ACCREDITED LABORATORY. LIBERTY LABS, INC. Kimballton, IA for technical competence in the field of Calibration

CTAG:b01ac469edcbee4d9e5f84a83a1962a5 Certificate of Calibration

CIPM and CCPR What are these organizations and how do they affect my testing results. Maria Nadal Photometry, Surface Color and Appearance NIST

Electronic Calibration (ECal) Modules for Vector Network Analyzers

Peter Dack, Vice President Sales & Marketing Radian Research, Inc.

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TIME AND FREQUENCY METROLOGY

PM Series Microwave Power Calibration System

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

Joint ILAC CIPM Communication regarding the. Accreditation of Calibration and Measurement Services. of National Metrology Institutes.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z & ANSI/NCSLI Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

APMP GUIDELINES FOR ACCEPTING A QUALITY SYSTEM(V.2.0 WD2) approved on July 2010

0.017 % % %

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z & ANSI/NCSLI Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI/NCSL Z & ANSI/NCSL Z540.3

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z & ANSI/NCSL Z

Keysight Technologies Optical Power Meter Head Special Calibrations. Brochure

Calibration Certificate

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Designated Institutes participating in the CIPM MRA

CALIBRATION CMC 2, 4 ( )

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI/NCSL Z & ANSI/NCSLI Z

CERTIFICATE OF CALIBRATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Agilent 4-Port PNA-L Network Analyzers

Agilent Z540.3 Compliance

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI/NCSL Z & ANSI/NCSLI Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Calibration Laboratory Assessment Service CLAS Certificate Number Page 1 of 10

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

FCC 47 CFR PART 15 SUBPART B

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

N8480 Series Thermocouple Power Sensors DATA SHEET

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI/NCSL Z & ANSI/NCSL Z

ELECTRONICS TESTING CENTER, TAIWAN

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ZETEC, INCORPORATED 875, boul. Charest ouest, Suite 100 Quebec, QC, G1N 2C9 CANADA

Palstar, Inc. EMC TEST REPORT FOR. HF LDMOS Amplifier Model: LA-1K. Tested To The Following Standard: FCC Part 97 Subpart D. Report No.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Internationally accepted framework for metrology

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

Itron, Inc. TEST REPORT FOR. RF Telemetry Device Model: CCU100. Tested To The Following Standards:

C E R T I F I C A T I O N

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Errata to Procedural Standard for Sound & Vibration Measurement 2015 Third Edition

Keysight 2-Port and 4-Port PNA-X Network Analyzer

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z540.3

2-3 Calibration of Standard Voltage and Current Generator

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AMETEK CO., LTD. NAGOYA OFFICE. (Main Laboratory) Onna, Atsugi-shi, Kanagawa-ken, Japan

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z

Laird Attn: Bill Steinike W66 N220 Commerce Ct. Cedarburg, WI Report Constructed by: Zach Wilson, EMC Technician Signature: Date: June 21, 2017

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

EMC Bayswater Pty Ltd. EMC COMPLIANCE REPORT In accordance with: AS/NZS CISPR 15: Indice Ecotech Pty Ltd. 14W LED Downlight

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

TEST REPORT. Table of Contents

TEST REPORT. Table of Contents

ACCREDITED LABORATORY

APMP KEY COMPARISON APMP.EM.RF-K3.F. Bilateral Comparison of horn antenna gain

CENTRE OF TESTING SERVICE INTERNATIONAL

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. TOKIN EMC ENGINEERING CO., LTD Hanashimashinden, Tsukuba-shi, Ibaraki Japan

Test Laboratory No Accredited by CAI for Electromagnetic Compatibility, Electrical Safety and Electrical Cable Tests

Test report rev1.0

L.S. Compliance, Inc. W66 N220 Commerce Court Cedarburg, WI

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

Transcription:

