ISSN Vol.03,Issue.22 September-2014, Pages:

Similar documents
A SPWM CONTROLLED THREE-PHASE UPS FOR NONLINEAR LOADS

Implementation of Three Phase UPS system using Multi-Loop Fuzzy Logic Controller for Linear and Non-Linear Loads

ISSN Vol.04,Issue.07, June-2016, Pages:

TRANSFORMER LESS H6-BRIDGE CASCADED STATCOM WITH STAR CONFIGURATION FOR REAL AND REACTIVE POWER COMPENSATION

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

Kalman Filter Based Unified Power Quality Conditioner for Output Regulation

Design and Development of MPPT for Wind Electrical Power System under Variable Speed Generation Using Fuzzy Logic

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Buck-Boost Converter based Voltage Source Inverter using Space Vector Pulse Width Amplitude modulation Jeetesh Gupta 1 K.P.Singh 2

MODIFIED CONTROL STRATEGY OF CASCADED H- BRIDGE MULTILEVEL CONVERTER IN GRID CONNECTED WIND ENERGY SYSTEM

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

Harmonic Reduction in Five Level Inverter Based Dynamic Voltage Restorer

Fuzzy Controlled Capacitor Voltage Balancing Control for a Three Level Boost Converter

IJSTE - International Journal of Science Technology & Engineering Volume 2 Issue 12 June 2016 ISSN (online): X

ISSN Vol.03,Issue.07, August-2015, Pages:

IJCSIET--International Journal of Computer Science information and Engg., Technologies ISSN

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

Current Rebuilding Concept Applied to Boost CCM for PF Correction

@IJMTER-2016, All rights Reserved 241

THREE PHASE UNINTERRUPTIBLE POWER SUPPLY BASED ON TRANS Z SOURCE INVERTER

Voltage Sag and Swell Mitigation Using Dynamic Voltage Restore (DVR)

Mitigating Voltage Sag Using Dynamic Voltage Restorer

GRID CONNECTED HYBRID SYSTEM WITH SEPIC CONVERTER AND INVERTER FOR POWER QUALITY COMPENSATION

An Observer-Based Optimal Voltage Control Scheme for Three-Phase Three Level UPS Systems

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

A Predictive Control Strategy for Power Factor Correction

DYNAMIC VOLTAGE RESTORER (DVR) FOR VOLTAGE SAG COMPENSATION WITH FUZZY LOGIC CONTROLLER. Chennai, Tamilnadu, India. Chennai, Tamilnadu, India.

Improvement of Power Quality Using Hybrid Active Power Filter in Three- Phase Three- Wire System Applied to Induction Drive

Design of Shunt Active Power Filter by using An Advanced Current Control Strategy

Grid Connected Photovoltaic Micro Inverter System using Repetitive Current Control and MPPT for Full and Half Bridge Converters

UTILITY interactive inverters converting dc power sources

PI-VPI Based Current Control Strategy to Improve the Performance of Shunt Active Power Filter

Grid Current Compensator for Grid- Connected Distributed Generation under Nonlinear Loads by Using DQ-SRF Technique

MITIGATION OF VOLTAGE SAGS/SWELLS USING DYNAMIC VOLTAGE RESTORER (DVR)

DIGITAL SIMULATION OF MULTILEVEL INVERTER BASED STATCOM

ANALYSIS OF SYNCHRONOUS-REFERENCE-FRAME-BASED CONTROL METHOD FOR UPQC UNDER UNBALANCED AND DISTORTED LOAD CONDITIONS Salava Nagaraju* 1

Multiconverter Unified Power-Quality Conditioning System: MC-UPQC T.Charan Singh, L.Kishore, T.Sripal Reddy

Grid-Tied Interleaved Flyback Inverter for Photo Voltaic Application

Multilevel Inverter Based Statcom For Power System Load Balancing System

Hybrid Active Power Filters for Reactive Power Compensation with Adaptive DC-Link Voltage Control

