Amrex. MS324A * Low Volt AC Stimulator. User's Guide. electrotherapy equipment a division of Amrex-Zetron, Inc.

Similar documents
Amrex. MS324C * Low Volt AC Stimulator. User's Guide. electrotherapy equipment a division of Amrex-Zetron, Inc.

Z-STIM IF250 * Interferential / Russian Stimulator

Amrex. SynchroSonic U/HVG50 * User's Guide. electrotherapy equipment a division of Amrex-Zetron, Inc.

Transcutaneous Electrical Nerve Stimulator TENS 212. Instruction Manual. Read before using

Instruction Manual. CAUTION: Federal law requires a prescription from your physician before use of this product.

Trio*Stim. Instruction Manual

This manual is valid for the TM. In TENSity 5000 TENS Stimulator. This user manual is published by Current Solutions, LLC

Glass Electrode Meter

INTRODUCTION. It is also intended for symptomatic relief and management of chronic, intractable pain and relief of pain associated with arthritis.

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

CyMedica Orthopedics. e-vive USER S MANUAL. Read this manual carefully before operating the e-vive System. Customer Service CYM-2014

Sys * Stim 228. Instruction Manual

ELECTROSURGICAL UNIT ANALYZER

Broadband Step-Up Transformer. User Manual

F R F R G

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

MICROWAVE DIATHERMY AND SURGICAL DIATHERMY DIATHERMICS

DL102 Counter Loop Amplifier

HTA125A/250A. Power Amplifiers. Installation & Use Manual

User Manual Operation & Installation Instructions for: Two Channel Transportable Electrotherapy Unit

SERVICE MANUAL. Dynatron 950plus & Dynatron 650plus

Moving Rehabilitation Forward. User Manual Combination Ultrasound and Stimulation Unit. ISO Certified

Classic Series Public Address Amplifiers C10 & C20 Models

Sonicator Plus 940. Instruction Manual

80i-600A AC Current Probe

INSTRUCTION MANUAL. March 11, 2003, Revision 3

INSTRUCTION MANUAL LKG

INSTRUCTION MANUAL INF Fax: (503)

TENS / EMS Dual Channel Electrical Stimulator Model GF-DF5

INTELECT. User Manual LEGEND SERIES COMBO. Models 2C & 4C ISO CERTIFIED

12B/18 MultiMeter Instruction Sheet

GMINI 300PE AM/FM/Shortwave Radio OWNER S MANUAL

AS SUPER 4 digital. Elektrischer Nadelstimulator / Electrical needle stimulator. Art.-Nr

Classic Series Public Address Amplifiers C10 & C20 Models

36 AC/DC True RMS. Clamp Meter. P Read First: Safety Information

Exercise Heart Rate Sensor

Sys * Stim 294. Instruction Manual

Sonicator Plus 930. Instruction Manual

Space Invaders OPERATING MANUAL. Model # 402-1

MULTISTIM MS100 Neuro-muscular Stimulator

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

Empi Elite COMPLETE ELECTROTHERAPY SYSTEM. USER S MANUAL Read this manual carefully before operating the Elite Visit us at

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

PULSE OXIMETRY SIMULATOR

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

TAG5000 WIRELESS PHASER. Instruction Manual HD ELECTRIC COMPANY 1475 LAKESIDE DRIVE WAUKEGAN, ILLINOIS U.S.A.

INSTRUCTION MANUAL UTL260

Warranty Terms & Conditions

Sonicator Plus 994. Instruction Manual

LSI System IV. Interferential with Russian Stimulation Owner s Manual

AT Advanced Wire Tracer. Users Manual

Radio Remote(s) (Installation Manual)

DA560D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

CT-2 and CT-3 Channel Taggers OPERATION MANUAL

User Manual. Before Using Your WiTouch Pro Device

INSTRUCTION MANUAL FOR THE

DA6002D-DA10004D. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

Four-Channel Differential AC Amplifier

742A Series Resistance Standards

DA604D DA954D DA501D DA801D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

TK 100 Probe Calibrator. Instruction Manual

Keychain Radio Remote Control System

Broadband Current Probe Series Operation Manual

FR250 OPERATION MANUAL

INSTRUCTION MANUAL FOR MICROELECTRODE AC AMPLIFIER MODEL 1800

Mini TENS. User Manual. Natural, drug-free pain relief. 20 Minute Treatment Single Patient Use. Model ACRL Clinically Proven