Certificate of Calibration ISO/IEC 17025:2005 and ANSI/NCSL Z540.1-1994 Model Number Manufacturer Description Serial Number Customer Asset No. 11667A Keysight Technologies Inc DC-18 GHz power splitter, type N, 50 ohm Customer Date of Calibration 15 Jul 2015 Procedure STE-50114535-B.00.02 Temperature (23 ± 5) C Humidity (50 ± 30) %RH Location of Calibration Keysight Technologies Inc EMG Support Operation 10090 Foothills Blvd. Roseville CA 95747-7102 United States This certifies that the equipment has been calibrated using applicable Keysight Technologies procedures and in compliance with ISO/IEC 17025:2005 and ANSI/NCSL Z540.1-1994 (R2002). The quality management system is registered to ISO 9001:2008. As Received Conditions The measured values of the equipment were observed IN SPECIFICATION at the points tested. Action Taken - No corrective actions were necessary. As Completed Conditions The measured values of the equipment were observed IN SPECIFICATION at the points tested. Remarks or Special Requirements This calibration certificate may reference instruments manufactured by HP, Agilent and Keysight as being manufactured by Keysight Technologies, Inc. The test limits stated in the report correspond to the published specifications of the equipment, at the points tested. Based on the customer's request, the next calibration is due on 15 Jul 2016. Keysight Technologies Inc EMG Support Operation 10090 Foothills Blvd. Roseville CA 95747-7102 United States Wes Fischbach Roseville Serv. Cntr. Mgr. Issue Date 16 Jul 2015 Page 1 of 11

Certificate of Calibration ISO/IEC 17025:2005 and ANSI/NCSL Z540.1-1994 Traceability Information Technician ID Number 00006447 Measurements are traceable to the International System of Units (SI) via national metrology institutes (e.g., NIST, NPL, PTB, NMIJ, NRC, KRISS, SIRIM, etc.) that are signatories to the CIPM Mutual Recognition Arrangement. This certificate shall not be reproduced, except in full, without prior written approval of the laboratory. Calibration Equipment Used Model Number Model Description Equipment ID Cal Due Date 85054B Standard mechanical calibration kit, DC to 18 GHz, 85054B00161 27 Apr 2016 1-6784931891-1 type-n 909F Precision Coaxial Termination, DC to 18 GHz 909F55103 7 Jan 2016 1-6372854158-1 N5230C PNA-L network analyzer N5230C01146 9 Apr 2016 1-6752311899-1 Traceability Table Model Model Description Equipment ID Trace Value W,R 85054B Standard mechanical calibration kit, DC to 18 GHz, type-n 85054B00161 1-6784931891-1-ACLASS:AC-1498 Reflection Coefficient Transmission Coefficient W,R 909F Precision Coaxial Termination, DC to 18 GHz 909F55103 1-6372854158-1-A2LA:2079.01 Reflection Coefficient W,R N5230C PNA-L network analyzer N5230C01146 1-6752311899-1-ACLASS:AC-1498 Reflection Coefficient Transmission Coefficient Legend W - Working Standard The calibration equipment used for the calibration of the Model indicated on the first page of the Certificate of calibration. R - Reference Standard The Reference Standard (Accredited or NMI-calibrated ETE) used to provide traceability to the SI-Units for the calibration parameters listed. Page 2 of 11

Certificate of Calibration ISO/IEC 17025:2005 and ANSI/NCSL Z540.1-1994 Compliance with Specification In the assessment of compliance with specification, the uncertainty of measurement has been taken into account. If the uncertainty of measurement overlaps the specification limit (upper limit or lower limit), it is not possible to state compliance/non-compliance based on a 95% level of confidence. However, where a confidence level less than 95% is acceptable, a compliance/non-compliance statement may be possible. The status of compliance with the acceptance criteria is reported as: - Compliant with specification. * - Compliance with specification providing a lower level of confidence is acceptable. * - Non-compliance with specification providing a lower level of confidence is acceptable. - Not compliant with specification. Upper Limit Nominal Lower Limit Judgement Mark * * The diagram above shows the typical compliance status for measured values as defined by this service. The vertical bar (U) above and below each measurement value represents the uncertainty of measurement. As Received Conditions/As Completed Conditions A compilation for all performed tests of the status as received (before any adjustment/repair) and the status as completed (after any adjustment/repair) is reported on the first page of this report. The compliance with typical (non-warranted) specifications will not affect the status as received or the status as completed reported on the first page. The status summaries relate to the tested item only. A final decision about whether the item's performance actually satisfies requirements of the user can only be made by the user. Uncertainty of Measurement The uncertainty evaluation has been performed in accordance with ISO/IEC Guide 98-3:2008 (GUM). The reported expanded measurement uncertainty is the standard uncertainty multiplied by the coverage factor k=2 (for a normal distribution) or k=1.65 (for a uniform distribution), which corresponds to a coverage probability of approximately 95%. Where this is not the case, the distribution, coverage factor (k), effective degrees of freedom (veff) and coverage probability (p) are stated. Any quoted measurement uncertainty applies only to the measured value and does not imply anything regarding the long-term stability of the equipment. Page 3 of 11