Svpwm Technique to Eliminate Harmonics and Power Factor Improvement Using Hybrid Power Filter and By Using Dsp Tms 320lf2407

FFT Analysis of THD in Distribution System with Grid Connected RES

A Series-Connected Multilevel Inverter Topology for Squirrel-Cage Induction Motor Drive

ISSN Vol.03,Issue.42 November-2014, Pages:

RECENTLY, the harmonics current in a power grid can

Protection from Voltage Sags and Swells by Using FACTS Controller

WILEY CONTROL OF POWER INVERTERS IN RENEWABLE ENERGY AND SMART GRID INTEGRATION. Qing-Chang Zhong. Tomas Hornik IEEE PRESS

IJREAT International Journal of Research in Engineering & Advanced Technology, Volume 1, Issue 1, March, 2013 ISSN:

Voltage Quality Enhancement in an Isolated Power System through Series Compensator

ACTIVE POWER ELECTRONIC TRANSFORMER A STANDARD BUILDING BLOCK FOR SMART GRID

Z-SOURCE INVERTER BASED DVR FOR VOLTAGE SAG/SWELL MITIGATION

Design and Simulation of FPGA Based Digital Controller for Single Phase Boost PFC Converter

Simulation of Multi Converter Unified Power Quality Conditioner for Two Feeder Distribution System

Analysis of Hybrid Power Conditioner in Three-Phase Four-Wire Distribution Power Systems for Suppressing Harmonics and Neutral-Line Current

Bridgeless Cuk Power Factor Corrector with Regulated Output Voltage

An Improved T-Z Source Inverter for the Renewable Energy Application

Analysis, Modeling and Simulation of Dynamic Voltage Restorer (DVR)for Compensation of Voltage for sag-swell Disturbances

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

A DYNAMIC VOLTAGE RESTORER (DVR) BASED MITIGATION SCHEME FOR VOLTAGE SAG AND SWELL

Enhanced Performance of Multilevel Inverter Fed Induction Motor Drive

A Sliding Mode Controller for a Three Phase Induction Motor

Improvement of Voltage Profile using D- STATCOM Simulation under sag and swell condition

Literature Survey: Multilevel Voltage Source Inverter With Optimized Convention Of Bidirectional Switches

A LLC RESONANT CONVERTER WITH ZERO CROSSING NOISE FILTER

CHAPTER 4 PV-UPQC BASED HARMONICS REDUCTION IN POWER DISTRIBUTION SYSTEMS

Design and Simulation of DVR Used For Voltage Sag Mitigation at Distribution Side

SUPERCONDUCTING MAGNETIC ENERGY

Power Quality Improvement Using Cascaded Multilevel Statcom with Dc Voltage Control

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 03 Issue: 11 Nov p-issn:

International Journal of Emerging Researches in Engineering Science and Technology, Volume 1, Issue 2, December 14

Improving Passive Filter Compensation Performance With Active Techniques

I. INTRODUCTION A. GENERAL INTRODUCTION

Harmonics Reduction using 4-Leg Shunt Active Power Filters

Power Quality improvement of a three phase four wire system using UPQC

Hardware Implementation of SPWM Based Diode Clamped Multilevel Invertr

Digital Simulation and Analysis of Sliding Mode Controller for DC-DC Converter using Simulink

New Pulse Multiplication Technique Based on Six-Pulse Thyristor Converters for High-Power Applications

Australian Journal of Basic and Applied Sciences. Simulation and Analysis of Closed loop Control of Multilevel Inverter fed AC Drives

Indirect Current Control of LCL Based Shunt Active Power Filter

AN EFFICIENT CLOSED LOOP CONTROLLED BRIDGELESS CUK RECTIFIER FOR PFC APPLICATIONS

Comparison of Reference Current Extraction Methods for Shunt Active Power Filters

A Modular Single-Phase Power-Factor-Correction Scheme With a Harmonic Filtering Function

Mitigation of Power Quality Problems Using DVR in Distribution Network for Welding Load