PRODUCT CODE: XT EN

XPR522 XPR540. XPR SERIES INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

ECG PATIENT SIMULATOR FIVE LEAD

ELECTRICAL CURRENT FOR PAIN CONTROL

TENSPros. Twin Stim Plus 3 rd Edition INSTRUCTION MANUAL. Combo Stimulator

MICRO SERIES MONITORS

Opus 21 s80 Integrated Amplifier Owner's Manual

INSTRUCTION MANUAL FOR CELL SIMULATOR MODEL 2410

User Manual. Moving Rehabilitation Forward. Operation & Installation Instructions for: Two Channel Mobile Stimulation Unit

BodyclockStimplusManual.qx8_Layout 1 17/08/ :53 Page 1. Body Clock Stimplus. Instructions for use

Neo Ultrasound Module Manual

ECG PATIENT SIMULATOR SIX LEAD

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

MODEL 3810/2 Line Impedance Stabilization Network

4. CONNECTIONS. Make sure all connections to and in your Universal Rectifier are tight.

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: 912 Power Amplifier. P/N: Rev 2

Empi COMPLETE ELECTROTHERAPY SYSTEM USER S MANUAL. Read this manual carefully before operating the Phoenix. Visit us at

Radio Remote Controls Manual K Series

INDEX. Chapter Contents Page

DC200A Displacement Clipper User Manual

INDEX. Chapter Contents

DUAL LEVELAR. Two Channel Tube Compressor/Leveling Amplifier

Owner s Manual & Safety Instructions

MINNOVATM INSTRUCTION MANUAL

Prime Engineering Up-Rite Stander

Broadband Current Probe Series Operation Manual

This manual is valid for the InTENSity TM Twin Stim III TENS/EMS Combo Stimulator

XPA2100 XPA4100 XPA6100. XPA SERIES INSTALLATION/OWNER S MANUAL Mobile Power Amplifiers

EQ-AMP60 60W Mixer Amplifier

RICH-MAR Theratouch 7.7-S

Model 113 Scintillation Preamplifier Operating and Service Manual

AT Underground Cable/Pipe Locator System. Users Manual Mode d emploi Bedienungshandbuch Manuale d Uso Manual de uso Användarhandbok

Mini300PE OPERATION MANUAL AM/FM/SHORTWAVE RADIO

MICROTOOLS MICRONETBLINK KIT

Transcription:

MS324A * Low Volt AC Stimulator User's Guide Amrex electrotherapy equipment a division of Amrex-Zetron, Inc. *Federal law (USA) restricts this device to sale by or on the order of a licensed practitioner licensed by the law of the state in which he practices to use or order the use of this device.

MS324A User's Guide Low Volt AC Stimulator Revised February 2014 Copyright Amrex-Zetron, Inc. 1995. All rights reserved. Printed in the United States of America The following are registered or trademarked by Amrex: Amrex SynchroSonic Flextrode AMREX electrotherapy equipment a division of Amrex-Zetron, Inc. 7034 Jackson Street Paramount, California 90723 (310) 527-6868 Toll Free Customer Service (800) 221-9069 Fax (310) 366-7343 E-Mail: amrex@amrex-zetron.com Web Site: http://www.amrexusa.com

Thank you... for selecting the Amrex MS324A Low Volt AC Stimulator. We believe that you will find this instrument to be versatile, dependable and user friendly. The MS324A is designed for the application of low volt ac muscle stimulation. The Amrex MS324A Low Volt AC Stimulator is a dual channel, four pad, low voltage electrical muscle stimulator that produces pulsation, tetanize, surge and reciprocal output. The electrical muscle stimulation may be applied separately or may be combined with ultrasound simultaneously through the ultrasound transducer using an external Amrex SynchroSonic U/50. Your MS324A has been manufactured by a group of dedicated, highly trained employees who exemplify the sixty year Amrex tradition of manufacturing therapeutic equipment of the highest quality while supporting you with prompt, courteous customer service. Upon receipt of your MS324A, verify your accessories against the enclosed check list. Promptly return the postage paid Registration Card to Amrex. Save the original shipping carton and all packing materials. Please carefully review this User s Guide prior to operating the Amrex MS324A Low Volt AC Stimulator. Should you have questions regarding your new purchase, or need assistance, telephone Amrex Technical Services at (800) 221-9069. i

