Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

Similar documents
Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

Camera Overview. Olympus Digital Cameras for Materials Science Applications: For Clear and Precise Image Analysis. Digital Cameras for Microscopy

OLYMPUS Digital Cameras for Materials Science Applications: Get the Best out of Your Microscope

AxioCam MRc 5 A World of Digital Possibilities

The Flexibility of Choice

Versatility by Design

NOVA S12. Compact and versatile high performance camera system. 1-Megapixel CMOS Image Sensor: 1024 x 1024 pixels at 12,800fps

Systematic Workflow via Intuitive GUI. Easy operation accomplishes your goals faster than ever.

Turnkey Solution for Technical Cleanliness Inspection

Microscope Digital Camera DP80

Fein. High Sensitivity Microscope Camera with Advanced Software 3DCxM20-20 Megapixels

Bringing Answers to the Surface

CAMAG TLC VISUALIZER 2

Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup.

ZEISS Axiocam 503 color Your 3 Megapixel Microscope Camera for Fast Image Acquisition Fast, in True Color and Regular Field of View

Proudly serving laboratories worldwide since 1979 SPECIFICATIONS

AxioCam HR Success Through Performance

The Sussex Declaration

Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup.

CS-2000/2000A. Spectroradiometer NEW

Nikon SUPER COOLSCAN 5000 ED Major Features

Huvitz Digital Microscope HDS-5800

Quality Performance, Innovative Design

Automated Particle Counting Systems Fast, Accurate Measurement Data

In-Vivo IMAGING SYSTEMS. A complete line of high resolution optical & X-ray systems for pre-clinical imaging

Nikon COOLSCAN V ED Major Features

Real-color High Sensitivity Scientific Camera. For the first time with true color ISO9001

User Manual. cellsens 1.16 LIFE SCIENCE IMAGING SOFTWARE

pco.edge 4.2 LT 0.8 electrons 2048 x 2048 pixel 40 fps up to :1 up to 82 % pco. low noise high resolution high speed high dynamic range

Data Sheet SMX-160 Series USB2.0 Cameras

SUPRA Optix 3D Optical Profiler

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

Electron Microscopy RADIUS. Control & Imaging Software. RADIUS - The way forward in electron microscopy

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

DP2-BSW. User s Manual APPLICATION SOFTWARE

COLORMUNKI DISPLAY & i1display PRO

Real-color High Sensitivity Scientific Camera

Opto-digital Microscope. DSX Series. DSX Applications. High-resolution Upright scope. High-resolution Inverted scope. Free-angle Wide zoom scope

TEM Cameras. Digital Cameras for Electron Microscopy

MOTICAMPRO PROFESSIONAL CCD MICROSCOPY CAMERAS

Digital Microscope. User Manual

ZEISS Axiocam 512 color Your 12 Megapixel Microscope Camera for Imaging of Large Sample Areas Fast, in True Color, and High Resolution

INNOVATION+ New Product Showcase

e2v Launches New Onyx 1.3M for Premium Performance in Low Light Conditions

Achieving 100,000 : 1 contrast measurement

DIGITAL-MICROSCOPY CAMERA SOLUTIONS USB 3.0

CRISATEL High Resolution Multispectral System

Digital Cameras for Microscopy

Automated Imaging Technology to Simplify Your Workflow!

CHAPTER1: QUICK START...3 CAMERA INSTALLATION... 3 SOFTWARE AND DRIVER INSTALLATION... 3 START TCAPTURE...4 TCAPTURE PARAMETER SETTINGS... 5 CHAPTER2:

Technical Benefits of the

fsx.olympus-global.com

Information & Instructions

PRODUCT OVERVIEW FOR THE. Corona 350 II FLIR SYSTEMS POLYTECH AB

User Guide for TWAIN / DirectX interface for GRYPHAX USB 3.0 cameras


Thermography. White Paper: Understanding Infrared Camera Thermal Image Quality

Monochrome/Color Scan System

Zeta-300 3D OPTICAL PROFILER

Imaging Photometer and Colorimeter

edge 4.2 bi cooled scmos camera

IMAGING SYSTEM For Industrial Applications

Good things do come in small packages - high sensitivity and image quality

panda family ultra compact scmos cameras

Family of Stereo Microscopes Quality microscopes for industry and life sciences

Invisible sophistication. Visible simplicity. CS Welcome to the simplicity of compact panoramic imaging

