Modified Peripheral Iris Fixation of a Foldable Intraocular Lens Following Phacoemulsification

Similar documents
Sutureless, Glueless, Scleral Fixation of Single-Piece and Toric Intraocular Lens: A Novel Technique

THE NEXT BIG THING IN SCLERAL HAPTIC FIXATION

Sutureless Trocar-Cannula Based Transconjunctival Flanged Intrascleral Intraocular Lens Fixation

EXCHANGE. Financial Disclosure. Clinical pearls In advanced anterior segment surgery being able to do a IOL exchange is a must. Why Do an Exchange

Intraocular lens Difficulties

PreciSAL Preloaded Lens System

Techniques for sulcus fixation of single-piece acrylate iols

Scleral Fixated Intraocular Lens

Clinical Evaluation 3-month Follow-up Report

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs

The design is distinctive. The outcomes are clear. Defocus tolerance 1 Glistening-free performance 1,2 Predictable outcomes 1

*Simulated vision. **Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs. Your skill. Our vision.

Sulcoflex. For when perfection is the only option! Pseudophakic Sulcus Fixated Secondary IOLs. Sulcoflex Aspheric. Sulcoflex Toric

Causes of refractive error post premium IOL s 3/17/2015. Instruction course: Refining the Refractive Error After Premium IOL s.

IOL Types. Hazem Elbedewy. M.D., FRCS (Glasg.) Lecturer of Ophthalmology Tanta university

The procedure was nearly complete. I was

AHEAD Superior technology, thoughtfully designed with you in mind for an intelligent approach to cataract surgery.

Long-term quality of vision is what every patient expects

NOW. Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers. Accommodating. Aberration Free. Aspheric.

Intrascleral sutureless intraocular lens (IOL) fixation was started

implantation Marvin L Kwitko, MD Artificial lens

The Dysphotopsia Mystery. John J. Bussa, M.D.

FEA of Prosthetic Lens Insertion During Cataract Surgery

Clinical Evaluation 3-month Follow-up Report

THE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES.

Dr. Magda Rau Eye Clinic Cham, Germany

ROTATIONAL STABILITY MAKES THE DIFFERENCE

LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs

Microsurgical Suturing Techniques: Closure of the Cataract Wound

edge of the section wound, probably from opening of the wound

LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs

Not everyone can do this. Introducing RayOne with patented Lock & Roll TM technology for the smallest fully preloaded IOL incision

Unique Aberration-Free IOL: A Vision that Patients

COMPARISON OF THE MEDICONTUR 860FAB

Raise your expectations. Deliver theirs.

GETTING STARTED WITH DMEK

Multifocal and Accommodative

Visual Outcomes of Two Aspheric PCIOLs: Tecnis Z9000 versus Akreos AO

IOL Review and FLACS Update

Special Publication: Ophthalmochirurgie Supplement 2/2009 (Original printed issue available in the German language)

PRE-PLACED VERSUS POST-PLACED CORNEO-SCLERAL

Maximising Treatment Outcomes with Premium IOL Technology. Saturday 13 September 2014 XXXII Congress of the ESCRS London, UK.

Virtual Reality Phacoemulsification: a Comparison Between Skilled Surgeons and Students Naive To Cataract Surgery

Evolution of Diffractive Multifocal Intraocular Lenses

The complete choice in refractive lens solutions

GLUED IOL BROKEN for POSTERIOR CAPSULE

Contents. Corneal Markers, Scleral Depressors

WORLD S LEADING CATARACT TECHNOLOGY FOR SMALL INCISION. Small Incision Small Incision to serve surgeon s cataract technique

Comparison of higher order aberrations with spherical and aspheric IOLs compared to normal phakic eyes

Amico Yasna Pars. What s Inside. Leader in Healthcare Specialty Markets. Ophthalmology Newsletter.

Vision for What They Love.

Improving Lifestyle Vision. with Small Aperture Optics

Choosing the Proper Power for the IOL. Brannon Aden, MD Miles H. Friedlander, MD, FACS

Aberrations Before and After Implantation of an Aspheric IOL

Patient information. Your options for cataract treatment Enjoy clear vision at all distances with multifocal IOLs

Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert

Glistening-Free Hydrophobic Acrylic IOL. Glistening-Free Hydrophobic Acrylic IOL

Advanced Technology IOLs

Evolution of the Cataract Patient

USE OF THE PUPILLARY LENS (IRIS CLIP LENS) IN APHAKIA*

OPHTHALMIC SURGICAL MODELS

DEFECTS OF VISION THROUGH APHAKIC SPECTACLE LENSES*t

UIN: IOL Date of Prep: April Avansee Preload1P. Technical Slide Kit April 2017

Comparison of Visual Performance with Photochromic, Yellow and Clear Intraocular Lenses

