A Single Phase Smart Grid Zero Steady State Error Connected in Dc/Ac Inverter with Heric Convertors

Similar documents
International Journal of Advance Engineering and Research Development

MPPT based New Transformer Less PV Inverter Topology with Low Leakage Current

MODELING AND ANALYSIS OF IMPEDANCE NETWORK VOLTAGE SOURCE CONVERTER FED TO INDUSTRIAL DRIVES

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

Grid Connected Photovoltaic Micro Inverter System using Repetitive Current Control and MPPT for Full and Half Bridge Converters

Analysis and Design of Solar Photo Voltaic Grid Connected Inverter

SVPWM Buck-Boost VSI

Digital Object Identifier (DOI): /IECON

A High-Efficiency MOSFET Transformerless Inverter for Nonisolated Microinverter Applications

Transformerless Grid-Connected Inverters for Photovoltaic Modules: A Review

Modular Grid Connected Photovoltaic System with New Multilevel Inverter

Control of Power Converters for Distributed Generation

Different Type of Inverter Topologies for PV Transformerless Standalone System

Control of grid connected inverter system for sinusoidal current injection with improved performance

High Efficiency Single Phase Transformer less PV Multilevel Inverter

Modeling of Single Stage Grid-Connected Buck-Boost Inverter for Domestic Applications Maruthi Banakar 1 Mrs. Ramya N 2

VIENNA RECTIFIER FED BLDC MOTOR

Modelling and Simulation of High Step up Dc-Dc Converter for Micro Grid Application

ISSN Vol.03,Issue.07, August-2015, Pages:

A Comparative Study between DPC and DPC-SVM Controllers Using dspace (DS1104)

Evaluation of Two-Stage Soft-Switched Flyback Micro-inverter for Photovoltaic Applications

IMPROVING EFFICIENCY OF ACTIVE POWER FILTER FOR RENEWABLE POWER GENERATION SYSTEMS BY USING PREDICTIVE CONTROL METHOD AND FUZZY LOGIC CONTROL METHOD

Closed Loop Control of Boost Converter for a Grid Connected Photovoltaic System

IMPROVED TRANSFORMERLESS INVERTER WITH COMMON-MODE LEAKAGE CURRENT ELIMINATION FOR A PHOTOVOLTAIC GRID-CONNECTED POWER SYSTEM

Hybrid PWM switching scheme for a three level neutral point clamped inverter

REDUCED SWITCHING LOSS AC/DC/AC CONVERTER WITH FEED FORWARD CONTROL

Using modified modulation and double frequency ripple suppression control reduce the capacitance in a single phase PV quasi-z-source inverter

Vienna Rectifier Fed BLDC Motor

Sepic Topology Based High Step-Up Step down Soft Switching Bidirectional DC-DC Converter for Energy Storage Applications

A Photovoltaic Three-Phase Topology to Reduce Common Mode Voltage

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

Modeling and Simulation of Matrix Converter Using Space Vector PWM Technique

Design and Implementation of Quasi-Z-Source Inverter for Off-grid Photovoltaic Systems

SVPWM Technique for Cuk Converter

Electromagnetic Compatibility and Better Harmonic Performance with Seven Level CHB Converter Based PV-Battery Hybrid System

Inverter topologies for photovoltaic modules with p-sim software

SVPWM Rectifier-Inverter Nine Switch Topology for Three Phase UPS Applications

Modified three phase Unified Power Quality Conditioner with capacitor midpoint topology

PV PANEL WITH CIDBI (COUPLED INDUCTANCE DOUBLE BOOST TOPOLOGY) DC-AC INVERTER

TRANSFORMER LESS H6-BRIDGE CASCADED STATCOM WITH STAR CONFIGURATION FOR REAL AND REACTIVE POWER COMPENSATION

GRID CONNECTED HYBRID SYSTEM WITH SEPIC CONVERTER AND INVERTER FOR POWER QUALITY COMPENSATION

International Journal of Engineering Science Invention Research & Development; Vol. II Issue VIII February e-issn:

