11V) / 0.020A. Rload = 0 to 50 ohms @ 24V D. Output Response Time (for step input change) Time to reach 98% of final output value (typical) No filtering 104 milliseconds Low filter 380 milliseconds Medium filter 70 milliseconds High filter 90 milliseconds Environmental Operating temperature -40 to 80 (-40 to 17 F). Storage temperature -40 to 85 (-40 to 185 F). Relative humidity 5 to 95% non-condensing. Power Requirement 12-32V D SELV (Safety Extra Low Voltage), 24mA max. Isolation 1500V A peak. 250V A (354V D) continuous isolation between input and output circuits. Shock and Vibration Immunity Vibration: 5g, per IE 008-2-4. Shock: 50g, per IE 008-2-27. Electromagnetic ompatibility (EM) ompliance Radiated Emissions: BS EN 1000--4, ISPR 1. RFI: BS EN 1000--2, IE 1000-4-3. onducted RFI: BS EN 1000--2, IE 1000-4-. ESD: BS EN 1000--2, IE 1000-4-2. EFT: BS EN 1000--2, IE 1000-4-4. Surge Immunity: BS EN 1000--2, IE 1000-4-5. Approvals E compliant. UL/cUL listing. Designed for lass I; Division 2; Groups ABD; Zone 2. Physical General General-purpose enclosure designed for mounting on 35mm T-type DIN rail. ase Material Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General-purpose NEMA Type 1 enclosure. I/O onnectors Removable plug-in terminal blocks rated for 12A/250V; AWG #2-12, stranded or solid copper wire. Dimensions 12.5 x 114.5 x 99.0 mm (0.5 x 4.51 x 3.90 inches). Shipping Weight 0.22 kg (0.5 pounds) packed. Models TT233-000 Transmitter, thermocouple/millivolt input. Services TT230-onfig/al Factory custom configuration/calibration service. Specify input type, input/output zero and full-scale values, filtering, and sensor fault settings on order. Software TT-SIP (recommend one kit per customer) Software Interface Package for Acromag TT Series transmitters. Includes configuration software D-ROM (5040-944), isolator (USB-ISOLATOR) and two USB cables (4001-112, 4001-113). Accessories See www.acromag.com for more information. USB-ISOLATOR USB-to-USB isolator, includes USB cable (4001-112). All trademarks are property of their respective owners. opyright Acromag, Inc. 2015. Data subject to change without notice. Printed in USA 8/2015

TT234 Potentiometer / thermistor input two-wire transmitter BOTTOM VIEW (INPUT SIDE) TOP VIEW (OUTPUT SIDE) Resistance POT/SLIDEWIRE MIN MAX RHEOSTAT THERMISTOR 1 2 3 W H 4 1 2 3 4 5 7 8 Local Power Supply w/ Sourced Output I 5 SINKING 24V D R INPUT LOAD LOAL I ARD 8 SUPPLY 7 USB onfigured SIDE VIEW 99.0 mm (3.90 in.) 12.5 mm (0.50 in.) 114.5 mm (4.51 in.) Loop-Powered w/ Sinking Output I P 24VD 5 I DS/PL SOURING RV INPUT ARD Potentiometer/slidewire, thermistor input 4-20mA output (sink/source) 12-32V D loop/local power Description The TT234 model is a space-saving two-wire transmitter that isolates and converts a resistive sensor input to a proportional 4-20mA signal. Power is received from the output loop current or a D supply when using a three-wire connection. The transmitter provides sensor excitation plus performs linearization, lead-wire compensation, and lead-break detection. Setup and calibration are fast and easy with a convenient USB connection to your P and Acromag s Windows configuration software. Advanced signal processing capabilities, variable range input, and convenient USB programming make this instrument a very versatile temperature measurement device. These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions. TT230 Series Transmitter onfiguration Software is downloadable (FREE) from www.acromag.com. Windows XP, Vista, 7, & 8 The Agility onfig Tool is downloadable (FREE) at the Google Play Store For Android Devices only Key Features & Benefits Easy setup and digital calibration via USB with Windows configuration software Interfaces 100-100kΩ potentiometer/slidewire and 100-1MΩ NT thermistor/rheostat inputs ustomizable thermistor linearization table with preset curves for popular resistances 1500V isolation between input/output circuits Space-saving 12.5mm (0.5 inch) unit with pluggable terminals for convenient wiring High accuracy, linearity, stability, and reliability Supports normal or reverse-acting output Supports sink or source output wiring User-selectable filtering (none, low, med., high) Fast response (as low as 11ms) Selectable upscale or downscale operation for sensor errors and lead-break detection NAMUR-compliant output loop current Shock (25g) and vibration (4g) resistant Wide ambient operation (-40 to 80 ) E and UL/cUL lass 1 Div 2 Zone 2 approvals TT234 Model software allows you to configure transmitters offline, save the file, and download into units later, at your convenience. Bulletin #8400-2c

