Endoscopic Suturing Devices

Similar documents
Intracorporeal Knot-Tying and Suturing Techniques in Laparoscopic Surgery: Technical Details

Endoscopic management of common patologies with a new suturing system

Single balloon Enteroscope system SIF-Q180 / OBCU

The use of sutures and ligatures is an integral part of surgical procedures. Being proficient in suturing and ligating will not only make your

Procedure Guide. Eliminate Big Problems Safely and Quickly Close Your Patients Port Sites

WHEN IT COMES TO SUTURING, EXPERIENCE MATTERS.

University of Alabama at Birmingham. ObGyn Residency. Laparoscopy Training Lab PGY 1-4. Individual Pelvic Trainer Tasks

Techniques of the hand tie and instrument tie

Champion Instrumentation. Shoulder Repair Made Simpler

Simple Interrupted Suture (using a tea towel)

Development of a Robotic Colonoscopic Manipulation System, Using Haptic Feedback Algorithm

HHS Public Access Author manuscript Gastrointest Endosc Clin N Am. Author manuscript; available in PMC 2016 August 18.

Methods for Haptic Feedback in Teleoperated Robotic Surgery

Suturing simplified. The first and only reusable, articulating, curved needle driver.

MIS TECHNOLOGY GUIDE READ PRODUCT INSERT THOROUGHLY BEFORE USE

White Paper: Technology and Clinical Overview of the Genii TouchSoft Coagulator monopolar probe

PARS Achilles Jig System

Simple Interrupted Suture (using a silicon skin pad)

HOLD FAST WITH EVERY PASS

Equine Laparoscopy Set by Mariën

Citation The Journal of surgical research (2.

PARS Achilles Jig System Surgical Technique

Minimally Invasive Suturing Devices

Arthroscopic Protector Meniscus Suturing Surgical Techniques

Product Pamphlet. Parcus Medical s Value Proposition Program is designed to reduce cost per case by:

Rotator Cuff Repair ICONN Answer PEEK Suture Anchor 4.75/5.5. Surgical Protocol by Geoffrey Connor, 4.75/5.5 MD of D1 Sports Medicine

WHEN IT COMES TO SUTURING, EXPERIENCE MATTERS.

ARTHROSCOPIC ROTATOR CUFF REPAIR SURGICAL TECHNIQUE. The following techniques are described by Vernon J. Cooley, M.D.

Tianjin Onehealth Medical Instruments. Onehealth Your surgical solutions partner

1 May Telesurgery with haptic sensation: The future of surgery. Michael Stark The New European Surgical Academy (NESA)

Objectives. xxx00.#####.ppt 5/10/17 9:42 AM

Using Simulation to Design Control Strategies for Robotic No-Scar Surgery

PATENT SPECIFICATION SYSTEM E FÜR M INIM AL INVASIVE G ASTR O IN TESTINALE VERFAHREN

LabraLock P for Labrum Repair, LabraFix System. The Reinforcement Technique Guide

Endoscopic Ultrasonography System

Small Occupancy Robotic Mechanisms for Endoscopic Surgery

Surgical Education Arrow project meeting

ENDOSCOPIC ULTRASOUND SYSTEMS

Introducing the LumiCoil Platinum Fiducial Marker. Features of LumiCoil Platinum Fiducial Markers. Expanding Innovation in EUS

Maneuverability Evaluation of a Surgical Robot for Single-Port Surgery

RAISING THE LEVEL OF PROTECTION IN YOUR ORS

Suture patterns. If you would like to submit an article for publication contact the editorial panel at

Dr. S.D. Gerber Double Row Method Surgical Technique

Autonomous Surgical Robotics

Cerclage Passer. For minimally invasive application of cerclage cables.

ERCP Papillotomes, balloons, guide wires and baskets.

Advancing the Art of Endoscopy

Prostar XL Percutaneous Vascular Surgical Device

EXpERIENCE THE power Of LIGHT

Chapter 1. Introduction

Medical Robotics. Part II: SURGICAL ROBOTICS

SMart wearable Robotic Teleoperated surgery

Magnified Examination of Small Colorectal Polyps Using a Prototype Electronic Endoscope: Preliminary Experience

Advancing the Art of Endoscopy

PUSH-PULL-PROPS. and accessories ROBUSTA-GAUKEL GMBH MOUNTING TECHNOLOGY &CO.KG

Designed to improve physician productivity and patient care.