Improved H6 Transformerless Inverter for PV Grid tied power system

Implementation of SRF based Multilevel Shunt Active Filter for Harmonic Control

SPACE VECTOR PULSE WIDTH MODULATION SCHEME FOR INTERFACING POWER TO THE GRID THROUGH RENEWABLE ENERGY SOURCES

EFFICIENT DUAL AXIS SOLAR TRACKER WITH H-BRIDGE INVERTER

New Direct Torque Control of DFIG under Balanced and Unbalanced Grid Voltage

A Novel Control Method for Input Output Harmonic Elimination of the PWM Boost Type Rectifier Under Unbalanced Operating Conditions

Harmonic Reduction in Induction Motor: Multilevel Inverter

An Interleaved Flyback Inverter for Residential Photovoltaic Applications

PhD Dissertation Defense Presentation

A Novel Power Factor Correction Rectifier for Enhancing Power Quality

Grid-Tied Interleaved Flyback Inverter for Photo Voltaic Application

ISSN Vol.05,Issue.07, July-2017, Pages:

ANALYSIS OF PWM STRATEGIES FOR Z-SOURCE CASCADED MULTILEVEL INVERTER FOR PHOTOVOLTAIC APPLICATIONS

An Interleaved High-Power Fly back Inverter for Photovoltaic Applications

Highly-Reliable Fly-back-based PV Micro-inverter Applying Power Decoupling Capability without Additional Components

Design of Single-Stage Transformer less Grid Connected Photovoltaic System

Power Quality improvement of a three phase four wire system using UPQC

Improvement of Power Quality Using Hybrid Active Power Filter in Three- Phase Three- Wire System Applied to Induction Drive

A Three Phase Seven Level Inverter for Grid Connected Photovoltaic System by Employing PID Controller

Usha Nandhini.M #1, Kaliappan.S *2, Dr. R. Rajeswari #3 #1 PG Scholar, Department of EEE, Kumaraguru College of Technology, Coimbatore, India

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING St. JOHNS COLLEGE OF ENGINEERING & TECHNOLOGY YERRAKOTA, YEMMIGANUR, KURNOOL, (A.P.

CHAPTER 3 VOLTAGE SOURCE INVERTER (VSI)

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

Delhi Technological University (formerly DCE) Delhi-42, India

Transformer less Grid Connected Inverter with Leakage Current Elimination

Design of Shunt Active Power Filter by using An Advanced Current Control Strategy

LOW ORDER HARMONICS IMPROVEMENT OF A SINGLE GRID CONNECTED INVERTER SYSTEM UNDER PR CONTROL TECHNIQUE

CHAPTER-III MODELING AND IMPLEMENTATION OF PMBLDC MOTOR DRIVE

PERFORMANCE ANALYSIS OF SOLAR POWER GENERATION SYSTEM WITH A SEVEN-LEVEL INVERTER SUDHEER KUMAR Y, PG STUDENT CHANDRA KIRAN S, ASSISTANT PROFESSOR

Shunt active filter algorithms for a three phase system fed to adjustable speed drive

MITIGATION OF VOLTAGE SAGS/SWELLS USING DYNAMIC VOLTAGE RESTORER (DVR)

PI-VPI Based Current Control Strategy to Improve the Performance of Shunt Active Power Filter

A Switched Boost Inverter Fed Three Phase Induction Motor Drive

Mitigation of Current Harmonics with Combined p-q and Id-IqControl Strategies for Fuzzy Controller Based 3Phase 4Wire Shunt Active Filter

A New Control Strategy for Three- Phase Inverter Applied To Induction Motor of Micro Grid

Realization of a Single-Phase Multilevel Inverter for Grid-Connected Photovoltaic System

Simulation of Solar Powered PMBLDC Motor Drive

Design and Implementation of Photovoltaic Inverter system using Multi-cell Interleaved Fly-back Topology