Limited Warranty Amrex-Zetron, Inc. (Manufacturer) warrants each instrument it manufactures to be free from defects in material and workmanship under normal use and service for a period of two (2) years from the date of purchase. This two year warranty extends only to the original purchaser and shall not apply to batteries, fuses, accessories or any instrument which has been subjected to misuse, neglect, accident or abnormal conditions of operation. The Manufacturer's obligation under this warranty is limited to repairing or replacing, at the Manufacturer's option, any instrument returned to the factory within two (2) years from the date of purchase. If the Manufacturer determines that the product fails to conform to this warranty due to misuse, alteration or abnormal condition of operation, including evidence that nonauthorized personnel have attempted to repair the device, the instrument will be repaired at customers expense. This warranty is exclusive and in lieu of all other warranties, expressed or implied, including but not limited to any other warranty of merchantability or fitness for any particular purpose. Manufacturer shall not be liable for any special, incidental or consequential damages, whether in contract, tort or otherwise. Service and Shipping Information Amrex Technical Services has a representative to assist you should your equipment require service or repair. It is necessary to obtain a Return Merchandise Authorization (RMA) number before returning equipment to the factory for warranty repair. Call our representative toll free (800) 221-9069. Damage, resulting from repairs made outside the factory, is not covered under the warranty. To maintain original design specifications, your Amrex muscle stimulator must be calibrated and safety tested on an annual basis. Amrex strongly recommends that servicing be referred to the factory. Call toll free (800) 221-9069. Save the original shipping carton and all packing materials to safely return Amrex equipment to the factory for service; repair; annual calibration, electrical and mechanical safety check. All accessories, including the ac line cord, must be included with the returned instrument. The customer is responsible for all freight charges. The Manufacturer shall assume NO responsibility for damage in transit. ii

Contraindications Warnings Precautions THIS INSTRUMENT OPERATES ON 120 VOLTS AC, 60 Hz. (unless otherwise indicated on the unit) AND MUST BE PROPERLY GROUNDED FOR SAFETY. The three wire power cord with "hospital grade" plug should be connected to a GROUNDED AC wall receptacle. It is the personal responsibility and obligation of the user to insure that this instrument is properly connected to the AC POWER source before use. Warning Risk of burns and fire. DO NOT use near conductive material such as metal bed parts or innerspring mattresses. Renew electrode cables upon evidence of deterioration. Use of controls, adjustment, or performance of procedures, other than those specified herein, may result in hazardous exposure to electrical energy. Important AMREX Intensity Reset Circuit: The Amrex Low Volt AC Stimulator incorporates a unique safety reset function as part of the intensity controls. This is to prevent any sudden or inadvertent stimulation output to the patient in the event that: The Low Volt AC Intensity controls are not set to the 0/Reset position enabling the audible "clicks" at power on, provided the power has been off for more than ten seconds. The ac power is interrupted for more than ten seconds before power is restored. The treatment period has ended and more than ten seconds has elapsed before power on. The Low Volt AC Intensity controls must be returned to the 0/Reset position enabling the audible "clicks" before stimulation output can be activated. Patient "Treatment Stop" Switch: When the patient "Treatment Stop" switch is activated, stimulator output will be discontinued immediately. The Reset Intensities indicator light will illuminate. Stimulator output cannot be resumed until the Low Volt AC Intensity controls for Channel A and Channel B are returned to the 0/Reset position enabling the audible "clicks" which will turn off the Reset Intensities indicator light. NOW the stimulator output can be activated iii

