The OPUS AutoCuff System for Rotator Cuff Repair

Similar documents
LabraLock P for Labrum Repair, LabraFix System. The Reinforcement Technique Guide

Double Row Rotator Cuff Repair. Surgical Protocol by Frank Bonnarens, M.D.

Double Row Rotator Cuff Repair. Surgical Protocol by Frank Bonnarens, M.D.

Super Revo. Surgical Technique. Super Revo Shoulder Fixation System. The Ideal Fixation Device For Rotator Cuff Repair. Self-drilling, titanium anchor

ARTHROSCOPIC ROTATOR CUFF REPAIR SURGICAL TECHNIQUE. The following techniques are described by Vernon J. Cooley, M.D.

VERSALOK. Suture Anchor. Rotator Cuff Repair Surgical Technique

Knotless SutureTak Instability Repair. Surgical Technique

Product Pamphlet. Parcus Medical s Value Proposition Program is designed to reduce cost per case by:

Dr. S.D. Gerber Double Row Method Surgical Technique

Rotator Cuff Repair ICONN Answer PEEK Suture Anchor 4.75/5.5. Surgical Protocol by Geoffrey Connor, 4.75/5.5 MD of D1 Sports Medicine

High polish finish. Complete line of biters, tissue graspers

Small Plate and Screw System SURGICAL TECHNIQUE

Arthroscopic Protector Meniscus Suturing Surgical Techniques

Ankle Fracture System. Surgical Technique STRENGTH FROM WITHIN

MTP Set SURGICAL TECHNIQUE

Technique Guide. Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

Champion Instrumentation. Shoulder Repair Made Simpler

Integra. Capture Screw System SURGICAL TECHNIQUE

TORNIER MAXLOCK EXTREME. Clavicle Plating System SURGICAL TECHNIQUE

Arthroscopic Rotator Cuff Repair

Knotless Bankart Repair Using the Labral SwiveLock. and FiberStick. Surgical Technique. Labral SwiveLock

The Percutaneous Reduction Forceps Technique Guide

MIS TECHNOLOGY GUIDE READ PRODUCT INSERT THOROUGHLY BEFORE USE

Lag Screw Device TECHNIQUE GUIDE. Indicated for symphyseal fracture fixation of the mandible. Instruments and implants approved by the AO Foundation

Integra. Stainless Headed Compression Screw System SURGICAL TECHNIQUE

MTP Fusion Surgical Technique

ExpresSew II. Intuition redefined.

Suture anchors for VeterinarY use

Anterior Cervical Plate SURGICAL TECHNIQUE GUIDE. Surgeon Driven Innovation

Replacing the Reciprocator on the SWF Compact Series Machine (601C and 1201C)

S 4. Aesculap. Spinal System. Percutaneous Approach Surgical Technique. Aesculap Spine

Surgical Technique. Customer Service:

ISO Plate SURGICAL TECHNIQUE

Interlagos Retractor System Surgical Technique

Aesculap Spine S 4 Spinal System. Instrumentation Guide

Surgical Technique Guide

OPERATIVE TECHNIQUE RIVAL REDUCE FRACTURE PLATING SYSTEM. foot & ankle trauma procedures

Technique Guide. Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

Back to health. Back to work. Back to life.

Orthopedic Bone Nail System Universal Humeral Nail

RTI TECHNOLOGIES, INC.

INSTRUCTION MANUAL. In vivo Test Apparatus for 305B Muscle Lever Systems

Prostar XL Percutaneous Vascular Surgical Device

Techniques of the hand tie and instrument tie

Surgical Technique. Acutrak Headless Compression Screw System

BioPlug 5.2 SPS Secure Portal System

Cervical Solutions. Lineum OCT. Spine System. Surgical Technique Guide

A free-extending two part cannulated screw that will elongate with growth. SURGICAL TECHNIQUE

Universal Humeral Nail

Minimally Invasive Suturing Devices

Mecron Cannulated Screws

ACLP Anterior Cervical Locking Plate System TECHNIQUE GUIDE

Reflex Hybrid System Overview

600mm COMPOUND MITRE SAW ASSEMBLY INSTRUCTIONS. MODEL NO: MBS600D Part No: GC05/12

D. Greg Anderson, MD Thomas Jefferson University Hospital Philadelphia, PA

The wick in your heater needs replacing if, after repeated cleanings, any of the following conditions still exist:

Arthrex. Bio-Compression. Screw System. Knee OCD. Hand, Wrist & Elbow. Foot & Ankle

Perclose ProGlide. Deployment Steps. Suture-Mediated Closure System Abbott. All rights reserved. ANZ /11

VECTRA SURGICAL TECHNIQUE. Anterior cervical plate system. This publication is not intended for distribution in the USA.