HIGH RELIABILITY AND EFFICIENCY OF GRID-CONNECTED PHOTOVOLTAIC SYSTEMS USING SINGLE-PHASETRANSFORMERLESS INVERTER. Abstract

A Novel Four Switch Three Phase Inverter Controlled by Different Modulation Techniques A Comparison

New Conceptual High Efficiency Sinewave PV Power Conditioner with Partially-Tracked Dual Mode Step-up DC-DC Converter

Bidirectional Ac/Dc Converter with Reduced Switching Losses using Feed Forward Control

IMPORTANCE OF VSC IN HVDC

Indirect Current Control of LCL Based Shunt Active Power Filter

A Contribution to Isolated and Grid-Connected Photovoltaic Systems under Shadow Conditions

B.Tech Academic Projects EEE (Simulation)

Sinusoidal Current Control based Shunt Active Power Filter for Current Harmonics Reduction

THE CONVENTIONAL voltage source inverter (VSI)

Feed-Forward System Control for Solid- State Transformer in DFIG

Harmonic Analysis Of Three Phase Diode Clamped Multilevel Inverters

A Novel H Bridge based Active inductor as DC link Reactor for ASD Systems

Load Compensation at a Reduced DC Link Voltage by Using DSTATCOM with Non-Stiff Source

Harmonic Analysis of 1.5 kw Photovoltaic System in the Utility Grid

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

Lecture 19 - Single-phase square-wave inverter

UNIFIED POWER QUALITY CONDITIONER IN DISTRIBUTION SYSTEM FOR ENHANCING POWER QUALITY

Modeling of PV Interconnected Distribution System using Simulink

Transcription:

A Single Phase Smart Grid Zero Steady State Error Connected in Dc/Ac Inverter with Heric Convertors S.Ayappan 1, K.Arulprabha 2, D.Priyanka 3, Assistant Professor 1, PG Scholar 2, 3,, Dept. of EEE, 1, 2, 3, Jayshriram Group of Institutions, Tirupur Abstract: Feed forward control is a reliable for rejecting fast and dynamic voltage disturbances in the phase grid. Mainly in this scheme implemented in phase voltages of the Wyes connected configuration. Under this unbalanced and distorted grid conditions, the online conversion of line - to - line values into the phase value is unworkable. In order to an exploit full advantages of feed forward controller is a most appropriate modulator is needed. In this article the feed forward of grid line-to-line voltages is used in phase voltages. The introduced feed forward method is implemented in Implicit Zero Sequence Discontinuous Pulse Width Modulation (IZDPWM) technique that is compatible for grid connected inverters. Regarding in the IZDPWM grid topologies distorted the harmonics of the grid voltages. Hence, a sinusoidal current is injected to the grid. Moreover, the measuring grid line-to-line voltages two sensors are required; hence an overall system costs is reduced and control system reliability is increased. The time-domain simulations in MATLAB/Simulink and experimental results from a Hardware based laboratory prototypes are in good agreements, which verify the effectiveness of the proposed generalized method. Keywords: unified integral controller, Synchronous; grid-connected inverters, unbalanced and distorted conditions. I. INTRODUCTION A single phase grid connected DC/AC inverter with reactive power controls for residential photovoltaic (PV) applications. In this work, the inverters are best control method of the inverter and the grid synchronization technique. Another challenge involved in the reductions size of the DC link capacitor in order to used a long life film capacitor in a low cost manner [1]. First a brief background on the single phase PV grid inverter connected is presented along with the motivation of this work. Then, a literature review on the PV inverter system configurations, controls, DC-link capacitor reduction techniques and the phase grid synchronization methods are presented. The objective method of this article is to develop an enhanced PI control, which integrates the PI control with a simple feedback term to eliminate the steady state errors with no need of additional complex algorithms such as the Synchronous Reference Frame (SRF) transformations. It has very simple structures and it can be easily implemented in practical applications. In addition the resonant frequencies of the controller are very easy to adjust. This is especially attractive for applications like frequency drop controlled micro grids, in which the frequency is changed according to the active power participation of each inverter [2-4]. That means that the output frequency reference of the inverter can change the fundamental and harmonics resonant frequencies of their respective controllers. Under the micro FIT program, they will be paid a much higher price for the electricity that the projects produce comparing to the standard price people pay for their electricity. Particularly, for PV rooftop generation, the contract price paid is 80.2 cents/kwh, whereas the blended rate of electricity in Ontario is 7.74 cents/kwh in the summer period [5]. The PV modules are connected in series, also referred to as PV strings, in order to provide sufficient output voltage. The PV strings are then connected in parallel through string diodes in order to achieve high power production. In this configuration, the centralized DC/AC inverter is subjected to handle, maximum power point tracking (MPPT), grid current control and voltage amplification if necessary. Although the configuration is simple, the drawbacks are substantial. One of the biggest is the poor energy harvesting capabilities of the centralized MPPT due to shading, panel mismatch and degradation factors [6]. ISSN: 2348 8379 www.internationaljournalssrg.org Page 38