Dental Sutures. Japanese quality for best results.

A New Needle Holder Facilitating Palm Grip Suturing

Suture anchors for VeterinarY use

Surgeon-Tool Force/Torque Signatures - Evaluation of Surgical Skills in Minimally Invasive Surgery

Cost savings without compromise

Cooperative Robotic Assistant for Laparoscopic Surgery: CoBRASurge

A free-extending two part cannulated screw that will elongate with growth. SURGICAL TECHNIQUE

Fundamental 7echniques Veterinary

Super Revo. Surgical Technique. Super Revo Shoulder Fixation System. The Ideal Fixation Device For Rotator Cuff Repair. Self-drilling, titanium anchor

Ethicon Open Stapling A solution for every staple line

Technique Guide. Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

Tyler Alignment & Calibration System For the Leksell Stereotactic Frame

Double Row Rotator Cuff Repair. Surgical Protocol by Frank Bonnarens, M.D.

Wide range in small dimensions

GET MORE. WITH LESS. Less sticking. 1, Less cleaning. 2, Less eschar buildup. 2, More benefits. LigaSure Maryland jaw device with nano-coated jaws

Double Row Rotator Cuff Repair. Surgical Protocol by Frank Bonnarens, M.D.

Haptic Feedback in Laparoscopic and Robotic Surgery

Application of Force Feedback in Robot Assisted Minimally Invasive Surgery

VERSALOK. Suture Anchor. Rotator Cuff Repair Surgical Technique

Wearable Haptic Feedback Actuators for Training in Robotic Surgery

Right Angle Screwdriver

Surgical robot simulation with BBZ console

Ethicon Open Stapling A solution for every staple line

ENDOSCOPIC ULTRASOUND SYSTEMS

Knotless SutureTak Instability Repair. Surgical Technique

5th Metatarsal Fracture System Surgical Technique

Measurements of the Level of Surgical Expertise Using Flight Path Analysis from da Vinci Robotic Surgical System

Towards robotic heart surgery: Introduction of autonomous procedures into an experimental surgical telemanipulator system

Superb Model Over 1,000 Stitch Functions

Haptic Feedback in Robot Assisted Minimal Invasive Surgery

Digital Compression Screw

The New Dimension in Imaging

Takeshi Omori, Jeong-Ho Moon, Kazuyoshi Yamamoto, Yoshitomo Yanagimoto, Keijirou Sugimura, Hiroshi Miyata, Masahiko Yano, Masato Sakon

The OPUS AutoCuff System for Rotator Cuff Repair

The Perfect Close. to your surgical procedure. PER F ORM ANC E through innovation

A Single-Port Robotic System for Transanal Micro-Surgery Design and Validation

The information contained in this document is intended for healthcare professionals only.

Integra. Capture Screw System SURGICAL TECHNIQUE

Ayuekanbe Atagabe. Physics 464(applied Optics) Winter Project Report. Fiber Optics in Medicine. March 11, 2003

OPHTHALMIC SURGICAL MODELS

Robots in the Field of Medicine

Evaluation of robotically controlled advanced endoscopic instruments

Suturing simplified. The first and only reusable, articulating, curved needle driver.

HUMAN Robot Cooperation Techniques in Surgery

Transcription:

