KINAX WT 717 Programmable Transmitter for Angular Position

Similar documents
KINAX 2W2 Programmable Transmitter for Angular Position

KINAX SR 719 Programmable Transmitter for Position Feedback

KINAX WT 707 Transmitter for angular position

SINEAX TV809, 1 channel Programmable Isolating Amplifier

Plug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

Rudder or propeller angular position transmitter KINAX WT720

KINAX 3W2 Transmitter for angular position

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

SINEAX G 536 Phase Angle or Power Factor Transducer

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

SINEAX TI 807 Passive DC signal isolator

SINEAX B 811 Power Pack with additional Functions

SINEAX / EURAX 2I1 Passive DC signal isolator

Angular Position Engineering

SINEAX U 553 Transducer for AC Voltage

SINEAX I 552 Transducer for AC current

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

SINEAX V 604s Programmable multifunctional transmitter

Plug-in module SIRAX TI 807 Passive DC signal isolator

SINEAX G 537 Transducer for Phase Angle Difference

Angle position transmitter Type RT-2 Marine bridge instrumentation C (UK) Measuring output: DC current signal 0..20mA or 4..

EURAX UI 505, Combined Transducer for AC current and AC voltage

EMBSIN 281 G Power factor transducer

SINEAX VC 603, Programmable combined transmitter/alarm unit

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

SITRANS T measuring instruments for temperature

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

SINEAX V604s Programmable multifunctional transmitter

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

SALES SERVICE +358 (0)

for DC currents or voltages, temperature sensors, remote sensors or potentiometers II (1) G Application Features / Benefits

Isolators A3/1. Vibration Transducer Supply Unit Series

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

XXXX e. X d.. X X X a

Temperature transmitter itemp PCP DIN rail TMT 121

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Isolators A3/1.

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

Resistance thermometer Model TR30, compact design

Resistance thermometer Model TR30, compact design

LENORD. +BAUER... automates motion. GEL 2351 with current or voltage interface. Technical information Version General. Features.

TQ 401 / EA 401 / IQS 451. Proximity System : TQ 401 Proximity Transducer EA 401 Extension Cable IQS 451 Signal Conditioner FEATURES

Inclination Transmitters Heavy Duty

SITRANS F flowmeters. SITRANS F R Rotary-piston meters Accessory modules 4/431. Overview. Siemens AG 2009

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

ABSOLUTE ROTARY ENCODER SSI

Rotary Measurement Technology Incremental Encoders

EURAX VC 603 Programmable combined transmitter/alarm unit

ABSOLUTE ROTARY ENCODER SSI PROGRAMMABLE

0 2 1 â Ó. itemp HART TMT182. Technical Information

TQ 402 & TQ 412 / EA 402 / Proximity System : TQ 402 & TQ 412 Proximity Transducers EA 402 Extension Cable IQS 452 Signal Conditioner FEATURES

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

0 2 1 â Ó. itemp HART TMT182. Technical Information

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Digital Input Output Module for Zone 2 Series 9470/33

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution

Online data sheet ACM36-L1K0-K01 ACS/ACM36 ABSOLUTE ENCODERS

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Temperature Transmitter itemp RTD DIN rail TMT 127

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

Analog Universal Module HART for Zone 2 Series 9468/33

RoHS. High shaft load capacity. Shock / vibration resistant

Temperature transmitter itemp RTD DIN rail TMT 127

Inductive sensor slot-type SI2-K08-AP7

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Binary Output without Power Supply Series 9176

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

Express Delivery. Axial. Connection

itemp HART DIN rail TMT112

TQ 402 & TQ 412 / EA 402 / Proximity System. 三協インタナショナル株式会社東京 :Tel: 大阪 :Tel: 名古屋 :Tel: FEATURES

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

Temposonics. Magnetostrictive Linear Position Sensors. ET Analog Data Sheet

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Temperature Input Module for Zone 1 Series 9482/32