TT234 Potentiometer / thermistor input two-wire transmitter Performance Specifications IMPORTANT: To prevent damage or errors from grounded Ps and surges, Acromag strongly recommends use of their USB-ISOLATOR when configuring a TT230 Series transmitter. USB Interface USB onnector USB Mini-B type socket, 5-pin. USB Data Rate 12Mbps. USB v1.1 and 2.0 compatible. USB Transient Protection Transient voltage suppression on power and data lines. USB able Length 5.0 meters maximum. Driver Not required. Uses built-in Human Interface Device (HID) USB drivers of the Windows operating system. Default onfiguration Pot/slidewire, 0% to 100% input, 4-20mA output, downscale break detect, medium filter. onfiguration Two- or three-wire sensor input connections. User-configurable thermistor linearization table has preset curves for resistances below at 25. Programs in, F, K, or ohmic integer values only. Ranges Type Range Accuracy Potentiometer Rheostat Thermistor 2252Ω Thermistor 2752Ω Thermistor 2795Ω Thermistor 3kΩ Thermistor 5kΩ Thermistor 10kΩ Thermistor 30kΩ ustom thermistor 0 to 100% (100 to 100KΩ) 100 to 1MΩ -40 to 100 (-40 to 212 F) -40 to 100-40 to 100-40 to 100-40 to 100-40 to 100-40 to 100 100 to 1MΩ < ±0.01% of span < ±0.5% of input < ±0.05 (±0.09 F) < ±0.05 (±0.09 F) < ±0.05 (±0.09 F) < ±0.05 (±0.09 F) < ±0.05 (±0.09 F) < ±0.05 (±0.09 F) < ±0.05 (±0.09 F) < ±0.5% of input Scaling Adjust Zero: 0 to 95% of range, typical. Full scale: 5 to 100% of full scale range, typical. Excitation Voltage Thermistor/rheostat: 1.25V D, typical. Potentiometer: 0.3V D, limited to 3.35mA, typical. Lead Break (Sensor Burnout) Detection onfigurable for either upscale or downscale on thermistor or rheostat inputs. Downscale only on potentiometer/slidewire inputs. Output Output Range 4 to 20mA D. Under-range capability 3.5mA. Over-range capability 24mA. Output ompliance Rload = (Vsupply - 11V) / 0.020A. Rload = 0 to 50 ohms @ 24V D. Output DA Resolution 1-bit D/A converter Output Accuracy Better than ±0.05% of span, typical (±0.1% max.) for for nominal input spans. Includes the effects of repeatability, terminal point conformity, and linearization, but does not include sensor error. Ambient Temperature Effect Better than ±0.008% per of input span or ±80ppm/, typical. Includes the combined effects of zero and span drift over temperature. Output Response Time (for step input change) No filter: 11ms. Medium filter: 150ms. Low filter: 40ms. High filter: 1200ms. Environmental Operating temperature -40 to 80 (-40 to 17 F). Storage temperature -40 to 85 (-40 to 185 F). Relative humidity 5 to 95% non-condensing. Power Requirement 12-32V D SELV (Safety Extra Low Voltage), 24mA maximum. Shock and Vibration Immunity Vibration: 4g, per IE 008-2-4. Shock: 25g, per IE 008-2-27. Electromagnetic ompatibility (EM) ompliance Radiated Emissions: BS EN 1000--4, ISPR 1. RFI: BS EN 1000--2, IE 1000-4-3. onducted RFI: BS EN 1000--2, IE 1000-4-. ESD: BS EN 1000--2, IE 1000-4-2. EFT: BS EN 1000--2, IE 1000-4-4. Surge Immunity: BS EN 1000--2, IE 1000-4-5. Approvals E compliant. UL/cUL lass I Div. 2 Zone 2. Physical General General-purpose enclosure designed for mounting on 35mm T-type DIN rail. ase Material Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General-purpose NEMA Type 1 enclosure. I/O onnectors Removable plug-in terminal blocks rated for 12A/250V; AWG #2-12, stranded or solid copper wire. Dimensions 12.5 x 114.5 x 99.0 mm (0.5 x 4.51 x 3.90 inches). Shipping Weight 0.22 kg (0.5 pounds) packed. Models TT234-000 Transmitter, potentiometer/thermistor input Services TT230-onfig/al Factory custom configuration/calibration service. Specify input type, input/output zero and full-scale values, filtering, and sensor fault settings on order. Software TT-SIP (recommend one kit per customer) Software Interface Package for Acromag TT Series transmitters. Includes configuration software D-ROM (5040-944), isolator (USB-ISOLATOR) and two USB cables (4001-112, 4001-113). Accessories See www.acromag.com for more information. USB-ISOLATOR USB-to-USB isolator, includes USB cable (4001-112). All trademarks are property of their respective owners. opyright Acromag, Inc. 2015. Data subject to change without notice. Printed in USA 8/2015

TT235 Isolated RTD/resistance input two-wire transmitter RTD Sensor or Resistance BOTTOM VIEW (INPUT SIDE) TOP VIEW (OUTPUT SIDE) 4-WIRE 1 3 2 3-WIRE 1 3 2 2-WIRE 1 3 2 1 2 3 4 5 7 8 Local Power Supply w/ Sourced Output I 5 SINKING 24V D R INPUT LOAD LOAL I ARD 8 SUPPLY 4 4 4 7 USB onfigured SIDE VIEW 99.0 mm (3.90 in.) 12.5 mm (0.50 in.) 114.5 mm (4.51 in.) Loop-Powered w/ Sinking Output I P 24VD 5 I DS/PL SOURING RV INPUT ARD RTD (Pt, Ni, u) or 0-450 ohm input 4-20mA output (sink/source) 12-32V D loop/local power Description The TT235 model is a space-saving two-wire transmitter that isolates and converts an RTD sensor input to a proportional 4-20mA signal. Power is received from the output loop current or a D supply when using a three-wire connection. The transmitter provides sensor excitation plus performs linearization, lead-wire compensation, and lead-break detection. Setup and calibration are fast and easy with a convenient USB connection to your P and Acromag s Windows configuration software. Advanced signal processing capabilities, variable range input, and convenient USB programming make this instrument a very versatile temperature measurement device. These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions. TT230 Series Transmitter onfiguration Software is downloadable (FREE) from www.acromag.com. Windows XP, Vista, 7, & 8 The Agility onfig Tool is downloadable (FREE) at the Google Play Store For Android Devices only Key Features & Benefits Easy setup and digital calibration via USB with Windows configuration software Selectable RTD or linear resistance input type: Pt RTD (100Ω, 200Ω, 500Ω, or 1000Ω), Ni RTD (120Ω), u RTD (10Ω), or Resistance (0-450Ω) 1500V isolation between input/output circuits Space-saving 12.5mm (0.5 inch) unit with pluggable terminals for convenient wiring High accuracy, linearity, stability, and reliability Supports normal or reverse-acting output Supports sink or source output wiring User-selectable filtering (none, low, med., high) Fast response (as low as 22ms) Selectable upscale or downscale operation for sensor errors and lead-break detection NAMUR-compliant output loop current Shock (25g) and vibration (4g) resistant Wide ambient operation (-40 to 80 ) E and UL/cUL lass 1 Div 2 Zone 2 approvals TT235 Model software allows you to configure transmitters offline, save the file, and download into units later, at your convenience. Bulletin #8400-755c