Session IV UGS-IV: Emerging but rarely Used Treatment Options in Asia Endoscopic Suturing Devices Khek-Yu Ho, M.D. Department of Medicine, Yong Loo Lin School of Medicine, National University of Singapore, Singapore Introduction Suturing is a necessary step in any surgical operation. In flexible endoscopic surgery within and beyond the gastrointestinal tract, the task of suturing is more difficult due to limited working space and the non rigidity of the endoscope s shaft making it impossible to provide a stable base for surgical manoeuvres. Besides, tactile feel is lost in the flexible endoscopic approach. Unlike in laparoscopic procedures, performing suturing and tying of knots endoscopically is a very tedious process requiring high manual dexterity and excellent hand eye coordination. Endoscopic suturing devices currently available for use in gastrointestinal surgery are too complex for the average endoscopist to handle, requiring much training with long learning curves. While most of the earlier endoscopic suturing devices developed for upper gastrointestinal tract uses were aimed for procedures such as fundoplication, recent developments in natural orifice translumenal endoscopic surgery (NOTES) have prompted designs suitable for transluminal surgical applications. In the absence of better visceral closure devices, most early trials in NOTES have resorted to the use of endoscopic clips or tissue anchors to reinforce closures of visceral perforations. Better, more dextrous and yet easy to handle endoscopic suturing devices are awaited. Development of endoscopic suturing devices to date In contrast to earlier suturing/stapling devices designed for the treatment of gastroesophageal reflux disease and obesity, innovations of endoscopic suturing devices specifically for use in flexible endoscopic surgery had only been in progress for at most a decade. In fact, clinical trials of some of these endoscopic suturing devices debuted only in the mid 2000s, which was followed by commercialisation of the OverStitch developed by Apollo Endosurgery, Inc., Austin, TX, USA, and the InScope Tissue Apposition System developed by Ethicon Endo surgery, Cincinnati, OH, USA, for use in various types of flexible endoscopic surgery. Over the recent years, a few other newer suturing devices/systems have emerged, with most being in pre clinical evaluation stage. 1. Commercially available endoscopic suturing devices functions and applications A limited number of flexible endoscopic surgery suturing systems have been cleared by the US Food and Drug Administration (FDA) agency for clinical applications. Amongst the better known ones are the OverStitch su- 122 IDEN 2014

UGS-IV: Emerging but rarely Used Treatment Options in Asia turing device, the InScope Tissue Apposition System, and the g Prox Tissue Approximation Device (USGI Medical, Inc., United States), which will be described in the following paragraphs. The OverStitch suturing device is a disposable, single use suturing device designed to be front loaded onto a double channel endoscope for deployment. It employs a lateral needle passing mechanism and allows continuous or interrupted stitches to be made. Cinching capability is incorporated into the system to provide fast, secure closure of perforation without the need to tie complex surgical knots. The OverStitch can deliver multiple stitches in one single endoscopic insertion to provide secure approximation of tissue. Its curved needle design allows operator to better control the depth of suture placement. Cinching and reloading of needle can be done without the need to remove the endoscope from the stomach. Designed for single handed system control, it requires only one operator to handle the system and is suitable for use in a wide range of endoscopic application, including endoluminal tissue apposition and endoscopic closure of submucosal or full thickness mural defects. The OverStitch has been successfully applied to perform gastric full thickness suture during endoscopic mucosal resection, 1 suturing of gastric full thickness resection, 2 suturing of defects in treat and resect colonic procedures, 3 suturing of large defects in the stomach and colon left after endoscopic mucosal dissection, 4 suturing of gastric fistulas, 5 and suturing of the mucosal entry site in full novel submucosal tunnelling procedures. 6 The OverStitch has an edge over other existing suturing devices in that it is also effective for closure of larger defects. The downside is that orientation of the curved needle requires much skill and the assistance of an endoscopic grasper is required during operation. It is however generally considered complex to use and more appropriately apply for use in bigger lumens such as in the stomach rather than smaller lumens, although recent trials conducted in human have demonstrated the feasibility of its use in some colonic procedures. 3,4 The InScope Tissue Apposition System is designed for endoscopic placement of sutures and approximation of soft tissue. The system uses an endoscopic hollow bore needle and non absorbable, synthetic, polypropylene suture, and works by sequentially deploying threaded T tag through the soft tissue on each side of the gastrointestinal defect to be sewn. Suture position is maintained by means of a metal tissue anchor attached to the distal end of each suture strand. Threaded T tags placed on either side of the defect are then cinched using a component called the Knotting Element. The InScope Tissue Apposition System can be used for endoscopic treatment of a variety of defects, including ulcers and perforations. One shortcoming in the design of the system is that the operator cannot visualize the deployment of T tag from the extra luminal side of the defect, thus posing a risk of inadvertent injury to surrounding tissue or blood vessels during deployment of the tags. Preclinical studies showed the feasibility of making leak proof endoluminal closure of a 4 cm long colon perforation in 3 of 4 cases tried. 7 Subsequently, trials conducted in human demonstrated safe closure of defects by the InScope Tissue Apposition System during endoscopic polypectomy of polyps which were otherwise deemed unresectable. 8 The system is now being further developed by Ethicon Endo Surgery as part of a NOTES Toolbox specifically for use in flexible endoscopic transluminal surgery applications. The flexible g Prox Tissue Approximation Device is a multi function instrument that works on the TransPort multitasking endoscopic platform, both manufactured by USGI Medical, Inc., United States. The g Prox Tissue Approximation Device, designed to suit single operator handling, is equipped with independent torqueing capacity. To do suturing, the device is first deployed through the lumen of the TransPort endoscopy platform. Once the device is deployed at the endoscope s tip, it acts as a needle driver that delivers its propriety IDEN 2014 123

