Active Rectifier in Microgrid

Similar documents
POWER ELECTRONICS. Converters, Applications, and Design. NED MOHAN Department of Electrical Engineering University of Minnesota Minneapolis, Minnesota

CHAPTER 3 H BRIDGE BASED DVR SYSTEM

SHUNT ACTIVE POWER FILTER

Design and Simulation of Fuzzy Logic controller for DSTATCOM In Power System

MODELLING & SIMULATION OF ACTIVE SHUNT FILTER FOR COMPENSATION OF SYSTEM HARMONICS

SIMULATION ANALYSIS OF DC/AC INVERTER UNDER NONLINEAR LOAD

International Journal of Advance Engineering and Research Development

CHAPTER 5 CONTROL SYSTEM DESIGN FOR UPFC

CHAPTER 5 MODIFIED SINUSOIDAL PULSE WIDTH MODULATION (SPWM) TECHNIQUE BASED CONTROLLER

Design of Three Phase PWM Voltage Source Inverter for Induction Heater

Hysteresis Controller and Delta Modulator- Two Viable Schemes for Current Controlled Voltage Source Inverter

CHAPTER 4 PI CONTROLLER BASED LCL RESONANT CONVERTER

ELEC387 Power electronics

Bidirectional Ac/Dc Converter with Reduced Switching Losses using Feed Forward Control

Losses in Power Electronic Converters

CHAPTER 6 BRIDGELESS PFC CUK CONVERTER FED PMBLDC MOTOR

Nicolò Antonante Kristian Bergaplass Mumba Collins

Application of Fuzzy Logic Controller in Shunt Active Power Filter

CHAPTER 2 A SERIES PARALLEL RESONANT CONVERTER WITH OPEN LOOP CONTROL

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

Power Factor Pre-regulator Using Constant Tolerance Band Control Scheme

Laboratory Investigation of Variable Speed Control of Synchronous Generator With a Boost Converter for Wind Turbine Applications

( ) ON s inductance of 10 mh. The motor draws an average current of 20A at a constant back emf of 80 V, under steady state.

Development of a Single-Phase PWM AC Controller

Modeling of Single Stage Grid-Connected Buck-Boost Inverter for Domestic Applications Maruthi Banakar 1 Mrs. Ramya N 2

DESIGN AND DEVELOPMENT OF ACTIVE POWER FILTER FOR HARMONIC MINIMIZATION USING SYNCHRONOUS REFERENCE FRAME (SRF)

Available online at ScienceDirect. Procedia Technology 21 (2015 ) SMART GRID Technologies, August 6-8, 2015

A VARIABLE SPEED PFC CONVERTER FOR BRUSHLESS SRM DRIVE

Direct AC/AC power converter for wind power application

A Predictive Control Strategy for Power Factor Correction

Single Phase Bidirectional PWM Converter for Microgrid System

Design and Simulation of Passive Filter

Three Phase Active Shunt Power Filter with Simple Control in PSIM Simulation

CHAPTER 4 MULTI-LEVEL INVERTER BASED DVR SYSTEM

Control Of Shunt Active Filter Based On Instantaneous Power Theory

Design of Hybrid Active Filter for Power Quality Improvement of Electrical Distribution System Using Fuzzy Logic Controller

Performance Comparison of Sensor and Sensorless Active Damping LCL Filter for Grid Connected of Wind Turbine

Indirect Current Control of LCL Based Shunt Active Power Filter

Active Elimination of Low-Frequency Harmonics of Traction Current-Source Active Rectifier

Inverter topologies for photovoltaic modules with p-sim software

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

A Series-Resonant Half-Bridge Inverter for Induction-Iron Appliances

A Novel H Bridge based Active inductor as DC link Reactor for ASD Systems

Analysis of Modulation and Voltage Balancing Strategies for Modular Multilevel Converters

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 01, 2016 ISSN (online):

A Comparative Study between DPC and DPC-SVM Controllers Using dspace (DS1104)

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

Current Control Technique for Three Phase Shunt Active Power Filter by Using Adaptive Hysteresis Current Controller

COMPARATIVE STUDY BETWEEN ACTIVE AND HYBRID POWER FILTERS FOR POWER QUALITY ENHANCEMENT

5DESIGN PARAMETERS OF SHUNT ACTIVE FILTER FOR HARMONICS CURRENT MITIGATION

Lecture 19 - Single-phase square-wave inverter

Chapter 2 Shunt Active Power Filter

UNIVERSITY OF CALGARY. Tahsina Hossain Loba A THESIS SUBMITTED TO THE FACULTY OF GRADUATE STUDIES IN PARTIAL FULFILMENT OF THE REQUIREMENTS FOR THE