TT235 Isolated RTD/resistance input two-wire transmitter Performance Specifications IMPORTANT: To prevent damage or errors from grounded Ps and surges, Acromag strongly recommends use of their USB-ISOLATOR when configuring a TT230 Series transmitter. USB Interface USB onnector USB Mini-B type socket, 5-pin. USB Data Rate 12Mbps. USB v1.1 and 2.0 compatible. USB Transient Protection Transient voltage suppression on power and data lines. USB able Length 5.0 meters maximum. Driver Not required. Uses built-in Human Interface Device (HID) USB drivers of the Windows operating system. Default onfiguration 100Ω Pt RTD, α=0.00385, -200 to 850 input, 4-20mA output, upscale break detect, medium filter. onfiguration Two-, three- or four-wire sensor input connections. Programs in, K, F, or ohmic integer values only. Ranges Type Range Accuracy 2 RTD, Pt 100Ω RTD, Pt 200Ω RTD, Pt 500Ω RTD, Pt 1000Ω RTD, Ni 120Ω (Minco 7-120) RTD, u 10Ω (Minco 1-9) Resistance (linear) 1-200 to 850 (-328 to 152 F) -200 to 850-200 to 850-200 to 850-80 to 320 (-112 to 08 F) -200 to 270 (-328 to 518 F) 0 to 450Ω ±0.2, ±0.019% ±0.3, ±0.029% ±0.5, ±0.048% ±1.0, ±0.095% ±0.08, ±0.020% ±0.5, ±0.10% ±0.05Ω, ±0.010% Note 1: Linear resistance input range approaches but does not include 0Ω and 500Ω. If exactly 0Ω or 500Ω is measured, break detection is triggered. Note 2: Rated accuracy (in and % of span) applies for input spans greater than 5% of input full-scale. Scaling Adjust Zero: 0 to 95% of range, typical. Full scale: 5 to 100% of full scale range, typical. Lead Break (Sensor Burnout) Detection onfigurable for either upscale or downscale. Output Output Range 4 to 20mA D. Under-range capability 3.5mA. Over-range capability 24mA. Output ompliance Rload = (Vsupply - 11V) / 0.020A. Rload = 0 to 50 ohms @ 24V D. Output DA Resolution 1-bit D/A converter Output Accuracy Better than ±0.05% of span, typical (±0.1% max.) for for nominal input spans. Includes the effects of repeatability, terminal point conformity, and linearization, but does not include sensor error. Ambient Temperature Effect Better than ±0.008% per of input span or ±80ppm/, typical. Includes the combined effects of zero and span drift over temperature. Output Response Time (for step input change) No filter: 22ms. Low filter: 50ms. Medium filter: 10ms. High filter: 1210ms. Environmental Operating temperature -40 to 80 (-40 to 17 F). Storage temperature -40 to 85 (-40 to 185 F). Relative humidity 5 to 95% non-condensing. Power Requirement 12-32V D SELV (Safety Extra Low Voltage), 24mA maximum. Shock and Vibration Immunity Vibration: 4g, per IE 008-2-4. Shock: 25g, per IE 008-2-27. Electromagnetic ompatibility (EM) ompliance Radiated Emissions: BS EN 1000--4, ISPR 1. RFI: BS EN 1000--2, IE 1000-4-3. onducted RFI: BS EN 1000--2, IE 1000-4-. ESD: BS EN 1000--2, IE 1000-4-2. EFT: BS EN 1000--2, IE 1000-4-4. Surge Immunity: BS EN 1000--2, IE 1000-4-5. Approvals E compliant. UL/cUL lass I Div. 2 Zone 2. Physical General General-purpose enclosure designed for mounting on 35mm T-type DIN rail. ase Material Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General-purpose NEMA Type 1 enclosure. I/O onnectors Removable plug-in terminal blocks rated for 12A/250V; AWG #2-12, stranded or solid copper wire. Dimensions 12.5 x 114.5 x 99.0 mm (0.5 x 4.51 x 3.90 inches). Shipping Weight 0.22 kg (0.5 pounds) packed. Models TT235-000 Transmitter, isolated RTD/resistance input. Services TT230-onfig/al Factory custom configuration/calibration service. Specify input type, input/output zero and full-scale values, filtering, and sensor fault settings on order. Software TT-SIP (recommend one kit per customer) Software Interface Package for Acromag TT Series transmitters. Includes configuration software D-ROM (5040-944), isolator (USB-ISOLATOR) and two USB cables (4001-112, 4001-113). Accessories See www.acromag.com for more information. USB-ISOLATOR USB-to-USB isolator, includes USB cable (4001-112). All trademarks are property of their respective owners. opyright Acromag, Inc. 2015. Data subject to change without notice. Printed in USA 8/2015

TT23 urrent/millivolt input two-wire/three-wire transmitter BOTTOM VIEW (INPUT SIDE) TOP VIEW (OUTPUT SIDE) URRENT (ma D) VOLTAGE (V D) V SHIELDED ABLE OPTIONAL SHIELD GROUND SHIELDED ABLE INPUT 1 I 2 INPUT 3 V 4 1 2 3 4 TB1 TB2 5 7 8 Local Power Supply w/ Sourced Output I 5 SINKING 24V D R INPUT LOAD LOAL I ARD 8 SUPPLY 7 USB onfigured SIDE VIEW 99.0 mm (3.90 in.) 12.5 mm (0.50 in.) 114.5 mm (4.51 in.) Loop-Powered w/ Sinking Output I P 24VD 5 I DS/PL SOURING RV INPUT ARD Multi-range ±20mA or ±500mV input 4-20mA output (sink/source) 12-32V D loop/local power Description The TT23 model is a space-saving two-wire transmitter that isolates and converts a D current or low voltage input to a proportional 4-20mA control signal. A single unit supports both voltage and current input for extra flexibility. Power is received from the output loop current or a D supply when using a three-wire connection. High-voltage isolation separates the input from the output circuit. Isolation protects from surges, reduces noise, and eliminates ground loop errors. Setup and calibration are fast and easy with a convenient USB connection to your P and Acromag s Windows configuration software. Advanced signal processing capabilities, variable range input, and convenient USB programming make this instrument a very versatile temperature measurement device. These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions. TT230 Series Transmitter onfiguration Software is downloadable (FREE) from www.acromag.com. Windows XP, Vista, 7, & 8 The Agility onfig Tool is downloadable (FREE) at the Google Play Store For Android Devices only Key Features & Benefits Easy setup and digital calibration via USB with Windows configuration software Single unit supports unipolar and bipolar input ranges up to ±20mA or ±500mV D Accepts 0-20A A input (with external sensor) Space-saving 12.5mm (0.5 inch) unit with pluggable terminals for convenient wiring High accuracy, linearity, stability, and reliability User-selectable filtering (low, medium, high) Supports sink or source output wiring Supports reverse-acting (inverse) output 1500V input isolation NAMUR-compliant output loop current Shock (25g) and vibration (4g) resistant Mounts on Type T DIN-rail Wide ambient operation (-40 to 80 ) E compliant. UL/cUL lass 1 Div 2 Zone 2 approvals TT23 Model software allows you to configure transmitters offline, save the file, and download into units later, at your convenience. Bulletin #8400-3g