Electrical Muscle Stimulation Contraindications Contraindicated for patients with cardiac demand pacemakers. Should not be used on cancer patients. Electrical Muscle Stimulation Warnings Long term effects of chronic electrical stimulation are unknown. Safety has not been established for the use of electrical muscle stimulation during pregnancy. Adequate precautions should be taken in the case of persons with suspected heart problems. Adequate precautions should be taken in the case of persons with suspected or diagnosed epilepsy. Do not stimulate over the carotid sinus nerves, especially in patients with a known sensitivity to the carotid sinus reflex. Severe spasm of the laryngeal and pharyngeal muscles may occur when the electrodes are positioned over the neck or mouth. The contractions may be strong enough to close the airway or cause difficulty in breathing. Electrical muscle stimulators should not be applied transcerebrally. Electrical muscle stimulators should not be used over swollen, infected or inflamed areas or skin eruptions. Caution should be used in the transthoracic application of electrical muscle stimulators in that the introduction of electrical current into the heart may cause arrhythmias. Electrical muscle stimulators should be kept out of the reach of children. Electrical Muscle Stimulation Precautions Precautions should be observed: When there is a tendency to hemorrhage following acute trauma or fracture. Following recent surgical procedures when muscle contraction may disrupt the healing process. Over the menstruating uterus. Where sensory nerve damage is present by a loss of normal skin sensation. Some patients may experience skin irritation or hypersensitivity due to the electrical stimulation or the conductive medium. The irritation can usually be reduced by use of an alternate conductive medium or alternate electrode placement. Skin irritation and burns beneath the electrodes have been reported with the use of electrical muscle stimulators. iv

Table of Contents Part 1 Overview... 1 Part 2 Power Section... 5 Part 3 Low Volt AC Stimulator Modality... 9 Part 4 MS324A General Operation and Application Procedures... 15 General Operation... 15 Application of Electrical Muscle Stimulation... 17 Adverse Effects - Shortwave Diathermy Interference... 18 Electrical Muscle Stimulation Indications... 19 Electrical Muscle Stimulation Contraindications... 19 Electrical Muscle Stimulation Warnings... 19 Electrical Muscle Stimulation Precautions... 20 Appendix A Specifications... 21 Appendix B References... 23 v

vi

Overview Part 1 AMREX The layout of the MS324A panel consists of controls, indicator lights, and output jacks. Low Volt AC Stimulator Power / Timer Minimum 0 / Reset Maximum Reset Intensities Minimum 0 / Reset Maximum Output Rate A Output Rate B MS324A User's Guide 1

Part 1 In the illustration below, dashed lines surround each of the MS324A's sections. A brief description of each section follows the illustration, and Parts 2 and 3 of this manual contain detailed descriptions. Low Volt AC Stimulator Power / Timer Minimum 0 / Reset Maximum Reset Intensities Minimum 0 / Reset Maximum Output Rate A Output Rate B 2 MS324A User's Guide

Power Section Overview Use the Power/Timer to activate the main ac power and set the treatment duration. When the treatment is complete the power will shut off and a bell will sound. Low Volt AC Stimulator Modality Section Set the intensities and monitor the output of low volt ac stimulation with the controls and connectors in this section of the panel. Select either pulsation, tetanize, surge or reciprocal output using the Output Mode control. Regulate the frequency of the pulses, or adjust the duration of the surge or reciprocal, with the Pulse/ Surge Rate control. MS324A User's Guide 3

Part 1 4 MS324A User's Guide

Power Section Part 2 AMREX In the illustration below, dashed lines surround the MS324A's power section. Low Volt AC Stimulator Power / Timer Minimum 0 / Reset Maximum Reset Intensities Minimum 0 / Reset Maximum Output Rate A Output Rate B MS324A User's Guide 5

Part 2 The power section of the MS324A panel is depicted below. Items referenced with circled numbers (1 4) are explained on the following page. Power / Timer Minimum 0 / Reset Maximum Reset Intensities Minimum 0 / Reset Maximum Month/Year MS324A 00000 6 MS324A User's Guide

Power Section 1. POWER/TIMER: Controls the main ac power as well as the timer for treatment. Turn the Power/Timer knob clockwise past the 10 minute mark and then set it to the desired treatment time. The On indicator light (located above the upper right corner of the Power/Timer) will illuminate. The ac power will shut off and a bell will sound when treatment is completed. To initiate early shut off, turn the Power/Timer knob counterclockwise to the Off position. The ac power will shut off and a bell will sound. 2. ON INDICATOR LIGHT: Will illuminate when the Power/Timer is activated. 3. AC RECEPTACLE: Connection for MS324A's ac power cord. 4. VELCRO WASHER: To attach wall mount velcro bracket strap. MS324A User's Guide 7

