ADI-100 Interrupter. Operator s Manual. 526 S. Seminole Bartlesville, OK /

Similar documents
Disclaimers. Important Notice

INSTALLATION & PROGRAMMING MANUAL PROGRAMMABLE TIMER (MODEL LP-2)

Quick Start Guide. Contents

Sutron SatLink2 Troubleshooting Instructions

Carlson Software Technical Bulletin SS900 Radio system with Geodimeter Robot

MAXI Remote Location Kit MRLK 900 Installation and Configuration Manual

SUNDIAL Light Dimmer. User's Manual

Disclaimers. Important Notice

EVDP610 IXDP610 Digital PWM Controller IC Evaluation Board

Dragon. manual version 1.7

UR200SI / UR200WE ENGLISH

Stalker Speed Sensor II Traffic Statistics Sensor Manual rev A

ET Water SmartWorks Panel Installation Guide

WARRANTY. Long Range Systems, LLC, 20 Canal St, Suite 4N, Franklin, NH 03235

MEASURE Evaluation. Global Positioning System Toolkit

Micromate User Manual

Wireless Transceiver - Bell & Tone Scheduling Troubleshooting Guide

CAST Application User Guide

JOINT STOCK COMPANY. MULTICHANNEL RECEIVER RI-4010M (version RM ) User guide

CD42-STS Operating Manual Diver/ROV Pipeline Pig Location & Tracking System

Featherweight GPS Tracker User s Manual June 16, 2017

Getting Started with TrangoLink

Vinyl Cutter Instruction Manual

GPS Position Sensor PS-2175

TRANSFORMER HD-HAMPTON HAMPTONBAY.COM

Nikon D7100 Camera Kit. -Checklist and Operations Manual-

INSTALLATION MANUAL FOR RADIO CONTROL SESAM 6099 TRANSMITTER

LBI-38808B. Maintenance Manual EDACS UTILITY PROGRAMMING

FAST TRACK READ ME FIRST! FAST TRACK E300 A Quick-Start Guide to Installing and Using Your COOLPIX 300. Contents. Nikon View... 25

Installation Manual REbus Beacon. Part of the Pika Energy Island M

Four Carrier Signal Generator Operation Manual

SIMREX Corporation Your Trusted Wireless Solution Provider

TX CONTROLLER Model EM-IP Quick Start Guide

DXXX Series Servo Programming...9 Introduction...9 Connections HSB-9XXX Series Servo Programming...19 Introduction...19 Connections...

OVEN INDUSTRIES, INC. Model 5C7-362

SA-027HQ 365-Day Annual Timer

Topcon Receiver Utility: GNSS Receiver Firmware Update Process. Oscar R. Cantu

MANUAL. PT Series 365 Day Annual Timer. Tel:

Manual for authorised electricians. Power meters. KD-401 Art.-Nr Version X00

Model # PCYFC-10kW-250A PCYFC-20kW-250A PowerCycle Battery Conditioner Operation Manual

The DesignaKnit Serial E6000 Link 1

Com-Trol ADV-6000 Trouble Shooting Guide Click on red text to go to that page in guide

MINIMUM SYSTEM REQUIREMENTS

WIRES-X Portable Digital Node Function. Instruction Manual

ProLink Radio. 900 MHz SDI-12 Data Radio Scienterra Limited. Version A-0x0C-1-AC 20 October 2009

ExpoM - ELF User Manual

Portable Appliance Testers. OmegaPAT MI 2140 BetaPAT MI 2141 User Manual Ver Code No

MATRIX 430. Entry level guidance Software version 1.03

Guardian and DL3282 Modem Interface Technical Service Application Note

Z-Max Surveying System

TR TR 641 top TR 642 top TR 644 top TR 641 top2 RC TR 642 top2 RC TR 644 top2 RC

Use this procedure when making a service run to sites where a Reftek RT-130 and a broadband sensor have been installed.

