QUALITY CONTROL PHANTOMS FOR RADIOTHERAPY AND MEDICAL IMAGING

Similar documents
QUALITY CONTROL SOFTWARE FOR RADIOTHERAPY AND MEDICAL IMAGING

CHAPTER 2 COMMISSIONING OF KILO-VOLTAGE CONE BEAM COMPUTED TOMOGRAPHY FOR IMAGE-GUIDED RADIOTHERAPY

A positioning QA procedure for 2D/2D (kv/mv) and 3D/3D (CT/CBCT) image matching for radiotherapy patient setup

GafChromic QuiCk Phantom with EBT3P/3+P Film and FilmQA Pro for Radiation Therapy Dosimetry Applications

COMPREHENSIVE TG-142 IMAGING AND MACHINE QA

8/3/2017. Use of EPIDs for Non-Routine Linac QA. Disclosure. Learning Objectives. Parts of this project received support from Varian Medical System.

The Current State of EPID-Based Linear Accelerator Quality Assurance. Disclosures. Purpose of this First Talk 8/3/2017

C a t p h a n. T h e P h a n t o m L a b o r a t o r y. Ordering Information

Isocenter and Field of View Accuracy Measurement Software for Linear Accelerator

Nathan Childress, Ph.D., DABR

ISO Cube Daily QA Package

Performance evaluation of the RITG148 + set of TomoTherapy quality assurance tools using RTQA 2 radiochromic film

ISPFILMQATM STATE-OF-THE-ART RADIOTHERAPY VERIFICATION SOFTWARE. Supports all major radiotherapy technologies! FilmQA TM

I. PERFORMANCE OF X-RAY PRODUCTION COMPONENTS FLUOROSCOPIC ACCEPTANCE TESTING: TEST PROCEDURES & PERFORMANCE CRITERIA

A device for precision positioning and alignment of room lasers to diminish their contribution to patient setup errors

Development of the Use of Amorphous Silicon (ASi) Electronic Portal Imaging Devices as a Physics Tool for Routine Linear Accelerator QA

7/23/2014. Acknowledgements. Implementing a new digital medical accelerator. New Generation of Medical Accelerators

Sub-mm accuracy of accelerators: How manufacturers achieve it, how physicists verify it

CT Scanner Dose Survey

DOSELAB TOMOTHERAPY TG-148 QA QUICK GUIDE TG-148 RECOMMENDED TESTS 1. V.B.1.C. - Y-JAW DIVERGENCE/BEAM CENTERING

Quality control of Gamma Camera. By Dr/ Ibrahim Elsayed Saad 242 NMT

LASER SYSTEMS FOR PATIENT MARKING AND POSITIONING

QC Testing for Computed Tomography (CT) Scanner

Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy

PHYSICS QUESTIONNAIRE FORM

Chapter 3. Material and Methods

Engineering Working Drawings Basics

specifications TrueBeam STx System

specifications TrueBeam System

MOVING LASER SYSTEMS IN RT

Test Equipment for Radiology and CT Quality Control Contents

Monte Carlo study on a new concept of a scanning photon beam system for IMRT

Nuclear Associates

International Journal of Advance Engineering and Research Development

Laser Installation Engineers, CT Room Designers and Contractors

Phantoms in Medical Physics (RT) U. Oelfke. Division of Radiotherapy & Imaging

A Generalized Strategy for 3D Dose Verification of IMRT/VMAT Using EPID-measured Transit Images

Invisible sophistication. Visible simplicity. CS Welcome to the simplicity of compact panoramic imaging

Development of a Virtual Simulation Environment for Radiation Treatment Planning

An Introduction to TG-142 Imaging QA Using Standard Imaging Products. Mark Wiesmeyer, PhD, DABR Technical Product Manager Standard Imaging, Inc.