Mitigation of Voltage Sag/Swell Using UPQC

Single Phase Bidirectional PWM Converter for Microgrid System

Single Phase Induction Motor Drive using Modified SEPIC Converter and Three Phase Inverter

Ripple Reduction Using Seven-Level Shunt Active Power Filter for High-Power Drives

Power Quality Improvement with Renewable Sources for Non-Linear Load with PI and Fuzzy Controller

DESIGN OF A HYBRID ACTIVE FILTER FOR HARMONICS SUPPRESSION WITH VARIABLE CONDUCTANCE IN INDUSTRIAL POWER SYSTEMS USING FUZZY

Comparative Evaluation of Three Phase Three Level Neutral Point Clamped Z-Source Inverters using Advanced PWM Control Strategies

Pulse Width Modulator for Voltage Regulation in Voltage Source Inverter

IMPROVING EFFICIENCY OF ACTIVE POWER FILTER FOR RENEWABLE POWER GENERATION SYSTEMS BY USING PREDICTIVE CONTROL METHOD AND FUZZY LOGIC CONTROL METHOD

Simulation Of A Three Level Boosting PFC With Sensorless Capacitor Voltage Balancing Control

Multiple PR Current Regulator based Dead-time Effects Compensation for Grid-forming Single-Phase Inverter

Assessment of Different Compensation Strategies in Hybrid Active Power Filters

LOAD REACTIVE POWER COMPENSATION BY USING SERIES INVERTER OF UPQC

A Three-Phase AC-AC Buck-Boost Converter using Impedance Network

Transcription:

www.semargroup.org, www.ijsetr.com ISSN 2319-8885 Vol.03,Issue.22 September-2014, Pages:4466-4470 A High-Performance SPWM Controller for Three-Phase UPS Systems High Nonlinear Loads M.BHAVYA SREE 1, J.A.BASKAR 2 1 PG Scholar, Dept of ECE, NEC, Gudur, Nellore(Dt), AP, India, E-mail: bhavyasree304@gmail.com. 2 Associate Professor, Dept of ECE, NEC, Gudur, Nellore(Dt), AP, India, E-mail: baskar.sunny@gmail.com. Abstract: This paper presents the design of a high-performance SPWM which stands for sinusoidal pulse width modulation controller for three phase uninterruptible power supply (UPS) systems that are operating under highly nonlinear loads. This SPWM method is not good enough in compensating the harmonics and the distortion caused specifically by the nonlinear currents drawn by the rectifier loads. This study proposes a new design strategy that overcomes the limitations of the classical RMS control. It adds inner loops to the closed-loop control system effectively that enables successful reduction of harmonics and compensation of distortion at the outputs. The simulations are done in the MATLAB/ SIMULINK environment using the Simulink and PLECS model of the inverter. The results are evaluated based on steady-state error, transient response, and the THD of the output voltage. A THD equal to 0.89% at the output voltage is achieved even under the worst nonlinear load. Keywords: SPWM, UPS, MATLAB, Simulink. I. INTRODUCTION In the modern world, electricity has an indispensable role with its ability to combine power and intelligence. Most of the systems which are located in critical points in daily life need electricity to operate. The electrical energy increases productivity, efficiency, and allows a high degree of safety, reliability, and comfort of life. Contingency in the electric power line cannot be accepted critical areas involving safety, security, continuous industrial processes, data protection in information technologies. Although in the past backup generators were satisfactory to get power in case of interruption in the utility, long delay of generator starting and switching in today is not acceptable. Such delays badly affect critical loads such as computers, internet providers, telecom service providers, etc. as the power interruption causes data loss, process failure, and the cost for recovery becomes unacceptable. Even though the electric utility industry has made great effort for uninterrupted power line and undistorted line voltage, inevitably still there exist problems such as distortions, sag, swell, and spikes. In order to avoid such problems, uninterruptible power supply (UPS) systems [2]-[5], [7]-[36] with continuous and clean output power are utilized by compensating the harmonics and distortions caused by specifically nonlinear loads by implementing certain suitable and efficient control techniques. In this paper, output voltage control of a UPS with a zigzag connected transformer is investigated. Although there exist many papers on the output voltage control of UPS, minority of them involve the transformer based UPS. Due to the difficulty in modeling the zigzag transformer and uncertainty in the parameters of transformer, model based control algorithms which are the methods discussed in most papers, are not directly applicable to the transformer based UPS. Thus, instead of model based control structures, self converging feedback control structures are investigated. Among various control techniques, synchronous reference frame control (SRFC), resonant filter type control (RFC), and repetitive control (RC) are found suitable for application to the transformer UPS. However, due to the complexity of the above techniques, only the multi-loop high-performance SPWM control strategy method is considered suitable for the low cost (in terms of control, measurement etc. cost) and/or high power UPS systems. Therefore, the multi-loop high performance SPWM and its application to the three-phase transformer based UPS system will be the main focus of this paper. The aim of the paper is to establish in depth background on the multi-loop control method and apply the knowledge to systematically design the output voltage controller of the three-phase transformer based UPS. With the design issues well understood and a proper design completed, the performance of such a system will be investigated in detail with linear and non linear loads to evaluate the feasibility of this technology. To combine multi-loop controller with an advanced controller to control the output voltage to obtain THD levels much less thereby improving the quality of output delivered to the load. Therefore, the main contribution of this thesis is towards high performance Copyright @ 2014 SEMAR GROUPS TECHNICAL SOCIETY. All rights reserved.

