User s Guide HX71 SERIES. RH Probe/Transmitter. Shop online at omega.com SM. RoHS 2 Compliant

Similar documents
User s Guide HX94B SERIES. Temperature/Relative Humidity Transmitter. Shop online at omega.com SM

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA Of Course! Shop online at omega.com SM

User s Guide EWS-BP-A. Barometric Pressure Transmitter. Shop online at omega.com

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA Of Course!

User s Guide HX93B SERIES. Temperature/Relative Humidity Transmitters. Shop online at omega.com

User s Guide EWS-RH. Relative Humidity/Temperature Transmitter. Shop online at. omega.com

User s Guide CL309A Milliamp Loop Calibrator. Shop online at omega.com SM

User s Guide TX92A. Miniature Temperature Transmitters. Shop online at omega.com

User s Guide TX94A. Ultra-Miniature Temperature Transmitters. Shop online at omega.com

User s Guide FLSC-45/45B. Paddlewheel Signal Conditioner. Shop online at omega.com

User s Guide TX91A. (J, K, T, E) 4-20 ma Mini Temperature Transmitter. Shop online at omega.com

User s Guide TX93A. (J, K, T, E) 4-20 ma Ultra-Miniature Temperature Transmitters. Shop online at omega.com

User s Guide. PCL1000 Multi-Function Calibrator. Shop online at omega.com. For latest product manuals:

User s Guide. TX94 RTD Temperature Transmitter. Shop online at. omega.com For latest product manuals: omegamanual.

User s Guide TX94A-SS. Stainless Steel RTD Temperature Transmitter. Shop online at

User s Guide EWS-RH. Relative Humidity/Temperature Transmitter. Shop online at. MADE IN

User s Guide. HX92A Series RELATIVE HUMIDITY TRANSMITTER. Shop online at. MADE IN

User s Guide HX92A SERIES RELATIVE HUMIDITY TRANSMITTER. Shop online at omega.com For latest product manuals: omegamanual.

SPRTX SERIES. General Description. Unpacking

User s Guide CL3515R. K/J/T/E/R/S/N/L/U/B/C Calibrator Thermometer. Shop online at omega.com SM

User s Guide. TX905 Field Rangeable Voltage Input Two-Wire Transmitter. Shop online at

User s Guide TX93. Thermocouple Two-Wire Temperature Transmitter. Shop online at

User s Guide OS136A SERIES. Miniature Low-Cost Non-Contact Infrared Temperature Sensor/Transmitter. Shop online at omega.com

User s Guide HX93A, HX93DA SERIES. RH/Temperature Transmitter. Shop online at. MADE IN

OMEGA. EWSE Series. Rugged, Weatherproof Temperature Sensors and Transmitters. 1.0 Description. 2.0 Receiving and Unpacking

User s Guide. Series. Ultra High Performance 2-Color Fiber Optic Infrared Ratio Temperature Measurement & Control System. Shop online at omega.

User s Guide UWPC-2-NEMA. Wireless Process Voltage/Current Transmitter. Shop online at omega.com SM

User s Guide. DMD-476-DC Bridgesensor DC Powered Signal Conditioner

User s Guide. OS301A-USB Series OS150A-2USB Series. Infrared Temperature Sensors. Shop online at omega.com

User s Guide CCT-80. Strain Gage Signal Conditioners. M2218/1201

CCT-22, CCT-23, CCT-24, CCT-25, CCT-26, CCT-27

User s Guide UWPC-2A-NEMA-M12. Weather Resistant Wireless Process Voltage/Current Transmitter. Shop online at omega.com SM

HUMITRAN-RHT & RH RELATIVE HUMIDITY/TEMPERATURE TRANSMITTER RELATIVE HUMIDITY TRANSMITTER

OMEGA. HHM598C Digital Clamp-On Meter

User s Guide UWPH-2-NEMA. Wireless ph/temperature Transmitter. Shop online at omega.com SM

User s Guide. DMD-465 Bridgesensor AC Powered Signal Conditioner

User s Guide DRF-POT FOR POTENTIOMETER INPUT, DRF-RES FOR RESISTANCE INPUT. DRF Series Signal Conditioners. Shop online at

User s Guide OS136 SERIES. Miniature Low-Cost Non-Contact Infrared Temperature Sensor/Transmitter

User s Guide CL514-PLUS. Automated Universal RTD Calibrator. Shop online at

User s Guide JBOX Summing Box/Transmitter. Shop online at. omega.com For latest product manuals: omegamanual.