Fundamentals of Power Electronics

A Novel Control Method to Minimize Distortion in AC Inverters. Dennis Gyma

Power Quality Improvement Using Hybrid Power Filter Based On Dual Instantaneous Reactive Power Theory With Hysteresis Current Controller

VSC Based HVDC Active Power Controller to Damp out Resonance Oscillation in Turbine Generator System

Power Electronics in PV Systems

UNIT-III STATOR SIDE CONTROLLED INDUCTION MOTOR DRIVE

A Review on Improvement of Power Quality using D-STATCOM

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

Z-SOURCE INVERTER BASED DVR FOR VOLTAGE SAG/SWELL MITIGATION

Bidirectional AC/DC Converter Using Simplified PWM with Feed-Forward Control

SIMULATION AND EVALUATION OF A PHASE SYNCHRONOUS INVERTER FOR MICRO-GRID SYSTEM

POWER FACTOR CORRECTION OF ELECTRONIC BALLAST FOR FLUORESCENT LAMPS BY BOOST TOPOLOGY

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

Pulse width modulated (PWM) inverters are mostly used power electronic circuits in

POWER- SWITCHING CONVERTERS Medium and High Power

Development of an Experimental Rig for Doubly-Fed Induction Generator based Wind Turbine

PF and THD Measurement for Power Electronic Converter

Fuzzy Logic Control of APF for Harmonic Voltage Suppression in Distribution System

A Half Bridge Inverter with Ultra-Fast IGBT Module Modeling and Experimentation

CHAPTER 4 4-PHASE INTERLEAVED BOOST CONVERTER FOR RIPPLE REDUCTION IN THE HPS

IJESRT. (I2OR), Publication Impact Factor: (ISRA), Impact Factor: Student, SV University, Tirupati, India.

CHAPTER 4 FULL WAVE RECTIFIER. AC DC Conversion

Comparative Study of Pulse Width Modulated and Phase Controlled Rectifiers

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

MODELING AND ANALYSIS OF IMPEDANCE NETWORK VOLTAGE SOURCE CONVERTER FED TO INDUSTRIAL DRIVES

Improving Passive Filter Compensation Performance With Active Techniques

Power Quality Improvement in Hybrid Power Generation for Distribution System Using PWM Technique

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

CHAPTER IV DESIGN AND ANALYSIS OF VARIOUS PWM TECHNIQUES FOR BUCK BOOST CONVERTER

Speed control of power factor corrected converter fed BLDC motor

EMBEDDED CONTROLLED ZVS DC-DC CONVERTER FOR ELECTROLYZER APPLICATION

Shunt Active Power Filter based on SRF theory and Hysteresis Band Current Controller under different Load conditions

Single Phase Induction Motor Drive using Modified SEPIC Converter and Three Phase Inverter

Analysis and Design of Solar Photo Voltaic Grid Connected Inverter

Australian Journal of Basic and Applied Sciences. Design of a Half Bridge AC AC Series Resonant Converter for Domestic Application

PERFORMANCE EVALUATION OF THREE PHASE SCALAR CONTROLLED PWM RECTIFIER USING DIFFERENT CARRIER AND MODULATING SIGNAL

Simulation of Improved Dynamic Response in Active Power Factor Correction Converters

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

CHAPTER 2 SIMULATION AND EXPERIMENTAL INVESTIGATION OF THE LCL AND LCC RESONANT INVERTERS AND LCL RESONANT CONVERTER

e-issn: p-issn:

Implementation and Design of Advanced DC/AC Inverter for Renewable Energy

ELG3336: Power Electronics Systems Objective To Realize and Design Various Power Supplies and Motor Drives!

Development of DC-AC Link Converter for Wind Generator

HARMONIC contamination, due to the increment of nonlinear

Harmonic Analysis of Sine PWM and hysteresis current controller

Generalized Multilevel Current-Source PWM Inverter with No-Isolated Switching Devices

Transcription:

03.09.2012 Active Rectifier in Microgrid - Developing a simulation model in SimPower - Dimensioning the filter - Current controller comparison - Calculating average losses in the diodes and transistors Kristiansen Baricuatro Sergey Klyapovskiy Umair Ashraf Emmanuel Omede MSc in Electric Power Engineering TET4190 Power Electronics for Renewable Energy Supervisors: Tore Undeland (NTNU) Roy Nilsen (Wärtsilä) Mini-project 15a Project Group N Faculty of IME