can provide infinite gain at the reference signal s oscillating frequency [10-14]. Fig.2. Fig.1. Three - Phase SRF control scheme Single-phase SRF control scheme with virtual αβ frame a. Two Stage Inverters In order to improve the energy harvesting capabilities and design flexibility, dedicated DC/DC converters, which perform MPPT for each PV string, can be connected in the middle between the PV modules and the DC/AC inverter [7], Figure 1.2. The system shown in Figure 1.2(a) has its PCC at the AC terminal. This system type benefits from its modularity and the capability of plug-and-play installation by users that possess limited knowledge of electrical systems. The output from the DC/DC converter in this configuration can be either a low ripple DC voltage, or a modulated current that follows a rectified sine wave. In the latter case, the DC/DC converter handles MPPT and output current regulation while the DC/AC inverter switches at the grid frequency to unfold the rectified sine wave. Reference [8] is an example of the unfolding configuration. The SPWM control has a long history and is easy to implement. The traditional method of SPWM control uses a proportional-integral (PI) compensator in the feedback loop to regulate the output current. However, while PI compensators have excellent performances on regulating DC quantities, tracking a sinusoidal current reference would lead to steady state magnitude and phase errors [9]. Then, over the past two decade, researchers have explored use of proportional-resonant (PR) controller, while b. HERIC Topology The topology called Highly Efficient and Reliable Inverter Concept (HERIC), is commercialized by derives directly from the Full- Bridge converter, in which having a bypass leg has been added in the AC side by means of two back-toback IGBTs operating at grid frequency [13]. The HERIC circuit is shown in Fig. 2.1, where C in is the DC-link capacitor, Lfi and Lfg are the output filter inductors, respectively on the inverter-side and grid side, and Cf is the filter capacitor. The bypass branch has two important functions: decoupling the PV array from the grid (using a method called AC decoupling ), Avoiding the presence of highfrequency voltage Components across it and preventing the reactive power exchange between the filter inductors and Cin during the zero voltage state, thus increasing efficiency. The converter operates as it follows (see Table I): during the positive half-cycle S+ remains connected, whereas S1 and S4 commutate at switching frequency in order to generate both active and zero vectors. When an active vector is present (S1 and S4 are ON), current flows from the PV panels to the grid, while, when a zero vector occurs, S1 and S4 are switched OFF and the current flows through S+ and D-, this is the freewheeling situation. On the other hand, when the negative cycle is coming, S+ goes OFF and S- goes ON, whereas S3 and S2 commutate at switching frequency. It means that an active vector is present when S3 and S2 are ON, therefore the current flows from the PV panel towards the load, thus when S3 and S2 turn off, a zero voltage vector is present in the load, then current flows through S- and D+. With regard to the classical Full-Bridge converter, the HERIC inverter achieves a unipolar output voltage having the same frequency as the switching one. Moreover there are no high fluctuations at the DC terminals of the PV array; therefore the leakage current is very small [14]. II. CONSTRUCTION The control of grid-connected inverter plays an integral role in power processing in DG systems. In such applications the inverter need to inject high quality current into the utility grid. For this reason feed forward control is proposed to reduce the effect of the grid voltage distortion over the grid current. The mentioned objective is achieved by employing IZDPWM that creates the same harmonics existing in the grid line-to-line voltages. ISSN: 2348 8379 www.internationaljournalssrg.org Page 39