Part 2 8 MS324A User's Guide

Part 3 AMREX Low Volt AC Stimulator Modality In the illustration below, dashed lines surround the MS324A's low volt ac stimulator section. Low Volt AC Stimulator Power / Timer Minimum 0 / Reset Maximum Reset Intensities Minimum 0 / Reset Maximum Output Rate A Output Rate B MS324A User's Guide 9

Part 3 The low volt ac stimulator section of the MS324A panel is depicted below. Items referenced with circled numbers (5 8) are explained on the following page. Minimum 0 / Reset Maximum Reset Intensities Minimum 0 / Reset Maximum Output Rate A Output Rate B 10 MS324A User's Guide

Low Volt AC Stimulator Modality 5. LOW VOLT AC OUTPUT MODE CONTROL: (SELECTIONS): Pulsation Pulsed output (variable from 1 to 80 pulses per second) Tetanize Continuous output (set at 80 pulses per second) Surge Surged output simultaneously on Channel A and Channel B (set at 80 pulses per second, surge rate duration variable from 3.75 seconds on, 3.75 seconds off to 0.375 second on, 0.375 second off) Reciprocal Reciprocal output alternates between Channel A and Channel B (set at 80 pulses per second, reciprocal rate duration variable from 3.75 seconds on, 3.75 seconds off to 0.375 second on, 0.375 second off) 6. PULSE / SURGE RATE CONTROL: Pulsation Mode Regulates the pulsation rate from Slow (1 pulse per second) to Rapid (maximum of 80 pulses per second) Surge Mode Regulates the surge rate of Channel A and Channel B from Slow (3.75 seconds on, 3.75 seconds off) to Rapid (0.375 second on, 0.375 second off) Reciprocal Mode Regulates the reciprocal rate of Channel A and Channel B from Slow (3.75 seconds on, 3.75 seconds off) to Rapid (0.375 second on, 0.375 second off) Note: The Pulse / Surge Rate control has no effect in the Tetanize Mode. 7. LOW VOLT AC CHANNEL A INTENSITY CONTROL: Regulates the stimulator output for Channel A from 0 to Maximum. Note: The Low Volt Intensity control for Channel A has a unique reset circuit feature which prevents the practitioner from applying one patient's treatment settings to another patient. The AMREX Reset Circuit also allows the continuation or extension of the patient's treatment period if power is restored within ten (10) seconds. 8. LOW VOLT AC CHANNEL B INTENSITY CONTROL: Regulates the stimulator output for Channel B from 0 to Maximum. Note: The Low Volt Intensity control for Channel B has a unique reset circuit feature which prevents the practitioner from applying one patient's treatment settings to another patient. The AMREX Reset Circuit also allows the continuation or extension of the patient's treatment period if power is restored within ten (10) seconds. MS324A User's Guide 11

Part 3 The low volt ac stimulator section of the MS324A panel is depicted below. Items referenced with circled numbers (9 14) are explained on the following page. Minimum 0 / Reset Maximum Reset Intensities Minimum 0 / Reset Maximum Output Rate A Output Rate B 12 MS324A User's Guide

Low Volt AC Stimulator Modality 9. LOW VOLT AC RESET INTENSITIES INDICATOR LIGHT: When power is restored more than ten seconds after being interrupted or turned off, or more than ten seconds after the treatment period has been completed and the bell has sounded, the Low Volt AC Reset Intensities indicator light will illuminate. The Intensity controls for Channel A and Channel B must be returned to the 0/Reset position enabling the audible "clicks" which will turn off the Reset Intensities indicator light. NOW the stimulator output can be activated. When power is restored within ten (10) seconds after being interrupted or turned off, or within ten (10) seconds after the treatment period has been completed and the bell has sounded, the AMREX Reset circuit will be bypassed and the Reset Intensities indicator light will not illuminate. This will allow the continuation or extension of the patient's treatment period. 10. OUTPUT RATE A INDICATOR LIGHT: Reflects the output rate for Pulsation, Tetanize, Surge or Reciprocal Mode of Channel A. 11. OUTPUT RATE B INDICATOR LIGHT: Reflects the output rate for Pulsation, Tetanize, Surge or Reciprocal Mode of Channel B. 12. LOW VOLT AC STIMULATOR CHANNEL B OUTPUT JACKS 13. "TREATMENT STOP" JACK: Provides for connection to patient "Treatment Stop" switch. Note: When the patient "Treatment Stop" switch is activated, stimulator output will be discontinued immediately. The Reset Intensities indicator light will illuminate. Stimulator output cannot be resumed until the Intensity controls for Channel A and Channel B are returned to the 0/Reset position enabling the audible "clicks" which will turn off the Reset Intensities indicator light. NOW the stimulator output can be activated. 14. LOW VOLT AC STIMULATOR CHANNEL A OUTPUT JACKS MS324A User's Guide 13