High Energy Digital Radiography & 3D-CT for Industrial Systems

SCINTILLATING FIBER DOSIMETER ARRAY

YOUNGS MODULUS BY UNIFORM & NON UNIFORM BENDING OF A BEAM

DIAGNOSTIC ACCREDITATION PROGRAM. Radiology and CT Quality Control Procedures Workbook

The evaluation of minimum detectable phantom thickness change using a scanning liquid filled ion chamber EPID dose response

A diagnostic tool for basic daily quality assurance of a tomotherapy Hi Art machine

Nuclear Associates

A new approach to measure dwell position inaccuracy in HDR ring applicators quantification and corrective QA

A Beam-Level Delivery Accuracy Study of the Robotic Image Guided Radiosurgery System Using a Scintillator/CCD Phantom

GafChromic EBT2 and EBT3 Films for Ball Cube II Phantom

Commissioning. Basic machine performance MLC Dose rate control Gantry speed control End-to-end tests

ISO INTERNATIONAL STANDARD

IQM Detector Characteristics: Signal reproducibility

APPLICATIONS FOR TELECENTRIC LIGHTING

Corundum C Axis Device for Sample Preparation Timothy Thomas, M.E., M.S.E.E. GIA Laboratory June 4, 2009

QC by the MPE in Belgium

Geometry. ELG HS.G.14: Visualize relationships between two-dimensional and three-dimensional objects.

Imaging system QA of a medical accelerator, Novalis Tx, for IGRT per TG 142: our 1 year experience

Effect of slit scan imaging techniques on image quality on radiotherapy electronic portal imaging

The Canadian Tire Paint Roller A Technical Description

Digital Radiography : Flat Panel

ISO INTERNATIONAL STANDARD

An Activity in Computed Tomography

Accurate two-dimensional IMRT verification using a back-projection EPID dosimetry method

Installation und Kommissionierung des Viewray MRIdian Linac Hamburg, 28. Mai 2018 Sebastian Klüter

Stability of the Helical TomoTherapy Hi Art II detector for treatment beam irradiations

Detector technology in simultaneous spectral imaging

7/24/2014. Image Quality for the Radiation Oncology Physicist: Review of the Fundamentals and Implementation. Disclosures. Outline

Quality Assurance Results for a Commercial Radiosurgery System: A Communication

Comparison of peripheral dose measurements using Ionization chamber and MOSFET detector

AUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF DIGITAL RADIOGRAPHY IMAGING SYSTEMS

Practice Problems (Geometrical Optics)

STUDENT REVIEW QUESTION SET K CR/DR CONTENT AREA

An EM Reconstruction with Improved Signal-to. to-noise Ratio for Coded Aperture Imaging

ArcCHECKTM. The Ultimate 4D QA Solution. Your Most Valuable QA and Dosimetry Tools. VMAT RapidArc TomoTherapy Pinnacle 3 SmartArc Conventional IMRT

8/3/2016. The EPID Strikes Back. Novel Applications for Current EPID Technology. Joerg Rottmann, PhD. Disclosures and acknowledgements

Nuclear Associates , &

Introduction. Use of EPIDs for Routine Linac QA 8/3/2017. Disclosure. Our research group receives funding from Varian Medical Systems

Nuclear Associates , , CT Head and Body Dose Phantom

TECHNICAL NOTE. The following information is provided as a service to our users and customers:

Key words: fluoroscopy, dose-area-product, kerma-area-product, calibration of KAP meters, patient exposure

JET 10" Sliding Dual Bevel Compound Miter Saw

Digital Panoramic X- Ray unit. Product Data

IMRT Delivery System QA. IMRT Dose Delivery. Acceptance testing. Why: specific tests for IMRT? Accuracy of leaf positioning (gaps) MLC Alignment

Enhanced Functionality of High-Speed Image Processing Engine SUREengine PRO. Sharpness (spatial resolution) Graininess (noise intensity)

Investigation of the line-pair pattern method for evaluating mammographic focal spot performance

Metrology Prof. Dr Kanakuppi Sadashivappa Bapuji Institute of Engineering and Technology Davangere. Lecture 24 Measurement of Screw Thread Element

