Application Note. GPSG-1000 Dual RF Channel Operation

Similar documents
Understanding the Precision Antenna, Cable, and Power Measurements on the 3550 Radio Test System

Extending test capabilities of the PXI 3000 RF test solution with 3060 Series RF combiner modules

Antenna Coupler. On the XY Shuttle, the mobile phone can be fixed in 25 positions from the top-right to the bottom-left corner

LTE Radio Channel Emulation for LTE User. Equipment Testing

Microwave. Accessories for Microwave Scalar and System Analyzers

A passion for performance. Vector. Digital. Analog. MultiSource VXI. Signal. Sources

Installed Radio Testing with the 3500

PXI. DFS Radar Simulator and Analyzer Test Suite

Avionics. IFR 4000 Nav/Comm Test Set

Avionics. IFR 4000 Nav/Comm Test Set

Spectrum Analyzers. 2394A 1 khz to 13.2 GHz Spectrum Analyzer.

Signal Sources. 2026A/B 10 khz to 2.05/2.51 GHz MultiSource Generator

Signal Sources. 2026A/B 10 khz to 2.05/2.51 GHz MultiSource Generator

Signal Sources. 2026Q CDMA Interferer Multisource Generator. Advanced Test Equipment Rentals ATEC (2832)

Application Note. ACT5028 Resolver-To-Digital Converter (RDC) Evaluation Board. Application Note AN5028-1

Using the 2975 to perform Control Channel Logging

Signal Sources Series Low Noise Signal Generator

PXI-based Radio Communications Testing

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

AC/DC Current Probe TCP0150 Datasheet

Application Note. Understanding PassPort Radio Systems

PXI Modules PXI Digital RF Signal Generator.

Verifying Power Supply Sequencing with an 8-Channel Oscilloscope APPLICATION NOTE

MLS-800 Microprocessor Controlled Ground Station Simulator

Debugging SENT Automotive Buses with an Oscilloscope APPLICATION NOTE

Keysight Technologies How to Take Fast, Simultaneous Measurements of Two or More Signals Using BenchVue Software. Application Note

Signal Sources Series Signal generators

Using the IFR 2975 for Advanced Project 25 Keyloading Capabilities and AES/DES Encryption

khz to 2.9 GHz Spectrum Analyzer

Agilent 4294A Precision Impedance Analyzer, 40 Hz to 110 MHz. Configuration Guide

Avionics. IFR 6000 Ramp Test Set

Keysight Technologies Making Field Effect Transistor Characterization Using SMU

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

Keysight E5063A ENA Series Network Analyzer

30 A AC/DC Current Probe TCP0030A Datasheet

5100 T/R Module Test Environment

Application Note. Testing SmartNet TM /SmartZone TM Systems. Rob Barden Senior Product Marketing Manager

Agilent Correlation between TDR oscilloscope and VNA generated time domain waveform

Preliminary. PXI Modules Wideband RF Digitizer.

Agilent Maximizing Measurement Speed Using P-Series Power Meters

Low Cost RF Sensors. application note

Agilent 8762F Coaxial Switch 75 ohm

Keysight Technologies Using an External Trigger to Generate Pulses with the B2960A

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz

AC Current Probes CT1 CT2 CT6 Data Sheet

Data Sheet. Agilent M9185A PXI Isolated D/A Converter. DISCOVER the Alternatives... Agilent MODULAR Products. 8/16-Channel 16-bit, ±16 V

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

NI 6624 Calibration Procedure

Agilent N8480 Series Thermocouple Power Sensors. Technical Overview

Keysight E5063A ENA Vector Network Analyzer

Agilent N9344C/N9343C/N9342C Handheld Spectrum Analyzer (HSA)

Making a S11 and S21 Measurement Using the Agilent N9340A

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet

Agilent U9397A/C FET Solid State Switches (SPDT)

Fast Switching Synthesizers

Keysight Technologies N9063A & W9063A Analog Demodulation

Introduction. Part 1. Introduction...2

Rubidium Frequency Standard Model AR133A Ruggedized Low Profile

Automated Frequency Response Measurement with AFG31000, MDO3000 and TekBench Instrument Control Software APPLICATION NOTE

AN3332 Application note

Agilent E4438C/E8267D Option 422 Scenario Generator for GPS

Agilent PNA Series RF Network Analyzers

Spectrum Analyzers Series 1 khz to 26.5 GHz Spectrum Analyzers. Advanced Test Equipment Rentals ATEC (2832)

PXI Modules. 3030A Wideband RF Digitizer.