Part 3 14 MS324A User's Guide

MS324A General Operation and Application Procedures Part 4 AMREX General Operation 1. Connect the MS324A's ac power cord to the MS324A's ac receptacle and plug the "Hospital Grade" connector to a properly grounded 120Vac, 60Hz receptacle. 2. Connect the patient "Treatment Stop" Switch to the "TREATMENT STOP" JACK. 3. Reduce the Low Volt AC Intensity controls for Channel A and Channel B to the 0/Reset position enabling the audible "clicks". 4. Set the Low Volt AC Output Mode control to Tetanize. 5. Set the Pulse/Surge Rate control at the Slow position. 6. Prepare the pad electrodes and apply them to the patient. They may be held in place by means of retention straps or weight bags. Hand the "Treatment Stop" Switch to the patient and explain its function. 7. Turn the Power/Timer knob and set it to the desired treatment time. Note: When the treatment time is less than ten (10) minutes, turn the Power/ Timer knob clockwise past the ten (10) minute mark and then set it back to the desired time. The On indicator light (located above and to the right of the Power/Timer) will illuminate. 8. Verify that the Low Volt AC Intensity controls for Channel A and Channel B are set at the 0/Reset position. MS324A User's Guide 15

Part 4 9. Slowly increase the Low Volt AC Intensity control(s) for Channel A and/or Channel B to the desired output levels. Note: If the Reset Intensities indicator light is illuminated, no output will be obtained until the Intensity controls for Channel A and Channel B are returned to the 0/Reset position enabling the audible "clicks". 10. Select an alternate Output Mode, Pulsation, Surge or Reciprocal, and adjust the Pulse/Surge Rate control if so desired. The Output Rate indicator lights will reflect the output rate selected. 11. When treatment is completed, the ac power will shut off and a bell will sound. To continue or extend a patient's treatment time, reset the Power/Timer knob within ten (10) seconds of shut off. To initiate early shut off, turn the Power/ Timer knob counterclockwise to the Off position. The ac power will shut off and a bell will sound. Reduce the Intensity controls for Channel A and Channel B to the 0/Reset position enabling the audible "clicks". Thoroughly clean the pad(s) with warm water and dispose of the used cloth cover(s). 16 MS324A User's Guide

Application of Electrical Muscle Stimulation MS324A General Operation and Application Procedures Electrical muscle stimulation, high voltage or low voltage ac, is usually applied through carbon type pad electrodes with disposable cloth covers, or sponge type pad electrodes. The Flextrode System has been designed for the application of electrical stimulation with the use of carbon type electrodes. The Flextrode pad electrode must be used with the Flextrode disposable cloth cover. The cloth cover provides added hygienic protection and increased conductance to the patient. To obtain maximum conductivity, it is important to properly prepare the Flextrode pad electrode and cloth cover before application of electrical muscle stimulation. The Flextrode pad electrode and cloth cover assembly must be completely and thoroughly moistened by immersing it in water. Apply a generous amount of Flextrode Conductive Spray to the moistened cloth cover. If the Flextrode Conductive Spray is not desired, apply a generous amount of Amrex Conductance and Coupling Gel to the thoroughly moistened Flextrode cloth cover. A generous amount of Flextrode Conductive Spray or Amrex Conductance and Coupling Gel is required to insure good conductivity. Thoroughly clean pad(s) with warm water after each treatment and dispose of the used cloth cover(s). Important It is the personal responsibility and obligation of the user to verify that patient cords and electrode pads show no evidence of deterioration prior to patient application. When such evidence exists, replace the cords or electrodes. Never sharply bend or twist the cords. Loose connections or broken cords can cause poor conductance and possible discomfort to the patient. Should the patient complain of low stimulation output, no output or sudden irregular increases in output, immediately discontinue treatment. Check for the following: secure cord connections; proper electrode contact with the patient; electrode wear or lack of cleanliness. Replace patient cords and/or pad electrodes that show any evidence of deterioration. MS324A User's Guide 17