PREFACE This report was written by four students from NTNU, for the mini-project for the course TET4190 Power Electronics for Renewable Energy. The report describes the project s background, its objectives, the methods used to achieve these objectives and the results of these efforts. We chose this project because it tackles many interesting parts within the power electronic field. In addition to learning more about converters and control methods, the task gave us an opportunity to learn how to use a Simulink toolbox, SimPower. The project is carried out in the period September to October 2012. We wish to thank Wärtsilä and Roy Nilsen for giving us the opportunity to work with them, and be granted the guidance that we needed. At NTNU, we want to thank our supervisor, Professor Tore Undeland for his supervision and guidance during the project. Trondheim, 03.09.2012

Table of Contents 1 ABSTRACT... 2 2 INTRODUCTION... 3 2.1 Structure and content of the report... 3 2.2 Problem formulation... 3 2.3 Why wartsila wants to work with the problem... 3 2.4 Objectives of the project... 3 3 THEORY... 4 3.1 Microgrid... 4 3.2 Inverter... 4 3.3 Current controller analysis... 5 3.3.1 PI PWM Current Controller.... 5 3.3.2 Hysteresis Current Controller... 6 3.4 LCL Filter... 6 4 CALCULATIONS... 7 4.1 Dimensioning the filter... 7 4.2 Calculating average power loss in the diodes and the transistors... 8 4.2.1 Switching losses... 8 4.2.2 Conduction losses... 8 5 SIMULATION... 10 5.1 The model... 10 5.2 Results... 13 5.2.1 PI PWM Current Controller with f s = 20 khz... 13 5.2.2 Hysteresis Current Controller with f s = 20 khz... 15 5.2.3 Comparisons... 17 6 CONCLUSION... 19 7 REFERENCES... 20 8 LISTS OF FIGURES, TABLES AND ABBREVIATIONS... 20 9 APPENDIX... 21 Mini-project 15a 1

1 ABSTRACT Renewable Energy sources are usually to be looked upon as Distributed Energy Resources (DER). They have to be integrated into a local energy network; the Microgrid. An inverter (DC/AC-converter) is used to connect this system to the utility grid. Two simulation models of such an inverter have been made: One with a PI-current controller and the other with a hysteresis current controller. Both current control techniques had been studied and analyzed through theory and simulation. Calculations had been made to dimension a LCL filter for the system and to find the average losses in the diode and transistors. Mini-project 15a 2

2 INTRODUCTION This chapter will present the objectives and requirements of the project. 2.1 STRUCTURE AND CONTENT OF THE REPORT The report is based on theoretical presentations and simulations on two different kinds of current controllers. Introductory chapters present the task. Chapter 3 gives a theoretical presentation of inverters and current controllers. Chapter 4 deals with calculations. Chapter 5 deals with the main part of the project which is the simulations. The final chapter is devoted to conclusion. Attached zip-file or CD contains data sheet, simulation results, SimPower models and matlab files. 2.2 PROBLEM FORMULATION The desire for increasing their efficiency and reducing the harmful emissions lead to the widely spreading and applying of small-scale generators, which are commonly called distributed generation (DG) units. The attempt to realize the DG potential has led to the appearance of Microgrid concept. The main characteristics of Microgrid concept are: It is a local scale power system with DG units, which produces electrical or thermal energy to the local system demand. It can provide power supplies to the customers with multiple load locations. It creates the possibility of seamless crossing between grid-connected mode and autonomous operation (island mode). It increases the power quality and system reliability. In addition, it provides significant control capabilities over the network operation. Different types of DG units could have different output nature, than the network which they are supposed to work with. Since the existing Microgrids are operating as AC systems, we need to use power electronic interfaces in order to connect DG units. 2.3 WHY WARTSILA WANTS TO WORK WITH THE PROBLEM Wärtsilä is a global leader in complete lifecycle power solutions for the marine and energy markets. Since Wärtsilä is integrating DG units on ships and their power plants are based on renewable energy, they need to use power electronics to connect and control DG units. 2.4 OBJECTIVES OF THE PROJECT During the Miniproject, a simulation model of Inverter for 230 V ac and 20 kw should be created using SimPower. To keep voltage ripples on acceptable level, the parameters of LCL-filter should be chosen. The project group will also compare the behavior of a PWM-modulator with a PIcurrent controller with the behavior of a hysteresis current-controller and calculate the average losses in the diode and transistors. Mini-project 15a 3