Don t Let EMI/EMC Compliance Certification Slow You Down TUTORIAL

BNC-2121 Connector Accessory for 660X Devices

Agilent 87075C Multiport Test Set

Agilent 84904, 6, 7K/L Programmable Step Attenuators

N2750A/51A/52A InfiniiMode Differential Active Probes

PAPER. SISO to MIMO: Moving Communications from Single-Input Single-Output to Multiple-Input Multiple-Output

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

Compact, easy to use, high performance signal generator for R&D, manufacturing and the field

Wireless Portable Radio Communications Test Set. Advanced Test Equipment Rentals ATEC (2832)

Evaluating and Optimizing Radio Frequency Identification (RFID) Systems Using Real-Time Spectrum Analysis

NI sbrio-9632/9642 Verification Procedure

TX CONTROLLER Model EM-IP Quick Start Guide

P7600 Series TriMode Probes

Using the Model 4225-RPM Remote Amplifier/ Switch to Automate Switching Between DC I-V, C-V, and Pulsed I-V Measurements APPLICATION NOTE

Agilent 83440B/C/D High-Speed Lightwave Converters

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer

74AC74B DUAL D-TYPE FLIP FLOP WITH PRESET AND CLEAR

Keysight Technologies x1149 Boundary Scan Analyzer. Data Sheet

Pulsed Measurement Capability of Copper Mountain Technologies VNAs

Keysight Technologies Electronic Calibration (ECal) Modules for Vector Network Analyzers

Differential Probes P6248 P6247 P6246 Datasheet

Agilent U9391C/F/G Comb Generators

Keysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes. Data Sheet

12.5 Gb/s Driver Amplifier LABware Module PSPL8001 Datasheet

TekConnect Adapters TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM TCA292D Datasheet

Soldering a P7500 to a Nexus DDR Component Interposer

Performing Safe Operating Area Analysis on MOSFETs and Other Switching Devices with an Oscilloscope APPLICATION NOTE

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Keysight Technologies 8490G Coaxial Attenuators. Technical Overview

Keysight Technologies RS-232/UART Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes. Data Sheet

Field Service Spares Procedure Replacement Coax Switch Kit, 8897B, 9497B, 14400B, ST88, ST94 & ST144

Keysight M9485A PXIe Multiport Vector Network Analyzer

Agilent 8761A/B Microwave Switches

N2820A/21A High-Sensitivity, High Dynamic Range Current Probes

Transcription:

Application Note GPSG-1000 Dual RF Channel Operation Some GPS receivers require 2 GPS channels to be present at the same time for proper GPS signal reception. For example; a dual channel GPS receiver designed for L1 and L2C operation. This can be accomplished by using two GPSG-1000 units simultaneously in order that the outputs of the units, each operating on a different RF channel, can be combined to provide a single synchronized RF output. This Application Note defines the procedure to synchronize two GPSG-1000 units and combine the RF channel outputs. For the very latest specifications visit www.aeroflex.com

Equipment required for combining and operating two GPSG-1000 signals simultaneously. Nomenclature QTY Part Number (or type) Aeroflex GPSG-10000 w/ RF Combiner Firmware ver 1.02 or later and Software ver 2.5.0 or later. 02 Aeroflex 87339 26 pin Sub D plug connector 02 Positronic WDD26P2 (example) Combiner 3 way, GPSG 01 Aeroflex 90948 Cables and adapters to inter-connect the GPSG 1000 units and other required equipment As req Any, Coax cables should be 50 Ω impedance, matched in length (±3 ), and short as possible (<10 ). The 10 MHz reference cable should be < 3 ). Pulse Generator capable of outputting a 3.3 V pulse with 100 usec pulse width 01 Agilent 33220A (example) Oscilloscope 500 MHz BW 01 Tektronix TDS3000C (example) See Figure 1 for equipment interconnection. The interface cables for the AUX connectors on the GPSG-1000 units will be locally fabricated. Note: The RF Combiner Firmware version may be checked in the following manner: 1. From the Launch Bar select System, then System Configuration. 2. On the System Configuration screen select the Hardware tab from the top edge of the display. This displays all hardware ID and Firmware versions. Find RF Combiner Firmware Version on the list. Note: The GPSG-1000 Software version may be checked in the following manner: 1. From the Launch Bar select System, then System Update. 2. The GPSG-1000 software version is displayed at the bottom of the System Update screen.