TT23 urrent/millivolt input two-wire/three-wire transmitter Performance Specifications IMPORTANT: To prevent damage or errors from grounded Ps and surges, Acromag strongly recommends use of their USB-ISOLATOR when configuring a TT230 Series transmitter. USB Interface USB onnector USB Mini-B type socket, 5-pin. USB Data Rate 12Mbps. USB v1.1 and 2.0 compatible. USB Transient Protection Transient voltage suppression on power and data lines. USB able Length 5.0 meters maximum. Driver Not required. Uses built-in Human Interface Device (HID) USB drivers of the Windows operating system. Default onfiguration/alibration : 4 to 20mA, medium filter. Output: 4 to 20mA. Ranges and Accuracy Range Accuracy ±500mV 0 to 500mV ±20mA 0 to 20mA 4 to 20mA 0 to 11.17mA (for A sensor) ±1mA ±0.05% of span ±0.05% of span ±0.05% of span ±0.05% of span ±0.05% of span ±0.05% of span ±0.05% of span Error includes the effects of repeatability, terminal point conformity, and linearization. Ambient Temperature Effect Better than ±80ppm/ (±0.008%/ ). Zero Scaling Adjust 0 to 95% of range, typical. Full Scale Adjust 5 to 100% of full scale range, typical. Impedance urrent input: 24.9 ohms. Voltage input: 15M ohms Over-Voltage Protection Bipolar Transient Voltage Suppressers (TVS), 5.V clamp level typical. Resolution Bipolar input: 1 part in 50000 (±25000) Unipolar input: 1 part in 25000 Filter Selectable digital filtering settings (low, medium, high). Filter Bandwidth Normal mode plus digital filtering within the AD. Bandwidth (-3dB) varies with digital filter setting from 4Hz without filtering to 0.33Hz with high filtering. Noise Rejection (ommon Mode, High Filter) 138dB @ 0Hz, typical with 100 ohm input unbalance. Output Output Range 4 to 20mA D. Output ompliance Rload = (Vsupply - 11V) / 0.020A. Rload = 0 to 50 ohms @ 24V D. Output Response Time (for step input change) Time to reach 98% of final output value (typical) Low filter 50 milliseconds Medium filter 150 milliseconds High filter 1200 milliseconds Environmental Operating temperature -40 to 80 (-40 to 17 F). Storage temperature -40 to 85 (-40 to 185 F). Relative humidity 5 to 95% non-condensing. Power Requirement 12-32V D SELV (Safety Extra Low Voltage), 24mA max. Isolation 1500V A peak. 250V A (354V D) continuous isolation between input and output circuits. Shock and Vibration Immunity Vibration: 5g, per IE 008-2-4. Shock: 50g, per IE 008-2-27. Electromagnetic ompatibility (EM) ompliance Radiated Emissions: BS EN 1000--4, ISPR 1. RFI: BS EN 1000--2, IE 1000-4-3. onducted RFI: BS EN 1000--2, IE 1000-4-. ESD: BS EN 1000--2, IE 1000-4-2. EFT: BS EN 1000--2, IE 1000-4-4. Surge Immunity: BS EN 1000--2, IE 1000-4-5. Approvals E compliant. UL/cUL listing. Designed for lass I; Division 2; Groups ABD; Zone 2. Physical General General-purpose enclosure designed for mounting on 35mm T-type DIN rail. ase Material Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General-purpose NEMA Type 1 enclosure. I/O onnectors Removable plug-in terminal blocks rated for 12A/250V; AWG #2-12, stranded or solid copper wire. Dimensions 12.5 x 114.5 x 99.0 mm (0.5 x 4.51 x 3.90 inches). Shipping Weight 0.22 kg (0.5 pounds) packed. Models TT23-000 Two-wire transmitter, current/millivolt input. Services TT230-onfig/al Factory custom configuration/calibration service. Specify input type, input/output zero and full-scale values, filtering, and sensor fault settings on order. Software TT-SIP (recommend one kit per customer) Software Interface Package for Acromag TT Series transmitters. Includes configuration software D-ROM (5040-944), isolator (USB-ISOLATOR) and two USB cables (4001-112, 4001-113). Accessories See www.acromag.com for more information. USB-ISOLATOR USB-to-USB isolator, includes USB cable (4001-112). 5020-350 A current sensor (toroidal transformer); converts 0-20A A to 0-11.17mA D. All trademarks are property of their respective owners. opyright Acromag, Inc. 2015. Data subject to change without notice. Printed in USA 8/2015

TT237 Process voltage input two-wire/three-wire transmitter BOTTOM VIEW (INPUT SIDE) TOP VIEW (OUTPUT SIDE) VOLTAGE (±1V D) VOLTAGE (±5V D, ±10V D) V SHIELDED ABLE OPTIONAL SHIELD GROUND SHIELDED ABLE INPUT 1 V 2 INPUT 3 V 4 1 2 3 4 TB1 TB2 5 7 8 Local Power Supply w/ Sourced Output I 5 SINKING 24V D R INPUT LOAD LOAL I ARD 8 SUPPLY 7 USB onfigured SIDE VIEW 99.0 mm (3.90 in.) 12.5 mm (0.50 in.) 114.5 mm (4.51 in.) Loop-Powered w/ Sinking Output I P 24VD 5 I DS/PL SOURING RV INPUT ARD Multi-range ±1V, ±5V, or ±10V input 4-20mA output (sink/source) 12-32V D loop/local power Description The TT237 model is a space-saving two-wire transmitter that isolates and converts a process level D voltage input to a proportional 4-20mA control signal. A single unit supports multiple voltage input ranges for extra flexibility. Power is received from the output loop current or a local D supply when using a three-wire connection. High-voltage isolation separates the input from the output circuit. Isolation protects from surges, reduces noise, and eliminates ground loop errors. Setup and calibration are fast and easy with a convenient USB connection to your P and Acromag s Windows configuration software. Advanced signal processing capabilities, variable range input, and convenient USB programming make this instrument a very versatile temperature measurement device. These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions. TT230 Series Transmitter onfiguration Software is downloadable (FREE) from www.acromag.com Windows XP, Vista, 7, & 8. The Agility onfig Tool is downloadable (FREE) at the Google Play Store For Android Devices only Key Features & Benefits Easy setup and digital calibration via USB with Windows configuration software Single unit supports ±1V, ±5V, and ±10V D input ranges Space-saving 12.5mm (0.5 inch) unit with pluggable terminals for convenient wiring High accuracy, linearity, stability, and reliability User-selectable filtering (low, medium, high) Supports sink or source output wiring Supports reverse-acting (inverse) output 1500V input isolation NAMUR-compliant output loop current Shock (25g) and vibration (4g) resistant Mounts on Type T DIN-rail Wide ambient operation (-40 to 80 ) E compliant. UL/cUL lass 1 Div 2 Zone 2 approvals TT237 Model software allows you to configure transmitters offline, save the file, and download into units later, at your convenience. Bulletin #8400-4i