Lens Regeneration in Juvenile and Adult Rabbits Measured by Image Analysis

OPHTHALMIC SURGICAL MODELS

Irregular Cornea. ROSE K2 Soft TM. Practitioner s Fitting Guide

Comparative Study Between the High Order Aberrations Before and After Cataract Surgery Using Two Different Types of IOLS

Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN

day night convinced supreme contrast sensitivity THE IOL FOR DAY & NIGHT

HYDROPHILIC ACRYLIC ADVANCED POLYMER

ARTIFICIAL PSEUDOPHAKIA* followed-up for at least 2 post-operative years, are described below. Later TABLE PARTICULARS OF

Please feel to contact Sonomed for any suggestions, comments or request about this bulletin.

Customized intraocular lenses

TrHE CORNEO-SCLERAL SUTURE*

PRODUCT CATALOGUE Sterile Single Use Instruments for Cataract and Vitreoretinal Surgery

Akreos AO Intraocular Lens

What s Fundus photography s purpose? Why do we take them? Why do we do it? Why do we do it? Why do we do it? 11/3/2014. To document the retina

SOFT (HYDROPHILIC) CONTACT LENSES DAILY WEAR FOR PLANNED REPLACEMENT OR DAILY DISPOSABLE. PRACTITIONER FITTING GUIDE July 2009

RayOne Hydrophobic IOL. New design. New standard MADE IN UK

Choices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12

AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients

Treatment of Presbyopia during Crystalline Lens Surgery A Review

Newsletter Spring 2015

Cataract Information. victoriaeye.com

ABO Certification Training. Part I: Anatomy and Physiology

12 10) Patent No.: US 8.663,235 B2. Tassignon (45) Date of Patent: Mar. 4, 2014 (54) BAG-IN-THE-LENS INTRAOCULAR LENS FOREIGN PATENT DOCUMENTS

FOR PRECISE ASTIGMATISM CORRECTION.

Multifocal Intraocular Lenses for the Treatment of Presbyopia: Benefits and Side-effects

Accommodating IOL s History and Clinical Management

THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening

Gonioscopy Wet-Lab. About Me. About Me Gonioscopy. Indications for Gonioscopy. Billing Gonioscopy 12/13/2012. Code: 92020

NEW. AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients

case report Scleral lens fit based on OCT data

Anterior and Posterior Axial Lens Displacement and Human Aqueous Outflow Facility

Corporate Perspective Alcon Unanswered Technical Challenges that Still Need to be Overcome

COMMUNICATIONS. London. EXTRACTION of the human lens for cataract has been performed with various

EXPAND YOUR VIEW. SUSTAIN YOUR ACCESS. OASIS IRIS EXPANDER DESIGNED FOR SAFETY & EFFICIENCY. PREMIER EDGE SAFETY SCALPELS SAFETY CRESCENT SCALPEL

Technicians & Nurses Program

Transcription:

C A S E R E P O R T Modified Peripheral Iris Fixation of a Foldable Intraocular Lens Following Phacoemulsification Jia-Kang Wang, Pei-Ching Lai* In this report, we describe the case of an aphakic patient who underwent peripheral iris fixation of a foldable posterior chamber intraocular lens (IOL) in the absence of capsular support. The patient suffered from traumatic cataract with partial zonular dehiscence. He received phacoemulsification, and capsular rupture occurred subsequently. After complete anterior vitrectomy, the lens capsule disappeared completely. Six months later, secondary IOL implantation was performed. A clear corneal incision was made, and a paracentesis was created to insert a folded acrylic soft IOL and a temporary supporting device. The optic of a three-piece acrylic IOL was folded along the axis of the haptics, and both the haptics were bent and quickly maneuvered into the folded furrow of the optic. A bimanual unfolding maneuver created pupillary capture of the optic for stabilization and centration of the IOL, with the haptics expanding on the back surface of the iris, and the haptics were fixated to the peripheral iris with modified McCannel suturing. Fair visual outcome without complications was noted. KEY WORDS capsular support, foldable acrylic intraocular lens, modified McCannel suturing, modified peripheral iris fixation technique J Med Ultrasound 2005;13(2):79 84 Introduction Implantation of an intraocular lens (IOL) in the absence of capsular and zonular support is a challenge to the ophthalmologist. The options for implantation include the insertion of an anterior chamber (AC) IOL, a scleral-fixated posterior chamber (PC) IOL, or an iris-fixated PC IOL. Implantation of an AC IOL is easy to manipulate, but corneal decompensation, glaucoma, chronic inflammation, and associated complications may result in visual impairment [1]. Because fixation sutures are blindly passed through the highly vascular ciliary body, intraocular hemorrhage and tilting of the lens may occur following transscleral fixation of a PC IOL [2]. In a previous study, transscleral fixation caused IOL tilt in 10% of patients because of the different levels of fixation between the two haptics [2]. Using Department of Ophthalmology, Far Eastern Memorial Hospital, Taipei, Taiwan, R.O.C. *Address correspondence to: Dr. Pei-Ching Lai, Department of Ophthalmology, Far Eastern Memorial Hospital, 21, Nan-Ya South Road, Section 2, Pan-Chiao, Taipei 220, Taiwan, R.O.C. E-mail: jiakangw@yahoo.com.tw Elsevier & CTSUM. All rights reserv ved. J Med Ultraso ound 20 005 Vol 13 No 2 79

