Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS

Similar documents
DRS390 High stability, flange mounting

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

ED701 General Industry Pressure Transmitter

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

PAD - Heavy Duty Differential Pressure Trasmitter

Smart Pressure Transmitter

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

Field IT 2600T Series Pressure Transmitters

2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter. Kent-Taylor

AT9000 Advanced Transmitter Differential Pressure Transmitters

General Specifications

General Specifications

Series Smart Pressure Transmitter

SITRANS P. Transmitters for level. Introduction 1/42. Application

Rosemount 2088 Absolute and Gage Pressure Transmitter A TRADITION OF EXCELLENCE IN PERFORMANCE FROM THE INDUSTRY LEADERS

GENERAL PURPOSE INDICATOR LOOP POWERED WITH VERY LARGE DIGITS DATASHEET F090 - GENERAL PURPOSE INDICATOR

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

AT9000 Advanced Transmitter Gauge Pressure Transmitters

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

General Specifications

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Strong monosilicon gauge pressure transmitter

Specifications. Range 5. ±0.075% of span. URL % of Span ± ±0.04% of span. Ranges 2-4. ±0.04% of span

SATRON VB Pressure Transmitter

PTG series Smart Pressure Transmitter

Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement

General Specifications

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Rosemount 3101, 3102, and 3105

SMART PRESSURE TRANSMITTER APC-2000ALW

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Submersible pressure sensor For oils and fuels Model LF-1

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

General Specifications

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

General Specifications

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

Compact Orifice Flow Meter

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Submersible pressure sensor For superior applications Model LF-1

Process display RIA 261

ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE)

Absolute Pressure Transmitters

Flow Measurement SITRANS F M

Coriolis Massflowmeter

Installation guide 873 SmartRadar Control Unit & Antenna Unit

General Specifications

AT9000 Advanced Transmitter Gauge Pressure Transmitters

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

SITRANS T measuring instruments for temperature

General Specifications

Differential Pressure Transmitters

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610e

OriMaster FPD500 Compact orifice flowmeter. Orifice-based flow metering made simple

Servo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability.

General Specifications

ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging.

General Specifications

Installation guide 877 FDI Field Display & Interface

General Specifications

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

Absolute Pressure Transmitters

General Specifications

General Specifications

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

General Specifications

General Specifications

Positioner with HART Communication Type 3780

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

FCX. Series AII & AIIe Electronic Transmitters. Barton

General Specifications

Electro-Magnetic Flowmeters COPA-XE

Submersible pressure sensor For water and wastewater Model LW-1

A New Generation of Pressure Transmitters

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Field IT 2600T Series Pressure Transmitters

General Specifications

TMU. Coriolis Mass Flow Meter. for liquids and gas

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

Pressure Transmitter SIL

VITO LT. Global Experience. Locally Applied. A dependable choice.

URV. Can be ordered separately see specification 34-ST Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ 85023

Installation guide 971 SmartRadar LTi

General Specifications

General Specifications

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

Condumax CLS15 and CLS15D

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

General Specifications

General Specifications

IP26 Series Current to Pneumatic Converter

DATASHEET F090 - GENERAL PURPOSE INDICATOR

FUNCTIONAL SPECIFICATIONS

Transcription:

DRS 300 1 Monocrystalline silicon smart differential pressure transmitter DRS300 High stability Detailed Information application the flow of gas, vapor and liquid measurement with device (volume or mass flow) Measurement of level, volume and mass Differential pressure monitoring Through a number of international certifications, widely used DRS 300 smart differential pressure transmitter uses monocrystalline silicon sensor chip and world's original design of monocrystalline silicon suspension that made of advanced MEMS technology, so it achieves the world's leading overpressure performance and also ensures excellent signal stability. Built-in manometry capsule and signal processing module that are imported from Germany achieve the perfect combination of static pressure and temperature compensation, which provides high measurement accuracy and stability under a wide range of static pressure and temperature. DRS 300 smart differential pressure (flow) transmitter can measure differential pressure accurately and convert it into DC4 ~ 20mA output signal. This transmitter can be operated through three-button locally or through universal communicator or configuration software remotely. Without affecting the output signal of DC4 ~ 20mA, it can display and configurate at the same time. Benefits High accuracy Differential pressure (flow) transmitter can measure high accurately in the 0.5 ~ 500kPa measuring range. The accuracy of standard calibration range: ±0.05% Positive and negative zero shift, without adjusting linearity Excellent overvoltage performance within a small range overpressure of 1kPa nominal range chip: 1.5MPa overpressure of 4kPa nominal range chip: 2.5MPa Excellent suitability of environment The intelligent static pressure and temperature compensation protect transmitter from the effects of temperature, static pressure and overpressure, so that the consolidated measurement error will be kept to the minimum. Flexible range of compression M1,M2 Range ratio: 20:1 M3 Range ratio: 40:1 M4,M5,M6 Range ratio: 100:1 Excellent operability & convenient use Five-digit LCD with backlight View of units (Pa, kpa, MPa, bar, mbar, %, psi, mmh 2 o) Quickly adjusted through built-in three buttons A variety of corrosion-resistant materials Comprehensive self-diagnosis function