multi-loop controller design and detailed performance investigation of a three-phase transformer based UPS system as shown in Fig.2. The stationary or synchronous-frame space-vector PWM (SVPWM)-based controllers are the primary choice of many researchers and the applications currently used in industry, today. However, the classical sinusoidal PWM (SPWM) method is still preferred by many manufacturers because of its implementation simplicity, easy tuning even under load, flexibility, and most importantly the advantages of controlling each phase independently and block diagram as shown in Fig.1. The independent regulation of each phase provides easy balancing of three-phase voltages which makes heavily unbalanced loading possible. Also, it avoids problems such as transformer saturation. Although the classical SPWM method is quite effective in controlling the RMS magnitude of the UPS output voltages, it is not good enough in compensating the harmonics and the distortion caused specifically by the nonlinear loads.for example, the total harmonic distortion (THD) is greater than 5% limit even with good filtering. It becomes more severe at high-power UPSs where the switching frequency has to be reduced due to the efficiency and heating problems. This study proposes a multi-loop high-performance SPWM control strategy and a design that overcome the limitations of the classical RMS control. It adds inner loops to the closed loop feedback control system effectively that enables successful reduction of harmonics and compensation of distortion at the voltages. The simulation results using the proposed controller achieves THD less than 3.0% under the nonlinear load having a crest factor of 3 and absorbing power equal to the rated power of the UPS. However, the significance of the proposed multiloop controller compared to other methods is as follows: The execution time is less and allows higher switching frequencies. The complex control algorithms take longer execution times and may limit the upper boundary of the switching frequency where you have actually some allowance for higher switching frequency operation [36]. Examples to the complex controllers are the repetitive, predictive, and harmonic droop controllers. The cost is low. Some control algorithms require precise floating point calculations either because they depend on a precise model or they use frequency-dependent sensitive controller gains. In brief, the precision dictates use of high-performance floating point expensive microcontrollers. The current implementation of the proposed controller is using fuzzy logic controller. The easy tuning even under load: Some are robust to this kind of tuning and some may not. This feature is preferred by some manufacturers. The easy tuning of the proposed method under load can be done with this method. The flexibility: It means that you can modify your controller and optimize it according to the customer specifications at the time of installation or later in use. The optimization may include obtaining the lowest THD or the best tracking of the RMS value or the fastest M.BHAVYA SREE, J.A.BASKAR dynamic response. So, the controller should be flexible anytime to do any of the aforementioned optimizations without significantly affecting the others. We have also verified this feature experimentally. The scalability: It means that the controller is easy to design and tunable for any power level. Accordingly, this paper favors the proposed multi-loop controller using fuzzy logic controller and presents the work according to the following arrangement. Section II provides a short description of a typical three phase UPS system. Fig.1. Block diagram. Fig.2. Single-line diagram of a typical three-phase fourwire transformer isolated UPS system. Fig.3. PLECS model of the designed inverter power stage including delta zigzag transformer, the LC filter, the measurements, and the linear and nonlinear loads.