BRANDON RICE UNIVERSITY OF FLORIDA

RADIATION SAFETY DIRECTORATE

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

CHAPTER 6 QUALITY ASSURANCE OF VARIAN ON-BOARD IMAGER

HIGH RESOLUTION COMPUTERIZED TOMOGRAPHY SYSTEM USING AN IMAGING PLATE

SUN NUCLEAR. EPIDose : An Overview of EPIDose and the EPIDose Process and Algorithm. corporation. Your Most Valuable QA and Dosimetry Tools

The Method of Verifying an Authenticity of Printing Production. Samples

NOT FOR DISTRIBUTION JINST_083P_0914 v1

SUMMARY. V-Lock SYSTEM BASIC ELEMENTS ACTUATORS. P V-Lock GENERAL INTRODUCTION 2. P V-Lock FIXING ELEMENTS 10 SUMMARY. P V-Lock ADAPTORS 17

Chiara Secco. PET Performance measurements of the new LSO-Based Whole Body PET/CT. Scanner biograph 16 HI-REZ using the NEMA NU Standard.

ArcCHECK. The Ultimate 4D QA Solution. Your Most Valuable QA and Dosimetry Tools

1 Version 2.0. Related Below-Grade and Above-Grade Standards for Purposes of Planning for Vertical Scaling:

NEXT GENERATION APOLLO LASER SYSTEMS FOR PATIENT ALIGNMENT IN RT

Transcription:

1 QUALITY CONTROL PHANTOMS FOR RADIOTHERAPY AND MEDICAL IMAGING QualiFormeD Phantoms A selection of test objects facilitating regulatory quality controls in radiation therapy and medical imaging Practical, comprehensive, accurate, clever and unique tools!

2

3 Table of contents Test objects for use with radiotherapy treatment machines... 4 Test Object OTP-EPID... 4 Test Object OTP-DISTO... 5 Test Objects OTP-ISO+ and OTP-CROSS... 6 Test Objects OTP-FIELD and OTP-FIELD28... 7 Test Objects OTP-ALIGN and OTP-BALL... 8 Test objects for use with external patient positioning lasers on CT-scanner installations dedicated to radiotherapy... 9 Test Object OTP-LAS... 9 Test Object OTP-PLAN... 10

4 Test objects for use with radiotherapy treatment machines Test Object OTP-EPID Quality Control of a high energy portal imager used in 2D-MV mode QUALIFORMED s OTP-EPID phantom has been designed to accurately measure in a single acquisition all the main parameters which characterize the performance of highenergy portal imagers operating with high energy X photons (4-25 MV) used in radiotherapy to determine patient position vis-à-vis radiation beam limits. Analysis of the images of the OTP-EPID test object is optimal (precise, automatic, quick) when used in conjunction with the QUALIMAGIQ software platform, complemented by the MOD- EPID analysis module ( see www.qualiformed.com). Manual analysis of the images remains of course possible. Specifications of the OTP-EPID test object Geometric distortions 49 tungsten balls distributed over a large surface to enable mapping of distortion. Spatial Resolution - ESF method OTP-EPID is the only test object available for applying ISO standard 12233:2000, referred to as the «Edge Spread Function», in order to accurately measure the imager s FTM. Spatial Resolution - Pairs of lines pattern Linearity of the imager response 16 horizontal and vertical patterns made up of regularly spaced line pairs, alternately radio-opaque and radio-transparent, allow you to evaluate spatial resolution visually. Contrast 22 targets of increasing thickness distributed equi-distant from the beam s center. The width of the discs prevents the measurements from being distorted by noise. Measured by 11 copper disks of increasing thickness set along a circular ring centered around the centre of the beam to be free of influence of any lack of homogeneity of captor response.

