The SFC 1000PA P2DAAA can be mounted on a prover trailer, which can be moved from field to field to provide proving services.

Similar documents
Micro MV P2DAAA. Custody transfer accuracy Built-in multivariable 3-in-1 transmitter. Daily. Zigbee wireless radio. Extended length battery backup

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

PAD - Heavy Duty Differential Pressure Trasmitter

Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

E-Chart Image Release History

Model Sono-Trak Transit Time

Rosemount 3095 MultiVariable Transmitter with MODBUS Protocol

Field Devices and Wiring

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

LOW POWER FLOW COMPUTERS Greg Phillips Bristol Babcock Inc Governors Circle West, Suite F, Houston, TX 77092

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

11A Series Absolute Pressure Transmitters

Series Smart Pressure Transmitter

Mass Flow Transmitter THE PROVEN LEADER IN MULTIVARIABLE MASS FLOW MEASUREMENT.

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

mass flowmeter for compressed air

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

F-SERIES FOR. Indicators Totalizers Transmitters Flow computers Batch controllers Monitors. Flow Level Pressure Temperature

Rosemount 3095FT MultiVariable Flowmeter

ABB conductivity analyzer and probe package

RCM DIRECT READING FLOWMETER

Compact Orifice Flow Meter

RUNYI GROUP AJ FLOW TOTALIZER. Features

Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement

OriMaster FPD500 Compact orifice flowmeter. Orifice-based flow metering made simple

2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter. Kent-Taylor

Series T. General Eastern Differential Pressure Transmitters. GE Sensing. Description

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610f

Ambient Conditions. Operating Conditions. Pressure

VELTRON II Microprocessor Based Pressure & Flow Smart

SonoMeter 31 Energy Meters

Rosemount 2088 Absolute and Gage Pressure Transmitter A TRADITION OF EXCELLENCE IN PERFORMANCE FROM THE INDUSTRY LEADERS

914DNS. Pressure and Density Transmitter. Features. 1 Datasheet 914DNS Pressure and density transmitter.

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

Non-Submersible Industrial Pressure Transducer

Smart Pressure Transmitter

A New Generation of Pressure Transmitters

FIELD DEVICES - PRESSURE

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

SMART TEMPERATURE TRANSMITTERS. smar

PROCESS & TEMPERATURE CONTROLLERS

Pressure Transmitter SIL

New! Micro Motion CNG050 Compressed Natural Gas Mass Flowmeter with MVD Technology. Product Data Sheet PS EU February 2001

Improve asset protection and utilization

Sarasota CM200 Sarasota HME900 Density Converter Electronics

A New Generation of Pressure Transmitters

AccuSolar SOLAR POWERED SYSTEM

S103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4" to 1/2" NPT. Proportional Valves. Features.

Magnetic Flowmeter Systems

and ClearSCADA s custom EFM object the SOLARPack 410 becomes a complete electronic flow measurement system. Chart Recorder Replacement

University of Rochester Design Standard August 13, 2014

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

Series T. Amphenol Advanced Sensors. Differential Pressure Transmitters

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Accessories for EST4 Series

FOSTEN AUTOMATION SÉRIE F500-RD

Modus M Series. General Eastern Differential Pressure Transmitters. GE Sensing

ED701 General Industry Pressure Transmitter

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

PLC-K506 Series FEATURES DESCRIPTION FEATURES

UTM10 Series Ultrasonic Transit-time Flowmeters

SECTION BUILDING METERING (Indianapolis Campus Only)

ph or ORP Transmitter

Using the AcuDew Moisture Transmitter

FICHA TÉCNICA DE PRODUTO

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610e

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

Microprocessor Gas and Steam Flow Computer Energy Flow Computer (Consumption and Enthalpy for Steam) Series: DigiFlow Type: 515

OPTITEMP TT 20 Technical Datasheet

Accutech DP20. Wireless differential pressure field unit

Advanced Test Equipment Rentals ATEC (2832) Clamp-on Ultrasonic Flow Meter Family