User s Guide DRF-VDC FOR DC VOLTAGE INPUT DRF-VAC FOR AC VOLTAGE INPUT. DRF Series Signal Conditioners. Shop online at

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA Of Course!

User s Guide CL535. Frequency Calibrator with Totalizer. Shop online at. omega.com For latest product manuals: omegamanual.

User s Guide. LDX-CA LDX-CA card. An OMEGA Technologies Company. LDX-CA M /05 Page 1 of 16

User s Guide LDX-4. Shop online at omega.com. For latest product manuals:

User s Guide DRF-FR FOR FREQUENCY INPUT. DRF Series Signal Conditioners. Shop online at

OMEGA. HHM596C Digital Clamp-On Meter

OMEGA. HHM599 Digital Trms Clamp-On Meter

OMEGA. HHM23 Digital Multimeter

OMEGA. HHM31 Digital Multimeter

User's Guide FMG-1000-DLA. Shop online at. Data Logger. omega.com For latest product manuals: omegamanual.

User s Guide OS950 SERIES. Handheld Infrared Thermometers. Shop online at. omega.com.

OMEGA. HHM63 Digital Multimeter

User's Guide FMG210/220 SERIES. Shop online at. Low Flow Magnetic Flow Meter

LDP6-CDC. Serial Communications Option Card M

User s Guide UWTC-2A-NEMA. Weather Resistant Temperature-to-Wireless Transmitter for Thermocouples. Shop online at omega.com

User s Guide DRST-FR. Programmable Converter. Shop online at omega.com. For latest product manuals:

OMEGA. HHM27 Digital Multimeter

User s Guide Shop online at omega.com For latest product manuals: omegamanual.info

User s Guide CL510A. RTD Simulator. Shop online at. omega.com. For latest product manuals: omegamanual.info CL510A-1 CL510A-10

User s Guide CL427. Documenting Multifunction Calibrator and Arbitrary Function Generator

RHS SERIES RH Set Point Controller/Probe

User s Guide. R2 Ultra High Performance 2-Color Fiber Optic Infrared Ratio Temperature Measurement & Control System USA.

PXTX-507. NEWPORT Electronics, Inc. STRAIN/BRIDGE INPUT 2-WIRE TRANSMITTER WITH 4-20 ma OUTPUT. Instruction Manual

User s Guide. Shop online at OME-DB-889D. 16-Channel Analog Multiplexer Board

User s Guide UWXL-24-PC. Long Distance Industrial Wireless Process Voltage and Current Input Transmitter. Shop online at omega.com

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

TRANSDUCER IN-LINE AMPLIFIER

User s Guide HE-XT Digital DC Inputs, 12 Digital DC Outputs, 2 Analog Inputs Including T/C & RTD (High Resolution), 2 Analog Outputs

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

FOH201 User manual 1

User s Guide FMG200SERIES. Shop online at. omega.com For latest product manuals: omegamanual.info

User s Guide HE-XE Digital DC Inputs, 12 Digital DC Outputs, 2 Analog Inputs Including T/C & RTD (High Resolution), 2 Analog Outputs

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

AC-TX Volt/100 Volt Transformer Panel for VR61 and VR62 Loudspeakers and the CLA37 Column Loudspeaker AC-TX128

User s Guide HHM-EX830. True RMS 1000 Amp Clamp Meter with IR Thermometer

User s Guide. LD610 Series B.I.C.M. Displacement Transducers With In-Line Signal Conditioners. Shop online at

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA... Of Course!

TRANSDUCER IN-LINE AMPLIFIER

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

Instruction Manual. HB Series Mini Level Sensor

Instruction Manual Inductive Gauging Sensor

VT1586A Rack Mount Terminal Panel Installation and User s Manual

Ultra Precise Immersion RTD Sensors

Soil Moisture Smart Sensors (S-SMx-M005)

User s Guide ZW-ED. zwseries Wireless End Device. Shop online at omega.com. For latest product manuals:

User s Manual. Ground Resistance Clamp On Tester MODEL

ELECTROSURGICAL UNIT ANALYZER

LT3000 ULTRASONIC LEVEL TRANSMITTER

User s Guide UWXL-24-PH. Long Distance Industrial Wireless ph Transmitters. Shop online at omega.com

TAG5000 WIRELESS PHASER. Instruction Manual HD ELECTRIC COMPANY 1475 LAKESIDE DRIVE WAUKEGAN, ILLINOIS U.S.A.