Figure 1 The Raith 150 TWO

Getting Started Guide

AZATOM SONANCE T1 Digital Radio. DAB+/DAB/FM Radio Alarm Clock. User Manual. This manual is available to download online at

Using the FGR-115MB in Mirrored Bit Applications

Antenna Pointing Guide

FLEXRISE2 VERSION. 2 LEG / 2 MOTOR ELECTRIC TABLE BASE (36 to 72 ) **PATENT PENDING**

Nikon Firmware Update for Coolpix 950 Version 1.3

AFN7500HD Decoder Troubleshooting Guide IMPORTANT DECODER UPDATE

Table 1. Placing the Sensor in the Sensor Cradle. Step Instruction Illustration

Montgomery County Emergency Services 800 MHz Rebanding Training. MTS 2000 Type II & III. Portable Radio

Message Greeter Installation and User Manual

PowerMonitor III. Digital Power and SWR meter for HF bands

Motorola APX. G1 SCBA Radio Pairing Guide Motorola APX. G1 SCBA Radio Pairing Guide for

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

RTK Base Station Configuration and Utilities. Table of Contents

QUICKSTART

Instruction Manual. Quick Setup

R PROFLAME Instruction Book Collection

GPS Dome Installation Manual

WIRES-X Portable Digital Node Function. Instruction Manual

SAT SCD/ARGOS INSTRUCTION MANUAL

Warehouse Instruction Guide

Installation Manual Mobile Integration System

Post-Installation Checkout All GRT EFIS Models

CHC i80 GNSS Receiver QuickTour with LandStar7. (PDA Network Mode)

The LEBOW 7554 Operator's Manual 7.2

Expandable Controller 3, 7, 11, 15 stations Installation and Programming Guide

VQ4100 TROUBLESHOOTING GUIDE. VQ4100 KING Quest HDTV System

Contents. Overview Introduction...3 Capabilities...3 Operating Instructions Installation...4 Settings... 5

Aqua-Gen 3BR INSTRUCTIONS

MIDLAND PROGRAMING G14

Initial Power-Up Tests

Installation and Operating Instructions. Power IT Power Factor Controller RVC

Houston Radar LLC. Installation and User Manual For. Doppler Radar DR-1500

Jet Central Sequencer Plus

SRM9000-Application Note

September CoroCAM 6D. Camera Operation Training. Copyright 2012

Table of Contents. Chapter 1: Software Installation...1. Chapter 2: Running the Software II. Daily Practical Operation...10

T25-35SA Subaudible Tone Decoder

PWM regulator for electrolysis cell Η 2

BeeLine TX User s Guide V1.1c 4/25/2005

Aqua-Gen 3PV INSTRUCTIONS

U S E R S M A N U A L

Energate Foundation Meter Data Collector Installation Guide

ProLogic Xtreme L22 - Electromechanical Redundant Safe Lock System - Instructions

BandMaster V Manual. Installation

Print Head Installation Guide

Operating Instructions Pocket Pictor For use with Pocket Pc s

Transcription:

ADI-100 Interrupter Operator s Manual 526 S. Seminole Bartlesville, OK 74003 918/336-1221 www.sescocp.com

ADI - 100 Interrupter FEATURES Clock Accuracy 100% during GPS lock Clock Drift 30 µsec per degree C during satellite obscurity Interruption Cycle.1 sec. To 3600 sec. (1 hr.) 24 Hour Timer Sets time of day to interrupt 28 Day Calendar Sets which days to interrupt Interruption Devices Solid State DC / AC Interruption Capacity 2000W 140V/100A Max Battery Backed RAM Maintains last schedule Serial Port Download schedule Resynchronize Never needed Display 4 line x 20 column LCD Keypad 16 Button Power Consumption Less than 1.8 Watts Operation Temperature 0 F to 150 F Power Supply 80V to 240V AC or 12V DC Case Pelican Enclosure Color Low Visibility Gray Page 2 of 11

INSTALLATION: CAUTION: Before installing this unit calculate the Wattage output of the rectifier by multiplying the output voltage with the current. If this value exceeds 2000W do not continue with the installation. 1. Turn rectifier off at the unit and at the pole disconnects. 2. For DC Interruption disconnect one of the rectifier output leads and connect the interrupter as shown in figure 1. The interrupter can be installed in either the positive (+) or negative (-) side of the output. For Secondary AC Interruption disconnect either the coarse or fine tap setting and connect the interrupter as shown in figure 2. For Primary AC Interruption break the hot leg feeding the rectifier and connect the interrupter as shown in figure 3. NOTE: Interruption on a 3 phase rectifier can only be accomplished by interrupting the DC output. DC INTERRUPTION SECONDARY AC INTERRUPTION PRIMARY AC INTERRUPTION FIGURE 1 FIGURE 2 FIGURE 3 Page 3 of 11

