Pro-Weigh 84/SS/FLP Lo Pro 90 / SS Installation Guide. Version 1.0

Similar documents
INSTALLATION GUIDE. Version 2.0

TS-20KD-1010 LOW PROFILE CARGO SCALE INSTALLATION GUIDE

Model: SS660-OB Stainless Steel Floor Scale Series. Installation, Set-Up and Operation Manual

Model: SS660-PT-R Stainless Steel Poly-Top Floor Scale Series. Installation, Set-Up and Operation Manual

Aegis Heavy Capacity 20K Floor Scale

LOAD CELL TROUBLESHOOTING

Plasma Presenters Cart (PPC-2000)

INS A KSCR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Unpacking the KSCR Splicing the KSCR (If Required)...

INS A KSR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Verify Curb Installation Required Installation Tools...

INSTALLATION INSTRUCTIONS HEAVY DUTY TILT WALL MOUNT Model: PPH-2000

MC CHANGER CABINET INSTALLATION INSTRUCTIONS

MSP-DCCLFSD LCD Flat Screen Swing-Down Mount

HOLE CUTTER SHARPENER ASSEMBLY & SERVICE MANUAL

Horizontal Cable Systems

LCT100. Load Cell Tester User s Guide (v1711) Anyload Transducer Co. Ltd Website:

PART #MSP-DCCST Flat Panel Tilt Mount

INSTALLATION INSTRUCTIONS Flat Panel Static Wall Mount Model: GSM-111

U.S. Rack, Inc Falcon Drive, Madera, CA APR17 INSTALLATION AND USE INSTRUCTIONS for SIDE-MOUNT LADDER RACK

Model MSPPWRTW Large Flat Panel Single Arm Wall Mount

Motorized or Crank Operated Fortress Zipper Track Shade with Housing and Side Track Installation Instructions

400A 40113V, 401A 40120V, & 401AL 40120VL ALUMINUM VERTICAL 4000 LB LIFT INCLUDES SCREW LEG ASSEMBLY INSTRUCTIONS

MK52 Series ULTRA-LOW FREQUENCY VIBRATION ISOLATION WORKSTATION ASSEMBLY AND OPERATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Flat Panel Dual Swing Arm Wall Mount (FWD-110) MSP-SA

MobileTrak5 Installation Instructions

FSD-4100 LCD Flat Screen Swing-Down Mount

PLAYLAND 72 SPIRAL SLIDE 3.5 Posts, 3.5 Posts / 48 Grid and 5 Posts

MPA-9000 Universal Ceiling Projector Mount Kit

340 & 350 SERIES BATH ENCLOSURES

INSTALLATION INSTRUCTIONS Medium Flat Panel Model MSP-SI1

MSP-DCCPGSU Large Screen Static Display Mount

INSTALLATION AND OPERATION MANUAL. Multiple-Radio Interface Module 41021G P-26 (11-12) 2012 David Clark Company Incorporated

Thank you for purchasing our product! *Please read these instructions and follow them step by step.*

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY. 6 3/8" [161.9mm]

MSP-DCCPGTU Large Screen Tilt Display Mount

Installation Instructions

Installation Instructions

Riverside. Windward Bay EntertaInment Wall System Assembly Instructions. Made In Viet Nam. Right Pier. Bridge & Back Panel.

Mount to the Wall INSTALLATION MANUAL

340 & 350 SERIES DELUXE FRAMELESS BYPASS

Hatchback Wing Riser Kit

Model: SCD430 SCD640. Installation & Operation Guide P/N SCD640-95

Installation Instructions

Star Trac Turbo Trainer Assembly & Setup

OPERATION, PARTS & MAINTENANCE MANUAL MODELS HB73-16 HB97-18 HB97-16 HB97-12 HB HB HB HB145-18

Whalen Furniture Mfg. Factory No. 5 Page # 1

UNIT No FRAMELESS PIVOT SHOWER DOOR

IMPULSE G2/PULSE STATIC BRIDGE & RETURN MODULE. Drill. Desk Connecting. Outside by fastening the supplied wood screws from the HK-67 kit through the

ASSEMBLY INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions for Vista Air Vertically Folding Walls