The new Konica Minolta DiMAGE Scan Dual IV film scanner

Optika ISview. Image acquisition and processing software. Instruction Manual

Comparators. Contour Projector Technologies. Compare the Quality. Precision for People

TRUESENSE SPARSE COLOR FILTER PATTERN OVERVIEW SEPTEMBER 30, 2013 APPLICATION NOTE REVISION 1.0

Micro-Image Capture 8 Installation Instructions & User Guide

Spotlight 150 and 200 FT-IR Microscopy Systems

Spectral and Polarization Configuration Guide for MS Series 3-CCD Cameras

ISCapture User Guide. advanced CCD imaging. Opticstar

Multispectral. imaging device. ADVANCED LIGHT ANALYSIS by. Most accurate homogeneity MeasureMent of spectral radiance. UMasterMS1 & UMasterMS2

High-sensitivity. optical molecular imaging and high-resolution digital X-ray. In-Vivo Imaging Systems

Upgrade to Andor s high-resolution Luca EM R EMCCD; the new price/performance benchmark.

BioSpectrum Imaging System

User Manual. 3 MegaPixel CMOS Color Camera for Light Microscopy SC30

Improving the Collection Efficiency of Raman Scattering

ScientificCMOSReal-ColorCamera. Dhyana 400DC

The CCD-S3600-D(-UV) is a

Information. The next-generation flagship Nikon digital-slr camera with the ultimate in versatility and functionality

Collection Scanning Solutions. The ST ViewScan II System FILM FICHE FASTER TM

Compact high-speed cameras with high light sensitivity

Understanding Infrared Camera Thermal Image Quality

Technical Datasheet. Model AX50 / AX100 / AX200

A 4 Megapixel camera with 6.5μm pixels, Prime BSI captures highly. event goes undetected.

Olympus Digital Microscope Camera (DP70) checklist

Cast Iron Analysis. Nodular cast iron analysis

How does prism technology help to achieve superior color image quality?

High performance with no strings attached

185sec. 38sec. 20sec. Outstanding Image Quality with Amazing Scan Speeds

GXCapture 8.1 Instruction Manual

Retina 400 THE SIMPLE AND FLEXIBLE SOLUTION FOR HIGH DEFINITION RETINAL IMAGERY NON-MYDRIATIC RETINAL CAMERA C/D AUTO 60 H X 45 V LED. 2,2 mm.

FTA SI-640 High Speed Camera Installation and Use

Very short introduction to light microscopy and digital imaging

High Resolution BSI Scientific CMOS

Confocal NEXIV VMZ-K Series. CNC Video Measuring System CONFOCAL NEXIV. VMZ-K Series

Transcription:

Digital Cameras for Microscopy Camera Overview For Materials Science Microscopes Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis

Passionate about Imaging: Olympus Digital Cameras Versatility, performance, precise color reproduction, and integration into Olympus imaging platforms are characteristics that all Olympus microscope cameras share. Today, digital cameras are an indispensable tool in microscopy systems. The need to reliably acquire clear, crisp images is vital to every microscopist. No one understands this better than Olympus with its long and successful history in microscopy and lens design. Utilizing our long history integrating optical and digital technologies, Olympus developed a comprehensive range of digital cameras that are optimized for applications in materials science. Advanced Image Sensors The image sensor is the heart of any digital camera. This electronic component is responsible for digitizing images by acquiring, storing, and converting electron signals within an array. Sensors have a variety of resolutions measured by the number of pixels in their array. The number of pixels in the image sensor, the pixel size, and the mechanisms that convert light into electrons vary by camera type. Different combinations of these factors result in subtle changes in brightness and define the ultimate resolution of the digital image. Appropriate Sensor Types Olympus utilizes only highly efficient CCD and CMOS sensors. CCD sensors are the most common type used in Olympus microscope cameras. For research applications, the sensor of choice is the CCD or high-performance CMOS. The cost-effective CMOS sensor used in our SC50 camera is energy efficient and optimized for brightfield microscopy. Often used for general inspection purposes, these scientific-grade sensors are designed so that all pixels are devoted to capturing light and providing near dark uniformity for maximum flexibility in advanced material science applications. Pixel Shift Technology Capturing nine times the detail of stationary sensor cameras, pixel shift technology is ideal for optimizing the resolution on your microscope, an essential feature for low power microscopes. In addition, a new 3CMOS pixel shift mode in the DP74 camera enables three-color image resolution (RGB) within a single pixel to further improve resolution. Fast and Efficient Sensor signal processing is crucial to delivering reliable performance in a diverse range of industrial applications. Olympus cameras can detect up to 14 bits per channel, enabling fast and efficient image analysis. High frame rates facilitate real-time image viewing to focus and navigate to areas of interest directly on the PC screen. Color Fidelity Precise color reproduction and recording is important and a major challenge in image processing and documentation. Olympus cameras incorporate sophisticated algorithms that precisely distinguish color intensities, helping achieve maximum dynamic range and color fidelity. Sensitivity Cameras with sensitive sensors are normally used in difficult imaging conditions and for image analysis applications. The sensitivity of Olympus cameras can be increased by using various binning modes. Resolution The SC180 camera is an ideal choice for applications requiring display, measurement, and analysis. The camera s exceptional resolution allows it to document the fine structures and details, down to 1.25 μm 1.25 μm. With a pixel count of up to 18 million (18 megapixels), the SC180 exploits the full optical resolution of the objectives, making it possible to capture and document tiny details at very low magnifications. 4K Microscopy Olympus 4K Microscopy cameras combine advanced digital capabilities with increased resolution and field of view for fast, highly-detailed sample analysis. Live imaging and fast focusing contribute to faster inspections, and observations can be confirmed on-screen with only occasional use of the instrument s oculars. Software Control The advanced integration of all Olympus cameras in OLYMPUS Stream image analysis software provides intuitive operation from basic or advanced image acquisition to image processing, report generation, data export, and globally sharing of images and reports. 1

Improved image quality Left: without HDR; right: with HDR Improved resolution Left: standard camera; right: high-resolution camera Improved color reproduction Left: without color correction; right: with color correction Instant MIA: Easily move the stage for panoramic images EFI: Create all-in-focus images With instant multiple image alignment (MIA), you can now stitch images easily and quickly just by moving the XY knobs on the manual stage; no motorized stage is necessary. OLYMPUS Stream software uses pattern recognition to generate a panoramic image, giving users a wider field of view than a single frame. The extended focus imaging (EFI) function within OLYMPUS Stream software captures images of samples whose height extends beyond the depth of focus of the objective and stacks them together to create one image that is all in focus. EFI can be executed with either a manual or motorized Z-axis and creates a height map to easily visualize the sample's structure. It is also possible to construct an EFI image using offline using Stream Desktop software. EFI image of capacitor on PCB Instant MIA image of a coin 2

Digital Microscope Cameras for a Range of Applications Meeting the challenges of modern microscopy requires a diverse range of sensors. Olympus offers a sophisticated portfolio of digital color cameras that cover an array of material science applications. The sensor lineup ranges from cameras for documentation purposes to cooled, high-performance, high-sensitivity cameras for advanced applications. All cameras optimized to provide splendid digital imaging performance with Olympus microscopes and image analysis software systems. With standard mode Crisp images with LiveHDR mode (DP74) Preeminent performance Polarized image Universal Camera Models Universal cameras combine: high resolution, high sensitivity, and high-speed data transfer in any illumination mode. This makes them suitable for many applications including inspection, quality control, and materials science research, e.g. image analysis or digital brightfield documentation. These cameras are easy to use and feature real-time image viewing, splendid color fidelity, and special modes for image acquisition in difficult lighting conditions like the unique LiveHDR mode (DP74), an application that optimizes contrast and brightness in individual image regions. Etched aluminum acquired with the DP27 Suitable for digital documentation Standard Camera Models Olympus standard camera models offer balanced solutions for general documentation and image processing. Equipped with 5-megapixel and greater CCD, cameras capture images at a high resolution enabling large fields of view to be captured at low magnification and providing vivid clarity so that images remain clear even when digitally enlarged. Olympus cameras are also suitable for use in visual inspection and image processing thanks to splendid color fidelity, providing faithful color reproduction for a variety of samples. 3