3 THEORY 3.1 MICROGRID A microgrid is power supply network which is designed to provide power to a certain area. It also can provide the power to centralized grid. Generators and loads are connected at low voltage in micro grid. Sources of power generation related to microgrid are usually renewable energy. The power we get from the renewable energy sources is mostly DC power, so to operate our load which is AC driven we need inverters. Inverters are thus essential part to get energy from renewable energy sources. 3.2 INVERTER Figure 1: Three-phase inverter Inverters convert DC power into AC power. Conversion of this energy is done with a three-phase full bridge inverter and for every single switch we need anti parallel diode. The main idea behind an inverter is to get a pure sinusoidal voltage and current for our AC driven load. To obtain this pure sine wave, we use different components and control methods in the inverter. The component characteristics determine the conduction losses, maximum switching frequency, power handling capability and temperature dependent variables. The control methods will determine the switching frequency. Mini-project 15a 4

3.3 CURRENT CONTROLLER ANALYSIS For high performing three phase AC drives, the current controlling technique is of great importance as the characteristics of the inverter such as the switching frequency, level of harmonic distortion and the measure of dynamics in the output response. Two techniques are discussed, PI PWM current controller (linear) and the Hysteresis PWM current controller (non-linear). Figure 2: PWM Current Controller 3.3.1 PI PWM CURRENT CONTROLLER. This is a linear current controller known as the proportional-integral regulator. In this technique, the phase current is compared to a reference current value and output error compensated through the PI error compensator whose output is further used to modulate the IGBT (inverter switch) or the PWM. The integral part of the PI compensator minimizes errors at low frequency, while proportional gain and zero placement are related to the amount of ripple [1]. The ripple in the output current is amplified by the gain of the compensator, thus influencing the switching frequency of the switches. This technique requires minimal harmonic frequency below the carrier frequency. The disadvantage is in the tracking error of the output current amplitude and phase [1]. Figure 3: PI PWM current controllers Mini-project 15a 5

3.3.2 HYSTERESIS CURRENT CONTROLLER This is one of the mostly used current controller technique because it is very easy to implement as compared to other types. Knowledge of load parameters is not required and its current loop response is faster than others [2]. In the hysteresis technique, actual phase current in a three phase systems is compared with a reference current for the same phase and the error passed through a hysteresis band to generated input pulses to regulate the IGBT for minimal current errors. This is done for three phase currents of the system but with one disadvantage of phase quantity interaction in a three phase system. Each three phase output currents to the load are compared with the respective reference phase currents by three hysteresis comparators for each phase and the output used to activate the inverter switches. But additional circuitry is required since the switching frequency/the ripple current varies at every point of the fundamental frequency. 3.4 LCL FILTER Figure 4: Hysteresis current controllers Figure 5: Three-phase inverter with LCL filter The DC/AC inverter discussed in chapter 3.1 consists of the DC link, three-phase inverter and the filter. To minimize the current harmonics, we need a bulky inductance in the filter to achieve good performance. The LCL filter, consisting of two inductors and one capacitor, is a popular choice because of its better attenuation for switching frequency harmonics and its low cost. However, an LCL filter has its own drawback. Because of the peak at the resonance frequency, the filter will increase instability of the system. To counteract this, we use a damping resistor in series with the capacitors. Mini-project 15a 6

4 CALCULATIONS 4.1 DIMENSIONING THE FILTER When dimensioning the LCL filter, the following should be kept in mind. The total inductance should be large to have lower harmonic distortion, but it will also slow down the system response. It is also important to keep in mind that inductance size is proportional to the cost. To have a high power factor, the capacitor should not be too large since it absorbs reactive power. The damping resistor should not be too large since it would produce huge power loss. First a suitable overall inductance value L s is chosen: [3] Where E m is the peak voltage of the grid, I m is the peak current of the grid, f sw is the switching frequency, and i ripple is the current ripple. Since we want a low value of L s for cost reasons, we will use the minimum boundary. The capacitance C f is then chosen: [3] Where q is the percent reactive power we want absorbed, f n is the grid frequency, E n is the rms value of the phase voltage, and P n is the rated power produced by the inverter. The value of the two inductances L 1 and L 2 is dictated by a ratio r: The resonance frequency f res should be check if it is suitable: ( ) Lastly, the damping resistor is calculated: [3] Mini-project 15a 7