FRONT BUMPER INSTALLATION INSTRUCTIONS Toyota 4Runner

3 11/16" [94.0mm] HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY 6" [152.4mm]

200A FLB VERTICAL 22113V LIFT W/CHAIN DRIVE WINCH

INSTALL INSTRUCTIONS WELCOME TO THE NEWAGE PERFORMANCE CABINETRY SERIES NEWAGE STEEL WELDED CABINETRY

Assembly Instructions for Model: MF110

00108/00110 INSTRUCTION MANUAL

S6 User s Manual USER S MANUAL ver. 1.0

Floating Lake Truss Dock Instructions

Nancy s Knit Knacks LLC 4 Yard Option Upgrade Kit Assembly Instructions and User Manual

Aluminum Sprinter Rack Installation

Pharma-Slide. Installation Manual. [Revision: June 14, 2010, SL150001, Rytec Corporation 2005]

INSTALLATION INSTRUCTIONS FOR FRONT CASTING DECK RAIL Ranger

INSTALLATION INSTRUCTIONS

Installing AZEK Evolutions Rail

Full Height Ladder Safety Gate

Tilting Flat Panel Wall Mount Installation Guide

EmagiKit. Privacy Pod Plus. Quiet. Easy. Affordable. INSTRUCTIONS ASSEMBLY

TITAN INDUSTRIAL RACK 6-FOOT TALL / 4-SHELF

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110

HANDRAIL HEIGHT PER LOCAL CODE AUTORITY

Please read BOTH these Installation Instructions and the General Instructions prior to installing or operating this equipment.

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

ASSEMBLY INSTRUCTIONS

HEAVY DUTY WEIGH FEET KIT. Installation Instructions

INSTALLATION INSTRUCTIONS

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

SAM. Model: STV-C65 LCD Mobile Visualized Stand Instruction Manual. Weight Capacity: 1251bs / 56.7kg Suits LCD Flat Panel Display: 42"-55" Page 20

A4200/A4600 Load Cell Mounting Kit Installation

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY. 6 3/8" [161.9mm]

ClearSpan Mini Cold Frames

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

00108/00110 INSTRUCTION MANUAL

Page 1 of 18. SunRail System Installation Instructions

TITAN INDUSTRIAL RACK 4-FOOT TALL / 3-SHELF

MM340 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

Not including the type of fabric used (clear pvc or shade mesh), there are three main types of side screen.

Medium Flat Panel Dual Swing Arm Wall Mount JWD-V

INSTALLATION INSTRUCTIONS SMALL FLAT PANEL ADJUSTABLE PITCH WALL MOUNT Model: FTR Series

PRODUCT: LOKI INSTALLATION INSTRUCTIONS. Product is covered by U.S. patents. For more information visit

ClearSpan PolyMax Windbreak Wall

CRITICAL INFORMATION:

INSTALLATION AND CARE INSTRUCTIONS

Mobile Cart for Flat Panel Display (PTC-2000 Series)

STORM OUTDOOR TELEVISION MOUNT

ATLANTIS RAIL Contact Information

Freight Door Installation Instructions - HG Series OPENING QUALITY DOORS AROUND THE WORLD. JOB NAME: JOB LOCATION: COURION JOB #:

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

Salter Industries Spiral Stair

Transcription:

Pro-Weigh 84/SS/FLP Lo Pro 90 / SS Installation Guide Version 1.0

INTRODUCTION The scale must not be loaded beyond its capacity. Do not select a site where overweight load would have to maneuver to avoid crossing the platform. Avoid areas where the scale might receive damaging side impacts from wheels, forklift tines, etc., or shock damage from falling objects. Tools Needed Allen wrench (according to base capacity): 1/4" - 1 to 8 k base 3/8" - 10 to 20 k base 9/16" - 30 k+ base Calibrated weights Flat screwdriver Lifting eye bolts (5/8"/11) Site Preparation The interface cable between the scale and the indicator must be secured to the floor or wall. It is suggested to run the load cell cable in conduit to protect against crushing, cutting or moisture damage. In order for the scale to operate properly, it must be level. Either choose a site where the floor is close to this standard to avoid excessive leveling adjustments or modify the floor at the chosen site to meet this standard. Unpacking Remove packing material and inspect scale for any visible damage caused during shipment. If damage did occur, notify your freight carrier immediately to register a claim. Depending on design and packing, some scales are shipped fully assembled. On others, the load feet and the anchor plate option are shipped separately via UPS. The standard unit includes four plastic caps to cover the leveling adjustment holes. Installing Load Feet Screw a load foot into each load cell and turn all the way in until the foot touches the load cell. See Figure 1. Floor Anchor Plate Installation NOTE: Floor plates are only needed when the scale is used with ramps. For drive-on ramp installations, the scale must be secured to the floor to prevent movement. Two anchor plates, with holes that slightly exceed the foot diameter, are included with ramps. Lift the scale so that the feet are approximately 1" off the floor. Slide anchor plates under two diagonally opposed load feet. Lower the scale back to the floor and position the plates so that the bolt down holes are accessible from above. Using the mounting plates as templates, drill pilot holes into the floor for suitable anchor bolts. Bolt the plates to the floor using 1/2" anchor bolts. Recheck foot adjustment and scale levelness after this operation. 1

Note: The overload stop screws are located next to the top access holes for the load feet. These screws are factory set and MUST NOT be adjusted in the field. Field adjustment may damage load cells and will void any and all factory warranties. Above Floor Installation INSTALLATION Place the scale base in the area where it is to be used. Using the Allen wrench, turn each load foot down until base is approximately 1/4" off of the floor all around. Each load foot has an access hole is located on the top of the base. Assure that each load foot is evenly weighted and securely resting on the floor and base is not rocking. CAUTION: If more than 1/2" height adjustment is needed, bottom of load foot must be shimmed. Assure that the load foot bolt is at least halfway in the load cell. At this time, base should be stable and level. Secure the load cell cable/conduit to the floor or wall to assure that it has no influence on the weight reading. Connect scale base to instrument. Load Foot Lock If the scale stays permanently in one place, a jam nut can be used to lock the load feet more securely in place than can be assured by the self-locking feature. See Figure 1. Drive on Ramp NOTE: A drive-on ramp should be installed in line with the load cell direction. 1. Mount anchor plates to the floor as described in the Floor Anchor Plate Installation section. 2. Now position thew ramp a minimum of 1/8" to maximum 1/4" from base and secure to floor using holes provided on side of ramp and 1/2"x 2 1/2" anchor bolts. See Figure 1. NOTE: The ramp or pit frame is to serve by design as a moment stop to prevent excess scale movement caused by sudden stops with drive-on vehicles like fork lifts, etc. Therefore, the clearance between scale deck and ramp or pit frame should be just enough to prevent scale contact. In most cases, 1/8" to 3/16" are sufficient. Excess scale movement can cause premature wear of load feet. Bump Ramp NOTE: Installation of bump ramps is done as the last step of a scale base installation. 1. Place bump ramp in position, assuring a mini-min. of 1/4" clearance from the scale base to avoid any mechanical contact. 2. Secure bump ramp to the floor, using the mounting holes provided and 3/8" anchor bolts. 2

Pit For details of pit construction with a GSE pit frame, please see pit drawing. NOTE: Pit frame must be custom fitted to the scale to assure proper clearance on all sides. 1. Retract load feet into base frame. 2. Lower scale into pit frame. 3. Assure equal clearance between scale and pit frame all around. 4. Use Allen wrench and turn down load feet until scale deck is level with pit frame. CALIBRATION 1. Connect the load cell from the base to the digital indicator. Refer to Table 1 for load cell wiring details. 2. Calibrate base to instrument as per instructions supplied with your instrument. 3. After calibration has been completed, take known weight (25% of capacity) and check each corner. Place weight between center of scale and each corner one at a time as shown below. Use the same calibrated weight in each corner. 4. To adjust corner weight readings, use the trim pot designated for that corner which is numbered the same as the corner you need to adjust. See Figure 1. 5. After each corner has been checked and calibrated, make a final check of your calibration. 6. Enclosed in the scale parts you will find four plastic hole plugs. These are to be placed in the holes directly over the load cell foot. 7. Your GSE floor scale is now ready for use. Table 1 : Home Run Cable Connection Connection Color + Excitation Red - Excitation Black + Signal Green - Signal White + Sense Blue - Sense Brown Shield Clear Figure 1: Load Cell Positions Remote Summing Box The GSE stainless steel floor scales (specifically the PRO-WEIGH 84 SS is equipped with a remote sealed watertight NEMA 4X summing box, attached to the scale platform by USDA approved flexible conduit. The remote summing box provides relief for the electronics from the harsh environments often found in food processing, pharmaceutical and chemical installations. 3