Brightfield acquisition for standard applications Introductory Camera Models The specifications of sensors used in cost-effective camera models make them splendid for standard brightfield applications and more suitable for simple digital documentation purposes. With an splendid cost/ performance ratio, these are the most suitable entry-level cameras for digital image acquisition in microscopes. Infrared image acquired with the XM10-IR camera Gray Scale Camera Models Olympus offers gray scale cameras to provide a suitable solution for difficult imaging conditions such as fluorescence observation and near-ir imaging. The XM10-IR is a highly sensitive monochrome camera that features a cooled 1.4-megapixel CCD. The camera provides a spectral sensitivity from the visible to 1050 nm and is ideal for thin, through-silicon near-ir imaging. With a 14-bit analog-todigital converter (ADC), these cameras are used when gray scale values are of utmost importance. Stand-Alone Camera Models Stand-alone camera DP22/DP27 configuration example The DP22 and DP27 cameras can be used as advanced stand-alone models (no PC required). These cameras are ideal when precious bench space is limited. Both cameras can be controlled from a dedicated control box, providing smooth and intuitive operation via a touch-screen monitor or a mouse. 4

Advanced Digital Microscope Cameras for Demanding Applications Olympus offers a wide range of digital cameras for acquiring high-quality images that feature splendid resolution, contrast, and color reproduction. Some cameras, such as the XM10IR monochrome camera, are optimized for dedicated applications such as providing dependable gray scale value and infrared images. Other cameras, like the DP74, offer flexibility to deal with different applications, materials, sizes, or shapes. OLYMPUS Stream software provides intuitive control for whatever camera you choose. Live Inspection and Movie Recording Even though camera speed is important when dealing with inspection tasks and online recording, image quality is also important. The most suitable choice is a camera that offers a high frame rate at full resolution, such as the SC180 with 4K ultrahigh-definition (UHD). For live inspection without the need for UHD, the DP22 is a suitable camera for a stand-alone set up. DP22 UC90* SC50 SC180 Documentation Documentation is a well established task in industry and materials science. A camera mainly used for reporting should have a minimum of 3 megapixels and provide splendid color reproduction. When you need detail zooming in your reports, a camera with more than 5 megapixels is recommended for more appropriate results. Measurements Interactive measurements are standard tasks in materials science. For straightforward measurements 3-megapixel cameras are sufficient. DP27 SC50 SC180 DP27 UC90* UC50 Image Analysis Color reproduction is the main concern when you need to classify objects in color. Sensitivity is the other concern when dealing with image processing. Sensitivity can be increased by cooling and binning. Cooled models offer the advantage of images shown at full resolution while image resolution is reduced using binning. UC90* SC50 SC180 Difficult Imaging Conditions Imaging under low light conditions, like fluorescence, requires a very sensitive sensor. A monochrome sensor is most suitable choice for this application. For infrared image acquisition, a monochrome sensor can be equipped with a special filter to provide a spectral response that is ideal for thin, through-silicon, near-ir imaging. XM10 XM10IR 5 * UC90 is not available for Asian countries.

OLYMPUS Stream Software Adapts to Your Needs for an Efficient Workflow The OLYMPUS Stream image analysis software enables users to seamlessly acquire, process, and measure images, and create a flexible database. OLYMPUS Stream software provides the flexibility to fit your applications and meet your needs without changing your operation. Time is just as important as working conditions, and the OLYMPUS Stream system can be personalized to fit your process flow. An easy-to-use interface guides the user from image adjustment and capture to measuring, reporting, and archiving. As a result, you ll be able to achieve your tasks more efficiently, regardless of their complexity. Simple Snapshot Create Movies Define Resolution Focused live image Live Zoom and Focus The OLYMPUS Stream focus indicator enables the user to select a region of interest and bring it into optimum focus using the microscope s focus control. LiveHDR OLYMPUS Stream software s user interface for image acquisition (DP74) Full Integration All Olympus digital cameras integrate and work with OLYMPUS Stream software. The camera control tool window groups all necessary functions in an efficient overview: observe, adjust, and snap. Auto Calibration Similar to digital microscopes, automatic calibration is available when using OLYMPUS Stream software. Auto calibration helps eliminate human variability in the calibration process, leading to more reliable measurements. Auto calibration uses an algorithm that automatically calculates the correct calibration from an average of multiple measurement points. This minimizes variance introduced by different operators and maintains consistent accuracy, improving reliability for regular verification. 6