Certificate of Calibration ISO/IEC 17025:2005 and ANSI/NCSL Z540.1-1994 Performance Test Results Summary Test Name INPUT REFL COEF PORT2 INSERTION LOSS PORT3 INSERTION LOSS PORT2 to PORT3 TRACKING EQUIVALENT SOURCE MATCH As Received Status DONE DONE Page 4 of 11

INPUT REFL COEF The PHASE(deg) column is the measured PHASE. The MAG column is the measured MAGNITUDE. The MAXIMUM column is the spec for MAGNITUDE. The UNCERT column is the uncertainty for MAGNITUDE. TEST COND PHASE MAG MAXIMUM UNCERT. 50 MHz 42.1 0.002 0.070 0.0041 100 MHz 38.4 0.003 0.070 0.0041 500 MHz 10.2 0.006 0.070 0.0042 1000 MHz 27.2 0.005 0.070 0.0042 1500 MHz 66.6 0.004 0.070 0.0043 2000 MHz 154.7 0.002 0.070 0.0044 2500 MHz 168.4 0.004 0.070 0.0048 3000 MHz 159.9 0.006 0.070 0.0049 3500 MHz 161.9 0.009 0.070 0.0063 4000 MHz 151.3 0.014 0.070 0.0064 4500 MHz 131.2 0.016 0.111 0.0065 5000 MHz 111 0.020 0.111 0.0066 5500 MHz 84.2 0.017 0.111 0.0066 6000 MHz 54.2 0.016 0.111 0.0067 6500 MHz 10.1 0.012 0.111 0.022 7000 MHz 44.1 0.016 0.111 0.022 7500 MHz 88.4 0.027 0.111 0.022 8000 MHz 119.7 0.040 0.111 0.023 8500 MHz 147.6 0.053 0.184 0.023 9000 MHz 176.5 0.063 0.184 0.023 9500 MHz 153.2 0.068 0.184 0.023 10000 MHz 121.7 0.063 0.184 0.023 10500 MHz 89.8 0.054 0.184 0.023 11000 MHz 57.7 0.050 0.184 0.023 11500 MHz 18.4 0.057 0.184 0.023 12000 MHz 24.4 0.071 0.184 0.023 12500 MHz 60.6 0.080 0.184 0.024 13000 MHz 89.4 0.090 0.184 0.024 13500 MHz 115.5 0.100 0.184 0.024 14000 MHz 145.4 0.105 0.184 0.024 14500 MHz 176.1 0.085 0.184 0.024 15000 MHz 164.6 0.054 0.184 0.024 15500 MHz 165.9 0.048 0.184 0.024 16000 MHz 143.7 0.057 0.184 0.024 16500 MHz 106.4 0.049 0.184 0.024 17000 MHz 88.4 0.041 0.184 0.024 17500 MHz 75.2 0.062 0.184 0.024 18000 MHz 44.9 0.094 0.184 0.025 The PHASE uncertainty is Arcsin(UNCERT/MAG) degree, except where MAG is less than UNCERT, in which case PHASE uncertainty is +/- 180 degree. Page 5 of 11