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

User s Guide DRLP SERIES. Isolated DIN Rail Mount 2-Wire Trasmitters. Shop online at omega.com

EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure

VideoEase VGA 1x4 Distribution Hub (500150, ) Installation Guide

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

80i-600A AC Current Probe

Table of Contents. Safety Notices

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

Transcription:

RoHS 2 Compliant User s Guide HX71-NB MODEL Shop online at omega.com SM e-mail: info@omega.com For latest product manuals: www.omegamanual.info HX71 MODEL HX71 SERIES RH Probe/Transmitter

omega.com info@omega.com Servicing North America: U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047 Stamford, CT 06907-0047 USA Toll-Free: 1-800-826-6342 (USA & Canada only) Customer Service: 1-800-622-2378 (USA & Canada only) Engineering Service: 1-800-872-9436 (USA & Canada only) Tel: (203) 359-1660 Fax: (203) 359-7700 e-mail: info@omega.com For Other Locations Visit omega.com/worldwide The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.

HX71 SERIES RH Probe/Transmitter TABLE OF CONTENTS Section Page 1. General Description... 1 2. Unpacking... 1 3. Theory of Operation... 2 4. Installation and Mounting... 3-4 5. Electrical Connections... 5 6. Wiring Examples... 6 7. Relative Humidity Output Calculations... 6 8. RH Measured Vs Output Reading Table... 7 9. Calibration and Maintenance... 8 10. Specifications... 9 i

FIGURES HX71 SERIES RH Probe/Transmitter Figure Figure 1 Page Basic Transmitter Set-up With Current Loop Output... 2 Figure 2 HX71 Dimensions... 3 Figure 3 HX71 Mounting... 3 Figure 4 HX71-NB Dimensions and Mounting... 4 Figure 5 Figure 6 Current Transmitter Wiring Example (4-20 ma)... 6 Voltage Transmitter Wiring Example (0-1 Vdc and 0-5 Vdc)... 6 ii

General Description 1 1. General Description The OMEGA HX71 Series Relative Humidity Transmitter s provide a linearized and temperature compensated output signal of 4 to 20 ma, 0 to 1 Vdc or 0 to 5 Vdc depending upon the model selected. The output signal has been calibrated and scaled 0 to 100% for Relative Humidity. A thin film polymer capacitor senses relative humidity and is protected by a stainless steel cap that is easily removed for cleaning. The Nema-4 stainless steel enclosure and cable entry connection provides weathertight protection. 2. Unpacking Remove the packing list and verify that you have received all your equipment. If you have any questions about the shipment, please call our Customer Service Department at: 1-800-622-2378 or 203-359-1660. On the web you can find us at: omega.com e-mail: cservice@omega.com When you receive the shipment, inspect the container and equipment for any signs of damage. Note any evidence of rough handling in transit. Immediately report any damage to the shipping agent. NOTE The carrier will not honor any damage claims unless all shipping material is saved for inspection. After examining and removing contents, save packing material and carton in the event reshipment is necessary. The following items are supplied in the box with your HX71 transmitter. This Manual, # M-4543 (1 ea.) Dewpoint Card (1 ea.) Recommended Power Supply For HX71-MA and HX71-MA-NB, Omega Model PST-10 For HX71-V1, HX71-V2, HX71-V1-NB and HX71-V2-NB: Omega Model FPW-15 Complimentary Instruments iseries Panel Meters and Controllers Recommended Accessories Duct/Wall Mounting Kit, OMEGA Part No.: IND-KIT (For HX71- MA, HX71-V1, HX71-V2) Transmitter Cable, OMEGA Part No.: TX4-100 (100 ft) RH Calibration Kit, OMEGA Part No.: HX92-CAL 1

3 Theory of Operation 3. Theory of Operation A 4-20 ma loop is a series loop in which a transmitter will vary the current flow depending on the input to the transmitter. In the HX71 Series the amount of current allowed to flow in the loop will vary depending on the relative humidity or temperature being measured by the sensor(s). Some advantages of a current output over a voltage output is that the signal measured is less susceptible to electrical noise interference and the loop can support more than one measuring instrument as long as the maximum loop resistance is not exceeded. A typical application utilizing a current loop will normally consist of a power supply, the transmitter and a meter, recorder or controller to measure the current flow. The loop resistance in the sum of the measuring instruments and wire used. The maximum allowable loop resistance for the HX71 to function properly is found by using the following formula: R max = (power supply voltage 8 volts) 0.02 amps EXAMPLE: (When using a 10 Vdc power supply). R max = (10 8) 0.02 amps = 800 ohms max loop resistance PANEL METER + 50% HX71 CABLE BLACK WIRE RED WIRE SHIELD WIRE + 10V POWER SUPPLY Figure 1 - Basic Transmitter Set-up With Current Loop Output 2