Peanut Growth Control Plating System. Surgical Technique

5th Metatarsal Fracture System Surgical Technique

LCD LIFT Flat Panel Display System Installation Manual. Table of Contents

Strata. urniture. Adriana Instructions. Parts in the Arm Box: Parts in the Body Box: Watch our assembly videos at

For Minimally Invasive Application of Cerclage Wires. Cerclage Passer. Surgical Technique

Depending on the size you ordered you will have either 5 Foot sections which will build the 10 Foot frame or 6 Foot sections which will build the 12

Humeral Nail System Procedural Steps.

Technique Guide. Variable Angle LCP Opening Wedge Plates 2.4/2.7. Part of the Variable Angle LCP Forefoot / Midfoot System 2.4 / 2.7.

Footprint Mobile Assembly Instructions

STEINBERGER TRANSTREM (TYPE 2) TECHNICAL DOCUMENT

INSTRUCTIONS FOR USE

Instruments for Removing DePuy Synthes Screws. Screw Removal Set

STOP! READ THIS FIRST

INSTALLATION GUIDE 2009-CURRENT HUMMER H3T PRODUCT CODE:

PERSONAL RECORD KEEPING

OPERATIVE TECHNIQUE RIVAL BITE HEADED CANNULATED AND HEADLESS COMPRESSION SCREWS. foot & ankle applications

Strata. urniture. Mission Rim Instructions. Parts in the Arm Box: Parts in the Body Box:

Objectives. xxx00.#####.ppt 5/10/17 9:42 AM

OPERATIVE TECHNIQUE RIVAL VIEW PLATING SYSTEM. foot & ankle reconstruction procedures

OWNER'S MANUAL Issue 2 - December 14, 2000

General Wood Shop Notes

MEDIALMAX System SURGICAL TECHNIQUE

Surgical Technique ANAX TM OCT. Spinal System

PARS Achilles Jig System

Signal Mirror Installation Instructions Honda Odyssey

Continuum Frame Assembly Instructions

Digital Compression Screw

TABLE OF CONTENTS REQUIRED TOOLS

LEG CURL IP-S1315 INSTALLATION INSTRUCTIONS

PERSONAL RECORD KEEPING

MaxTorque. surgical technique. Cannulated Screw System. Foot & Ankle. OrthoHelix Technology

Operasjonsteknikk. Retrograd Femur

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

Distal Fibula Plate SURGICAL TECHNIQUE

Sentinel Series Cigar Humidor End Tables

Surgical Technique 1

VECTRA. SURGICAL TECHNIQUE. Anterior cervical plate system. This publication is not intended for distribution in the USA.

Proximal Femur Nailing System Surgical Technique. fix.com

The Bowflex Revolution XP Home Gym Assembly Instructions. P/N: Rev ( /0 )

Tyler Alignment & Calibration System For the Leksell Stereotactic Frame

Signal Mirror Installation Instructions

Transcription:

The OPUS AutoCuff System for Rotator Cuff Repair A revolutionary new system specifically designed for rotator cuff repair surgery System Includes: SmartStitch Suturing Device The Magnum PI Implant with Inserter Handle Magnum PI Undercut Punch Magnum PI Drill Bit or Magnum PI Punch Technique Guide

The System The AutoCuff System with Magnum PI implant from ArthroCare Sports Medicine s OPUS Collection is a state-of-the-art system specifically designed for rotator cuff repair surgery. The AutoCuff System enables the surgeon to perform a secure knotless repair of the rotator cuff and restore the anatomic footprint with an unparalled TensionLock mechanism through a rapid and consistent arthroscopic or mini-open procedure. The system consists of these innovative devices: The SmartStitch suturing device and the Magnum PI implant with inserter handle. Accessories include the Magnum PI undercut punch, drill bit and punch, as well as the AutoCuff drill guide and PathFinder set. The SmartStitch Suturing Device The SmartStitch suturing device (below) is an integrated grasper and suturing device that allows the surgeon to grasp the cuff tissue and place an Incline Mattress or side-to-side stitch in the tissue in a matter of seconds. The SmartStitch suturing device consists of a reusable suturing device handle and a single use M-Connector or PerfectPasser Connector. In addition, the suture is provided as a prepackaged suture cartridge. The suture material used with the Magnum PI is MagnumWire, an ultra-high strength #2 braided polyethylene suture available in multiple colors to facilitate suture management. SmartStitch Suturing Device with PerfectPasser Connector Perfect Passer (OM-8010) Suturing Device Handle (OM-8000) Connector Release Button Suture Cartridge (OM-817X) Needle Driver Lever Clamp Jaw Lever Ratchet Release Lever M-Connector (OM-8007) SmartStitch Suturing Device with M-Connector

