Valve amplifier for proportional valves. Type VT-SSPA1-1 (5, 50, 100, 150) Features. Contents. RE Edition: Replaces:

Similar documents
Valve amplifier for proportional valves. Type VT-MSPA2-1. Contents. Features. RE Edition: Replaces:

Plug-in amplifier. Table of contents. Features. RE 30264/07.12 Replaces: Type VT-SSPA1. Component series 2X 1/8

Valve amplifier for proportional valves with electrical position feedback

Booster amplifier. Table of contents. Features. RE 30260/04.12 Replaces: Type VT-MSFA1. Component series 1X 1/6

Valve amplifier for high-response valves. Type VT-VRRA X/V0/2STV, VT-VRRA X/V0/PO-IS. Contents. Features

Electric amplifiers. Table of contents. Features. RE 30052/02.12 Replaces: Type VT-VRPA X/V0/... Component series 1X 1/6

Valve amplifier for proportional pressure valves

Valve amplifier for proportional directional valves and proportional pressure valves. Type VT-VSPA2-1. Features. Contents

Electric amplifiers. Table of contents. Features. RE 30054/03.12 Replaces: Type VT-VRPA X/...-RTP. Component series 1X 1/6

Valve amplifier for proportional directional valves. Type VT-VRPA2. Features. Contents. RE Edition: Replaces: 07.05

Electric amplifiers. Table of contents. Features. RE 30048/08.12 Replaces: Type VT-VRPA X/V0/RTP. Component series 1X 1/6

Valve amplifier for proportional pressure valves

Analog amplifier. RE 29926/10.06 Replaces: Type VT Component Series 3X

Electric amplifier for proportional cartridge throttle valves

Electric amplifier for flow control with proportional

Electric amplifiers. List of contents. Features. RE 30052/08.05 Replaces: Type VT-VRPA1. Unit series 1X 1/6

p/q closed-loop control amplifier

4/3 proportional directional valve with integrated digital electronics and field bus interface (IFB-P) Type 4WREF. Features.

Analogue amplifier. Features. Table of contents. RE 29980/09.05 Replaces: Type VT-SR2. Series 1X 1/6

High-response valve with integrated digital axis controller (IAC-R) and field bus interface

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

4/3 proportional directional valve direct operated, with integrated electronics

Analog amplifier RA. RE Edition: Replaces:

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback

Electronic amplifier for the control of proportional valves without position control Model VT 3024, Series 3X H/A 4149/94 VT X

Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X

Analogue amplifier modules for 4/3 and 4/2 proportional directional valves 4WRE

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Service case with test unit for servo and proportional valves with integral electronics (OBE)

Electric amplifiers. Table of contents. Features RA 30052/ Model VT-VRPA1. Series 1X 1/6

DENISON HYDRAULICS Proportional Pressure Control Valves

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces:

RT-5005/5006/5007/5008

Directional control valve, direct operated, with integrated digital axis controller (IAC-Multi-Ethernet) Type 4WRPDH. Features.

External control electronics for the SYDFE1 control of the A10VSO axial piston variable displacement pump

Sensor technologies Proximity sensors Series ST9. Brochure

Controller. 1 Proportional amplifier module ESSK 103. ESSK 103 and ELSK Description. 1.2 Application examples. 1.

RA / /6. Replaces: Table of contents RA /06.98

Technical Documentation

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

External control electronics for the SYDEF1 adjustment of the A10VSO axial piston pump

EPA-M*** POWER AMPLIFIER FOR OPEN LOOP PROPORTIONAL VALVES SERIES 20

Directional valves Electrically operated Series 563, 565, 567. Brochure

4/3-way fast response valve Type 4WRGE

Fuse, external A 6A, medium time lag. Power consumption W min 20 - max 60 (see paragraph 5.2) Output current A maximum 4.5 (see paragraph 5.