4.2 CALCULATING AVERAGE POWER LOSS IN THE DIODES AND THE TRANSISTORS The IGBT and Diode power losses (P i), can be divided into two groups: the conduction losses (P cond) and the switching losses (P sw). 4.2.1 SWITCHING LOSSES The switching losses in the diode and the IGBT are the product of switching energies and the switching frequency: [4] ( ) ( ) The turn-on energy losses in the IGBT (E ont) can be calculated as the sum of the switch-on energy without taking the reverse recovery process into account (E onti) and the switch-on energy caused the reverserecovery of the free-wheeling (E ontrr). The turn-on energy in the diode consists mostly of the reverserecovery energy (E ondrr). [4] ( ) ( ) ( ) ( ) where U Drr is the voltage across the diode during reverse recovery and Q rr is the diode recovery charge. The turn-off energy losses in the IGBT can be calculated in the similar manner. The switch-off losses in the diode are normally neglected. [4] ( ) ( ) To simplify calculations, typical switching energies given on the data-sheet of the supplier are used. 4.2.2 CONDUCTION LOSSES The instantaneous value of the IGBT and the diode conduction losses are given: [4] ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) The average conduction losses across the switching period (T sw=1/f sw) are: ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) The dynamic resistance values for IGBT and diode (r c and r d) can be read from the data-sheet diagram of the supplier (as shown at the figure below). Since both values are dependent on the junction temperature, we took into account the worst case scenario which is at T j =150 C. Mini-project 15a 8

Figure 6: Calculating dynamic resistance values Mini-project 15a 9

5 SIMULATION 5.1 THE MODEL A simulation model of the specified system was created using SimPower. Figure 7: Simulation model It consists of a three phase full bridge inverter for a 230 Vac and 20 kw load. The inverter has a constant DC voltage source of 680V. An Infineon IGBT with anti-parallel diode IKW40T120 was used. Lastly, a LCLfilter is connected on the AC side of the inverter to minimize ripples. As Figure 8: Current Controllers Two different controllers are used, a hysteresis current-controller and a PWM-modulator with a PIcurrent controller. Mini-project 15a 10

Figure 9: Switching frequency checker To determine the average switching frequency of an inverter with a hysteresis current controller, a subsystem was created to measure the switching frequency. This is done by counting the number of rises on a gate signal which basically tells us the number of switches made, and holding the count once the clock reaches the fundamental period. Dividing the number of switches by the fundamental period then gives us the switching frequency. Figure 10: Power loss calculations A subsystem dedicated for power loss calculations was also created, using the equations discussed at chapter 4.2. Mini-project 15a 11

Figure 11: Conduction loss calculations Figure 12: Switching loss calculations The LCL filter values are calculated automatically using the equations discussed at chapter 4.1 through a matlab script each start of a new simulation to accommodate changes in input data. Mini-project 15a 12

5.2 RESULTS 5.2.1 PI PWM CURRENT CONTROLLER WITH F S = 20 KHZ Using 20 khz switching frequency, and assuming 20% current ripple gave us the following values for the LCL filter: L1 14,58 mh Cf 22,17 mf L2 10,2 mh Table 1: LCL Filter for fs = 20 khz Starting with the PI PWM Current Controller, the scope readings below show us how the PWM controller works. When the PI output which is our control voltage is more than the triangular wave voltage, the upper thyristor T A+ is conducting. When the control voltage is less than the triangular wave voltage, the lower thyristor T A- is conducting. Figure 13: PI Controller outputs Mini-project 15a 13

The scope readings below shows the effects of the LCL filter. This gives us a THD of 8,98 %. Figure 14: PI controller ripple and load measurements Figure 15: PI Controller THD This setup gives us average IGBT losses of 1506 W and average diode losses of 73 W, giving a total loss of 1579 W. Mini-project 15a 14

5.2.2 HYSTERESIS CURRENT CONTROLLER WITH F S = 20 KHZ Using the hysteresis current controller and the same LCL filter values, gave us an average switching frequency of 21 khz. The scope readings below show us how the hysteresis current controller works. If the actual current tries to go beyond the upper tolerance band, T A- is turned on to reduce the current. The opposite switching occurs if the actual current tries to go below the lower tolerance band. Figure 16: Hysteresis Controller outputs The scope readings below shows the effects of the LCL filter. Figure 17: Hysteresis controller ripple and load measurements Mini-project 15a 15

This gives us an acceptable THD of 3 %. Figure 18: Hysteresis Controller THD This setup gives us average IGBT losses of 1691 W and average diode losses of 76 W, giving a total loss of 1767 W. Mini-project 15a 16