Fig.3. L-type grid connected inverter. In [10] the feed forward controller for the L- type grid-connected inverter has been developed, however, the implemented SVPWM-based predictive current controller is more complicated comparing with scalar PWM methods. The full-feed forward scheme that employs LCL-type inverter was introduced in [11]. Beside the LCL filter resonance hazard, full-feed forwarding is considered sophisticated; due to the existence of proportional, derivative, and second derivative parts. Moreover the L-type grid-connected inverter is much less susceptible to instability, and faults. The performance of the proposed feed forward controller is studied on the L-type grid-connected inverter shown in When 2 = 0, from equation 3 we can say that maximum emf is induced in coil S. But from2 equation 8, it is observed that the coil - to coil voltage ES3S1 is zero. This position of the rotor is defined as the electrical zero of the transmitter. III.WORKING The generated emf of the synchro transmitter is applied as input to the stator coils of control transformer. The rotor shaft is connected to the load whose position has to be maintained at the desired value. Depending on the current position of the rotor and the applied emf on the stator, an emf is induced on the rotor winding. This emf can be measured and used to drive a motor so that the position of the load is corrected. Fig.4. Proposed Inverter III. EXPERIMENTAL RESULTS Inverter Output Linearity Range In the precedence of implementing IZDPWM-based feed forward controller, the feasibility of IZDPWM need to be ensured as an open loop inverter controller. Thus IZDPWM was applied on the VSI shown in Fig. 1. The power circuit was simulated in MATLAB/Simulink power block set software, and its prototype was manufactured. Fig.5. Front Panel Diagram DC Supplies TDK-Lambada 630 V, 5 A IGBTs G4PH50UD 24 A, 1200 V Controller PIC 16F877A Lf 1.5 mh Cf 10 uf Resistive Load (Y) 2.4 KW, 380V, 61.25Ω Table.1 System Construction ISSN: 2348 8379 www.internationaljournalssrg.org Page 40