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

OPTITEMP TT 10 C/R Technical Datasheet

Online data sheet. ACM60B-S1KE13x06 ACM60 ABSOLUTE ENCODERS

Positioner with HART Communication Type 3780

Isolating Repeater Input Series 9163

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

ED701 General Industry Pressure Transmitter

POSITION SENSORS TRANSMITTERS FOR ANGULAR POSITION AND INCLINATION TRANSMITTERS ROBUST RELIABLE FLEXIBLE

Transcription:

Ruggedized version Application The KINAX WT 717 (Fig. 1) converts the angular position of a shaft into a load-independent direct current signal, proportional to the angular position. The unit is contact free. The robust housing has made this unit ideal for machines, ship building, transport, construction of vehicles and in the chemical industry. Features / Benefits Measuring range, sense of rotation, characteristic, switching point and other additional functions programmed using PC / Simplifies project planning and engineering, short delivery times, low stocking Measured variable Measuring range limits Programmable between 0 10 and 0 50 Angular position or 0 50 and 0 350 Available in type of protection Intrinsic Safety Ex ia IIC T6 / Can be mounted within the hazardous area (see Table 3: Data on explosion protection ) Simulation of measured values / The testing of the subsequent device chain is already possible during the installation phase Measured value acquisition / Display of the instantaneous value and a trend graph of the measured value on the screen Adjustment / Independent fine adjustment of the analog output, zero position and measuring range Characteristic of the output value / Programmable as a linear, V-characteristic, or any characteristic curve The shaft can be turned through full Patented measuring method Ancillary unit in ruggedized housing / Vibration and shock-resistant, for applications on large machines and in ship building 0102 II 2 G Fig. 1. KINAX WT 717 with foot. The angular defl ection α of the device to be measured is transferred to the rotor R of the differential screen capacitor with the aid of a mechanical coupling. It is then converted into a change of capacitance proportional to the angle. All changes to the position of the rotor result in a change in the capacitance at the input to the microprocessor. This is transformed into a DC current signal proportional to the measured value. Layout and mode of operation The transmitter consists of 2 main parts: the differential screen capacitor D and the electronic circuitry E (Fig. 2). D E α R μp Fig. 2. Block diagram. RS 232 Fig. 3. Print screen example of the menu-controlled programming software. Camille Bauer Data sheet WT 717 Le 01.12 1

Programming A PC, the programming cable PK 610 plus ancillary cable and the confi guration software 2W2 are required to program the transmitter. (Details of the programming cable and the software are to be found in the separate data sheet: PK 610 Le). The connections between PC PK 610 KINAX WT 717 can be seen from Fig. 4. The transmitter can be programmed either with or without the power supply connected. The software 2W2 is supplied on one CD and runs under Windows 95 or higher. The programming cable PK 610 adjusts the signal level between the PC and the transmitter KINAX WT 717. KINAX WT717 Programming connector Ancillary cable Interface PK 610 OFF ON OFF: Power supply by measuring output (see section Electrical connections ) ON: Power supply provided by PC Drive shaft diameter: Frictional torque: Sense of rotation of the drive shaft: Measuring output 19 mm Approx. 25 Ncm Programmable for sense of rotation clockwise or counterclockwise Power supply: H = 12 to 33 V DC (possible with standard version, non-ex) H = 12 to 30 V DC (necessary with Ex version, type of protection Intrinsically safe Ex ia IIC T6) Protected against wrong polarity Output variable I A : Load-independent DC current, proportional to the input angle Zero point correction: Approx. ± 5% Span adjustment: Approx. ± 5% Current limitation: I A max. 40 ma Standard range: 4...20 ma, two-wire External resistance (load): R ext max. [kω] = H [V] 12V I A [ma] H = DC power supply I A = End value of output variable Fig. 4. Example of the set-up for programming a KINAX WT 717 without the power supply. For the case the switch on the interface must be set to ON. Load max. [Ω] with output 20 ma 900 Technical data General Measured quantity: Angle of rotation α Measuring principle: Capacitive method Differential screen capacitor with contact-free, non-wearing positional pick-up. Drive shaft fully rotatable without stops (patented measuring method) Measuring input Measuring range of rotation angle: Programmable between 0 10 and 0 50 (without gear) 0 20 and 0 222 turns (with additional gear) or 0 50 and 0 350 (without gear) 0 100 and 0 1555 turns (with gear) Residual ripple in output current: Response time: Programming connector Interface: 600 0 < 0.3% p.p. < 5 ms Serial interface 10 12 24 Power supply [V] Accuracy data Reference value: Measuring span Basic accuracy: Error limits at reference conditions ± 0.5% Reproducibility: < 0.2% 30 36 2 Data sheet WT 717 Le 01.12 Camille Bauer