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES

Kotron Sentinel Model 804 RF Level Transmitter

SECTION AUTOMATED STORMWATER SAMPLING SYSTEM

Advanced, accurate and intelligent monitoring for your transformer

MICROMACHINED SILICON MODULAR PRESSURE SENSOR

FAST SAMPLING CONVERTER

Series 1000 and 2000 Transmitters with MVD TM Technology

Ultrasonic level transmitter, non-contact

E l e c t r o m a g n e t i c f l o w m e t e r s

DigitalFlow XMT868i. Panametrics Liquid Flow Ultrasonic Transmitter. GE Measurement & Control. Applications. Features

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use

Liquid Ultrasonic Flow Meters

ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging.

Introduction. Specifications LF620,LF622. Field Intelligent Device Series Electromagnetic Flowmeter Converter

RUN MAN OUT1 OUT2 FL40

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

Signet 9950 Dual Channel Transmitter

Materials (other materials see WIKA diaphragm seal program) Model S-10

MPU 200 Series B. Ultrasonic Gas Flowmeter. Specifications. Features. Principle of Operation

FIELD DEVICES PRESSURE

Temperature Parameter Electronics 1 Cell 1,2,3 LCD 4. C F C F C F -40 to to to to to to +122

Servo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability.

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

LST100 Ultrasonic level transmitter for upstream oil and gas

Preface WBPEEUI110504A0

Mass and Volume Flow Transmitter

Transcription:

The SFC 1000 P2DAAA is a dual meter run bidirectional flow computer with a built in Rosemount 205 Multivariable Transmitter (DP, P, and TEMP) for the measurement of liquid & Gas products. Using orifice plate, Venturi, turbine/pd/ultrasonic mass meter, or wedge devices, it can meter a wide variety of products, such as crude, refined product, LPG/NGL products, products that use table 24C, ethylene, propylene, and water. Fifty days of previous daily data, fifty previous batch data, and fifty previous hourly data are stored in the full format type reports. The previous 100 audit trail reports and 100 alarm reports are stored. User formatted reports and user formatted ticket reports are available. Sixteen different product files are user-configurable and stored in memory with an easy switch feature to enable the user to choose which product is being monitored at any given time. Product scheduling for batch operation is also available. SFC 1000PA P2DAAA SFC 1000PA P2DAAA prover flow computers store data for up to 60 meters and can easily be configured from inside a vehicle with a laptop. With the push of a button proving is initiated for any of the 60 meters. The flow computer controls the proving process and generates all the proving reports. When proving is complete a printed report is automatically generated to a serial printer port. The data can also be retrieved via a laptop at any time. The SFC 1000PA P2DAAA can be mounted on a prover trailer, which can be moved from field to field to provide proving services. Features 32-bit processor Multiple I/O options Custody transfer accuracy Turbine diagnostics Battery backup/ups Prover (SFC1000PA P2DAAA) Additional I/O options Stationary or portable systems Dual or single detectors Supports 4-way valve control Communications RS232 Modbus RS485 Modbus Analog and digital I/O Applications Liquid and gas measurement Wellhead measurement & automation Custody measurement and control Compressor stations Well optimization PID control Reports/Storage Daily Hourly Monthly Monthly day by day Alternative Power Extended length battery backup Solar powered

The SFC 1000 P2DAAA includes a factory integrated multivariable 3-in-1 digital transmitter manufactured by Rosemount for the simultaneous measurement of temperature, pressure, and differential pressure. It can also control pneumatic or electrical valves (on-off or variable by means of analog outputs or process PID control). The input/output assignment, flow equations, historical data storage, and other functions are carried out using Dynamic Flow Computers DYNACOM software. This software is Windows based, free of charge, and available for download/update at any time on our website. DYNACOM Software Capabilities: Flow computer diagnostics Configure inputs and outputs Configure PID control Personalize report time and content Configure and select the local LCD screen displayed parameters Reassign and customize MODBUS registers and values Create and implement custom math and formulas Input and output calibration Automatic and periodic downloading of flow computer reports Obtain historic data for display, saving, exportation, or printing Historic data is available in the memory of the flow computer for download or display. Maximum Report Storage: Hourly reports: 1536 hours* Daily reports: 64 * Daily reports, hour by hour: 64* Monthly reports: 6* Monthly, day by day: 2 months* Calibration reports: 20* Audit reports: 100* Alarm reports: 100* Special reports: HTML, and others *The number of reports stored can vary according to application.