The Magnum PI Undercut Bone Punch The Magnum PI Undercut Bone Punch was specifically engineered for use with the Magnum PI implant. After drilling or punching the implant holes the undercut punch cleanly places a trough in the bone for the Magnum PI implant to deploy. The lock out mechanism prevents the wings of the undercut punch from deploying during insertion or removal. Magnum PI Undercut Punch (OM-9450) Pin in Slot Probe Nut Probe Handle Lock Out Trigger Undercut Punch Lever The Magnum PI Implant The Magnum PI implant (below) is a compact, radiolucent implant made with PEEK-OPTIMA polymer that, when used with the Magnum PI undercut punch and Magnum PI inserter handle, achieves a strong bone lock, provides a ratchet mechanism, TensionLock, that transports the rotator cuff tissue to the prepared footprint and applies and maintains tension on the sutures for the ideal tendon to bone fixation. Magnum PI Implant (OM-4500) Suture Ratchet Knobs Suture Lock Button Magnum PI Implant Ratchet Release Button Distal Snare Ring Suture Support Distal Snare Wire Loop Hand Lever Disposable Inserter Handle

SmartStitch Preparation Coupling the Disposable Connector (OM-8007 or OM-8010) with the SmartStitch Handle Remove Connector from its sterile packaging. Take care not to remove the tip protector until the Connector is coupled with the SmartStitch handle. Step 4 Step 5 Squeeze and lock the silver clamp jaw lever of the SmartStitch handle in the closed position. Insert the molded end of the Connector into the handle until it locks into position. For the M-Connector, remove the tip protector by lifting the locking tab, rotating 1/4 turn and gently sliding off. For the PerfectPasser Connector, remove the tip protector by lifting the wings of the plastic tip protector and gently pulling it off. Both the clamp jaw lever and the needle driver lever are actuated to test controls. The silver clamp jaw lever operates the jaw of the SmartStitch, while the gold needle driver lever operates the suture needles. Press the ratchet release lever to unlock the clamp jaw lever. Step 4 Step 5 Loading the SmartStitch MagnumWire Suture Cartridge Step 6 Remove the suture cartridge (OM-807X or OM-817X) from its sterile packaging and carefully insert it into the barrel of the Connector. Take care not to kink the plastic tubing. Step 6 Step 7 Snap the plastic molded end of the suture cartridge on to the end of the Connector. The SmartStitch suturing device is now ready to use. Only MagnumWire USP #2 non-absorbable braided suture may be used with the Magnum PI implant. Using other suture may compromise suture lock. Step 7

Surgical Technique Placing the Incline Mattress Stitch Insert the SmartStitch through the lateral portal, usually without a cannula (if a cannula is desired, it must be min. 8.2mm). Grasp the prepared edge of the tendon using the silver clamp jaw lever. Activate the needles by completely squeezing the gold needle driver lever once, followed by a slow release. Release the jaw using the ratchet release lever, and withdraw the SmartStitch from the operative site. This completes placement of the first Incline Mattress stitch. Disengage the sutures from the SmartStitch needles by squeezing the gold needle driver lever halfway and pulling the sutures up and towards the handle for the M-Connector, or down and towards the handle for the PerfectPasser Connector. If another stitch is needed, load the SmartStitch with a fresh suture cartridge. All sutures are placed first before creating implant holes. M-Connector Stitch The SmartStitch places an Incline Mattress stitch in the cuff tissue. In addition to providing an extremely strong hold in the cuff tissue (comparable to a modified Mason-Allen 1 ), the Incline Mattress configuration also creates a downward force, compressing the tissue against the bone when the sutures are tensioned. 4.5mm Spacing Exit Point 11mm Entry Point 13mm PerfectPasser Connector Stitch The SmartStitch with PerfectPasser Connector allows for an even deeper bite to place an ideal stitch for double row repairs. If a wider stitch or margin convergence is needed, the independent needle deployment of the PerfectPasser Connector enables placement of both sides of the stitch, at variable widths, in one portal entry. 1 T. Schlegel, MD; R. Hawkins, MD; C. Lewis, A. Turner. An In Vivo Comparison of the Modified Mason Allen versus a Horizontal Mattress Stitch on Tendon Healing to Bone; A Biomechnical and Histological Study in Sheep. Journal of Shoulder and Elbow Surgery 2007; 16: 115-121. 4.5mm Spacing Exit Point 16mm Entry Point 18mm