5 Uniformity of the response linearity of the imager 52 copper disks situated in 13 zones distributed evenly over the entire surface of the test object. Advantages of the OTP-EPID test object The essential measurements (spatial resolution, contrast and geometric distortions) may all be taken within a small radiation field ( : 12x12 cm² at 100 cm from the source), Measurement of the spatial resolution with a modern and accurate standardised method (ESF), The contrast is evaluated by large targets and constant diameters to avoid tainting the measurement with distortions by noise or/and the non-homogeneity of the signal, All of the targets contained in OTP-EPID are kept within a matrix, which ensures that their orientation follows the divergence of the radiation beam, thereby providing objects whose contours remain distinct in the images, The exterior surface of the test object is black and the alignment grooves are white, thereby facilitating alignment with the laser positioning system. The OTP-EPID phantom enables you to optimally fulfill all requirements of the French AFSSAPS decision dated 27/07/07 regulating Internal quality control of external radiation therapy installations: points 5.9.6 and 5.9.10 of the annex. Test Object OTP-DISTO Advanced testing of geometrical distortions stemming from a high energy (MV) or low energy (KV) «portal» imager used in 2D mode The OTP-DISTO phantom from QUALIFORMED enables you to obtain the complete 2D cartography of the geometrical distortions of the «portal» imager with just one click. The OTP-DISTO test object is made up of a network of 53 tungsten balls 2 mm in diameter, evenly distributed throughout a transparent acrylic plate 5 mm thick which measures 300 mm x 300 mm. This plate also bears a crosshair engraved in black. Analysis of the images of the OTP-DISTO test object is optimal (precise, automatic, quick) when used in conjunction with the QUALIMAGIQ software platform, complemented by the MOD-EPID+ analysis module for a high energy imager and MOD-18FG analysis module for a low energy imager ( see www.qualiformed.com). Most particularly QUALIMAGIQ yields a 2D cartography of all geometrical distortions stemming from the tested «portal» imager in less than 5 seconds with just 3 mouse clicks. The OTP-DISTO phantom enables you to optimally fulfill all requirements of the French AFSSAPS decision dated 27/07/07 regulating Internal quality control of external radiation therapy installations: point 5.9.10 of the annex.

6 Test Objects OTP-ISO+ and OTP-CROSS Control the size and position of the radiological isocentres, and the angles of the gantry, the collimator and the couch of a radiotherapy treatment device The OTP-ISO phantom, patented by QUALIFORMED, enables you to accurately perform the test proposed by Winston & Lutz [Int J Radiat Oncol Biol Phys (1988), 14(2):373-81]. The spatial position of the 3 rotation axes of the installation (gantry, collimator and table) in the treatment room is determined with optimal precision. The position is defined by a radioopaque ball aligned along the positioning lasers. Accuracy is ensured by the 3 perfectly orthogonal white equatorial grooves engraved on the surface of an acrylic sphere 100 mm in diameter, whose center corresponds to the center of the radio-opaque ball. The unit is suspended from an aluminum rod connecting it to a counterweight which includes a bull s eye spirit level, 3 adjustable screws for levelling the base and pre-alignment etchings. The acrylic sphere provides a zoom effect to better align the test object along the positioning lasers. The orthogonal white equatorial grooves set into the black background further facilitate alignment. The 2 to 2 coincidence, level and orthogonality of the laser planes may all be verified before carrying out the Winston & Lutz test. A set of 3 pairs of peripheral balls, used to determine the gantry s rotation angle, complete the test object. The aluminum holding rod enables the treatment table s rotation angle to be measured. The OTP-CROSS test object is affixed to the treatment machine s collimator outlet. It detects a fixed point in the images with regard to the radiation source, essential for carrying out the Winston-Lutz test. This fixed point is generally the centre of a small radiation field, however by using OTP-CROSS test results are not impacted by sagging of the jaws due to the gantry rotation angle. The collimator angle may also be measured from the orientation of the OTP-CROSS on the images. A high-precision version of the OTP-ISO test object is equipped with 3 micrometric screws. The sphere and then the positioning lasers can be positioned within 1/10 of a millimeter of the treatment machine s real isocenter by adjusting the screws. The test is carried out on high energy (MV) «portal» images in order to determine the treatment isocenter for the corresponding energy. By repeating this test on a low energy (kv) imager the alignment of the onboard imager onto the treatment isocenter can be verified. Analysis of the images of the OTP-ISO+ and OTP-CROSS test objects is optimal (precise, automatic, quick) when used in conjunction with the QUALIMAGIQ software platform, complemented by the MOD- ISO, MOD-ISO+, MOD-ISO-KV and MOD-ISO-KV+ analysis modules ( see www.qualiformed.com).