ELECTRONIC REGULATOR FOR OPEN LOOP

Drive electronics pq11

Drive Electronics pq11

Proportional amplifier type EV1M3

Directional valves Coils Series CO1. Brochure

Proportional amplifier type EV1M3

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

External control electronics for the SYDFE1 control of A10VSO axial piston pumps Analogue amplifier, configurable

4-Way Servo Valve Model 4 WS. 2 E , (Series 2X) with Mounting Pattern to DIN or CETOP RP 115 H PSI (315 bar) H/A 3012 H/A 3013

Digital amplifier for proportional valves PEM XD

Directional control valve, direct operated, with integrated digital axis controller (IAC Multi Ethernet) Type 4WRPDH. Features.

Speed sensor DSA series 12

External control electronics for the SYDFE1 control of the A10VSO axial piston variable displacement pump

Proportional directional valves

12 30 ripple included external fuse 3,0 A Current consumption A 1,0 2,6 depending from solenoid current. V ma. V ma. Output current A 1,0-1,6-2,6

Digital Function Generator

DIN (NFPA/ISO/CETOP) NG6 (3) NG10

Digital axis control HNC100

Proportional amplifier type EV22K5

Accessories Power Amplifiers

Digital axis control. Table of contents. RE 30139/08.12 Replaces: Type VT-HNC100. Component series 3X 1/20

MDSD (Series 2X) Mobile Dual Solenoid Driver

Electronic plugs for valves MSE

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

Mobile dual solenoid driver

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Electronic amplifier type EV1D

Digital electronic TEB/LEB drivers integral-to-valve format, for proportional valves with one or two spool position transducers

Technical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2

Rudder or propeller angular position transmitter KINAX WT720

Direct Operated Proportional DC Valve Series D1FP

Analog Amplifier RA. RE B/ Replaces: English. Instruction manual

Servo Amplifier 4-Quadrant PWM for Brushless DC-Servomotors

Frequency converter. Frequency Converter Fe

NOVOTURN Multiturn Sensor non-contacting. Series RSM-2800

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany

Proportional Directional Control Valves Size 6

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD-F18 Hydraulic-Series. Key-Features:

Power consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2

Coil. Coil L 12 VDC 135 C 18 W 7.7 Ω M M 24 VDC 135 C 18 W 31 Ω M AMP Junior (AJ variant) Coil

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

Sensor technologies Distance measuring sensors Series SM6-AL. Brochure

Continental Hydraulics Installation Manual CEM-RA-A

Proportional Directional Control Valves Nominal sizes 16 and 25

Absolute Encoders Multiturn

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

Proportional Directional Control Valves Series D1FB. General Description. Features. D1FB*3 OBE Spool/Body Design. D1FB*0 OBE Spool/Sleeve Design

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

EMA Series, EMC Series

Amplifier / controller electronics

Continental Hydraulics Installation Manual CEM-PA-A

Transcription:

Valve amplifier for proportional valves Type VT-SSPA- (5, 50, 00, 50) RE 306 Edition: 05-03 Replaces: 04-07 Component series X Analog, connector design Suitable for controlling solenoid-actuated pressure and directional valves without position control (see page ) H707+7645 Features Proportional command value/current characteristic curve for command values between 0 and 00 % Regulated adjustable maximum current for command values greater than approx. 0 % (for differential input only) Differential input Separate up/down ramp generator Zero potentiometer / pilot current Command value attenuator / maximum current Dither frequency potentiometer 4 V operating voltage Contents Features Ordering code Applications 3 Function 4 Block diagram 4 Characteristic curve 5 Technical data 5 Electrical connection 6 Adjustment elements / dimensions 7 Project planning / maintenance instructions / additional information 8 Further information 8 RE 306, edition: 05-03, Bosch Rexroth AG