Creating Drill/Punch Holes for the Magnum PI Implant The drill hole sites are planned by applying traction on the suture limbs. The cuff footprint is prepared by removing all soft tissue and creating a smooth bone surface. It is important not to decorticate bone in the vicinity of the implant sites as the Magnum PI relies on an intact cortical layer for bone fixation. Make the implant holes perpendicular to the bone surface (as opposed to a 45 degree angle); this ensures optimal fixation by the Magnum PI implant (figure 1). If a perpendicular angle cannot be achieved through the standard lateral portal, it is recommended that an additional superolateral portal be made, closer to the acromion border. The perpendicular alignment should be confirmed with a spinal needle prior to creating the portal. Insert the AutoCuff drill guide, with blunt obturator, through the portal used to create the holes. Figure 1 Remove the blunt obturator and, using a suture retriever through the drill guide, shuttle one pair of sutures into the portal. Hold the sutures away in the slot of the drill guide. Make the drill holes using the Magnum PI drill bit (green) or Magnum PI punch (green) through the drill guide. It is important to penetrate the bone up to the collar of the drill (or punch) in order to achieve the correct depth for deployment of the Magnum PI implant. Step 4 Once the hole is made, remove the drill (or punch). Optionally, insert the AutoCuff PathFinder into the hole to maintain alignment while the Magnum PI Undercut Bone Punch is prepared for insertion. If placing more than one implant, assure bone holes are at least 5mm apart. The OPUS Magnum PI Undercut Bone Punch Assemble the Magnum PI undercut punch probe into the undercut punch handle by aligning the pin on the probe with the slot on the handle while compressing the lockout trigger. Screw the probe nut all the way so that the pin is fully seated in the back of the slot while continuing to compress the lockout trigger. Insert the undercut punch into the bone hole until the shaft is fully seated against the bone, pointing the directional indicator towards suture insertion into the cuff. Pull the lockout trigger with a downward motion then squeeze and return the undercut punch lever fully to create an undercut in the bone hole. Once the undercut is created, confirm that the undercut punch is in the locked position and remove it from the bone hole. Optionally, insert the AutoCuff PathFinder into the hole to maintain alignment with the bone hold. Remove the PathFinder prior to inserting the Magnum PI implant. The lockout trigger cannot be pulled if there is pressure on the undercut punch lever.

Surgical Technique Deploying the Magnum PI Implant Pass both limbs of the stitch through the distal snare wire loop of the Magnum PI handle. Remove the distal snare ring and evenly adjust both suture ends so that approximately two inches of suture extend from the distal end of the Magnum PI handle. c Take up suture slack by rotating the suture ratchet knobs in the direction of the arrows on the inserter handle. Remove the PathFinder and insert the Magnum PI into the pre-drilled (or punched) hole with the arrows on the suture support shaft aligned towards the rotator cuff. It is important to maintain perpendicular alignment during insertion of the Magnum PI. Insert the Magnum PI until the suture support shaft is fully seated against the bone. Step 4 Rotate the suture ratchet knobs again to take up further suture slack until the entire length of suture is clearly visible, from the cuff tissue to the collar of the suture support shaft. Activate the bone lock by a single squeeze of the black hand lever. Verify bone purchase with a firm tug. Step 4

. Step 5 Tension the sutures by rotating the suture ratchet knobs with both hands in the direction of the arrows on the inserter handle. Step 5 Step 6 When adequate tension between tendon and bone is achieved, press the suture lock button on the side of the inserter handle. Step 6 Step 7 Squeeze the black hand lever and release three times to activate the suture lock and allow withdrawal of the inserter handle. Step 7 3x Step 8 Trim the sutures at the bone hole to complete the AutoCuff repair. Step 8 The above sequence is repeated to place the desired number of implants to complete the rotator cuff repair. To order or for more information, please contact your ArthroCare Sports Medicine representative or customer service at 800-797-6520. ArthroCare Sports Medicine 680 Vaqueros Avenue Sunnyvale, CA 94085-3523 order entry 800-797-6520 phone 408-736-0224 order entry fax 888-994-2782 arthrocaresportsmedicine.com ArthroCare Europe AB Baggensgatan 25 111 31 Stockholm Sweden phone +46 8 546 172 00 fax +46 8 546 172 39 info@arthrocare.se CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician. 2008 ArthroCare Corporation. All rights reserved. All trademarks, service marks and logos listed herein are registered and unregistered trademarks of ArthroCare Corporation, its affiliates or subsidiaries or a third party who has licensed its trademarks to ArthroCare. PEEK-OPTIMA, Invibio, Biomaterial Solutions and the Invibio logos are trademarks and/or registered trademarks of Invibio Ltd. P/N A1052 Rev B