7 The OTP-ISO+ and OTP-CROSS test objects enable you to optimally fulfill all requirements of the French AFSSAPS decision dated 27/07/07 regulating Internal quality control of external radiation therapy installations: points 5.2.3, 5.2.8, 5.7.2 and 5.8 of the annex. Test Objects OTP-FIELD and OTP-FIELD28 Control of the congruence between the light fields and the irradiated fields for both symmetrical and asymmetrical rectangular fields produced by a radiotherapy treatment machine The OTP-FIELD test objects from QUALIFORMED enable you to control the positions of the light field limits of the 4 jaws of a simple collimator, using a high energy portal imager. Since it is easier and more objective to align the test object along the light beam rather than the contrary, OTP-FIELD is composed of a set of 20 rules of varying lengths, to accommodate all configurations of rectangular fields. Each of the 20 rules contains: 2 radio-opaque balls, a longitudinal engraving etched 8 mm from the pair of radio-opaque balls, a perpendicular engraving bisecting the rule. The rules are made from a plastic chosen for the high degree of rigidity it offers at such a low thickness, a necessary criterion to avoid impairing the detection of the radiated field limits. The OTP-FIELD test objects come equipped with: a customized aluminum storage case, double-sided, repositionable adhesive tape to temporarily secure the rules to the imager s cover when the gantry is set at another angle than 0. Analysis of the images of the OTP-FIELD test objects is optimal (precise, automatic and quick) when used in conjunction with the QUALIMAGIQ software platform complemented by the MOD-FIELD analysis module ( see www.qualiformed.com). Note that by using QUALIMAGIQ, in less than 10 seconds and with just 3 mouse clicks you can determine all tested light and irradiated field sizes without using X-ray film. Remark: the OTP-FIELD28 test object is a set consisting of only the 2 longest rulers of the 20 rulers making up the complete set of the OTP-FIELD test object.

8 The OTP-FIELD phantoms enable you to optimally fulfill all requirements of the French AFSSAPS decision dated 27/07/07 regulating Internal quality control of external radiation therapy installations: points 5.2.6 and 5.3.10 of the annex. Test Objects OTP-ALIGN and OTP-BALL Mechanical and geometrical tests of a radiotherapy treatment machine The OTP-ALIGN and OTP- BALL test objects designed by QUALIFORMED enable you to carry out several mechanical and geometrical analyses on radiotherapy treatment machines used in conjunction with high (MV) and low (KV) energy «portal» imagers. OTP-ALIGN is made of a transparent acrylic plate 5 mm thick which contains: a square tungsten frame, 150 mm x 150 mm 5 tungsten balls, each 2 mm in diameter a crosshair engraved in black OTP-BALL is made of a transparent acrylic plate 2 mm thick on which a crosshair is engraved in black. The base contains a tungsten ball 4 mm in diameter. The OTP-ALIGN test object is especially used together with «portal» imagers to determine the position of the mechanical rotation center of the treatment machine s crosshair, the mechanical vertical play, pixel size and the source imager distance of associated «portal» imagers... The OTP-BALL test object is especially used together with «portal» imagers to determine the position of the mechanical rotation center of the treatment machine s collimator, the mechanical play in relation to the gantry rotation of the associated «portal» imagers, sagging of the leaf banks of multi-leaf collimators Analysis of the images of the OTP-ALIGN and OTP-BALL test objects is optimal (precise, automatic, quick) when used in conjunction with the QUALIMAGIQ software platform, complemented by the MOD- EPID+, MOD-FIELD and MOD-MLC-stat analysis modules ( see www.qualiformed.com). The OTP-ALIGN and OTP-BALL test objects enable you to optimally fulfill all requirements of the French AFSSAPS decision dated 27/07/07 regulating Internal quality control of external radiation therapy installations : points 5.2.1, 5.2.2, 5.9.2, 5.9.3 and 5.9.4 of the annex.