Part 4 Adverse Effects - Shortwave Diathermy Interference It is extremely important for the physiotherapist to have a clear understanding of the potential danger involved in the use of a low volt ac stimulator device in close proximity to an active shortwave diathermy unit. A medical shortwave diathermy unit is a very powerful transmitter of radio energy, the larger ones having an output of 500 watts. Any low volt ac stimulator device with external leads, in close proximity to a shortwave unit, is likely to be affected by interference. This interference may be in the form of sparking between electrodes or between the leads and the device casing. The leads connecting the low volt ac stimulator device to the patient can act as an aerial and collect the radio frequency energy from the shortwave unit. This could interfere with the operation of the low volt ac stimulator unit or affect internal functions of the device. Or, it could result in the patient experiencing some unusual "surges" of current. There is no significant electrical radiation from a low volt ac stimulator device. The increasing electronic sophistication of physiotherapeutic equipment is likely to mean that this problem is going to become more obvious. The minimum safe operating distance is difficult to determine since local factors must be considered. At least two or three meters is needed between the nearest parts of either instrument, including the cables and electrodes. The low volt ac stimulator device does not need to be plugged into a power supply to be affected by interference from a shortwave unit. Some very old types of shortwave generators seem to produce more interference than others which compounds the problem even further. With some shortwave units, the distance between devices of at least three meters may still be inadequate. In practice, shortwave diathermy units and low volt ac stimulator units should be placed and operated as far away from each other as possible. It may be necessary to screen off all shortwave units from other equipment or to have fully screened rooms in which shortwave diathermy equipment can be operated without risk of interfering with other sensitive equipment. This is often difficult in a small practice where space is at a premium. In such cases, the units may have to be operated at different times, not simultaneously. In all cases, it would be very dangerous to give shortwave diathermy and low volt ac stimulator treatment to a patient simultaneously. Any patient who reports a sudden, unexplainable "surge" in output may be experiencing the effects of shortwave interference. 18 MS324A User's Guide

Electrical Muscle Stimulation Indications Relaxation of muscle spasms Prevention or retardation of disuse atrophy Increased local blood circulation Muscle reeducation MS324A General Operation and Application Procedures Maintenance of or increase in range of motion Immediate postsurgical stimulation of calf muscles to prevent venous thrombosis Electrical Muscle Stimulators should only be used under medical supervision for adjunctive therapy for the treatment of medical diseases and conditions. Electrical Muscle Stimulation Contraindications Contraindicated for patients with cardiac demand pacemakers. Should not be used on cancer patients. Electrical Muscle Stimulation Warnings Long term effects of chronic electrical stimulation are unknown. Safety has not been established for the use of electrical muscle stimulation during pregnancy. Adequate precautions should be taken in the case of persons with suspected heart problems. Adequate precautions should be taken in the case of persons with suspected or diagnosed epilepsy. Do not stimulate over the carotid sinus nerves, especially in patients with a known sensitivity to the carotid sinus reflex. Severe spasm of the laryngeal and pharyngeal muscles may occur when the electrodes are positioned over the neck or mouth. The contractions may be strong enough to close the airway or cause difficulty in breathing. Electrical muscle stimulators should not be applied transcerebrally. Electrical muscle stimulators should not be used over swollen, infected or inflamed areas or skin eruptions. Caution should be used in the transthoracic application of electrical muscle stimulators in that the introduction of electrical current into the heart may cause arrhythmias. Electrical muscle stimulators should be kept out of the reach of children. MS324A User's Guide 19