3. Connect the AC power supply leads of the interrupter to the AC input of the rectifier (figure 3) or connect the DC input to a battery (figure 4). Use either AC or DC to power the unit. NEVER CONNECT BOTH AC AND DC INPUTS TO THE UNIT AT THE SAME TIME. THIS COULD CAUSE BATTERY FAILURE. 4. Turn main disconnect and interrupter on and set desired schedule (see System Setup). When setup is complete start interruption by pressing [4] at the main menu screen. 5. Turn rectifier on, and confirm proper interruption is occurring. Page 4 of 11

ADI-100 SYSTEM SETUP When you first turn the interrupter on, the Current On (green) light will be on. The unit begins to gather information from GPS satellites. This process my take several minutes the first time it is used or when the unit has been moved more than 500 miles between uses. Normally it takes less than two minutes for this process. NEW: At power up, the interrupter will begin at the Main Menu. This allows the user to configure the unit while it obtains a GPS lock. The current date and time displayed throughout the setup screens are hidden until the unit acquires a GPS lock. 1 VIEW SCHEDULE 2 CHANGE SCHEDULE 3 LOAD SCHEDULE 4 ON/OFF 5 OFF/ON VIEW SCHEDULE Press [1] at the main menu to access this screen: 03/25/1999 16:10:30 START 07:00 STOP 19:00 It shows you the current date and time along with the current settings stored in the unit. See Schedule for explanations on the components within this option. Press [ESC] to return to the main menu. CHANGE SCHEDULE Press [2] at the main menu to reach this screen: 16:10:30 TIME ZONE: CST START: 07:00 STOP: 19:00 Press [ ] or [ ] to move to the data field you wish to change. Use [ ] and [ ] to increase or decrease the data field selected. The first option is the time zone, default is Central Standard Time (CST). All 24 worldwide time zones are available. Toggle to the zone that matches the time of your current location. Use this option to allow for daylight savings time. The START and STOP times are used to set the time interruption is to begin and end each day. Press [ENT] for the next screen. Page 5 of 11

SET INTERRUPTION CYCLE ON: 9. 0 OFF: 3. 0 START DATE: 03/25/99 CALENDER: CHANGE CHECK DATE: YES (Screen 1) (Screen 2) The ON and OFF data fields can be changed by toggling up and down or by entering a new time on the keypad. For a time of 120 sec. press [1] [2] [0] [ENT]. The interruption cycle can be set for whole seconds, tenths of a second, or a combination of both. To set or to add sub second interruption move to the field to the right of the ON time decimal and toggle up. The OFF time will change automatically. If date checking is required, toggle to the CHECK DATE field and press up or down. YES will be displayed with an arrow next to it. Toggle to the arrow and press up or down to reach Screen 2. Here the desired start date can be set. This date may be changed to start the unit at a future day such as installing the interrupters on Friday and the survey begins Monday. If check date is on the interrupter will automatically interrupt for the next 28 days starting on the start date. This setting can be changed in order to stop interruption on weekends or other days that surveying will not take place. To make these changes go to the CALENDER field and press [ ] or [ ]. The following screen will be displayed. 25 26 27 28 29 30 31 08 09 10 11 12 13 14 Y Y Y Y Y Y Y Y Y Y Y Y Y Y 01 02 03 04 05 06 07 15 16 17 18 19 20 21 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Scroll to the days you want the interrupter to be inactive and toggle up or down. The Y will change to an N. This screen allows you to see the first 14 days of the schedule. For the next 14 days scroll to the 14 th day a press [ ] again. Press [ESC] to return to the CHECK DATE screen. Press [ESC] again to return to the main menu. LOAD SCHEDULE When using a computer with the SESCO Download program, a schedule may be downloaded into the interrupter. This can be used to quickly setup multiple units with the same schedule. Connect the unit s communications port to an available 9 pin com. port on the computer. Press [3] at the main menu and execute download sequence on the computer. When complete press [ESC] to return to the main menu. Page 6 of 11