J.K. Wang, P.C. Lai ultrasound biomicroscopic analysis, it was found that in 54 of 86 (62.8%) patients receiving scleralfixated IOLs, the haptics were not seen on the ciliary sulcus [3]. In another report, transscleral fixation resulted in one vitreous hemorrhage and two hyphemas in 32 patients, which were caused by inadvertent trauma to the ciliary body or iris root [4]. Besides, scleral sutures can serve as conduits between the exterior and the interior of the eye, increasing the risk of late endophthalmitis [5]. In recent studies, iris fixation of a foldable PC IOL provided a safe and effective way to implant an IOL without capsular support in aphakic patients [6,7]. This novel method not only avoided complications caused by the above-mentioned AC IOL and scleral-fixated PC IOL, but also prevented adverse effects of the large limbal wound. This limbal wound is needed to implant a rigid IOL. A small self-sealing clear corneal incision was made to insert a folded acrylic soft IOL. A bimanual unfolding maneuver created pupillary capture of the optic to temporarily stabilize the IOL, with the haptics expanding on the back surface of the iris and being fixated to the peripheral iris with modified Mc- Cannel sutures [8]. In this report, the previous procedure was modified, performing fewer paracenteses and changing the folding pattern of the IOL. This modified technique shortened operation time and reduced the probability of postoperative complications. of +11.5/ 0.5 180. Examination of the anterior segment, posterior segment, and intraocular pressure did not reveal any abnormalities. After obtaining the patient s consent, secondary implantation of an IOL was performed. Phenylephrine 5% eye drops (Neosinicin ; Oasis, Taipei, Taiwan) was used for mid-dilation of the pupil. A retrobulbar block was performed prior to a 3.5-mm temporal clear-cornea incision. Sodium hyaluronate 3% and sodium chondroitin sulfate 4% (Viscoat ; Alcon Laboratories, Fort Worth, TX, USA) were injected for the deepening of the AC, as a precaution to avoid pupillary expansion. More viscoelastic material was placed behind the pupillary plane to tamponade vitreous prolapse. A 1.0-mm peripheral paracentesis incision was made at the 10 o clock position, 150 from the corneal incision. The optic of a three-piece soft acrylic IOL (ACRYSOF ; Alcon Laboratories) was folded along the axis of the haptics, i.e. at the 6 12 o clock meridian. Both the haptics were bent and temporarily inserted into the folded furrow of the optic (Figs. 1 and 2). The folded IOL was inserted at the level of the iris (Fig. 3). The optic fold was relaxed to some extent, and a phaco spatula (Katena Products, Danville, NJ, USA), with the tip pointing downward, was passed through the opposite paracentesis and gently placed under the folded optic (Fig. 4). The IOL was slowly Case Report A 45-year-old patient suffered from traumatic cataract with phacodonesis and partial zonular dehiscence. Capsular rupture occurred during phacoemulsification. The wound was extended, and the lens fragments were removed with a lens loop. Anterior vitrectomy was performed to remove residual cortex and prolapsed vitreous. The lens capsule was also eliminated completely due to severe disfiguration of the remnant capsule. Aphakia was noted postoperatively. Six months later, best-corrected visual acuity (BCVA) was 12/20 with a correction Direction of fold Haptics inserted into furrow Fig. 1. The optic of a three-piece soft acrylic intraocular lens was folded along the axis of the haptics. 80 J Med Ultrasound 2005 Vol 13 No 2