IDEN 2014 Snowshoe Suture Anchors which are preloaded into the g Cath EZ Delivery Catheter inserted into the g Prox device. Once anchors are used up, reloading of the anchors can be performed without the need to withdraw the instrument. In contrast to the InScope Tissue Apposition System, anchor placement here is made via an off axis needle. The suture passage is thus off tangential, permitting thus full visualization of the anchor placement. This is an advantage as it mitigates the risk of inadvertent injury to adjacent tissue as may happen in blinded placement. The system is so designed that the operator can singularly control the tension of the tissue anchors and adjusts it to tighten the closure. Knot strength is quite easily achieved. The g Prox Tissue Approximation Device also has the additional functionality of acting as a tissue grasper, providing a robust grasping function and tissue manipulation capability. Pre clinical trials in animals have demonstrated excellent full thickness suturing using the system. 9 The system which is already CE marked for marketing in Europe, is now being developed as part of USGI Medical's Incisionless Operating Platform, a complete multitasking endosurgical platform designed to support the performance of intricate endoscopic endoluminal, as well as transluminal surgical procedures such as those in NOTES. 2. Emerging endoscopic suturing devices Despite the availability of various endoscopic suturing devices that can do suturing tasks as described above, there is still no perfect technological solution for consistent and reliable closures of larger mural defects such as those deliberately made in NOTES. Current commercially available systems have been found by many users to be technically complex, with some reporting finding it difficult to mount the devices correctly on the endoscope. The complexity of the applications, long learning curve, lack of equipment dexterity, and inadequate tissue closure strength are persistent issues that continue to spur innovations for better solution. Recent development of NOTES has prompted renewed interest in the development of easily deployable endoscopic suturing devices that can make sutures that are as strong, secured and reliable as hand sewn ones. Several new and promising innovations are now in proof of concept or pre clinical evaluation stage. Amongst them are: (i) a novel Korean designed prototype device featuring the capability of making successive sutures, and aptly named the successive suturing device, 10,11 and (ii) two prototypes of an interesting Japanese designed suturing system, the double arm bar suturing system and the triple arm bar suturing system. 12,13 Pre clinical evaluations of the novel successive suturing device were recently reported by Song et al (2013). The successive suturing device appears to be quite simple by construct, with three major components a needle, teel plastic tubing that holds major parts of the system, a handle plus a suction cap. 10 The protective tubing has an external diameter of 3.2 mm, making it small enough to pass through the accessory channel of a standard therapeutic endoscope. The tubing encases the main components of the device, including the transfer tube for the needle, suturing thread and accompanying biodegradable trapezoidal shaped bead which is used as anchor. The handle drives the movement between the components. To perform the suturing of a deliberate or iatrogenic defect in the wall of the stomach or gastrointestinal tract, the entire system is deployed through the accessory channel of the endoscope, and the needle is pushed through the gastric or intestinal wall. A stitch bead is deployed from the needle and it anchors a stitch on the outer surface of the wall while the needle is pulled back from inside the lumen. As beads are anchored on both sides of the incision, pulling the stitch tightens and securely closes the incision. Recently, Song et al (2013) reported their validation of the suturing efficacy of the prototypic device on Erlangen porcine stomach models, in which they compared the strength and reproduci- 124 IDEN 2014