With the proposed feed forward scheme appreciable results were attained; and the injected grid current harmonics caused by the grid voltage distortion are significantly reduced. Since the line-to-line voltages were considered in the modulation, IZDPWM significantly contributed in reducing the number of sensors. Hence, high reliability control is achieved with decreased overall system cost. Fig. 6. Test results with solution B. (a) Simulation result. (b) Experimental results. Signal Quality IZDPWM0 was compared with DPWM0 in terms of THD of line-to-line voltage at switching frequency fs=9khz. As depicted in Fig. 7, the use of IZDPWM0 shows an appreciable output compared with DPWM0 at different modulation indices. The better result in terms of THD in IZDPWM0 is attributed to the employed modulating and carrier signals. The THD measured from the experimental setup is given in Fig. 6. At IZDPWM dropped the THD to 0.24% for. As shown in Fig. 7, THD= 0.94% obtained from simulated test is not consistent with the experimentally found value. Such dissimilarity is attributed to the power analyzer s resolution (bandwidth: 0.0 KHz to 10.6 KHz) that prevents accurate measurement of high frequency components. V. CONCLUSION The feed forward of line-to-line voltages grid connected three-phase three-wire two level VSIs is presented for the purpose of dealing with fast and dynamic grid voltage disturbances. The grid-connected inverter is modulated using IZDPWM0 that takes the line-to-line voltages as reference signals. In initial tests that deal with the inverter open loop operation; IZDPWM0 provided the desired output at balanced, unbalanced and distorted reference voltages. IZDPWM based feed forward controller is capable to control the inverter under weak grid condition without extracting grid voltage harmonics. Regardless grid topology, IZDPWM showed robustness in grid-connected operation mode. The presented control scheme was validated by simulation and experimental tests. FUTURE WORK The future work of this research can extend to design the front end DC/DC converter so that a two stage PV inverter system can be built for the analysis of the inverter s response when it is connected to a power source that is generated from the PV modules instead of a constant DC current source that is used in the lab. This research furthermore opens up the topic of actively exchanging reactive power with the utility grid at the distribution level. The control and communication methods between these type of local DRs and the central dispatch would be a useful area of study. VI. REFERENCES [1] K. Turitsyn, P. Sulc, S. Backhaus, and M. Chertkov, Local control of reactive power by distributed photovoltaic generators, in Smart Grid Communications (Smart- GridComm), 2010 First IEEE International Conference on, oct. 2015. [2] E. Paal and Z. Tatai, Grid connected inverters influence on power quality of smart grid, in Power Electronics and Motion Control Conference (EPE/PEMC), 2010 14th International, sept. 2015. [3] M. Ettehadi, H. Ghasemi, and S. Vaez-Zadeh, Reactive power ranking for dg units in distribution networks, in Environment and Electrical Engineering (EEEIC), 2014. [4] M. Kandil, M. El-Saadawi, A. Hassan, and K. Abo-Al-Ez, A proposed reactive power controller for dg grid connected systems, in Energy Conference and Exhibition (Energy Con), 2010 IEEE International, dec. 2013. [5] S. Dasgupta, S. Sahoo, and S. Panda, Single-phase inverter control techniques for interfacing renewable energy sources with micro grid, part i: Parallel-connected inverter topology with active and reactive power flow control along with grid current shaping, Power Electronics, IEEE Transactions on, vol. 26, no. 3, pp. 717 731, march 2011. [6] L. Liu, Y. Zhou, and H. Li, Coordinated active and reactive power management implementation based on dual-stage pll method for grid-connected pv system with battery, in Energy Conversion Congress and Exposition (ECCE), 2010 IEEE, sept. 2010, [7] S. Kjaer, J. Pedersen, and F. Blaabjerg, A review of singlephase grid-connected inverters for photovoltaic modules, Industry Applications, IEEE Transactions on, vol. 41, no. 5, pp. 1292 1306, sept.-oct. 2010. [8] G. Simeonov, Novel resonant boost converter for distributed mppt grid-connected photovoltaic systems, Master s thesis, University of Toronto, Toronto, 2010. ISSN: 2348 8379 www.internationaljournalssrg.org Page 41

[9] R. Erickson and A. Rogers, A micro inverter for building integrated Photo Voltaics in Applied Power Electronics Conference and Exposition, APEC 2009. Twenty-Fourth Annual IEEE, feb. 2009, pp. 911 917. [10] M. Kazmier kowski and L. Malesani, Current control techniques for three-phase voltage-source pwm converters: a survey, Industrial Electronics, IEEE Transactions on, vol. 45, no. 5, pp. 691 703, oct 2009. [11] D. M. Brod and D. W. Novotny, Current control of vsi-pwm inverters, Industry Applications, IEEE Transactions on, vol. IA-21, no. 3, pp. 562 570, may 2007. [12] T. Kato and K. Miyao, Modified hysteresis control with minor loops for single phase full-bridge inverters, in Industry Applications Society Annual Meeting, 1988., Conference Record of the 1988 IEEE, oct 2008, pp. 689 693 vol.1. [13] G. Vazquez, P. Rodriguez, R. Ordonez, T. Kerekes, and R. Teodorescu, Adaptive hysteresis band current control for transformer less single-phase pv inverters, in Industrial Electronics, 2009. IECON 09. 35th Annual Conference of IEEE, nov. 2009.. [14] S. V. Araujo, P. Zacharias, R. Mallwitz: Highly Efficient Single-Phase Transformerless Inverters for Grid- Connected Photovoltaic Systems, IEEE Transactions on Industrial Electronics, 57 (9), September 2010. ISSN: 2348 8379 www.internationaljournalssrg.org Page 42