9 Test objects for use with external patient positioning lasers on CTscanner installations dedicated to radiotherapy Test Object OTP-LAS Control the alignment of the laser positioning system s isocenter onto the CT-scanner isocenter The OTP-LAS phantom from QUALIFORMED enables you to verify the alignment of the origin of the positions of the laser positioning system with the anatomical origin of the CT-scanner, through a single acquisition of a dozen of CT-scanner slices. Advantages of the OTP-LAS phantom : OTP-LAS is robust and easy to align. This makes it particularly suitable for daily set-up of the routine control of the position of the isocenter of the laser in relation to the isocenter of the scanner. OTP-LAS is made entirely of transparent acrylic. The alignment engravings are white, which allows them to light up without dispersion when the lasers are aligned along them with the same intensity as for red or green lasers. Analysis of the images of the OTP-LAS test object is optimal (precise, automatic, quick) when used in conjunction with the QUALIMAGIQ software platform, complemented by the MOD-LAS or MOD-LAS+ analysis module ( see www.qualiformed.com). Most particularly QUALIMAGIQ supplies in less than 2 seconds with just 3 mouse clicks, the shifts between the laser positioning system and the CT-scanner: translations in the 3 directions of space. The OTP-LAS test object enables you to optimally fulfill point 8.6 of the annex of the French AFSSAPS decision dated 22/11/07 regulating Quality Control (QC) of the CT-scanners.

10 Test Object OTP-PLAN Comprehensive control of the laser positioning system s alignment to the CT-scanner Verification of longitudinal positioning accuracy (Head/Feet axis), horizontality of patient support, respect of the distances in images produced by a CT-scanner dedicated to radiation therapy applications The OTP-PLAN phantom from QUALIFORMED verifies all of the following in just 3 CT-scanner acquisitions: the accuracy of patient positioning along the Head/Feet axis, flatness and horizontality of the patient support on the transverse plane, respect of the distances on the transverse plane by the CT-scanner, alignment of the lasers positioning system along the 3 main CT-scanner axes and congruence between the isocenter of the CT-scanner and that of the laser positioning system. Advantages of the OTP-PLAN test object The adjustable leveling screws of the OTP-PLAN can be fully retracted so that the test object comes into perfect contact with the patient support during testing. The screws protrude to enable adjustment when testing positioning lasers. The OTP-PLAN test object is composed entirely of black acrylic plastic with alignment engravings etched in white. The white engravings thereby light up without dispersion when the lasers are aligned along them, equally so for both red and green lasers. The «inserts» are air-filled hollows, 0.5 mm in diameter, within the acrylic cubes. Detection of the position of the inserts in all spatial directions is as precise as possible, the limiting factor being the quality of the scanner images. In addition, the inserts provide strong contrast, registering a difference of 1100 Hounsfield Units. Analysis of the images of the OTP-PLAN test object is optimal (precise, automatic, quick) when used in conjunction with the QUALIMAGIQ software platform, complemented by the MOD-PLAN or the MOD-LAS+ analysis modules ( see www.qualiformed.com). QUALIMAGIQ s performance is particularly noteworthy - in less than 10 seconds with just 3 mouse clicks it determines the shifts between the positioning lasers and the scanner: translations in the 3 directions of space, and 3 rotations around these 3 directions. The OTP-PLAN test object enables you to optimally fulfill points 8.6 and 8.8 of the annex of the French AFSSAPS decision dated 22/11/07 regulating Quality Control (QC) of the CT-scanners.

11

12 Serving QualiFormeD Phone +33 (0)977009129 14, Rue de la Vieille Horloge Fax +33 (0)251248579 85000 La Roche Sur Yon, France Mobile +33 (0)661576911 www.qualiformed.com info@qualiformed.com Your local distributor: All given data and contents of this leaflet are only of informative and non binding character. This non contractual information can be modified or changed without any previous notice. No part of this brochure may be reproduced, copied or distributed in any way without prior written authorization by QualiFormeD Sarl. OTP-BRO-en-All-V1.2