ON/OFF Press [4] at the main menu to start the interruption process in the SESCO format. The SCHEDULE light will come on and the interruption process will begin if the current date and time fall within the boundaries of the set schedule. For example if current date was 03/22/99 and the START DATE was set at 03/25/99, the schedule will not become active until 03/25/99. The CURRENT ON and CURRENT OFF lights will toggle to show that interruption is taking place. The display screen will blank in order to conserve power. Press a key at any time to stop the interruption process and return to the main menu. OFF/ON Press [5] at the main menu to start the interruption process in an alternate format. This format is compatible with other brands of interrupters. For best results, set the interruption cycle so that the total cycle (ON TIME + OFF TIME) is evenly divisible into 3600 i.e. (9 ON + 3 OFF = 12)(3600 / 12 = 50). Do not use cycles that result in a decimal number i.e. (7 ON + 4 OFF = 11)(3600 / 11 = 327.27). The unit will operate as described above. NOTE: This unit my not be compatible with all brands of interrupters. Be sure to verify that the elected schedule works properly with the other interrupters. Page 7 of 11

SCHEDULE DOWNLOAD PROGRAM REQUIREMENTS Microsoft Windows Available 9 pin RS-323 Communications port. DB9 Female to Female Cable (not supplied) INSTALLATION 1. Start windows 95/98. 2. Insert disk 1 into drive A: 3. Click on START and then Click RUN. 4. Type A:\setup.exe and click OK. 5. Follow the prompted instructions. USING SCHEDULE DOWNLOAD To run the program click START - Programs - SESCO - ADI-100 Schedule Download. Once the program is running connect an interrupter to the computer using an AT Null Modem Cable DB9F/F. From the interrupter s main menu press 3 to activate the serial communications. If the Schedule Download program doesn t recognize the connection, change the COM PORT setting to match the port being used by the computer. Once communication is established the UNIT NOT RESPONDING message will be replaced with the current setting stored in the interrupter. Page 8 of 11

COMPONENTS Hours of Operation: Sets the time of day (in 24 hour format) the interrupter will begin and end the interruption cycle. Interruption Cycle: Sets the time duration of the On and Off states. The total cycle time can range anywhere form 1 sec up to 3600 sec (1hr). Date Checking: Used to set a future start date in conjunction with a 28 day calendar. If Date Checking is off, the unit will interrupt every day until power is removed. To activate, click in the Date Checking box. Start Date can now be set to the day in which interruption is to begin. Click the Change button to modify the 28 day calendar. This can be used to stop the interruption process on days that surveying will no take place. To turn a day on or off simply click on the day you wish change. This example shows that interruption will take place every day except Saturdays and Sundays, starting with 9-9-1999. After the 28 days are up the unit will no longer interrupt. Time Zone: Used to set the interrupter s time to that of your location. Change the Time Zone setting so that the Current Time matches your locations time. The interrupter does not allow for day light savings time, therefore, you must change the time zone to compensate for this. Com Port: Sets the communications port the computer uses to communicate with the interrupter. Page 9 of 11

Interrupter Settings: This box displays the current setting stored with in the interrupter. After downloading a schedule use this window to verify that the new interrupter settings are correct. The GPS status window shows the signal strength being received from 8 of the Global Positioning Satellites. Download: Click this button to send the new settings to the interrupter. Simply move the COM cable to additional interrupters and click Download to set multiple units to the same settings. Default: Click this button to change the settings to predefined default values. Quit: Saves the setting and exits the Schedule Download. Note: For questions contact our phone number located on the cover page. Page 10 of 11

SESCO ADI-100 Operation Guidelines The lid must be latched closed to obtain water poof seal. GPS will still remain locked and unit will function properly. The magnetic mount GPS antenna can be pulled out approximately 17 Feet if necessary to achieve lock in covered areas. To release the additional wire, remove the 4 panel screws and clip the wire ties securing the antenna cable. Carefully pull the wire through the panel, make sure not to put excessive strain on wire or dislodge connection from the board. Be careful not to over tighten the interrupt cables. Doing so will cause damage to the case and make the plugs loose. Make sure to observe polarity when powering the unit from an external DC supply. Do not place the unit in an area that may be susceptible to standing water. Troubleshooting Problem Unit doesn t power up. Unit fails to pass current. Unit fails to interrupt current. Additional Issues Solution Check incoming power for polarity and adequate voltage. Check Fuse on top panel. Remove top panel and check 9V battery. Voltage must be 6V or more. Contact SESCO for instructions. Contact SESCO for instructions. Page 11 of 11