TT237 Process voltage input two-wire/three-wire transmitter Performance Specifications IMPORTANT: To prevent damage or errors from grounded Ps and surges, Acromag strongly recommends use of their USB-ISOLATOR when configuring a TT230 Series transmitter. USB Interface USB onnector USB Mini-B type socket, 5-pin. USB Data Rate 12Mbps. USB v1.1 and 2.0 compatible. USB Transient Protection Transient voltage suppression on power and data lines. USB able Length 5.0 meters maximum. Driver Not required. Uses built-in Human Interface Device (HID) USB drivers of the Windows operating system. Default onfiguration/alibration : ±10V D, medium filtering. Output: 4 to 20mA. Ranges and Accuracy Range Accuracy ±1V D ±5V D ±10V D ±0.05% of span ±0.05% of span ±0.05% of span Error includes the effects of repeatability, terminal point conformity, and linearization. Ambient Temperature Effect Better than ±80ppm/ (±0.008%/ ). Zero Scaling Adjust 0 to 95% of range, typical. Full Scale Adjust 5 to 100% of full scale range, typical. Impedance ±1V input: 15M ohms. ±5V input: >1M ohms. ±10V input: >1M ohms. Over-Voltage Protection Bipolar Transient Voltage Suppressers (TVS), 14V working and 18V clamp level typical. Resolution Bipolar input: 1 part in 50000 (±25000) Unipolar input: 1 part in 25000 Filter Selectable digital filtering settings (low, medium, high). Filter Bandwidth Normal mode plus digital filtering within the AD. Bandwidth (-3dB) varies with digital filter setting from 4Hz without filtering to 0.33Hz with high filtering. Noise Rejection (ommon Mode, High Filter) 138dB @ 0Hz, typical with 100 ohm input unbalance. Output Output Range 4 to 20mA D. Output ompliance Rload = (Vsupply - 11V) / 0.020A. Rload = 0 to 50 ohms @ 24V D. Output Response Time (for step input change) Time to reach 98% of final output value (typical) Low filter 50 milliseconds Medium filter 150 milliseconds High filter 1200 milliseconds Environmental Operating temperature -40 to 80 (-40 to 17 F). Storage temperature -40 to 85 (-40 to 185 F). Relative humidity 5 to 95% non-condensing. Power Requirement 12-32V D SELV (Safety Extra Low Voltage), 24mA max. Isolation 1500V A peak. 250V A (354V D) continuous isolation between input and output circuits. Shock and Vibration Immunity Vibration: 5g, per IE 008-2-4. Shock: 50g, per IE 008-2-27. Electromagnetic ompatibility (EM) ompliance Radiated Emissions: BS EN 1000--4, ISPR 1. RFI: BS EN 1000--2, IE 1000-4-3. onducted RFI: BS EN 1000--2, IE 1000-4-. ESD: BS EN 1000--2, IE 1000-4-2. EFT: BS EN 1000--2, IE 1000-4-4. Surge Immunity: BS EN 1000--2, IE 1000-4-5. Approvals E compliant. UL/cUL listing. Designed for lass I; Division 2; Groups ABD; Zone 2. Physical General General-purpose enclosure designed for mounting on 35mm T-type DIN rail. ase Material Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General-purpose NEMA Type 1 enclosure. I/O onnectors Removable plug-in terminal blocks rated for 12A/250V; AWG #2-12, stranded or solid copper wire. Dimensions 12.5 x 114.5 x 99.0 mm (0.5 x 4.51 x 3.90 inches). Shipping Weight 0.22 kg (0.5 pounds) packed. Models TT237-000 Two-wire transmitter, process voltage input. Services TT230-onfig/al Factory custom configuration/calibration service. Specify input type, input/output zero and full-scale values, filtering, and sensor fault settings on order. Software TT-SIP (recommend one kit per customer) Software Interface Package for Acromag TT Series transmitters. Includes configuration software D-ROM (5040-944), isolator (USB-ISOLATOR) and two USB cables (4001-112, 4001-113). Accessories See www.acromag.com for more information. USB-ISOLATOR USB-to-USB isolator, includes USB cable (4001-112). All trademarks are property of their respective owners. opyright Acromag, Inc. 2015. Data subject to change without notice. Printed in USA 8/2015

TT238 High voltage input two-wire/three-wire transmitter BOTTOM VIEW (INPUT SIDE) TOP VIEW (OUTPUT SIDE) VOLTAGE (±15V D) VOLTAGE (±75V D, V ±150V D) SHIELDED ABLE OPTIONAL SHIELD GROUND SHIELDED ABLE INPUT 1 V 2 INPUT 3 V 4 1 2 3 4 TB1 TB2 5 7 8 Local Power Supply w/ Sourced Output I 5 SINKING 24V D R INPUT LOAD LOAL I ARD 8 SUPPLY 7 USB onfigured SIDE VIEW 99.0 mm (3.90 in.) 12.5 mm (0.50 in.) 114.5 mm (4.51 in.) Loop-Powered w/ Sinking Output I P 24VD 5 I DS/PL SOURING RV INPUT ARD Multi-range ±15V, ±75V, or ±150V input 4-20mA output (sink/source) 12-32V D loop/local power Description The TT238 model is a space-saving two-wire transmitter that isolates and converts a high level D voltage input to a proportional 4-20mA control signal. A single unit supports multiple voltage input ranges for extra flexibility. Power is received from the output loop current or a local D supply when using a three-wire connection. High-voltage isolation separates the input from the output circuit. Isolation protects from surges, reduces noise, and eliminates ground loop errors. Setup and calibration are fast and easy with a convenient USB connection to your P and Acromag s Windows configuration software. Advanced signal processing capabilities, variable range input, and convenient USB programming make this instrument a very versatile temperature measurement device. These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions. TT230 Series Transmitter onfiguration Software is downloadable (FREE) from www.acromag.com. Windows XP, Vista, 7, & 8 The Agility onfig Tool is downloadable (FREE) at the Google Play Store For Android Devices only Key Features & Benefits Easy setup and digital calibration via USB with Windows configuration software Single unit supports ±15V, ±75V, and ±150V D input ranges Space-saving 12.5mm (0.5 inch) unit with pluggable terminals for convenient wiring High accuracy, linearity, stability, and reliability User-selectable filtering (low, medium, high) Supports sink or source output wiring Supports reverse-acting (inverse) output 1500V input isolation NAMUR-compliant output loop current Shock (25g) and vibration (4g) resistant Mounts on Type T DIN-rail Wide ambient operation (-40 to 80 ) E compliant. UL/cUL lass 1 Div 2 Zone 2 approvals TT238 Model software allows you to configure transmitters offline, save the file, and download into units later, at your convenience. Bulletin #8400-5g