2 DRS 300 Specifications Functional specifications Testing Fluid : Measuring range : M1 M2 M3 M4 M5 M6 range/ scope liquid, gas, vapor kpa inh2o mbar mmh2o range 0.5~10 2~40 5~100 50~1000 scope -10~10-40~40-100~100-1000~1000 range 1~20 4~80 10~200 100~2000 scope -20~20-80~80-200~200-2000~2000 range 1~40 4~160 10~400 100~4000 scope -40~40-160~160-400~400-4000~4000 range 1~100 4~400 10~1000 100~10000 scope -100~100-400~400-1000~1000-10000~10000 range 2~200 8~800 20~2000 200~20000 scope -200~200-800~800-2000~2000-20000~20000 range 5~500 20~2000 50~5000 500~50000 scope -500~500-2000~2000-5000~5000-50000~50000 static pressure : wetted material working pressure M1 01, 02, 03, 04, 05 2MPa M2 01, 02, 03, 04, 05 3.5MPa M3 01, 02, 03, 04, 05 3.5MPa M4 01, 02, 03, 04, 05 7MPa M5 01, 02, 03, 04, 05 7MPa M6 01, 02, 03, 04, 05 7MPa Note: code of & wetted material see the table Output signal : DC4~20mA+HART agreement Allowable load resistance : 0~600Ω(DC 24V) Note: when communicate with the handheld communicator, you need a standard (250Ω) load resistance Power supply : general service DC10.5~45V intrinsic safety explosion-proof DC10.5~26V Communication line condition : length of line: max 2km (0.75~1.25mm Control Instrument Cable exceeds 1 km :twisted pair cable) load resistance : 250~600Ω ( DC 24V,include cable resistance ) load capacity : under 0.55mF load inductance : under 3.3mH Spacing above power line : above 15cm ( please avoid parallel wiring ) Saturation current : upper limit 20.8mA lower limit 3.8mA Alarm current : upper limit 22.8mA lower limit 3.6mA ( Mode can be set ) Adjustment function : The zero & full span point can be adjusted in situ through three-button from the top of the housing or be adjusted remotely through configuration software. Environmental temperature : -40~+85 ( when filling fluorine oil : -10~+60 ) Storage temperature : -40~+90 Weatherability : DIN40040GPC EMC applicable standard : EN1326-1: 2006 Performance Specification Accuracy : reference precision TD1:1...TD15 :1 =±0.05% M1,M2,M3, M4,M5,M6 TD>15:1 =±(0.0015 TD+0.05)% *TD- range ratio square-root output precision: output precision 50% same as reference precision 50%~drop point reference precision 50 square root output (%) Effect of environment temperature : The total amount of effect /28 (50 F) effect M1,M2,M3 ±[0.08%range+0.015%upper limit of range] M4,M5,M6 ±[0.08%range+0.03%upper limit of range] Effect of static pressure : M1,M2,M3 M4,M5,M6 effect ±[0.05%range]/10MPa ±[0.05%range]/10MPa Effect of overpressure : ±0.05%upper limit of range/10mpa Stability : effect M1,M2,M3 ±0.05%upper limit of range/year M4,M5,M6 ±0.05%upper limit of range/year Effect of Power supply : ±0.005%/1V Effect of Mounting position : The changes of mounting position in the direction parallel to the diaphragm will not cause zero- drift effects. If the changes between the mounting position and the diaphragm is more than 90,which can be corrected through zeroing corrected within the range of 0.4KPa. Response time : 90ms Damp : The time constant can be adjusted from 0 to 99.9 seconds Filter constant : can be adjusted within 0 ~ 160 ua Self-stabilization coefficient : can be adjusted from 0 to 2% 600 Load resistance R(Ω ) 250 Communicated scope HART 10.5 16.4 24.7 45 Supply voltage DC (V ) The diagram of supply voltage and external load

DRS 300 3 Structure material wetted material: Refer to the code table code of detecting part material isolated diaphragm installed plywood 01 02 03 04 05 L Hastelloy C-276 Tantalum L Gold plating Hastelloy C-276 Hastelloy C Wetted sealing ring: fluororubber, chemigum Housing of transmitter: low copper aluminum die casting + polyurethane coating Cover of transmitter : aluminum die casting + polyurethane coating Ingress protection : IP67 Nameplate: Filling oil : silicone oil & fluorocarbon oil (Optional) Size : according to Outline Weight : about 2.9~3.1kg(Noumenon) Cable intake: G1/2,1/2-14NPT,M20 1.5 External terminal : M3 bolt Process connection port : Rc1/4 or 1/4-18NPT Installation: a U-bolt mounted on 50mm (2- inch) pipe, or on the wall (depend on the model specification) Electrical connection diagram Shell Power supply signal (4...20)mA Test signal Internal grounding wire External grounding wire Dimensional drawing of outline