INPUT REFL COEF (cont.) PORT2 INSERTION LOSS DONE TEST COND PHASE MAG UNCERT. NO SPECS FOR THIS PARAMETER 50 MHz 3.6 6.04 db 0.04 db 100 MHz 7.1 6.04 db 0.04 db 500 MHz 35.3 6.06 db 0.058 db 1000 MHz 70.6 6.07 db 0.043 db 1500 MHz 105.7 6.08 db 0.043 db 2000 MHz 140.8 6.12 db 0.043 db 2500 MHz 175.9 6.14 db 0.067 db 3000 MHz 149.1 6.17 db 0.067 db 3500 MHz 114.2 6.18 db 0.078 db 4000 MHz 79.2 6.21 db 0.078 db 4500 MHz 44.2 6.21 db 0.078 db 5000 MHz 9.3 6.23 db 0.078 db 5500 MHz 25.7 6.24 db 0.078 db 6000 MHz 60.7 6.25 db 0.078 db 6500 MHz 95.7 6.28 db 0.21 db 7000 MHz 130.5 6.30 db 0.22 db 7500 MHz 165.4 6.31 db 0.22 db 8000 MHz 159.7 6.32 db 0.22 db 8500 MHz 124.8 6.32 db 0.24 db 9000 MHz 89.9 6.29 db 0.24 db 9500 MHz 54.8 6.26 db 0.24 db 10000 MHz 19.4 6.23 db 0.24 db 10500 MHz 16.1 6.25 db 0.24 db 11000 MHz 51.2 6.28 db 0.24 db 11500 MHz 86.2 6.28 db 0.24 db 12000 MHz 121.5 6.24 db 0.24 db 12500 MHz 157 6.21 db 0.24 db 13000 MHz 167.6 6.22 db 0.24 db 13500 MHz 132.3 6.21 db 0.24 db 14000 MHz 96.9 6.12 db 0.24 db 14500 MHz 60.6 6.03 db 0.24 db 15000 MHz 23.8 6.08 db 0.24 db 15500 MHz 12.1 6.24 db 0.25 db 16000 MHz 47.1 6.33 db 0.25 db 16500 MHz 82.7 6.27 db 0.25 db 17000 MHz 119.2 6.25 db 0.25 db 17500 MHz 155.7 6.39 db 0.25 db 18000 MHz 168.7 6.57 db 0.25 db Page 6 of 11

PORT3 INSERTION LOSS DONE TEST COND PHASE MAG UNCERT. NO SPECS FOR THIS PARAMETER 50 MHz 3.6 6.04 db 0.04 db 100 MHz 7.1 6.04 db 0.04 db 500 MHz 35.3 6.06 db 0.058 db 1000 MHz 70.6 6.07 db 0.043 db 1500 MHz 105.7 6.09 db 0.043 db 2000 MHz 140.8 6.12 db 0.043 db 2500 MHz 175.9 6.15 db 0.067 db 3000 MHz 149.1 6.18 db 0.067 db 3500 MHz 114.2 6.20 db 0.078 db 4000 MHz 79.3 6.22 db 0.078 db 4500 MHz 44.3 6.23 db 0.079 db 5000 MHz 9.4 6.24 db 0.078 db 5500 MHz 25.5 6.25 db 0.078 db 6000 MHz 60.5 6.27 db 0.078 db 6500 MHz 95.5 6.29 db 0.21 db 7000 MHz 130.3 6.32 db 0.22 db 7500 MHz 165.2 6.32 db 0.22 db 8000 MHz 159.9 6.33 db 0.22 db 8500 MHz 125.1 6.33 db 0.24 db 9000 MHz 90.1 6.31 db 0.24 db 9500 MHz 55 6.26 db 0.24 db 10000 MHz 19.6 6.24 db 0.24 db 10500 MHz 15.8 6.26 db 0.24 db 11000 MHz 51 6.30 db 0.24 db 11500 MHz 85.9 6.31 db 0.24 db 12000 MHz 121.1 6.26 db 0.24 db 12500 MHz 156.7 6.23 db 0.24 db 13000 MHz 167.9 6.24 db 0.24 db 13500 MHz 132.7 6.24 db 0.24 db 14000 MHz 97.3 6.14 db 0.24 db 14500 MHz 61 6.05 db 0.24 db 15000 MHz 24.2 6.11 db 0.25 db 15500 MHz 11.7 6.28 db 0.25 db 16000 MHz 46.7 6.38 db 0.25 db 16500 MHz 82.2 6.31 db 0.25 db 17000 MHz 118.6 6.29 db 0.25 db 17500 MHz 155.2 6.44 db 0.25 db 18000 MHz 169.3 6.63 db 0.26 db Page 7 of 11