Multivariable Transmitter The Multivariable Sensor is a 3-in-1 model 205 transmitter manufactured by Rosemount Inc. for Dynamic Flow Computers. This sensor measures static/ absolute pressure, differential pressure, and using an optional RTD, process temperature. These three process variables are available all the time and updates are sent to the flow computer up to NINE times per second. The model 205 is a culmination of the vast technological experience that Rosemount Inc. has in the multivariable field. It includes the well recognized and tested 3051C technology using capacitive cells for differential pressure as well as a patented piezoresistive/silicon sensors for measurement of absolute/ static pressures. The digital technology utilized in the production of the 205 module is the most advanced measurement technology on the market, assuring maximum accuracy and rangeability. The extensive use of patented technology concerning the sensors internal circuitry significantly reduces the size and the weight of the 205 sensor. The Multivariable Sensor measures three process variables at one time. It incorporates a capacitive differential pressure sensor, a piezoresistive absolute/static pressure sensor, and an optional connection for a two, three, or four wire RTD. The sensors convert the process variables to a digital format for direct communication with the flow computer. Electrical/Conduit Connections Process Connection Housing (Flow Computer) RTD Connection PHYSICAL SPECIFICATIONS Two 3/4" NPT. Two ¼' -18 NPT (multivariable) NEMA 4X class 1 div. 1 IP66 To flow computer terminal block or directly to multivariable Multivariable 3-in-1 (pressure, differential pressure, and temperature), manufactured by Rosemount Inc. Display Plasma; 2 Lines x 16 characters each line. Temperature Limits Operation: -40 to 185 F (-40 to 85 C) Storage: -50 to 190 F (-46 to 87 C) Humidity 100%

Voltage Power Consumption Solar Board (Optional) Polarity Processor FLASH ROM ROM Real Time Clock Optic Isolation Analog Input Pulse/Frequency Input Digital/Switch Input RTD Input Optic Isolation Digital/Switch Output Pulse Output Analog Output ELECTRICAL SPECIFICATIONS 12 to 30 VDC 4 watt 10/20 watts, 12 volts Reverse polarity protected 32 bits @ 16.7Mhz 4 MB @ 70 NANO seconds 2 MB @ 30 NANO seconds Years/Months/Days/Hours/Minutes INPUT SPECIFICATIONS Each input is optically isolated with ±250 VDC chassis isolation Four 4-20mA (or 0-5V) inputs (expandable to 6 inputs) Resolution 24 bits Three inputs (expandable to 4) 0-5000 HZ Signal must be > 70 mv for sine wave Signal must be > 6 volts for square wave Input 3 is for square wave only Four inputs 7-24VDC 0.25 Amp rating Two inputs (RTD input uses/disables 2 analog inputs) Direct connection to flow computer 4-Wire RTD, 24 bit resolution OUTPUT SPECIFICATIONS Each output is optically isolated with ±250 VDC chassis/ground isolation Three outputs 7-24VDC 0.25 Amp rating Two outputs (can also be assigned as digital output for a total of 5 digital outputs) 7-24VDC 0.5 Amp rating On/Off or pulses (to 125 pulses/sec.) Two outputs 4-20mA (external power required) For PID control or for data transmission Resolution 12 bits single ended