Reference conditions Ambient temperature Power supply Output burden Adjustments 23 C ± 2 K 18 V DC 0 Ω 350 version measuring range > 50 350 characteristic linear 50 version measuring range 10 50 characteristic linear Influence effects (maxima) (included in basic error) Dependence on external resistance Δ R ext max. ± 0.1% Power supply infl uence ± 0.1% Additional error (maxima) Temperature infl uence ( 25 + 75 C) ± 0.2% / 10 K Bearing play infl uence ± 0.1% Additional errors (cumulative) Output characteristic Definitions Device version Additional error simple V characteristic 20 ma 350 f = ( 0.18 x 100) MW = MW Angle min. = 0 4 ma 0º 50 f = ( 0.05 x 100) MW V characteristic with offset 20 ma 350 f = ( 0.25 x 100) = (angle max.) (angle min.) = ± fi nal angle Angle min. = > 0 4 ma 50 f = ( 0.09 x 100) any characteristic 20 ma 350 f = ( 0.25 x 100) = (angle max.) (angle min.) 4 ma 50 f = ( 0.09 x 100) Camille Bauer Data sheet WT 717 Le 01.12 3

Mechanical withstand Permissible vibrations: acc. to EN 60 068-2-6 Shock: acc. to EN 60 068-2-27 Mounting position: Any Housing data Material of housing: (main part) Material of back: Material of cable gland: Steel Finish QPQ (nitro-carbonated) Metal (aluminium) Metal On the rear (cover) there are 2 screw terminals and the programming connector (Fig. 5). The screw terminals accept gauges up to max. 1.5 mm 2 and are accessible after removing the cover. Rear (cover) Terminals Cover Rubber seal Cable gland Programming connector Fig. 5. KINAX WT 717 with screw terminals, programming connector and cable gland. Mounting: Directly (instrument without foot, without fl ange) Mounting with foot Mounting with fl ange Weight: See Table 1 Table 1: Weight Description of parts Approx. 2.9 kg KINAX WT 717 without additional gear (also without foot or without fl ange) Approx. 3.9 kg KINAX WT 717 with additional gear (but without foot or without fl ange) 0.5 kg Foot (on its own) 0.5 kg Flange (on its own) Regulations Electromagnetic compatibility: The standards DIN EN 50 081-2 and DIN EN 50 082-2 are observed Housing protection: IP 66 acc. to EN 60 529 Test voltage: 500 Veff, 50 Hz, 1 min. all electric connections against housing Impulse voltage withstand: 1 kv, 1.2/50 μs, 0.5 Ws IEC 255-4, Cl. II Admissible common-mode voltage: 100 V, 50 Hz Environmental conditions Climatic rating: Standard version Temperature 25 to + 70 C Annual mean relative humidity 75% or Version with improved climatic rating Temperature 25 to + 70 C Annual mean relative humidity 95% Ex version see type examination certifi cate Transportation and storage temperature: 25 to 80 C Basic configuration The transmitter KINAX WT 717 is also available already programmed with a basic confi guration which is especially recommended in cases where the programming data is not known at the time of ordering (see Table 2: Specifi cation and ordering information, feature 4). Basic confi guration: Order Code Mechanical angle range Measuring range Switching point Sense of rotation 717-1100 0X0X XXXX X 50 0 50 55 Clockwise Linear 717-1200 0X0X XXXX X 350 0 350 355 Clockwise Linear Characteristic of output variable 4 Data sheet WT 717 Le 01.12 Camille Bauer