Iris Fixation of Intraocular Lens (Fig. 6). The sutures were knotted, and the suture ends were trimmed after gentle retraction of the knots nearly out of the corneal wounds (Fig. 7). The sutures fixated the haptics to the peripheral iris. The optic was positioned in the plane under the iris by McPherson forceps. The viscoelastic material was washed out with gentle irrigation and aspiration. The corneal wound was left sutureless without wound leakage. Fig. 2. The leading haptic was bent into a loop and inserted into the groove of the folded optic. Fig. 4. A phaco spatula, passed through the paracentesis, was gently placed under the folded optic to support the optic above the iris plane. Fig. 3. The folded intraocular lens with the loop of the haptic was placed into the chamber. unfolded, allowing the haptics to extend behind the posterior iris surface, while the optic, supported by the spatula above the iris plane, was completely captured by the pupil and stabilized. The spatula was then removed. Two modified McCannel-type iris-fixation sutures were made through the paracentesis and corneal incisions, using 10-0 polypropylene suture material on long, curved needles (Ethicon CIF-4; Ethicon, Somerville, NJ, USA). After inserting the needle into the chamber from one side of the corneal incision or paracentesis, the tip was passed through the peripheral iris, behind the haptic, and out through the iris and peripheral cornea on the other side of the corneal wound (Fig. 5). Both suture ends were retrieved from the corneal incision and the paracentesis with a Sinskey hook Fig. 5. After the needle was inserted into the chamber from one side of the corneal incision, its tip was passed through the peripheral iris, behind the haptic, and out through the iris and peripheral cornea on the other side. The intraocular lens was stabilized by pupillary capture of the optic, and the placement resulted in pupil ovalization. J Med Ultraso ound 20 005 Vol 13 No 2 81

J.K. Wang, P.C. Lai Fig. 6. Both suture ends were retrieved from the corneal incision with a Sinskey hook. Fig. 7. After the sutures were knotted, the suture ends were gently pulled to the corneal incisions for trimming. Postoperative medications included topical gentamicin and dexamethasone for 2 3 weeks until the reaction in the AC vanished. Seven months after operation, BCVA was 14/20 with a correction of 0.5/ 0.75 180, with a keratometric reading of 0.75 180. The patient was satisfied with the visual results and experienced no discomfort. Discussion Iris fixation of PC IOLs in the eyes of patients without capsular support has been reported, mostly during penetrating keratoplasty [9 11]. Fixation of the lens optic to the posterior aspect of the midperipheral iris using polypropylene sutures inserted through the lens positioning holes has provided satisfactory results in studies that included hundreds of patients [9,10]. This technique also avoids the side effects caused by the implantation of an AC IOL or scleral-fixated PC IOL, and permits the optical correction to be brought closer to the nodal point of the eye. In a large randomized trial of IOL fixation techniques during penetrating keratoplasty in 176 patients, Schein et al found that iris fixation was the best tolerated of the investigated methods in supporting a PC IOL in the absence of lens capsule support [12]. The risk of an adverse outcome (such as glaucoma, cystoid macular edema, IOL dislocation, graft failure) was significantly less for the iris fixation group than for either the AC IOL or scleral fixation group. However, late breakage of fixational polypropylene sutures with iris-fixated lenses has occurred in five out of 97 cases after a mean follow-up of 112 months [13]. It was hypothesized that the fixation sutures were eroded by the sharp edge of a positioning hole located on the IOL optic. In addition, some restriction of pupillary motility may stem from traditional four-point iris fixation. The papers by Stutzman and Stark [6], Condon [7], and this present report have described another method for iris fixation of a PC IOL during its secondary implantation, which consists of pupil entrapment of the lens optic in the AC, placement of the lens haptics behind the iris, and securing the IOL with modified McCannel sutures to the peripheral iris. The new procedure avoids possible future suture breakage because the sutures are fixed to a smooth polymethylmethacrylate haptic. There was no suture breakdown or loosening during shortterm follow-up in this and previous reports [6,7]. The peripheral iris is relatively immobile, which allows a firmer adhesion of the haptics, without affecting pupillary movement. The planes of the optic and pupil were parallel following the fixation of the PC IOL to the iris. As in the previous reports [6,7], we found that the postoperative amount of 82 J Med Ultrasound 2005 Vol 13 No 2

