SINEAX I 552 Transducer for AC current

Similar documents
SINEAX U 553 Transducer for AC Voltage

SINEAX G 536 Phase Angle or Power Factor Transducer

SINEAX G 537 Transducer for Phase Angle Difference

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

EMBSIN 281 G Power factor transducer

SINEAX TV809, 1 channel Programmable Isolating Amplifier

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

SINEAX B 811 Power Pack with additional Functions

Theta 20A / 20V. Technical Data Sheet. Special Features

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

Plug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

SINEAX TI 807 Passive DC signal isolator

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

EURAX UI 505, Combined Transducer for AC current and AC voltage

RISH Ducer E13 3 channel transducer for AC current and voltage

Theta Hz. Technical Data Sheet. Special Features

KINAX 2W2 Programmable Transmitter for Angular Position

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

KINAX WT 717 Programmable Transmitter for Angular Position

SINEAX V 604s Programmable multifunctional transmitter

Plug-in module SIRAX TI 807 Passive DC signal isolator

RISH Ducer E15 TRANSDUCER FOR AC CURRENT OR AC VOLTAGE WITH DIFFERENT CHARACTERISTICS

KINAX SR 719 Programmable Transmitter for Position Feedback

RISH Ducer E13 Transducer For Ac Current Or Ac Voltage With Different Characteristics

SINEAX V604s Programmable multifunctional transmitter

SINEAX / EURAX 2I1 Passive DC signal isolator

SINEAX VC 603, Programmable combined transmitter/alarm unit

ZIEGLER PRO-P Power / Phase Angle / Power Factor Transducer

KINAX 3W2 Transmitter for angular position

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

Data Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2

SUBJECT TO CHANGE WITHOUT NOTICE

SINEAX V 604 Programmable universal transmitter

KINAX WT 707 Transmitter for angular position

Coupling Relays and Converters

POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL

Programmable AC Voltage Transducer MT416

Programmable AC Current Transducer MT418

EA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters

VariTrans P D1 TRMS

ZITARES CCD FX-20 25W SELV (isolated), adjustable functions and current, 1-channel, dimmable

for DC currents or voltages, temperature sensors, remote sensors or potentiometers II (1) G Application Features / Benefits

Fluke 83V and 87V Digital Multimeters

Rudder or propeller angular position transmitter KINAX WT720

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

DATA SHEET AC current single function transducer TAC-311DG/TAC-321DG

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

MBS AG EMBSIN 120 UV. without auxiliary voltage supply housing for 35 mm DIN rail mounting

It s TRUE! True RMS measurement with the new AC/DC high-voltage transmitters of the VariTrans P TRMS series. Isolation Amplifiers.

CP-E range Benefits and advantages

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv

Zelio Control Measurement Relays

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions

DATA SHEET Selectable AC transducer TAS-311DG

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

CP-T range Benefits and advantages

SEPARATOR P20G TYPE USER S MANUAL

Product Guide. Transducers

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

Isolators A3/1. Vibration Transducer Supply Unit Series

CP-T range Product group picture

Thermistor motor protection relays

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

ZITARES NCD FX-30 Non-SELV (isolated), constant current control gear, 1-channel, dimmable

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Power consumption In operation At rest For wire sizing

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P TRMS

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

RISH Ducer IXX / VXX Series (TRMS/Average) Transducer for AC current / AC Voltage (Single or Dual Output)

ZITARES NCD FX-30 Non-SELV (isolated), constant current control gear, 1-channel, dimmable

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P TRMS

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device

Digital I/O Coupler (4-wire) Series 9413/21

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

ZITARES ICD SELV constant current control gear, 2-channel, dimm- and programmable

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

VariTrans P V. Safe and Sound.

Analog signal converters CC range

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

For non-electrical quantities

Extension for ground plate Z-SMA. Shaft extension AV8-25. Reversible spindle clamp K-SA. Damper crank arm KH8. Extension from SM.. or AM.. to SM..A..

USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2

ZITARES ICD SELV constant current control gear, 2-channel, dimm- and programmable

27/04/2015

Paladin Transducers 250 Series Class 0.5 and Class 0.2

Isolating Repeater Input Series 9163

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR

Transcription:

SNEAX 55 With power supply RMS value measurement, with measuring ranges Carrying rail housing P/0 Application he transducer SNEAX 55 (Fig. ) converts a sinusoidal or a distorted AC current into a load independent DC current or a load independent DC voltage proportional to the measured value. he transducer fulfi ls all the important requirements and regulations concerning electromagnetic compatibility EMC and Safety (EC 00 resp. EN 00). t was developed and is manufactured and tested in strict accordance with the quality assurance standard SO 00. Fig.. ransducer SNEAX 55 in housing P/0 clipped onto a top-hat rail. Features / Benefits Measuring input: AC current, sine or distorted wave forms, RMS value measurement Measured variable AC current Measuring range limits 0 0. / 0.5 to 0. / A Measuring output: Unipolar or live zero output variables Measuring principle: Logarithmic method AC/DC power supply / Universal Standard version as per Germanischer Lloyd Following fi ltration by means of an active fi lter, the transformation properties of the measuring transducer are determined in the succeeding characteristics circuit. he output amplifi er transforms the measuring signal into an impressed DC current output signal A. he electronic components are supplied with voltage H from the mains supply unit. ~ H eff = i dt o A Mode of operation nput signal ~ is galvanically separated from the mains network using a transformer. he following mathematical expression is then formed using a root-mean-square value computer eff = o i dt Fig.. Block diagram. echnical data General Measured quantity: Measuring principle: AC current Sine or distorted wave forms RMS value measurement Logarithmic method Camille Bauer Data sheet 55 Le 0.0

SNEAX 55 Measuring input E Nominal frequency f N : 50/0 or 400 Hz Nominal input current N (measuring range end value): Measuring range limit values 0 0. / 0.5 to 0 <. / A Measuring range end value ratio : 5 Setting: Own consumption: Overload capacity: Admissible alteration of full scale output, variable sensitivity, adjustable with potentiometer Setting range 0.5.5 N (± 5%) 00% 0Output N 0 nput 0.5.5 VA with input end value Measured Duration of nterval between Number of quantity one two successive applications N application applications. N continuously 0 N 0 s 00 s Measuring output A Load-independent DC current: Burden voltage: 0 to 0 0 ma resp. live-zero 0. to 4 0 ma 5 V 5 V External resistance: R ext max. [kω] = AN [ma] AN = Output current end value Load-independent DC voltage: 0 to 0 0 V resp. live-zero 0. to 0 V External resistance: R ext [kω] U [V] A ma Current limit under overload: Voltage limit under R ext = : 5 V.5 AN at current output Approx. 0 ma at voltage output Residual ripple in output current: Setting time: 0.5% p.p. at setting time 00 ms % p.p. at setting time 50 ms 50 ms or 00 ms Power supply H AC/DC power pack (DC or 40 400 Hz) able : Rated voltages and permissible variations Rated voltage olerance 5 0 V DC / AC DC 5 + % 4 0 V DC / AC AC ± 5% Option: Power consumption: Accuracy (acc. to EN 0 ) Reference value: Connected to the low tension terminal side and 4 V AC or 4 0 V DC.5 W resp. VA Output end value Basic accuracy: Class 0.5 Reference conditions: Ambient temperature 5 0 C nput variable Rated operating range Frequency f N ± Hz Curve shape Sine-wave Crest factor Power supply n rated range Output burden Current: 0.5 R ext max. Voltage: R ext min. Warm-up time 5 min. nfluence effects (maxima): included in basic error Frequency 40 400 Hz, ± 0.% 0 000 Hz, ± 0.5% Crest factor.5 ± 0.% >.5 ± 0.5% Safety Protection class: (protection isolated, EN 00) Housing protection: P 40, housing (test wire, EN 0 5) P 0, terminals (test fi nger, EN 0 5) Contamination level: Overvoltage category: Rated insulation voltage 00 V, input (versus earth): 0 V, power supply 40 V, output Data sheet 55 Le 0.0 Camille Bauer