4 DRS 300 Model and specification code table Type Specifications code Explanation DRS300 Monocrystalline silicon differential pressure transmitter Output signal H 4~20mA,HART digital communication protocol Range ( ) M1 M2 M3 M4 M5 M6 range:0.5~10kpa range:1~20kpa range:1~40kpa range:1~100kpa range:2~200kpa range:5~500kpa overpressure:2mpa overpressure:3.5mpa overpressure:3.5mpa overpressure:7mpa overpressure:7mpa overpressure:7mpa Wetted material Filling oil 01 02 03 04 05 99 01 02 99 isolation diaphragm : L Plywood : SUS304 isolation diaphragm : hastelloy C-276 Plywood : isolation diaphragm : Tantalum Plywood : isolation diaphragm : L gold planting Plywood : isolation diaphragm : hastelloy C -276 Plywood : hastelloy C silicone oil fluorocarbon oil Process connection Sealing ring Electrical connection Display header 01 02 99 01 02 99 01 99 D N female thread, 1/4-18NPT female thread, 1/2-14NPT fluororubber chemigum M20x1.5 with LCD nothing 2-inch pipe mounting bracket H V O flat bracket right angle bracket nothing Additional code of type selection Type selection specification *Reference type:drs300-h-m1-01-01-01-01-01-d-h

DRS 300 5 Additional specifications ( explosion- proof ) Projeckts Explanation Code Chinese standard NEPSI flame-proof and dust explosion-proof approval : Applicable standard : GB3836.1-2010 GB3836.2-2010 d Ⅱ CT6 ; DIP A21T T6 A T6 : maximum permissible surface temperature 85 Environmental termperature : -40~60 Electrical interface : 1/2NPT female thread, G1/2 female thread, M20 female thread ND1 NEPSI NEPSI intrinsic safety and dust explosion-proof approval : Applicable standard : GB3836.1-2010 GB3836.4-2010 ia Ⅱ CT6 ; DIP A20T T6 A T6 : maximum permissible surface temperature 85 Environmental termperature : -40~60 NX1 FM flame-proof approval Applicable standard : FM3600, FM3615, FM3810, ANSI/NEMA250 Flame-proof : Ⅰ rating, 1 district, B, C, D group Flame-proof burning : Ⅱ / Ⅲ rating, 1district, E, F, G group Hazardous locations : Indoor and outdoor ( NEMA4X ) T6 : environmental termperature : -40~60 Electrical interface : 1/2NPT female thread FD1 Certification of factory federation ( FM ) FM intrinsic safety approval Applicable standard : FM3600, FM3610, FM3611, FM3810, ANSI/NEMA250 Intrinsic safety : Ⅰ rating, 1 district, A, B, C, D group ; Ⅱ rating,1district, E, F, G group and Ⅲ rating, 1district hazardous locations Non combustibla : Ⅰ rating, 2 district, A, B, C, D group Ⅱ rating, 1 district, E, F, G group and Ⅲ rating, 1 district hazardous locations seal : NEMA 4X Termperature rating : T4 Environmental termperature : -40~60 Electrical interface : 1/2NPT female thread FX1 FM flame retardant approval Ⅰ rating, 2district, A, B, C, D group, Termperature rating T4, Type 4X Ⅱ rating, 2 district, F, G group, Termperature rating T4, Type 4X Ⅲ rating, 2 district, Termperature rating T4, Type 4X FX2 CENELEC (KEMA) flame-proof approval : Applicable standard : EN60079-0,EN60079-1 Identification : KEMA 02ATEX2148 Ⅱ 2G Ex d Ⅱ C T4, T5, T6 Environmental termperature : T5 : -40~80 ;T4andT6 : -40~75 The highest wetted temperature : T4:120 T5:100 T6:85 Electrical interface : 1/2NPT female thread,m20 female thread AD1 European Community (EC) (ATEX) CENELEC (KEMA) intrinsic safety approval : Applicable standard : EN50014,EN50020,EN50284 Identification : KEMA 02ATEX1030X Ⅱ 1G Eex ia Ⅱ C T4; Environmental termperature : -40~60 ; Electrical interface : 1/2NPT female thread, M20 female thread Including KF21,KS2 and N (non-sparking) approval : Applicable standard : EN 60079-0 : 2009, E,60079-15 : 2005 Ⅱ 3G Ex nl Ⅱ C T4 ; Environmental termperature : -30~60 ; Electrical interface: 1/2NPT female thread, PG13.5 female thread, M20 female thread AX1 AX2 CENELEC ATEX Type n approval : Applicable standard : EN 60079-0 : 2009, E,60079-15 : 2005 Ⅱ 3G Ex nl Ⅱ C T4 ; Environmental termperature : -30~60 AX3

6 DRS 300