TT238 High voltage input two-wire/three-wire transmitter Performance Specifications IMPORTANT: To prevent damage or errors from grounded Ps and surges, Acromag strongly recommends use of their USB-ISOLATOR when configuring a TT230 Series transmitter. USB Interface USB onnector USB Mini-B type socket, 5-pin. USB Data Rate 12Mbps. USB v1.1 and 2.0 compatible. USB Transient Protection Transient voltage suppression on power and data lines. USB able Length 5.0 meters maximum. Driver Not required. Uses built-in Human Interface Device (HID) USB drivers of the Windows operating system. Default onfiguration/alibration : ±150V, medium filtering. Output: 4 to 20mA. Ranges and Accuracy Range Accuracy ±15V D ±75V D ±150V D ±0.05% of span ±0.05% of span ±0.05% of span Error includes the effects of repeatability, terminal point conformity, and linearization. Ambient Temperature Effect Better than ±80ppm/ (±0.008%/ ). Zero Scaling Adjust 0 to 95% of range, typical. Full Scale Adjust 5 to 100% of full scale range, typical. Impedance Greater than 1M ohms. Over-Voltage Protection Bipolar Transient Voltage Suppressers (TVS), 220V working typical. Resolution Bipolar input: 1 part in 50000 (±25000) Unipolar input: 1 part in 25000 Filter Selectable digital filtering settings (low, medium, high). Filter Bandwidth Normal mode plus digital filtering within the AD. Bandwidth (-3dB) varies with digital filter setting from 4Hz without filtering to 0.33Hz with high filtering. Noise Rejection (ommon Mode, High Filter) 138dB @ 0Hz, typical with 100 ohm input unbalance. Output Output Range 4 to 20mA D. Output ompliance Rload = (Vsupply - 11V) / 0.020A. Rload = 0 to 50 ohms @ 24V D. Output Response Time (for step input change) Time to reach 98% of final output value (typical) Low filter 50 milliseconds Medium filter 150 milliseconds High filter 1200 milliseconds Environmental Operating temperature -40 to 80 (-40 to 17 F). Storage temperature -40 to 85 (-40 to 185 F). Relative humidity 5 to 95% non-condensing. Power Requirement 12-32V D SELV (Safety Extra Low Voltage), 24mA max. Isolation 1500V A peak. 250V A (354V D) continuous isolation between input and output circuits. Shock and Vibration Immunity Vibration: 5g, per IE 008-2-4. Shock: 50g, per IE 008-2-27. Electromagnetic ompatibility (EM) ompliance Radiated Emissions: BS EN 1000--4, ISPR 1. RFI: BS EN 1000--2, IE 1000-4-3. onducted RFI: BS EN 1000--2, IE 1000-4-. ESD: BS EN 1000--2, IE 1000-4-2. EFT: BS EN 1000--2, IE 1000-4-4. Surge Immunity: BS EN 1000--2, IE 1000-4-5. Approvals E compliant. UL/cUL listing. Designed for lass I; Division 2; Groups ABD; Zone 2. Physical General General-purpose enclosure designed for mounting on 35mm T-type DIN rail. ase Material Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General-purpose NEMA Type 1 enclosure. I/O onnectors Removable plug-in terminal blocks rated for 12A/250V; AWG #2-12, stranded or solid copper wire. Dimensions 12.5 x 114.5 x 99.0 mm (0.5 x 4.51 x 3.90 inches). Shipping Weight 0.22 kg (0.5 pounds) packed. Models TT238-000 Two-wire transmitter, high voltage input. Services TT230-onfig/al Factory custom configuration/calibration service. Specify input type, input/output zero and full-scale values, filtering, and sensor fault settings on order. Software TT-SIP (recommend one kit per customer) Software Interface Package for Acromag TT Series transmitters. Includes configuration software D-ROM (5040-944), isolator (USB-ISOLATOR) and two USB cables (4001-112, 4001-113). Accessories See www.acromag.com for more information. USB-ISOLATOR USB-to-USB isolator, includes USB cable (4001-112). All trademarks are property of their respective owners. opyright Acromag, Inc. 2015. Data subject to change without notice. Printed in USA 8/2015

TT239 Frequency/pulse/PWM input two-wire transmitter Frequency/Pulse BOTTOM VIEW (INPUT SIDE) TOP VIEW (OUTPUT SIDE) MAG PIKUP ENODER LINE FREQ TTL/PNP/NPN DRY ONTAT 2/3-WIRE PROX SWITH TURBINE FLOWMETER PULSE UNI/BIPOLAR PWM/DUTY YLE 1 2 3 4 IN RTN OM OM 1 2 3 4 5 7 8 Local Power Supply w/ Sourced Output I 5 SINKING 24V D R INPUT LOAD LOAL I ARD 8 SUPPLY 7 USB onfigured SIDE VIEW 99.0 mm (3.90 in.) 12.5 mm (0.50 in.) 114.5 mm (4.51 in.) Loop-Powered w/ Sinking Output I P 24VD 5 I DS/PL SOURING RV INPUT ARD Multi-range frequency/pulse input 4-20mA output (sink/source) 12-32V D local/local power Description The TT239 model is a space-saving two-wire transmitter that isolates and converts a frequency, pulse, or pulse-width modulation (PWM) input to a proportional 4-20mA signal. You can select to measure either the input frequency or the duty cycle. Power is received from the output loop current or a D supply when using a three-wire conneciton. High-voltage isolation separates the input from the output circuit. Isolation protects from surges, reduces noise, and eliminates ground loop errors. Setup and calibration are fast and easy with a convenient USB connection to your P and Acromag s Windows configuration software. Advanced signal processing capabilities, variable range input, and convenient USB programming make this instrument a very versatile frequency measurement device. These transmitters can withstand harsh industrial environments and operate reliably across a wide temperature range with very low drift. They feature RFI, EMI, ESD, EFT, and surge protection plus low radiated emissions. TT230 Series Transmitter onfiguration Software is downloadable (FREE) from www.acromag.com. Windows XP, Vista, 7, & 8 The Agility onfig Tool is downloadable (FREE) at the Google Play Store For Android Devices only Key Features & Benefits Easy setup and digital calibration via USB with Windows configuration software Measures frequency or duty cycle and interfaces many input types up to 100KHz Accepts input amplitudes up to 120Vrms (±170V D, unipolar or bipolar) Adjustable 0Hz cut-off, sample averaging, and output update time Software configurable pull-up/down resistors (4V D input pull-up for sensors/transducers) 1500V isolation between input/output circuits Space-saving 12.5mm (0.5 inch) unit with pluggable terminals for convenient wiring Fast response time and high accuracy Supports normal or reverse-acting output Supports sink or source output wiring NAMUR-compliant output loop current Shock (25g) and vibration (4g) resistant Wide ambient operation (-40 to 80 ) E compliant. UL/cUL lass 1 Div 2 Zone 2 approvals TT239 Model software allows you to configure transmitters offline, save the file, and download into units later, at your convenience. Bulletin #8400-755d