Iris Fixation of Intraocular Lens manifest astigmatism was nearly equal to that of keratometric astigmatism, which substantially proved the absence of lens tilt; there were also no major complications such as intraocular hemorrhage or infection. Traditionally, more than a 7-mm long limbal wound is needed for rigid IOL insertion, predisposing patients to intraoperative and postoperative complications. Hypotony, even expulsive hemorrhage, is a reported complication of traditional cataract surgery or secondary IOL implantation involving an 8- to 12-mm incision [2]. Astigmatism and a higher incidence of macular edema also occurred after implantations requiring large limbal openings [14]. When a foldable IOL is used, whose implantation requires only a 3.5-mm sutureless wound, complications associated with a large wound are avoided. The methods of iris fixation described in the previous reports [6,7] were modified in two ways: the number of paracenteses was reduced and the IOL folding procedure was changed. Only one paracentesis was required in this case, instead of three separate paracenteses that were previously reported. The use of fewer corneal entry sites reduced the time required for operation and the probability of wound-related complications, such as wound leakage, formation of flat chambers, and intraocular infection. Because the procedure used only one paracentesis for IOL insertion, the IOL had to be folded along the axis of the haptics, in contrast to the mustache pattern of IOL folding used previously [6,7]. The flexibility of the threepiece ACRYSOF haptics led, at times, to twisting during IOL insertion and impeded further advancement into the plane under the iris while in contact with the pupillary edge. Moreover, rotation or pronation of the haptic was needed to position it in the retropupillary space. Both haptics were bent and inserted into the folding groove of the optic before IOL placement, which facilitated smooth and quick implantation of the haptics behind the iris. This modified technique also saved operating time. While performing the previously described technique [6,7] on another aphakic patient, 45 minutes were needed for the entire procedure, but only 30 minutes were needed to complete the operation in this case with the modified technique. We have described a modified peripheral iris fixation of a foldable PC IOL for use in patients requiring secondary IOL implantation without capsular support. The method involves only a small corneal incision and avoids complications associated with the implantation of AC IOLs and scleralfixated PC IOLs. As operating time and the number of necessary paracenteses are reduced, this modified procedure is also more efficient and safer than previously described techniques. The patient was satisfied with his vision and experienced no complications. References 1. Amino K, Yamakawa R. Long-term results of out-ofthe-bag intraocular lens implantation. J Cataract Refract Surg 2000;26:266 70. 2. Solomon K, Gussler JR, Gussler C. Incidence and management of complications of transsclerally sutured posterior chamber lenses. J Cataract Refract Surg 1993; 19:488 93. 3. Manabe S, Oh H, Amino K, et al. Ultrasound biomicroscopic analysis of posterior chamber intraocular lenses with transscleral sulcus suture. Ophthalmology 2000;107: 2172 8. 4. McCluskey P, Harrisberg B. Long-term results using scleral-fixated posterior chamber intraocular lenses. J Cataract Refract Surg 1994;20:34 9. 5. Schechter RJ. Suture-wick endophthalmitis with sutured posterior chamber intraocular lenses. J Cataract Refract Surg 1990;16:755 6. 6. Stutzman RD, Stark WJ. Surgical technique for suture fixation of an acrylic intraocular lens in the absence of capsule support. J Cataract Refract Surg 2003;29: 1658 62. 7. Condon GP. Simplified small-incision peripheral iris fixation of an AcrySof intraocular lens in the absence of capsule support. J Cataract Refract Surg 2003;29: 1663 7. 8. McCannel MA. A retrievable suture idea for anterior uveal problems. Ophthalmic Surg 1976;72:98 103. 9. Price FW Jr, Whitson WE. Visual results of suturefixated posterior chamber lenses during penetrating J Med Ultraso ound 20 005 Vol 13 No 2 83

J.K. Wang, P.C. Lai keratoplasty. Ophthalmology 1989;96:1234 40. 10. Soong HK, Musch DC, Kowal V, et al. Implantation of posterior chamber intraocular lenses in the absence of lens capsule during penetrating keratoplasty. Arch Ophthalmol 1989;107:660 5. 11. Zeh WG, Price FW Jr. Iris fixation of posterior chamber intraocular lenses. J Cataract Refract Surg 2000;26: 1028 34. 12. Schein OD, Kenyon KR, Steinert RF, et al. A randomized trial of intraocular lens fixation techniques with penetrating keratoplasty. Ophthalmology 1993; 100:1437 43. 13. Price FW Jr, Whitson WE, Collins K, et al. Changing trends in explanted intraocular lenses: a single center study. J Cataract Refract Surg 1992;18:470 4. 14. Wang JK, Lai PC. Unusual presentation of angle closure glaucoma treated by phacoemulsification. J Cataract Refract Surg 2004;30:1371 3. 84 J Med Ultrasound 2005 Vol 13 No 2