Note that the summing box is designed to be wall or column mounted as far above the floor or pit as possible. Also note that proper operation of the scale, particularly in commercial weighing (legal for trade) applications requires that the summing box be mounted in the same area/environment as the scale platform. The figures on the next page show the installation of a scale platform with a remote summing box. Figure A shows a top-of-floor installation and Figure B shows a pit mounted scale platform. The homerun cable from the remote summing box is a 6-wire cable, 10 feet in length. Wiring to a GSE (or other) digital indicator is shown in Table 1. Mounting Shear Beam Load Cells in Floor Scales When you are replacing a load cell, pay close attention to the orientation of the load cell in regards to the thread. The thread side of the load cell must face the floor to obtain the maximum height adjustment. TROUBLESHOOTING Before testing, it is suggested that each load cell be carefully inspected for physical damage. Testing Zero Balance Changes in zero balance usually occur if the load cell has been overloaded. Some change may be tolerated depending on the application. Use a voltmeter set to millivolts. Measure the load cell output under no load conditions. It should be less than 10% of the full scale output. Testing Bridge Resistance Changes in bridge resistance are most often caused by a failure of a compensating element, a broken bridge or burned bridge. Usually failure is the result of an electrical transient such as lightning. With an ohmmeter, measure the resistance across each pair of input and output leads. The output resistance of the bridge is normally about 350 ohms for single ended beams and canisters and 700 ohms for double-ended load cells. Refer to the calibration certificate shipped with the cell for the actual values. Readings beyond these limits suggest damage and the load cell should be thoroughly inspected. Testing Resistance To Ground Electrical leakage is usually caused by water contamination within the load cells or cables. Whether the leakage can be tolerated depends on the application and electronic instrumentation being used. An unstable output is most often caused by contamination. With a megohmmeter, measure the resistance between all 7 leads tied together (6 live leads and 1 shield) and the load cell body. The reading should be 5000 megohms or more. If the load cell fails this test, remove the ground wire and test with only the 6 live leads. If it test OK, an insulation problem is suspected. 4

LOAD CELL REPLACEMENT Should a load cell become damaged due to an overload condition, replacement load cells can be ordered from GSE Scale Systems according to the part numbers in the chart on page Error! Bookmark not defined.. 1. Unbolt the defective load cell, and then remove leveling load foot from the load cell. 2. Disconnect load cell cable from junction box and attach a chase wire to the load cell cable. DO NOT CUT THE LOAD CELL CABLE! 3. Pull the load cell cable out of the formed frame channels. The chase wire will be used to pull the new load cell cable through the formed channel. 4. Install the new load cell by reversing the preceding steps. 5. To verify correct load cell/junction box terminal matching, see the numbers on the terminals inside the junction box and the corner numbering diagram in Figure 1: Load Cell Positions. 6. Position load cell and torque down with a wrench, tighten all mounting bolts to 75 ft./lbs. 7. Route the load cell cables in each corner so that the cable is free from possible contact with the load cell or load foot. Pull cable tight towards junction box, coil up extra length with cable ties and securely store inside channel. 8. Pass end of load cell cable through cable fittings in the NEMA 4X junction box. Corner correction trimming and calibration is necessary after load cell replacement. Follow the calibration instructions on page 3. Table 2: Replacement Load Cell Wire Color HBM Celtron + Excitation Green Red - Excitation Black Black + Signal White Green - Signal Red White + Sense ---- ---- - Sense ---- ---- Shield Bare Wire Bare Wire 5

Back Cover with part number