SNEAX 55 est voltage: 50 Hz, min. acc. to EN 00-00 V, input versus all other circuits as well as outer surface 00 V, power supply versus output as well as outer surface 40 V, output versus outer surface Storage temperature: 40 to + 0 C Relative humidity of annual mean: 5% Altitude: 000 m max. ndoor use statement! nstallation data Mechanical design: Housing P/0 Material of housing: Lexan 40 (polycarbonate), fl ammability Class V-0 acc. to UL 4, self-extinguishing, non-dripping, free of halogen Mounting: Mounting position: Weight: Connecting terminals Connection elements: Permissible cross section of the connection leads: Environmental conditions For rail mounting Any Approx. 0. kg Screw-type terminals with indirect wire pressure 4.0 mm single wire or.5 mm fi ne wire Operating temperature: 0 to + 55 C Ambient tests EN 0 0--: Acceleration: Frequency range: Number of cycles: EN 0 0--: Acceleration: EN 0 0--/-/-: EC 000-4-/-/-4/-5/- EN 55 0: Germanischer Lloyd ype approval certifi cate: Ambient category: Vibration: Vibration ± g 0 50 0 khz, rate of frequency sweep: octave/minute 0, in each of the three axes Shock x 50 g shocks each in directions Cold, dry heat, damp heat Electromagnetic compatibility No. 5- HH C 0. g able : Standard version he following transducer version is available as standard version. t is only necessary to quote the Order No.: Nominal frequency Measuring range by changing connections Output signal Power supply DC or 40 400 Hz Setting time Order No. 50/0 Hz 0.0 A / 5 A 4 0 ma 5 0 V 00 ms 0 he complete order code 55-4..... according to able : Specifi cation and ordering information must be stated for versions other than the basic version and for special confi gurations. able : Specification and ordering information (see also able : Standard version) Description *Blocking code No-go with blocking code Article No./ Feature SNEAX 55 Order Code 55 - xxxx xx 55 Features, Selection. Mechanical design Housing P/0 for rail mounting 4. Nominal input frequency 50 / 0 Hz 400 Hz Camille Bauer Data sheet 55 Le 0.0

SNEAX 55 Description *Blocking code No-go with blocking code Article No./ Feature SNEAX 55 Order Code 55 - xxxx xx 55 Features, Selection. Measuring range 0 / 5 A 0. / A Non-standard 0 0./0.5 to 0 <. / Measuring range end value ratio : 5 4. Output signal [A] 0 0 ma, R ext 50 Ω 4 0 ma, R ext 50 Ω Non-standard 0.00 to 0 < 0 0. to < (4 0) [ma] 0 0 V, R ext 5 kω A Non-standard 0.00 to 0 < 0 0. to 0 5. Power supply [V] Z 5 0 V DC/AC 4 0 V DC/AC 4 V AC / 4 0 V DC, low tension 5. Setting time 0. s 50 ms * Lines with letter(s) under «no-go» cannot be combined with preceding lines having the same letter under Blocking code. Electrical connections Fig.. For measurement with st (lower) measuring range, power supply connected to terminals and. Fig. 4. For measurement with nd (higher) measuring range, power supply connected to terminals and. 0 0 ( )(+) ( )(+) 4 Data sheet 55 Le 0.0 Camille Bauer

SNEAX 55 ( )(+) Fig. 5. For measurement with st (lower) measuring range, power supply connected to the low tension terminal side and. ( )(+) Fig.. For measurement with nd (higher) measuring range, power supply connected to the low tension terminal side and. 0 0 = Current measuring input = Measuring output = Power supply Dimensional drawing.5 0. 4. 0 Fig.. SNEAX 55 in housing P/0 clipped onto a top-hat rail (5 5 mm or 5.5 mm, acc. to EN 50 0). Rely on us. Camille Bauer AG Aargauerstrasse CH-50 Wohlen / Switzerland Phone: + Fax: + 5 5 e-mail: info@camillebauer.com www.camillebauer.com Subject to change without notice Edition 0.0 Data sheet 55 Le