UGS-IV: Emerging but rarely Used Treatment Options in Asia bility of incisions sutured by the device to that of incision sutured by hand or closed by endoclips. Deliberate incisions of 2 3 mm length were made on the anterior lower body of 30 porcine stomachs. These 30 incisions were then closed using the novel suturing device, by hand suturing or by endoclips, 10 incisions for each method of suturing. The experimental results showed that the stomachs sutured by the successive suturing device exhibited significantly higher air leakage pressure than those closed by Endoclips (P<0.05), but lower than those closed by hand suturing (P<0.05). Although the bursting pressure of device sutured stomachs was significantly smaller than that of hand sutured stomachs, it was similar to that of Endoclip closed stomachs. The suturing device took about 1 minute to complete a stitch. The experimental trials of two prototypes of a novel Japanese designed endoscopic suturing system were recently reported by Mori et al, (2013; 2014). The prototypes were named the double arm bar suturing system and triple arm bar suturing system. Although experiments are still preliminary at this stage, results indicate good potential for the novel innovations to make it to clinical applications. The triple arm bar suturing system consists of three main arms: (i) a guide needle arm, (ii) a stopper arm at the tip of the device for receiving the puncture needle arm, and (iii) a puncture needle arm. In contrast, the double arm bar suturing system has only two arms, one arm holding the puncture needle and a small hook, and the other holding the suture. In 2013, Mori et al reported the use of the triple arm bar suturing system to close twenty 5 cm incisions in resected swine stomachs. Comparing it to hand sewn stitches, they found similar maximum pulling force durability between full thickness stitches made by triple arm bar suturing system and stitches made by hand (P = 0.335). In another study, Mori et al (2014) tested the reliability of the double arm bar suturing system, and the feasibility of using it to perform endoscopic full thickness resection. Full thickness resections of 40 mm diameter were carried out on 30 swine stomachs. Based on resistance to air leak tests, they found no significant difference between hand sewn sutures and sutures made by the double arm bar suturing system (P = 0.542), indicating that the strength of sutures made by the double arm bar suturing system was as good as hand sewn ones. Whether it is single stitch and multiple stitch sutures, the sutures produced by the above prototypic suturing devices were as strong as simple, interrupted handmade sutures. 3. The Future robotic enhancement of endoscopic suturing systems Currently available endoscopic suturing devices enables suturing to be performed endoscopically but they still have functional limitations, especially when performing in confines of smaller working space, and when dealing with bigger perforations. Primarily, all these systems are mechanically driven and thus lack the motion range and functional dexterity for fast, efficient and safe operation in complex procedures such as those in NOTES. Although emerging innovations are increasingly aimed at providing better articulation in instrumental mobility, with all mechanical systems, there is limitation to the range of surgical movement of tools. Moreover, poor perception of depth with current 2D endoscopic video imaging and the lack of tactile sensation pose hurdles in the management of the orientation of tools and judgement of appropriate amount of force to apply, risking injury to tissue. To mitigate these technical challenges, the incorporation of robotics into the control of suturing and knotting function is an attractive option. Recently, the developer of the MASTER (Master And Slave Transluminal Endoscopic Robot) in Singapore demonstrated the practicality of this idea in their first ex vivo trial on robotics enabled suturing and knot tying. They demonstrated the feasibility of performing endoscopic suturing and knot tying using commercial suturing kit with robotics enablement through the MASTER, a sta- IDEN 2014 125

IDEN 2014 Fig. 1. Robotics enabled suturing of a non perforating cut on the wall of the rectum of a pig using MASTER and Ethicon W525 suture set. Fig. 2. Robotics enabled suturing of a non perforating cut on a phantom model using MASTER and Covidien V Loc wound closure device. ble haptics enabled robotic endosurgical platform which had previously been evaluated for its performance of various endolumenal and translumenal endoscopic surgical procedures, both in animals 14,15 and in human. 16 With the assistance of the MASTER, equipped with a customized needle holder/driver with articulating jaws and a pair of graspers, suturing and knot tying was successfully performed on a phantom using a V Loc wound closure device (Covidien, Mansfield, MA, USA) (Fig. 1) and on a non perforating cut created in the rectum of a live pig using an Ethicon W525 suture set (PC 3; 16mm, 3/8 Circle Conventional Cutting) (Fig. 2) (Presentation at DDW 2014, Chicago, USA). The MASTER development team has planned to make its own customized MASTER adaptable suturing/knot tying slave effectors for truly intuitive performance of endoscopic suturing. This is part of its efforts to develop a dedicated robotics endosurgical toolbox for use on the MASTER endosurgical platform. When ready, the proposed dextrous robotics enhanced MASTER suturing/knot tying system is anticipated to contribute much to easier and safer endoscopic suturing, and thereby accelerate the clinical development of NOTES. Conclusion Incision closure is one of the most challenging tasks in endoscopic surgery such as NOTES. Current mechanical endoscopic suturing devices lack dexterity and suffer numerous functional limitations. While ongoing innovations of better mechanical endoscopic suturing devices are anticipated to fill in some of the unmet demands of reliable, reproducible, and secured suturing in endoscopic surgical applications, the ultimate solution for adequately dextrous, safe and efficient endoscopic suturing could lie in the incorporation of robotics into future suturing systems. 126 IDEN 2014