COMMUNICATION SPECIFICATIONS RS485 RS232 Protocol Monitor/Alarm Number of Trains Flow Calculation Primary Elements Engineering Units Base Conditions Equations Quantity 2 @ 1200 38400 bps Quantity 1 @ 1200 19200 bps MODBUS RTU / ASCII DIAGNOSTIC SPECIFICATIONS Multivariable: P, DP, T Analog inputs/outputs Digital/switch inputs Digital/switch outputs Pulse/frequency inputs Internal temperature Battery voltage Internal power supply FLOW COMPUTATION SPECIFICATIONS Two bi-directional (dependant on application) Simultaneous gas and liquid Differential: Orifice, V-Cone, Wedge, Annubar, Venturi, etc. Pulse/Frequency: Turbine, PD, Vortex, Ultrasonic, etc. US and Metric 60 F, 14.7 PSIA (15 C and 1 Kg. /Cm²) 68 F, 14.7 PSIA (20 C and 1 Kg/Cm²) AGA3, API14.3, AGA7, AGA9, API5.6, API5.7, AGA8 methods 1, 2, and detailed; API 2540; API11-2-1, 11-2-1M; 11-2,2, 11-2-2M; GPA15, 16; API2565; tables 5A,B; 6A,B,C; 23A,B,C; 24A,B,C; 53A,B; 54A,B,C; 23 and 24. Others added continuously, consult factory for complete list Function Differential Sensor Limits Absolute Sensor Limits Gage Sensor Limits Temperature Sensor (does not consider error from external RTD) Temperature Limits (Applies to Multivariable Flange temp. Does not apply to process temp) MULTIVARIABLE SPECIFICATIONS Gas, oil, water, steam, and others Range 2: -250 to 250 in H2O (-0.622 to 0.622 bar) Range 3: -1000 to 1000 in H2O (-2.49 to 2.49 bar) Range 3: 0.5 to 800 psia (3447 to 5516 kpa) Range 4: 0.5 to 3626 psia (3447 to 25000 kpa) Range C: 0 to 800 psig (0 to 5516 kpa) Range D: 0 to 3626 psig (0 to 25000 kpa) Compatible with any 100 Ohm Platinum RTD Range 2: -40 to 1200 F (- 40 to 649 C) accuracy ±1.0 F (±0.56 ºC) Range 3: -300 to 1200 F (-184 to 649 C) accuracy ±1.0 F (±0.56 C) Range 4: 1200 to 1500 F (649 to 816 C) accuracy ±0.5 F by each 50 F -40 to 250 F (-40 to 121 C) (Silicon fill) 0 to 185 F (-17.8 to 85 C) (Inert fill)

MULTIVARIABLE SPECIFICATIONS (CONTINUED) Environmental Temperature Limits -40 to 185 F (-40 to 85 C) (Silicon fill) 0 to 185 F (-17.8 to 85 C) (Inert fill) Storage Temperature Limits -50 to 230 F (-46 to 100 C) Humidity 0 100% relative humidity MULTIVARIABLE ACCURACY (Includes the combined effects of linearity, hysteresis and repeatability) Differential Pressure ± 0.075% of the span for spans from 1:1 to 10:1 of the URL. For spans smaller than 10:1 calculate according to: Accuracy = ±[0.025 + 0,005 (URL/Span)]% of span Pressure absolute/static ± 0.075% of the span for spans from 1:1 to 10:1 of the URL. For spans smaller than 10:1, calculate according to: Accuracy = ±[0.03 + 0,0075 (URL/Span)]% of span Temperature Accuracy ±1.0 F (±0.56 C) from -300 to 1200 F (-184 to 649 C) Process Connections Wetted Parts Non-Wetted Parts MULTIVARIABLE CONSTRUCTION MATERIAL Transmitter ¼ 18 NPT on 21/8 centers 1/2 14 NPT on 2, 2⅛, or 2¼ centers with optional flange adapters RTD RTD dependent. Isolating Diaphragms 316L SST or Hastelloy C-276 Drain Vents / Valves 316L SST or Hastelloy C-276 Flanges Plated carbon steel, 316 SST, or Hastelloy C-276 Wetted O-Rings Glass-Filled PTFE Screws Plated carbon steel per ASTM A449, Grade 5 or austenitic 316 SST Fill Fluid Silicone or halocarbon inert oil O-Rings Buna N

Optional Accessories RS-232 Elbow SmartCone Armored RTD Cable Shielded RTD Cable Solar Panel 5-Valve Manifold L-Shaped Mounting Bracket