Microscope Digital Camera Specifications Specifications Universal model Standard model Category Outstanding performance Best addressable resolution in series Versatile Exceptional color fidelity Well-balanced performance Digital camera DP74 SC180 UC90 *5 DP27 SC50 Resolution (megapixels) 20.7 18.0 9.0 5.0 5.0 Chip size (inches) 1/1.2 in. Color CMOS 1/2.3 in. Color CMOS 1 in. Color CCD 2/3 in. Color CCD 1/2 in. Color CMOS Pixel size (µm) 5.86 5.86 1.25 x 1.25 3.69 3.69 3.45 3.45 2.2 2.2 Exposure times 39 μs 60 s 22 µs 1 s 100 μs 10 s 50 µs 8 s 31 μs 2.74 s ADC* 2 12-bit 12-bit 14-bit 12-bit 12-bit Live frame rates* 4 60 59 to 10.5 61 to 19.5 30 to 15 77 to 15 Dimensions (mm, Ø H) 116 (Ø) 87.7 (H) 58 (Ø) 32 (H) 86 (Ø) 47 (H) 77 (Ø) 42.5 (H) 58 (Ø) 33 (H) Weight (g, approx) 1100 188 530 160 182 3CMOS mode Available LiveHDR Available Camera adapter C-mount Control box DP2-SAL PC interface PCI Express 4 Rev.2.0 or later Compatible with low profiles USB 3.0 USB 3.0 USB 3.0 USB 3.0 Specifications Introductory model Stand-alone model* 1 B/W model Category Cost-effective models Space-saving Monochrome imaging For IR observation Digital camera LC30 DP22 XM10 XM10IR Resolution (megapixels) 3.1 2.8 1.4 1.4 Chip size (inches) 1/2 in. Color CMOS 1/1.8 in Color CCD 2/3 in. Monochrome CCD 2/3 in. Monochrome CCD Pixel size (µm) 3.2 3.2 3.69 3.69 6.45 6.45 6.45 6.45 Exposure times 57 µs 750 ms 50 µs 8 s 100 µs 160 s 100 µs 160 s ADC* 2 10-bit 12-bit 14-bit 14-bit Live frame rates 49 to 10 30 to 25 80 to 15 80 to 15 Dimensions (mm, Ø x H) * 3 77 (Ø) 42.5 (H) 86 (Ø) 48 (H) 86 (Ø) 48 (H) Weight (g, approx) 41 160 420 420 3CMOS mode LiveHDR Camera adapter C-mount Control box DP2-SAL PC interface USB 2.0 IUSB 3.0 IEEE 1394a IEEE 1394a *1 The DP27 may also be used a stand-alone model. *2 Analog-to-digital converter. The camera s actual bit depth depends on the software used. *3 The LC30 is not cylindrical unlike other cameras. Dimensions (H W D): 48.6 44 31 *4 Frame rate depends on the condition of your PC and/or software. *5 UC90 is not available for Asian countries. PC Requirements CPU RAM* 1 Hard disk Graphic* 2 Intel Core i5, Intel Core i7, Intel Xeon, (or equivalent) 4 GB or more (8 GB recommended) 2.4 GB or more free space VGA card of PCI Express X16 available for 32-bit color with 1280 x 1024 or more* The onboard graphic is also usable. OS* 3 Microsoft Windows 10 Pro (64-bit), Microsoft Windows 8.1 Pro (64-bit), Microsoft Windows 7 Ultimate/Professional SP1 (32-bit/64-bit) Language: English/Japanese *1 Required dual-channel for DP74. *2 Required configurations for LiveHDR in DP74. Graphic board applicable to CUDA made by NVIDIA (compute capability 2.1 or more) Graphic board driver applicable to CUDA 7.0 or more *3 Required 64-bit for LiveHDR, Pixel shift, and 3-CMOS functions in DP74. www.olympus-ims.com OLYMPUS CORPORATION is ISO14001 certified. OLYMPUS CORPORATION is ISO9001 certified. All company and product names are registered trademarks and/or trademarks of their respective owners. Images on the PC monitors are simulated. Specifications and appearances are subject to change without any notice or obligation on the part of the manufacturer. Shinjuku Monolith, 2-3-1 Nishi-Shinjuku, Shinjuku-ku, Tokyo 163-0914, Japan N8600594-092017