Installation and Mounting 4 4. Installation and Mounting NOTE Your HX71 Series RH Probe/Transmitter needs to be installed in applications that allow for well circulated air flow to meet the published specifications outlined here in this manual in Section 10. OMEGA s HX71 transmitter s are designed for either wall or duct mounting. A wall/duct mounting kit is available, OMEGA Part No.:HX90DM-KIT. 131 (5.18) DIMENSIONS: mm (in) Ø 16 (5/16) Figure 1-3. - RH-USB Dimensions DUCT WALL MOUNTING GASKET MOUNTING PLATE MOUNTING SCREW MOUNTING BUSHING MOUNTING SCREW CLAMP HX71 MOUNTING NUT HX71 Figure 3 - HX71 Mounting 3

4 Installation and Mounting 19.5 (0.76) MOUNTING HOLE 4.3 (0.17) DIA. 45.3 (1.78) 38 (1.50) 50 (1.97) MOUNTING HOLE 4.3 (0.17) DIA. 52.6 (2.07) 65 (2.56) 16 (0.62) DIA. DIMENSIONS: mm (in) Figure 4 - HX71-NB Dimensions and Mounting 4

Electrical Connections 5 5. Electrical Connections CAUTION All electrical connections and wiring should be performed by a suitably trained professional only. Model: HX71-MA, HX71-MA-NB (2-Wire Current Output) Red Wire: + Power Supply Black Wire: 4-20 ma Output Bare Wire: Shield, Earth Ground Model: HX71-V1, HX71-V2, HX71-V1-NB, HX71-V2-NB (3-Wire Voltage Output) Red Wire: + Power Supply Black Wire: - Power/-Output Wire: + Output White Bare Wire: Shield, Earth Ground CAUTION Your HX71 Series RH Probe/Transmitter has not been designed for, nor is it recommended for, use in medical or nuclear applications. Your HX71 Series RH Probe/Transmitter should never be installed in or anywhere near explosive or flammable materials. 5

6 HX71 SERIES RH Probe/Transmitter 6. Wiring Examples Current output model HX71-MA, HX71-MA-NB (4 to 20 ma) PANEL METER + 50% HX71 CABLE BLACK WIRE RED WIRE SHIELD WIRE + 10V POWER SUPPLY PANEL METER Figure 5 - Current Transmitter Wiring Example Voltage output models HX71-V1, HX71-V2, HX71-V1-NB, HX71-V2- NB (0 to 1 Vdc or 0 to 5 Vdc) PANEL METER HX71 CABLE WHITE WIRE BLACK WIRE RED WIRE SHIELD WIRE + 50% + 24V POWER SUPPLY Figure 6 - Voltage Transmitter Wiring Example 7. Relative Humidity Output Calculations To calculate % Relative Humidity by measuring the current or voltage output use the following formulas. For 4-20 ma output: % RH = (Current measured in milliamps 4) 0.16 EXAMPLE: (11.04 ma 4) 0.16 = 44% RH For 0 to 1 Vdc output: % RH = (Voltage measured in volts x 100) EXAMPLE: 0.44 Vdc x 100 = 44% RH 6

RH Measured Vs Output Reading Table 8 8. RH Measured Vs Output Reading Table % Relative Output Humidity 4-20 ma 0-1 (0-5) Vdc 5 4.8 0.05 (.25) 10 5.6 0.10 (.50) 15 6.4 0.15 (.75) 20 7.2 0.20 (1.00) 25 8.0 0.25 (1.25) 30 8.8 0.30 (1.50) 35 9.6 0.35 (1.75) 40 10.4 0.40 (2.00) 45 11.2 0.45 (2.25) 50 12.0 0.50 (2.50) 55 12.8 0.55 (2.75) 60 13.6 0.60 (3.00) 65 14.4 0.65 (3.25) 70 15.2 0.70 (3.50) 75 16.0 0.75 (3.75) 80 16.8 0.80 (4.00) 85 17.6 0.85 (4.25) 90 18.4 0.90 (4.50) 95 19.2 0.95 (4.75) 7