PORT2 to PORT3 TRACKING PORT2 is the right hand port and PORT3 is the left hand port,as seen reading the model number label. The PHASE(deg) column is the measured PHASE. The MAG column is the measured MAGNITUDE. The MINIMUM and MAXIMUM columns are specs for MAGNITUDE. The UNCERT column is the uncertainty for MAGNITUDE. TEST COND PHASE MINIMUM MAG MAXIMUM UNCERT. 50 MHz 0 0.150 db 0.003 db 0.150 db 0.046 db 100 MHz 0 0.150 db 0.001 db 0.150 db 0.046 db 500 MHz 0 0.150 db 0.001 db 0.150 db 0.052 db 1000 MHz 0 0.150 db 0.003 db 0.150 db 0.047 db 1500 MHz 0 0.150 db 0.006 db 0.150 db 0.052 db 2000 MHz 0 0.150 db 0.005 db 0.150 db 0.051 db 2500 MHz 0.1 0.150 db 0.003 db 0.150 db 0.051 db 3000 MHz 0 0.150 db 0.005 db 0.150 db 0.058 db 3500 MHz 0 0.150 db 0.007 db 0.150 db 0.060 db 4000 MHz 0 0.150 db 0.003 db 0.150 db 0.057 db 4500 MHz 0 0.200 db 0.015 db 0.200 db 0.063 db 5000 MHz 0 0.200 db 0.001 db 0.200 db 0.065 db 5500 MHz 0 0.200 db 0.011 db 0.200 db 0.060 db 6000 MHz 0 0.200 db 0.003 db 0.200 db 0.066 db 6500 MHz 0.1 0.200 db 0.002 db 0.200 db 0.072 db 7000 MHz 0 0.200 db 0.005 db 0.200 db 0.068 db 7500 MHz 0 0.200 db 0.004 db 0.200 db 0.071 db 8000 MHz 0 0.200 db 0.005 db 0.200 db 0.080 db 8500 MHz 0 0.250 db 0.011 db 0.250 db 0.073 db 9000 MHz 0 0.250 db 0.005 db 0.250 db 0.071 db 9500 MHz 0 0.250 db 0.009 db 0.250 db 0.083 db 10000 MHz 0 0.250 db 0.017 db 0.250 db 0.080 db 10500 MHz 0 0.250 db 0.012 db 0.250 db 0.074 db 11000 MHz 0 0.250 db 0.017 db 0.250 db 0.086 db 11500 MHz 0.1 0.250 db 0.016 db 0.250 db 0.087 db 12000 MHz 0 0.250 db 0.026 db 0.250 db 0.076 db 12500 MHz 0 0.250 db 0.018 db 0.250 db 0.088 db 13000 MHz 0.1 0.250 db 0.027 db 0.250 db 0.090 db 13500 MHz 0 0.250 db 0.021 db 0.250 db 0.074 db 14000 MHz 0 0.250 db 0.030 db 0.250 db 0.079 db 14500 MHz 0.1 0.250 db 0.026 db 0.250 db 0.091 db 15000 MHz 0 0.250 db 0.018 db 0.250 db 0.088 db 15500 MHz 0.1 0.250 db 0.033 db 0.250 db 0.088 db 16000 MHz 0.1 0.250 db 0.035 db 0.250 db 0.10 db 16500 MHz 0.1 0.250 db 0.046 db 0.250 db 0.10 db 17000 MHz 0.1 0.250 db 0.044 db 0.250 db 0.098 db 17500 MHz 0.2 0.250 db 0.045 db 0.250 db 0.11 db 18000 MHz 0.2 0.250 db 0.040 db 0.250 db 0.13 db Page 8 of 11

PORT2 to PORT3 TRACKING (cont.) The PHASE uncertainty is Arcsin(Lin_Mu/Lin_Mag) degree, except where Lin_Mag is less than Lin_Mu, in which case PHASE uncertainty is +/- 180 degree. Lin_Mu & Lin_Mag are linear mode of UNCERT & MAG, which can be calculated by: Lin_Mag= 10^(MAG /20) Lin_Mu = 10^(UNCERT /20) EQUIVALENT SOURCE MATCH PORT2 is the right hand port and PORT3 is the left hand port,as seen reading the model number label. The PHASE(deg) column is the measured PHASE. The MAG column is the measured MAGNITUDE. The MAXIMUM column is the specs for MAGNITUDE. The UNCERT column is the uncertainty for MAGNITUDE. TEST COND PHASE MAG MAXIMUM UNCERT. PORT2 EQUIVALENT SOURCE MATCH: 50 MHz 86.6 0.001 0.048 0.0034 100 MHz 64.6 0.002 0.048 0.0035 500 MHz 35.2 0.004 0.048 0.0051 1000 MHz 6.3 0.005 0.048 0.0051 1500 MHz 28.7 0.006 0.048 0.0037 2000 MHz 80.5 0.006 0.048 0.0049 2500 MHz 143.8 0.010 0.048 0.0059 3000 MHz 177.6 0.015 0.048 0.0044 3500 MHz 149.1 0.021 0.048 0.0049 4000 MHz 121.5 0.026 0.048 0.0065 4500 MHz 92.7 0.028 0.091 0.0050 5000 MHz 64.9 0.030 0.091 0.0048 5500 MHz 29 0.029 0.091 0.0067 6000 MHz 10.5 0.029 0.091 0.0058 6500 MHz 54.3 0.030 0.091 0.0047 7000 MHz 94 0.037 0.091 0.0069 7500 MHz 128.2 0.044 0.091 0.0065 8000 MHz 159.4 0.050 0.091 0.0048 8500 MHz 173.8 0.055 0.142 0.0072 9000 MHz 144.5 0.054 0.142 0.0070 9500 MHz 114.6 0.051 0.142 0.0049 10000 MHz 81.7 0.045 0.142 0.0073 10500 MHz 42 0.041 0.142 0.0080 11000 MHz 0 0.039 0.142 0.0055 11500 MHz 38.7 0.045 0.142 0.0070 12000 MHz 70 0.050 0.142 0.0083 12500 MHz 96.2 0.052 0.142 0.0059 Page 9 of 11