Table 2: Specification and ordering information Description *Blocking code No-go with blocking code Article No./ Feature KINAX WT 717 Order code 717 - xxxx xxxx xxxx x 717 Features, Selection 1. Version of the transmitter Standard 1 Ex ia IIC T6, CENELEC/ATEX, measuring output intrinsically safe K 2 Sea-water resistant version L M 3 Sea-water resistant version with additional gear M 4 Ex ia IIC, CENELEC/ATEX, sea-water resistant version LK M 5 2. Mechanical angle range Angle range to 50 1 Angle range > 50 to 350 2 3. Sense of rotation Sense of rotation clockwise D 0 Sense of rotation counterclockwise E 1 For V characteristic F 2 Lines 1 and 2: Not possible for transmitters with basic confi guration 4. Measuring range Basic confi guration, programmed G EF 0 [ angle], 0 to fi nal value / switching point: F 9 Final value 10 to 50º with angle range 50, > 50 to 350º with angle range > 350 Switching point > Final value, max. 60º with angle range 50, > Final value, max. 360º with angle range > 350 105% fi nal value with non-linear characteristic (Lines 1 to 4 in feature 5) V characteristic [± angle], min/max.: DE Z Minimal value: > 0 Maximal value: 25 with angle range 50, Span (max. value min. value) 5 ; > 25 to 175 with angle range > 350, span 25 symmetrical about the center line, e.g. [± angle], min/max.: 15/120 correspond: 120 to 15 to 0 to 15 to 120 angle (input) + 20 to 4 to < 4 to 4 to +20 ma (output) 5. Characteristic of output variable Characteristic linear 0 Function X to the power of 1/2 FG 1 Function X to the power of 3/2 FG 2 Function X to the power of 5/2 FG 3 Customized (on inquiry): Give an algorithm or fi xed points (23 values in 5% steps from 5% to 105% of the measuring range, output continuously variable 10 to 110%) FG 4 Lines 1 to 4: Not possible with V characteristic Camille Bauer Data sheet WT 717 Le 01.12 5

Description *Blocking code No-go with blocking code Article No./ Feature KINAX WT 717 Order code 717 - xxxx xxxx xxxx x 717 Features, Selection 6. Test certificate Without test certifi cate 0 Test certifi cate in German D Test certifi cate in English E 7. Marking the system zero position System zero position not marked 0 System zero position marked G 1 8. Climatic rating Standard climatic rating 0 Improved climatic rating 1 9. Mounting mode Mounting without foot/fl ange With foot (mounted) 1 With fl ange (mounted) 2 10. Marine version Without 0 11. Vibration resistance Standard vibration resistance 0 Increased vibration resistance H M 12. Additional gear 2:1 to 144:1 Without additional gear 0 Transformation 2 : 1 J FHK 1 Transformation 4 : 1 J FHK 2 Transformation 5 : 1 J FHK 3 Transformation 6 : 1 J FHK 4 Transformation 8 : 1 J FHK 5 Transformation 10 : 1 J FHK A Transformation 12 : 1 J FHK B Transformation 12,5 : 1 J FHK C Transformation 15 : 1 J FHK D Transformation 16 : 1 J FHK E Transformation 20 : 1 J FHK F Transformation 22 : 1 J FHK G Transformation 24 : 1 J FHK H Transformation 25 : 1 J FHK J Transformation 30 : 1 J FHK K Transformation 32 : 1 J FHK L Transformation 36 : 1 J FHK M Continuation of table see next page! 6 Data sheet WT 717 Le 01.12 Camille Bauer