Transmitters: TT330 Series TT239 Frequency/pulse/PWM input two-wire transmitter Performance Specifications IMPORTANT: To prevent damage or errors from grounded Ps and surges, Acromag strongly recommends use of their USB-ISOLATOR when configuring a TT330 Series transmitter. USB Interface USB onnector USB Mini-B type socket, 5-pin. USB Data Rate 12Mbps. USB v1.1 and 2.0 compatible. USB Transient Protection Transient voltage suppression on power and data lines. USB able Length 5.0 meters maximum. Driver Not required. Uses built-in Human Interface Device (HID) USB drivers of the Windows operating system. Default onfiguration/alibration ±5.0V Square Wave; Threshold = Bipolar 0.0V; Hysteresis ±25mV; Measurement = Frequency; Pull Up/Down = Disabled; Excitation = Enabled; 0Hz utoff = 0.5Hz; Sample Average = 1; Output Range = 4-20mA; I/O Scaling = 0Hz to 10KHz, Normal Acting; Output Update = 100ms. Frequency onfigurable for any range from 0Hz to 100KHz. Accepts unipolar (non-zero crossing) or bipolar (zero crossing) input signals. 0.5Hz minimum span. 10µs minimum pulse width. Ranges Frequency 0 to 100Hz 0 to 1KHz 0 to 5KHz 0 to 10KHz 0 to 10KHz 0 to 10KHz 0 to 100KHz 0 to 100KHz 0 to 100KHz PWM arrier Freq 0 to 100Hz 0 to 1KHz 0 to 3KHz Output Update Any rate Any rate Any rate 10ms 100ms 1000ms 10ms 100ms 1000ms ycle Range 1 to 99% 10 to 90% 20 to 80% Resolution 1 part in 0000 1 part in 000 1 part in 1200 1 part in 0000 1 part in 00000 1 part in 000000 1 part in 0000 1 part in 00000 1 part in 000000 Resolution 1 part in 0000 1 part in 000 1 part in 1200 Typical Accuracy ±0.05Hz ±0.5Hz ±1Hz ±200Hz ±20Hz ±2Hz ±400Hz ±40Hz ±4Hz Typical Accuracy ±0.02% ±0.2% ±2.0% Scaling Adjust Zero: Adjustable over 0 to 99% of full-scale input. Full scale: Adjustable over 0.5Hz to 100KHz. ut-off frequency: Adjustable over 0.01Hz to 100KHz. Pull-up/Pull-down (internal, software-select) onfigurable 12.4KΩ pull-up to 4V and 1KΩ pulldown to FRTN, or disabled. 15V D maximum input. 4V pull-up with ±28mV hysteresis or 3V when ±84mV. Unipolar Signal onfiguration: Amplitude: 0 to 3V D min., 0 to 170V D max. Thresholds: onfigurable for 1.V D (±25mV hysteresis) or 5V D (±83mV hysteresis), typical. Bipolar Signal onfiguration: Amplitude: ±50 to ±200mV min. (depending on range and hysteresis), 120Vrms max. (±170V D). Thresholds: 0mV nominal (±25 or ±83mV hysteresis). Output Output Range 4 to 20mA D, wired as sink or source. Under-range capability 3.mA. Over-range 24mA. Output ompliance Rload = (Vsupply - 12V) / 0.020A. Rload = 0 to 00 ohms @ 24V D. Output DA Resolution 1-bit D/A converter Output Update Software configurable from 10ms to 5000ms. Determines the rate at which the output signal is updated, unless optionally overridden. Output Settling Time 1ms, 0% to 98% for a step-change in input, typical. Output Accuracy Better than ±0.05% of span, typical (±0.1% max.) for for nominal input spans. Includes the effects of repeatability, terminal point conformity, and linearization, but does not include sensor error. Ambient Temperature Effect Better than ±0.0020% per of input span or ±20ppm/, typical. Includes the combined effects of zero and span drift over temperature. Environmental Temperature Range Operation: -40 to 80 (-40 to 17 F). Storage: -40 to 85 (-40 to 185 F). Relative humidity 5 to 95% non-condensing. Power Requirement 12-32V D SELV (Safety Extra Low Voltage), 24mA maximum. Isolation 1500V A peak. 250V A (354V D) continuous isolation between input and output circuits. Shock and Vibration Immunity Vibration: 4g, per IE 008-2-4. Shock: 25g, per IE 008-2-27. Electromagnetic ompatibility (EM) ompliance Radiated Emissions: BS EN 1000--4, ISPR 1. RFI: BS EN 1000--2, IE 1000-4-3. onducted RFI: BS EN 1000--2, IE 1000-4-. ESD: BS EN 1000--2, IE 1000-4-2. EFT: BS EN 1000--2, IE 1000-4-4. Surge Immunity: BS EN 1000--2, IE 1000-4-5. Approvals E compliant. UL/cUL listing. Designed for lass I; Division 2; Groups ABD; Zone 2 Physical General General-purpose enclosure designed for mounting on 35mm T-type DIN rail. ase Material Self-extinguishing polyamide, UL94 V-0 rated, color light gray. General-purpose NEMA Type 1 enclosure. I/O onnectors Removable plug-in terminal blocks rated for 12A/250V; AWG #2-12, stranded or solid copper wire. Dimensions 12.5 x 114.5 x 99.0 mm (0.5 x 4.51 x 3.90 inches). Shipping Weight 0.22 kg (0.5 pounds) packed. Models TT239-000 Transmitter, isolated frequency/pulse/pwm input Services TT230-onfig/al Factory custom configuration/calibration service. Specify input type, input/output zero and full-scale values, filtering, and sensor fault settings on order. Software TT-SIP (recommend one kit per customer) Software Interface Package for Acromag TT Series transmitters. Includes configuration software D-ROM (5040-944), isolator (USB-ISOLATOR) and two USB cables (4001-112, 4001-113). Accessories See www.acromag.com for more information. USB-ISOLATOR USB-to-USB isolator, includes USB cable (4001-112). All trademarks are property of their respective owners. opyright Acromag, Inc. 2015. Data subject to change without notice. Printed in USA 8/2015