EQUIVALENT SOURCE MATCH (cont.) TEST COND PHASE MAG MAXIMUM UNCERT. 13000 MHz 116.5 0.054 0.142 0.0069 13500 MHz 133.6 0.051 0.142 0.0086 14000 MHz 147.7 0.047 0.142 0.0066 14500 MHz 155.3 0.043 0.142 0.0066 15000 MHz 164.9 0.041 0.142 0.0097 15500 MHz 179.6 0.044 0.142 0.0088 16000 MHz 161.2 0.047 0.142 0.0061 16500 MHz 131 0.053 0.142 0.0097 17000 MHz 99.7 0.063 0.142 0.0099 17500 MHz 67.2 0.081 0.142 0.0068 18000 MHz 37.6 0.101 0.142 0.011 PORT3 EQUIVALENT SOURCE MATCH: 50 MHz 54.5 0.001 0.048 0.0033 100 MHz 51.3 0.002 0.048 0.0035 500 MHz 21.9 0.006 0.048 0.0051 1000 MHz 17.5 0.006 0.048 0.0052 1500 MHz 25.7 0.009 0.048 0.0038 2000 MHz 64.9 0.006 0.048 0.0049 2500 MHz 124.6 0.010 0.048 0.0060 3000 MHz 164.9 0.014 0.048 0.0044 3500 MHz 162.7 0.018 0.048 0.0050 4000 MHz 134.3 0.022 0.048 0.0064 4500 MHz 105.8 0.023 0.091 0.0051 5000 MHz 69.2 0.023 0.091 0.0048 5500 MHz 34.7 0.020 0.091 0.0066 6000 MHz 14.1 0.020 0.091 0.0058 6500 MHz 65.2 0.023 0.091 0.0047 7000 MHz 106.7 0.031 0.091 0.0069 7500 MHz 139 0.038 0.091 0.0066 8000 MHz 169 0.045 0.091 0.0048 8500 MHz 164 0.048 0.142 0.0071 9000 MHz 134.3 0.047 0.142 0.0071 9500 MHz 103.3 0.043 0.142 0.0048 10000 MHz 65 0.036 0.142 0.0073 10500 MHz 21.7 0.036 0.142 0.0081 11000 MHz 25.1 0.036 0.142 0.0056 11500 MHz 61.2 0.046 0.142 0.0069 12000 MHz 90.8 0.050 0.142 0.0084 12500 MHz 116.7 0.054 0.142 0.0059 13000 MHz 137.4 0.054 0.142 0.0070 13500 MHz 152.3 0.045 0.142 0.0087 14000 MHz 163.3 0.037 0.142 0.0067 14500 MHz 163.3 0.031 0.142 0.0067 15000 MHz 157.6 0.030 0.142 0.0097 15500 MHz 163.1 0.039 0.142 0.0088 16000 MHz 179.8 0.046 0.142 0.0059 16500 MHz 152.5 0.056 0.142 0.0098 17000 MHz 122.9 0.066 0.142 0.0099 17500 MHz 89.3 0.079 0.142 0.0065 Page 10 of 11

EQUIVALENT SOURCE MATCH (cont.) TEST COND PHASE MAG MAXIMUM UNCERT. 18000 MHz 57.3 0.097 0.142 0.011 The PHASE uncertainty is Arcsin(UNCERT/MAG) degree, except where MAG is less than UNCERT, in which case PHASE uncertainty is +/- 180 degree. Page 11 of 11