Description *Blocking code No-go with blocking code Article No./ Feature KINAX WT 717 Order code 717 - xxxx xxxx xxxx x 717 Features, Selection 12. Additional gear 2:1 to 144:1 (Continuation) Transformation 40 : 1 J FHK N Transformation 50 : 1 J FHK O Transformation 60 : 1 J FHK P Transformation 64 : 1 J FHK Q Transformation 72 : 1 J FHK R Transformation 75 : 1 J FHK S Transformation 80 : 1 J FHK T Transformation 100 : 1 J FHK U Transformation 120 : 1 J FHK V Transformation 144 : 1 J FHK W 13. Additional gear 150:1 to 1600:1 Without additional gear 0 Transformation 150 : 1 FHJK 1 Transformation 160 : 1 FHJK 2 Transformation 180 : 1 FHJK 3 Transformation 200 : 1 FHJK 4 Transformation 240 : 1 FHJK A Transformation 250 : 1 FHJK B Transformation 300 : 1 FHJK C Transformation 330 : 1 FHJK D Transformation 360 : 1 FHJK E Transformation 375 : 1 FHJK F Transformation 400 : 1 FHJK G Transformation 450 : 1 FHJK H Transformation 480 : 1 FHJK J Transformation 500 : 1 FHJK K Transformation 550 : 1 FHJK L Transformation 600 : 1 FHJK M Transformation 660 : 1 FHJK N Transformation 720 : 1 FHJK O Transformation 750 : 1 FHJK P Transformation 800 : 1 FHJK Q Transformation 880 : 1 FHJK R Transformation 900 : 1 FHJK S Transformation 1000 : 1 FHJK T Transformation 1024 : 1 FHJK U Transformation 1200 : 1 FHJK V Transformation 1600 : 1 FHJK W Lines with letter(s) under No-go cannot be combined with preceding lines having the same letter under Blocking code. Camille Bauer Data sheet WT 717 Le 01.12 7

Table 3: Data on explosion protection Order Code 717-2 717-5 Type of protection Intrinsically safe Marking Instrument Ex ia IIC T6 U i I i Measuring output = 30 V = 160 ma P i = max. 1 W C i = 6.6 nf L i 0 Certifi cates Type examination Certifi cate ZELM 03 ATEX 0123 Mounting location of device Within the hazardous area, zone 1 Electrical connections Table 4: Accessories and spare parts H = DC power supply H = 12 33 V Description Programming cable PK 610 Order No. 137 887 R ext = External resistance DSUB 9p F Interface 1 meter Ancillary cable 141 440 1.5 meter R ext + + H Standard accessories 1 Operating Instructions in three languages: German, French, English 1 Ex approval (for instruments in Ex version only) Confi guration software 2W2 Windows 95 or higher on CD in German and English (Download free of charge under http://www.camillebauer.com) In addition, the CD contains all configuration programmes presently available for Camille Bauer products Operating instructions WT 717 Bd-f-e in German, French and English 146 557 151 259 Dimensional drawings M6 x 15 6.5 15 60 102 Ø 62 f8 76.5 147 82 ±0.2 102 61.5 1 56 36 71 ±0.2 Ø 9 119 90 ±0.2 147 114 Fig. 6. KINAX WT 717. Fig. 7. KINAX WT 717 with foot. 8 Data sheet WT 717 Le 01.12 Camille Bauer

3.5 55 M6 x 15 9.5 Ø 110 f7 65 11.5 147 130 ±0.2 160 Ø 62 f8 76.5 82 ±0.2 211 102 Fig. 8. KINAX WT 717 with fl ange. Fig. 9. KINAX WT 717 with additional gear. 6.5 15 60 102 3.5 55 9.5 56 Ø 110 f7 61.5 36 71 ±0.2 119 1 Ø 9 90 ±0.2 211 114 65 11.5 211 130 ±0.2 160 Fig. 10. KINAX WT 717 with additional gear and foot. Fig. 11. KINAX WT 717 with additional gear and fl ange. Rely on us. Camille Bauer Ltd Aargauerstrasse 7 CH-5610 Wohlen / Switzerland Phone: +41 56 618 21 11 Fax: +41 56 618 35 35 info@camillebauer.com www.camillebauer.com Subect to change without notice Edition 01.12 Data sheet WT 717 Le