9 Calibration and Maintenance 9. Calibration and Maintenance Calibration Your transmitter has been factory calibrated to meet or exceed the specifications outlined in this manual. The economical design of the HX71 Series does not allow for field adjustment. Contact our Customer Service Department if you believe your unit is not functioning correctly. Maintenance If your Humidity transmitter will be used in a dusty environment, the protective sensor cover may be removed for cleaning. Unscrew the protective cover and gently blow compressed air through the cap. A soft brush may also be used to remove dirt particles. If the sensor is subjected to 100% condensation, it must be dried to obtain correct readings. There will be no permanent damage or calibration shift to the unit. Units should not be exposed to high concentrations of ammonia or alcohol vapors. 8

Specifications 10 10. Specifications Relative Humidity Measuring Range: 5-95% (non-condensing) Accuracy:* ±4%RH @ 22 C (72ºF) from 15 to 85% RH; ±4.5%RH @ 22 C (72ºF) below 15 and above 85% RH * EMC (Electro Magnetic Compatibility) Some of these devices may be subject to an additional reading error of up to 2% by RFI (Radio Frequency Interference) when subjected to a field strength of 3V/m between 625MHz and 725MHz. Repeatability: ± 1% RH Operating Temperature Range: -25 to 85ºC (-13 to 185ºF) Output Model HX71-MA, HX71-MA-NB: 4 to 20 ma (Scaled for 0 to 100% RH) Model HX71-V1, HX71-V1-NB: 0 to 5 Vdc (Scaled for 0 to 100% RH) Model HX71-V2, HX71-V2-NB: 0 to 1 Vdc (Scaled for 0 to 100% RH) Power Model HX71-MA, HX71-MA-NB: 8 12 Vdc @ 20mA Model HX71-V1, HX71-V2 HX71-V1-NB, HX71-V2-NB: 8 24 Vdc @ 20mA Max Loop Resistance: Sensor Type: Enclosure Housing Tube Version: Enclosure Version: Electrical Connections: Dimensions: Weight: Approvals: Ohms = (V supply 8 V)/0.02 A Thin Film Polymer Capacitor 316 Stainless Steel, NEMA 4 Polycarbonate, NEMA 4 2 m (6') 4-conductor shielded PVC cable with stripped wire leads. See Mounting Section 200 g (7 oz) 9

NOTES: HX71 SERIES RH Probe/Transmitter NOTES: 10

WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA s customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs. OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages. CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a Basic Component under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner. RETURN REQUESTS/INQUIRIES Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit. FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1. Purchase Order number under which the product was PURCHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA: 1. Purchase Order number to cover the COST of the repair, 2. Model and serial number of theproduct, and 3. Repair instructions and/or specific problems relative to the product. OMEGA s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. Copyright 2016 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA Of Course! Shop online at omega.com SM TEMPERATURE MU Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies MU Wire: Thermocouple, RTD & Thermistor MU Calibrators & Ice Point References MU Recorders, Controllers & Process Monitors MU Infrared Pyrometers PRESSURE, STRAIN AND FORCE MU Transducers & Strain Gages MU Load Cells & Pressure Gages MU Displacement Transducers MU Instrumentation & Accessories FLOW/LEVEL MU Rotameters, Gas Mass Flowmeters & Flow Computers MU Air Velocity Indicators MU Turbine/Paddlewheel Systems MU Totalizers & Batch Controllers ph/conductivity MU ph Electrodes, Testers & Accessories MU Benchtop/Laboratory Meters MU Controllers, Calibrators, Simulators & Pumps MU Industrial ph & Conductivity Equipment DATA ACQUISITION MU Data Acquisition & Engineering Software MU Communications-Based Acquisition Systems MU Plug-in Cards for Apple, IBM & Compatibles MU Data Logging Systems MU Recorders, Printers & Plotters HEATERS MU Heating Cable MU Cartridge & Strip Heaters MU Immersion & Band Heaters MU Flexible Heaters MU Laboratory Heaters ENVIRONMENTAL MONITORING AND CONTROL MU Metering & Control Instrumentation MU Refractometers MU Pumps & Tubing MU Air, Soil & Water Monitors MU Industrial Water & Wastewater Treatment MU ph, Conductivity & Dissolved Oxygen Instruments M4543/0116