Part 4 Electrical Muscle Stimulation Precautions Precautions should be observed: When there is a tendency to hemorrhage following acute trauma or fracture. Following recent surgical procedures when muscle contraction may disrupt the healing process. Over the menstruating uterus. Where sensory nerve damage is present by a loss of normal skin sensation. Some patients may experience skin irritation or hypersensitivity due to the electrical stimulation or the conductive medium. The irritation can usually be reduced by use of an alternate conductive medium or alternate electrode placement. Skin irritation and burns beneath the electrodes have been reported with the use of electrical muscle stimulators. 20 MS324A User's Guide

Specifications Input Power Requirements Line Voltage... 120 Vac, 60 Hz (Special voltages available on request) Current... 0.25 A Line Leakage... < 50 µa Electrical Stimulator Waveform... asymmetrical alternating current (no load) +V Instrument Overall Dimensions... 8½" W x 11" D x 5¾" H Weight... 4.5 Lbs Shipping Weight... 11 Lbs Cleaning Instructions 1. Disconnect the power supply. 2. Use mild soap with a lightly moistened cloth. 3. Air dry before using. Appendix A 0 t -V Output Voltage... 110 V peak into 1K ohm load 28 V peak into 100 ohm load Output Intensity... 56 µc maximum charge per pulse into 100 ohm load Pulse Width... 200 µs at 50% V maximum Frequency Pulsation Mode... 1 to 80 pps Tetanize Mode... 80 pps Surge Mode... 80 pps Reciprocal Mode... 80 pps Surge Duration (seconds)... variable from 3.75 on/off to 0.375 on/off Reciprocal Duration (seconds)... variable from 3.75 on/off to 0.375 on/off MS324A User's Guide 21

Appendix A Service and Shipping Information Amrex Technical Services has a representative to assist you should your equipment require service or repair. It is necessary to obtain a Return Merchandise Authorization (RMA) number before returning equipment to the factory for warranty repair. Call our representative toll free (800) 221-9069. Damage, resulting from repairs made outside the factory, is not covered under the warranty. To maintain original design specifications, your Amrex stimulator must be calibrated and safety tested on an annual basis. Amrex strongly recommends that servicing be referred to the factory. Call toll free (800) 221-9069. Save the original shipping carton and all packing materials to safely return Amrex equipment to the factory for service; repair; annual calibration, electrical and mechanical safety check. All accessories, including the ac line cord, must be included with the returned instrument. The customer is responsible for all freight charges. The Manufacturer shall assume NO responsibility for damage in transit. 22 MS324A User's Guide

References Appendix B Alon, G. High Voltage Stimulation (High Voltage Pulsating Direct Current). Chattanooga Corporation, Chattanooga, Tennessee, 1984. Currier, D.P. and R.M. Nelson. Clinical Electrotherapy. Appleton and Lange, Norwalk, Connecticut, 1986. Dyson, M. Mechanisms Involved in Therapeutic Ultrasound. Physiotherapy, March, Vol.73.3, pp.116-120, 1987. Jaskoviak, P.A. and R.C. Schafer. Applied Physiotherapy. ACA Press, Arlington, Virginia, 1986. Kahn, J. Iontophoresis and Ultrasound for Post Surgical TMJ Trismus and Paresthesia. Physical Therapy, March 1980, 60:3. Kahn, Joseph. Principles and Practice of Electrotherapy. Churchill Livingstone, New York, 1987. Kleinkort, J.A. and F. Wood. Phonophoresis with 1% Versus 10% Hydrocortisone. Physical Therapy, 55:1320-1324, 1975. Kottke, F.J., G.K. Stillwell and J.F. Lehman, ed. Krusen s Handbook of Physical Medicine and Rehabilitation. W.B. Saunders Co., Philadelphia, 1982. Michlovitz, S.L. and S.L. Wolf, ed. Thermal Agents in Rehabilitation. F.A. Davis Co., Philadelphia, 1986. Nix, W.A. and G. Vrbova. Electrical Stimulation and Neuromuscular Disorders. Springer-Verlag, Berlin, West Germany, 1986. Nyborg, W.L. and M.C. Ziskin, ed. Biological Effects of Ultrasound. Vol. 16 of Clinics in Diagnostic Ultrasound. Churchill Livingstone, New York, 1985. Peat, Malcolm, ed. Current Physical Therapy. B.C. Decher, Inc., Philadelphia, Pennsylvania, 1988. MS324A User's Guide 23

Appendix B 24 MS324A User's Guide