A High-Performance SPWM Controller for Three-Phase UPS Systems High Nonlinear Loads II. SIMULATION RESULTS The simulink model of the proposed multi-loop controller is built in Matlab simulation environment and performance is evaluated based on the RMS voltage and Total harmonic distortion (THD).The inverter power stage being heart of the UPS is being designed as sub circuit of the UPS and the state space model of the inverter that constitutes for stability is also designed and the control diagram is designed such that it is in line with the state space model of the inverter power stage of UPS. loading conditions: nonlinear full load, linear full load, and no load. The lower trace shows the total output apparent power delivered into these loads. The test was set up to supply each load approximately over a one-min interval. As shown in the lower trace of Fig.10, the UPS was initially loaded with the rated single-phase rectifier load, then no load, 1 min later a resistive load at 8.5 kw, and finally the same rectifier load is applied again in Fig.11. III. EXPERIMENTAL RESULTS A UPS system rated at 10 kva, 50 Hz, 380 V was built and tested to evaluate the performance of the controller and the design. The implemented system uses the component values given in the PLECS simulation model of the converter shown in Fig.3 for the inverter part and the values given in Fig.2 for the controller part. In Fig.2, we compare the results of the multiloop design against the single-loop (only the RMS control) design in order to demonstrate the performance of the proposed multiloop controller. Fig.4 compares the measured three-phase output voltages and the current of one phase for two loading conditions: the linear full load and the nonlinear full load. Fig.5 show the results when only the RMS control is used (single-loop), for this case the control achieves 1.96% THD for the linear and 9.68% THD for the nonlinear load. It is clear that the RMS control alone cannot achieve an acceptable THD under nonlinear loading at the rated UPS output power. Fig.5. Three phase voltage under Linear loads. Fig.6. Three phase voltage under non Linear loads. Fig.4. Simulation circuit of Three phase UPS with ulti loop SPWM controller. The waveforms in Fig.6 show the results when the proposed multiloop controller is used for the same loading conditions. In this case, the controller achieves 1.11% THD for the linear load and 3.8% THD for the nonlinear load. The crest factor of the current in Fig.7 is measured as 2.8. The THD measurements given previously and also shown in Fig.8 were taken by the 3196 HIOKI power quality analyzer. The upper trace in Fig.9 shows the profile of the % THD of the output voltage of one phase versus the three different Fig.7. Three phase line current under linear loads.