Figure 1 Simulation set up: 1. Both GPSG-1000 units must be using the same almanac data. Please ensure the almanacs are the same for both units before continuing. 3. Set up the pulse generator to provide a manually triggered one time pulse. The pulse should be set up as per Figure 2. 2. Set up and connect equipment as per Figure 1. Ensuring that the cables used to connect the pulse generator to the GPSG-1000 units and the 1PPS output of the GPSG-1000 units to the Oscilloscope are equal length (±3 ). For the very latest specifications visit www.aeroflex.com

Figure 2 Figure 4 4. On GPSG-1000 #1 Menu Bar select Setup. On the Setup screen at the top row select the I/O tab. Set Ext Ref Out to ON, Reference Source to INT, and Trigger to External. See Figure 3. 6. On both GPSG-1000 units Setup screen select he Simulation tab. Set the Simulated Start Time fields to the same values. Set the RF Output, RF Level to the same value. See Figure 5. Figure 3 Figure 5 5. On GPSG-1000 #2 Menu Bar select Setup. On the Setup screen at the top row select the I/O tab. Set Ext Ref Out to OFF, Reference Source to EXT, and Trigger to External. See Figure 4. 7. On the GPSG-1000 #1 Setup screen in the GNSS fields, set GNSS to GPS+Galileo and Carrier to L1/E1. See Figure 5. 8. On GPSG-1000 #2 Setup Screen in the GNSS fields, set GNSS and Carrier to the other required carrier type and frequency for your multi channel GPS LRU. See Figure 6.

Figure 6 Figure 8 9. On both GPSG-1000 units Menu Bar select Simulation. On the Simulation screen PVT fields set the Latitude, Longitude, and Altitude fields to the same values. See Figure 7. 11. Using the Pulse Generator, send a single pulse to trigger the GPSG-1000 units. You should now note that the time and date data on the Simulation screen is updating and match on both units. End of simulation set up. Simulation Troubleshooting If the GPS receiver fails to identify its position after a suitable period for the receiver to acquire the signals, please perform the following troubleshooting steps. 1. Verify the GPSG-1000 units connections and interface as per Figure 1. 2. Verify both GPSG-1000 units setup as per this Application Note. Figure 7 10. On both GPSG-1000 units Simulation screen press the Run switch. You should note that both GPSG-1000 units configure the simulation, but, the time and date data on the Simulation screen should not update. See Figure 8. 3. Set the Oscilloscope, connected as per Figure 1, to measure the leading edges of the 1 PPS signal from both GPSG-1000 units. Note the difference between the points that both 1 PPS signals begin to rise from their 0 VDC states. The time difference should be less than 10 nsec. Note: This step confirms that the GPSG-1000 units are operating in sync. If the time difference is not correct, then check the set up and try again. For the very latest specifications visit www.aeroflex.com

CHINA Beijing Tel: [+86] (10) 6539 1166 Fax: [+86] (10) 6539 1778 CHINA Shanghai Tel: [+86] 21 2028 3588 Fax: [+86] 21 2028 3558 CHINA Shenzhen Tel: [+86] (755) 3301 9358 Fax: [+86] (755) 3301 9356 FINLAND Tel: [+358] (9) 2709 5541 Fax: [+358] (9) 804 2441 FRANCE Tel: [+33] 1 60 79 96 00 Fax: [+33] 1 60 77 69 22 GERMANY Tel: [+49] 89 99641 0 Fax: [+49] 89 99641 160 HONG KONG Tel: [+852] 2832 7988 Fax: [+852] 2834 5364 INDIA Tel: [+91] 80 [4] 115 4501 Fax: [+91] 80 [4] 115 4502 JAPAN Tel: [+81] (3) 3500 5591 Fax: [+81] (3) 3500 5592 KOREA Tel: [+82] (2) 3424 2719 Fax: [+82] (2) 3424 8620 SCANDINAVIA Tel: [+45] 9614 0045 Fax: [+45] 9614 0047 SINGAPORE Tel: [+65] 6873 0991 Fax: [+65] 6873 0992 TAIWAN Tel: [+886] 2 2698 8058 Fax: [+886] 2 2698 8050 UK Stevenage Tel: [+44] (0) 1438 742200 Fax: [+44] (0) 1438 727601 Freephone: 0800 282388 USA Tel: [+1] (316) 522 4981 Fax: [+1] (316) 522 1360 Toll Free: 800 835 2352 As we are always seeking to improve our products, the information in this document gives only a general indication of the product capacity, performance and suitability, none of which shall form part of any contract. We reserve the right to make design changes without notice. All trademarks are acknowledged. Parent company Aeroflex, Inc. Aeroflex 2011. www.aeroflex.com info-test@aeroflex.com Part No. 46900/808, Issue 1, 07/12