Accessories USB-ISOLATOR USB-to-USB Isolator LEFT SIDE TOP VIEW RIGHT SIDE 3 4 USB TYPE B 2 1 P ONNET MODEL: USB-ISOLATOR DEVIE ONNET USB TYPE A 1 2 3 4 1.85 (4.99mm) POWER RESET ONNETION 0.93 (23.50mm) 2.40 (0.9mm) USB-powered, USB 2.0 and 1.1 compatible 1500V A / 2100V D isolation No drivers required Description This compact, industrial-grade isolator provides a high-voltage isolation barrier between a computer and a connected USB device. The isolation protects equipment from electrical surges and transient voltage spikes. It also eliminates ground loop currents flowing between the P and peripherals which can cause damage and inaccurate measurements. Additionally, isolation minimizes conducted noise from static discharge, magnetic fields, and radio frequency interference. Acromag s USB isolator is very easy to use. The isolator inserts in-line with the USB connection and operates transparently. No special software drivers are required. The unit receives power from the P s USB port and isolates that power to the connected device. High noise immunity and low radiated emissions ensure reliable data transfer in sensitive applications. A number of high-performance features help provide convenient and dependable operation. The green LED indicates that power is being received and blinks if the connected device draws too much current. An internal jumper lets you switch from Full Speed (12 Mbps) to Low Speed (1.5 Mbps) communication. The reset button offers a simple way to reinitialize a connected device without breaking the cable connection. High-retention USB sockets keep cables securely attached under shock and vibration. Key Features & Benefits Isolates and protects a USB peripheral from a USB host Electrical isolation up to 1500V A / 2100V D ommon mode filtering on all data lines Built-in surge/transient suppression up to 8kV on all ports Self-powered through the USB port Supports USB 2.0 full speed (12 Mbps) and USB 1.1 low speed (1.5 Mbps) data rates with jumper-selection LED for power indication and diagnostics Reset button to reinitialize and re-enumerate peripheral devices Output short circuit protection with auto-retry No software or configuration required (transparent operation) Uses standard high-retention USB Type A/B cable connections (includes 1m cable) ompact size and rugged design for harsh environments Wide ambient temperature operation -40 to 70 (-40 to 158 F) E, F, UL/cUL approvals Models USB-ISOLATOR USB isolator, includes USB cable (Part # 4001-112) for isolator-to-p connection TT-SIP D-ROM (Part #5040-944), USB isolator and two USB cables (Part # 4001-112, 4001-113) for configuration of Acromag TT Series transmitters and SP Series Signal Splitters. Accessories 4001-112 USB cable, 1 meter, with Type A to Type B plugs 4001-113 USB cable, 1 meter, with Type A to Mini-B plugs Bulletin #8400-23c

Accessories USB-ISOLATOR USB-to-USB Isolator Performance Specifications USB Port Interface Standards USB 1.1 and 2.0 compatible, full speed (12Mbps, default) and low speed (1.5Mbps) data rates supported. For low speed data rates, an internal jumper is provided for user setting. onnection is transparent, no software or configuration is required. Isolator will not be enumerated in the device manager. Physical Dimensions 2.40 Length x 1.85 Wide x 0.925 High (0.9mm x 4.99mm x 23.495mm). onnectors Standard high retention USB A/B connectors with minimum withdrawal force of 15 Newtons. 1 meter A/B cable included. P onnector USB Type B receptacle Device onnector USB Type A receptacle LED Indicator Green LED indicates isolator receiving 5V power from the USB computer bus. Flashing indicates short circuit/ retries on peripheral side. Reset Button Resets the connection to the USB peripheral device for reinitialization and re-enumeration. Enclosure Material ABS Resin, UL94 rated, IP30 plastic case. Environmental Operating temperature -40 to 70 (-40 to 158 F). Storage temperature -40 to 85 (-40 to 185 F). Relative humidity 5 to 95% non-condensing. Power P onnect Side: Standard USB bus power (5V D). Device onnect Side: 5V D / 120mA with full power connection from P. Includes over-current protection with auto-retry. Isolation 1500V A / 2100V D peak isolation. 250V A continuous safety isolation. Agency Approvals: E and F compliant. UL/cUL lass 1 Div. 2 Zone 2. Radiated Field Immunity (RFI) Designed to comply with IE1000-4-3 Level 3 and EN50082-1. Electromagnetic ompatibility (EM) Minimum immunity per EN1000--2:2001 Electrostatic Discharge (ESD) Immunity Per IE1000-4-2. Radiated Field Immunity (RFI) Per IE1000-4-3. Electrical Fast Transient Immunity (EFT) Per IE1000-4-4. omplies with IE1000-4-4 Level 3 and EN50082-1. Surge Immunity omplies with IE1000-4-5 Level 3 and EN50082-1. Per IE1000-4-5. onducted RF Immunity (RFI) Per IE1000-4-. Emissions Per EN1000--4:2001. Radiated Frequency Emissions Per ISPR11 lass A. Meets or exceeds EN50081-1 for lass B equipment. EXAMPLE USB ONNETION DRAWING HOST USB USB-A HOST OMPUTER WINDOWS OS 4001-112 ABLE 1 METER AROMAG TRANSMITTER ST131-000 USB Mini-B USB-B LED USB-ISOLATOR P ONNET MODEL: USB-ISOLATOR RESET POWER ONNETION DEVIE ONNET 4001-113 ABLE USB-A 1 METER All trademarks are property of their respective owners. opyright Acromag, Inc. 2013. Data subject to change without notice. Printed in USA /2013

Transmitters: TT Series Acromag Agility onfig Tool Mobile Application The Agility onfig Tool is a mobile application that allows easy setup and configuration of Acromag TT Series transmitters via a tethered mobile device. This free app is available for Android devices at the Google Play store at Acromag Agility onfig Tool. Key Features & Benefits onnects to Acromag TT Series transmitters (except models TT231 and TT233) Requires the use of USB OTG able (Acromag part #: 5028-55) and USB A to Mini B able (Acromag part #: 4001-113) onfigures and calibrates TT Series products via phone or tablet running Android 4.0 IS (Ice ream Sandwich) or later. View wiring diagrams, even without an internet connection Perform quick and easy field diagnostics and troubleshooting With a couple of taps, quickly configure input, output, unit and scaling options. Ideal for field technicians Quick and easy access to the wiring diagram, even offline without internet access. Bulletin #8400-83