Total Losses (IGBT and Diode) [W] Switching frequency [Hz] Active Rectifier in Microgrid 5.2.3 COMPARISONS The figure below shows the effects of the switching frequency to the filter inductance. It shows that as we increase the switching frequency, the value that we need for the filter inductance decreases. It is also important to notice that the hysteresis current controller gives out higher average switching frequency than the PWM PI current controller at similar filter inductance values. 25000 20000 15000 10000 PWM PI CC Hysteresis CC 5000 0 25 28 33 40 50 Filter Inductance Ls [mh] Figure 19: Filter inductance vs switching frequency The figure below shows the effects of the switching frequency to the total loss (in the diode and the transistors). 2000 1800 1600 1400 1200 1000 800 600 400 200 0 PWM PI CC Hysteresis CC Switching Frequency [Hz] Figure 20: Switching frequency vs total losses Mini-project 15a 17

The figure below shows us the effects of variations in the hysteresis band in a hysteresis current controller. This shows us that the THD in a hysteresis current controller is mainly dependent on the hysteresis band. If the hysteresis band increases, THD also increases, but the switching frequency decreases, which gives less switching losses. 4,50 4,00 3,50 3,00 2,50 2,00 1,50 1,00 0,50 0,00 9,90 14,84 19,80 24,75 29,70 Hysteresis Band [A] fs [10^4 Hz] Power loss [kw] THD [%] Figure 21: Hysteresis band variation effects Mini-project 15a 18

6 CONCLUSION Current control techniques can be divided into two groups: linear (PI Controller) and non-linear controllers (Hysteresis CC). The basic principles of these techniques have been described in the report. Both have its advantages and limitations. The advantage of the PI controller is that it gives out constant switching frequency, which provides a stable operation of the inverter. The main disadvantage of this technique is an inherent tracking (amplitude and phase) error. The advantage of the hysteresis band controller lies in its simplicity and its providing of excellent dynamic performance. On the other hand, the disadvantage is that the switching frequency varies, providing irregular operation of the inverter. As a result the switching losses are increased. In addition to studying the two current control techniques, the project group also studied how to dimension a LCL filter and how to calculate power losses in the IGBT and the diode. Mini-project 15a 19

7 REFERENCES [1] Current Control Techniques for Three-Phase Voltage-Source PWM Converters: A Survey; Kazmierkowski and Malesani [2] Performance Analysis of Differrent Current Control Techniques for VSI connected to R-L Load; Ch.Nagarjuna Reddy, B.Vasanth Reddy, B.Chitti Babu [3] A method of tracking the peak power points for a variable speed wind energy conversion system, ; Datta and Ranganathan [4] Power Electronics; Mohan, Undeland and Robbins 8 LISTS OF FIGURES, TABLES AND ABBREVIATIONS LIST OF FIGURES AND TABLES: Figure 1 Three-phase inverter p. 4 Figure 2 PWM Current Controller p. 5 Figure 3 PI PWM current controller p. 5 Figure 4 Hysteresis current controller p. 6 Figure 5 Three-phase inverter with LCL filter p. 6 Figure 6 Calculating dynamic resistance values p. 9 Figure 7 Simulation model p. 10 Figure 8 Current controllers p. 10 Figure 9 Switching frequency checker p. 11 Figure 10 Power loss calculations p. 11 Figure 11 Conduction loss calculations p. 12 Figure 12 Switching loss calculations p. 12 Figure 13 PI Controller outputs p. 13 Figure 14 PI controller ripple and load measurements p. 14 Figure 15 PI Controller THD p. 14 Figure 16 Hysteresis Controller outputs p. 15 Figure 17 Hysteresis controller ripple and load measurements p. 15 Figure 18 Hysteresis controller THD p. 16 Figure 19 Filter inductance vs switching frequency p. 17 Figure 20 Switching frequency vs total losses p. 17 Figure 21 Hysteresis band variation effects s. 3 Table 1 LCL Filter for fs = 20 khz p. 13 LIST OF ABBREVIATIONS THD: Total Harmonic Distortion IGBT: Insulated Gate Bipolar Transistor fs: switching frequency CC: Current Controller DG: Distributed Generation PWM: Pulse Width Modulation Mini-project 15a 20

9 APPENDIX A: IGBT with anti parallel diode datasheet - Infineon IKW40T120 B: PI CC model (Simulink file) C: PI CC data inputs for model (Matlab file) D: Hysteresis CC model (Simulink file) E: Hysteresis CC data inputs for model (Matlab file) Mini-project 15a 21