UGS-IV: Emerging but rarely Used Treatment Options in Asia References 1. von Renteln D, Schmidt A, Riecken B, Caca K. Gastric full thickness suturing during EMR and for treatment of gastric wall defects (with video). Gastrointest Endosc 2008;67(4):738 44. 2. Chiu PW, Phee SJ, Wang Z, et al. Feasibility of full thickness gastric resection using master and slave transluminal endoscopic robot and closure by Overstitch: a preclinical study. Surg Endosc 2014;28(1):319 24. 3. Pauli EM, Delaney CP, Champagne B, Stein S, Marks JM. Safety and effectiveness of an endoscopic suturing device in a human colonic treat and resect model. Surg Innov 2013;20(6):594 9. 4. Kantsevoy SV, Bitner M, Mitrakov AA, Thuluvath PJ. Endoscopic suturing closure of large mucosal defects after endoscopic submucosal dissection is technically feasible, fast, and eliminates the need for hospitalization (with videos). Gastrointest Endosc 2014;79(3):503 7. 5. Bonin EA, Wong Kee Song LM, Gostout ZS, Bingener J, Gostout CJ. Closure of a persistent esophagopleural fistula assisted by a novel endoscopic suturing system. Endoscopy 2012;44 Suppl 2 UCTN:E8 9. 6. Rajan E, Gostout CJ, Aimore Bonin E, et al. Endoscopic full thickness biopsy of the gastric wall with defect closure by using an endoscopic suturing device: survival porcine study. Gastrointest Endosc 2012;76(5):1014 9 7. Raju GS, Shibukawa G, Ahmed I, Brining D, et al. Endoluminal suturing may overcome the limitations of clip closure of a gaping wide colon perforation (with videos). Gastrointest Endosc 2007;65(6):906 11. 8. Delaney CP, Champagne BJ, Marks JM, Sanuk L, Ermlich B, Chak A. Tissue apposition system: new technology to minimize surgery for endoscopically unresectable colonic polyps. Surg Endosc 2010;24(12):3113 8. 9. Mellinger JD, MacFadyen BV, Kozarek RA, Soper ND, Birkett DH, Swanstrom LL. Initial experience with a novel endoscopic device allowing intragastric manipulation and plication. Surg Endosc.2007;21(6):1002 5. 10. Bae, K, Jung, K, Chu, B, et al. Development of a novel successive suturing instrument for an endoscope using beads and a side suction cap. Int. J. Precis. Eng. Manuf 2009;10(2):97 103. 11. Song Y, Choi HS, Kim K, et al. A simple novel endoscopic successive suture device: a validation study for closure strength and reproducibility. Endoscopy 2013;45(8):655 60. 12. Mori H, Kobara H, Rafiq K, Nishiyama et al. New flexible endoscopic full thickness suturing device: a triple arm bar suturing system. Endoscopy 2013;45(8):649 54. 13. Mori H, Kobara H, Fujihara S, et al. Feasibility of pure EFTR using an innovative new endoscopic suturing device: the Doublearm bar Suturing System (with video). Surg Endosc. 2014;28(2):683 90. 14. Phee SJ, Ho KY, Lomanto D, Low SC, Huynh VA, Kencana AP, Yang K, Sun ZL, Chung SC. Natural orifice transgastric endoscopic wedge hepatic resection in an experimental model using an intuitively controlled master and slave transluminal endoscopic robot (MASTER). Surg Endosc 2010 Sep;24(9):2293 8. Epub 2010;23. 15. Z. Wang, S.J. Phee, D. Lomanto, R. Goel, P. Rebala, Z.L. Sun et al., "Endoscopic submucosal dissection of gastric lesions by using a master and slave transluminal endoscopic robot: an animal survival study," Endoscopy Jul;44(7):690 4, 2012. 16. Phee SJ, Reddy N, Chiu PW, et al. Robot assisted endoscopic submucosal dissection is effective in treating patients with earlystage gastric neoplasia. Clin Gastroenterol Hepatol 2012;10(10):1117 21. IDEN 2014 127