M.BHAVYA SREE, J.A.BASKAR Fig.8. Three phase line current under non linear loads. Fig.11. THD Analysis whose value is 2.85%. IV. CONCLUSION This paper presents the analysis and design of a high performance SPWM controller for three-phase UPS systems powering highly nonlinear loads. Although the classical SPWM method is very successful in controlling the RMS magnitude of the UPS output voltages, it cannot effectively compensate for the harmonics and the distortion caused by the nonlinear currents drawn by the rectifier loads. Fig.9. RMS load voltage for linear loads. Fig.10. RMS load voltage for non linear loads. V. REFERENCES [1] Uninterruptible power systems (UPS) Part 3: Method of specifying the performance and test requirements, First Edition 1999-03, International Standard IEC 62040-3. [2] F. Botter on and H. Pinheiro, A three-phase UPS that complies with the standard IEC 62040-3, IEEE Trans. Ind. Electron., vol. 54, no. 4, pp. 2120 2136, Aug. 2007. [3] Q.-C. Zhong and Y. Zeng, Can the output impedance of an inverter be designed capacitive? in Proc. 37th Annu. IEEE Conf. Ind. Electron.,2011, pp. 1220 1225. [4] U. Borup, P. N. Enjeti, and F. Blaabjerg, A new spacevector-based control method for UPS systems powering nonlinear and unbalanced loads, IEEE Trans. Industry Appl., vol. 37, no. 6, pp. 1864 1870,Nov./Dec. 2001. [5] Q.-C. Zhong, F. Blaabjerg, J. Guerrero, and T. Hornik, Reduction of voltage harmonics for parallel-operated inverters equipped with a robust droop controller, in Proc. IEEE Energy Convers. Congr. Expo.,Phoenix,AZ, 2011, pp. 473 478. [6] S. Jiang, D. Cao, Y. Li, J. Liu, and F. Z. Peng, Low THD, fast transient,and cost-effective synchronous-frame repetitive controller for three-phase UPS inverters, IEEE Trans. Power Electron., vol. 27, no. 6, pp. 2294 3005, 2012. [7] P.Mattavelli, Synchronous-frame harmonic control for high-performance AC power supplies, IEEE Trans. Ind. Appl., vol. 37, no. 3, pp. 864 872, May/Jun. 2001. [8] N. M. Abdel-Rahim and J. E. Quaicoe, Analysis and design of a multiple feedback loop control strategy for single-phase voltage-source UPS inverters, IEEE Trans. Power Electron., vol. 11, no. 4, pp. 532 541, Jul.1996.

A High-Performance SPWM Controller for Three-Phase UPS Systems High Nonlinear Loads [9] M. J. Ryan, W. E. Brumsickle, and R. D. Lorenz, Control topology options for single-phase UPS inverters, IEEE Trans. Ind. Appl., vol. 33,no. 2, pp. 493 501, Mar./Apr. 1997. [10] F. Botter on, H. Pinheiro, H. A. Grundling, and J. R. P. H. L. Hey, Digital voltage and current controllers for threephase PWM inverter for UPS applications, in Proc. 36th Annu. Meeting IEEE Ind. Appl., Chicago, IL, Sep./Oct. 2001, vol. 4, pp. 2667 2674. [11] P. C. Loh, M. J. Newman, D. N. Zmood, and D. G. Holmes, A comparative analysis of multiloop voltage regulation strategies for single and three-phase UPS systems, IEEE Trans. Power Electron., vol. 18, no. 5,pp. 1176 1185, Sep. 2003. [12] E. Kim, J. Kwon, J. Park, and B. Kwon, Practical control implementation of a three-to single-phase online UPS, IEEE Trans. Ind. Electron., vol. 55,no. 8, pp. 2933 2942, Aug. 2008. [13] T. Kawabata, T. Miyashita, and Y. Yamamoto, Dead beat control of three phase PWM inverter, IEEE Trans. Power Electron., vol. 5, no. 1, pp. 21 28, Jan. 1990. [14] Y.-Y. Tzou, R.-S. Ou, S.-L. Jung, and M.-Y. Chang, High-performance programmable AC power source with low harmonic distortion using DSPbased repetitive control technique, IEEE Trans. Power Electron., vol. 12, no. 4, pp. 715 725, Jul. 1997. [15] C. Rech, H. Pinheiro, H. A. Grundling, H. L. Hey, and J. R. Pinheiro, Analysis and design of a repetitive predictive-pid controller for PWM inverters, in Proc. IEEE 32nd Power Electron. Spec. Conf., Vancouver, BC, Canada, 2001, vol. 2, pp. 986 991. [16] K. Zhang, Y. Kang, J. Xiong, and J. Chen, Direct repetitive control of SPWM inverter for UPS purpose, IEEE Trans. Power Electron., vol. 18, no. 3, pp. 784 792, May 2003.