/8 VT-SSPA-(5, 50, 00, 50) Valve amplifier Ordering code 0 0 03 04 05 06 07 VT-SSPA X / / 0 4 / alve amplifier for proportional valves, analog, connector design VT-SSPA 0 For DBET / DRE / DBEM...7x For KBPS...8 5 niversal,.5 A 50 For KKDSR 00 niversal, 0.8 A 50 03 Component series 0 to 9 (0 to 9: unchanged technical data and pin assignment) X 04 Version: Standard V0 Version: ramp time: 0 ms to s (only for variant VT-SSPA-50-X) V00 05 Voltage input 0 06 4 V operating voltage 4 07 Cable gland PG no code Conector, 4-pole, Mx ) K4 ) Contact box, separate order, see accessories Type overview Type Mat. no. B I rated f with I rated Command value For valve Solenoid VT-SSPA--X/V0/0-4 R900779643 4 V.6 A 340 Hz 0.../4 V DBET / DRE / DBEM...7x 5.5 Ω VT-SSPA--X/V0/0-4/K4 R9038534 4 V.6 A 340 Hz 0.../4 V DBET / DRE / DBEM...7x 5.5 Ω VT-SSPA-5-X/V0/0-4 R900433 4 V. A 00 Hz 0.../4 V KBPS...8 4.77 Ω VT-SSPA-5-X/V0/0-4/K4 R9038530 4 V. A 00 Hz 0.../4 V KBPS...8 4.77 Ω VT-SSPA-50-X/V0/0-4 R9000544 4 V.5 A 305 Hz 0.../4 V universal > Ω VT-SSPA-50-X/V00/0-4 R9033678 4 V.5 A 305 Hz 0.../4 V universal > Ω VT-SSPA-50-X/V0/0-4/K4 R903853 4 V.5 A 305 Hz 0.../4 V universal > Ω VT-SSPA-00-X/V0/0-4 R900306 4 V. A 50 Hz 0.../4 V KKDSR 7. Ω VT-SSPA-00-X/V0/0-4/K4 R903858 4 V. A 50 Hz 0.../4 V KKDSR 7. Ω VT-SSPA-50-X/V0/0-4 R9004644 4 V 0.8 A 50 Hz ) 0... universal 9.5 Ω VT-SSPA-50-X/V0/0-4/K4 R906378 4 V 0.8 A 50 Hz ) 0... universal 9.5 Ω ) With a solenoid resistance of R = 9.5 Ω and a solenoid current of I = 00 ma Bosch Rexroth AG, RE 306, edition: 05-03

Valve amplifier VT-SSPA-(5, 50, 00, 50) 3/8 Ordering code (continued) Accessories for type.../k4 Description Designation Mat. no. Assembled cable with straight mating connector CABLE SET VT-SSPA-X/M//V00 R904656 Ø5 44,5 5000 ±75 0 Cable sheath: PVC, black cable sheath Ø: 6.4 mm wire cross-section: 4 x 0.75 mm Cable and mating connector shielded Connection see page 6 Assembled cable with angular mating connector CABLE SET VT-SSPA-X/M//V00 R90465 3 Cable sheath: PVC, black 0 cable sheath Ø: 6.4 mm wire cross-section: 4 x 0.75 mm Cable and mating connector shielded Ø5 Connection see page 6 39 5000 ±75 Applications -conductor technology (only with differential input) Switching application with fixed flow control Ramp function upon switch-on The input is bridged with supply voltage (+ B ) in the connector, the IN input is bridged with supply voltage () in the connector. The maximum current must generally be adjusted according to the solenoid information using potentiometer G. The ramp time ramp up (t <) can be set within the range of t min to 5 s. B = 4 V PE + B 0uF 0V t< t> f Z G I 3-conductor technology (only with differential input) Switching application with fixed flow control Switching with low control power Ramp function can be adjusted separately when switching on and off the control voltage The input is connected to the control voltage (s = 4 V), the input is bridged with supply voltage () in the connector. The maximum current must generally be adjusted according to the solenoid information using potentiometer G. When switched off ( = or = open) a pilot current can be set at Z. This serves to reduce the switchon delay, particularly with ramp. If required, this value can be adjusted between approx. 0 ma and approx. 5% of the rated current. The ramp times ramp up (t <) and ramp down (t >) can be set within the range of t min to 5 s. S = 4 V B = 4 V PE + B 0uF 0V t< t> f Z G I RE 306, edition: 05-03, Bosch Rexroth AG

4/8 VT-SSPA-(5, 50, 00, 50) Valve amplifier Applications (continued) 4-conductor technology The input is connected to the control signal (s = 0... /4 V), the input is connected to the reference potential of the control voltage. Pilot current and maximum current are set using potentiometers Z and G prior to commissioning. The current can now be proportionally adjusted according to the control voltage between the set pilot current and the set maximum current. The pilot current can be set in the range of approx. 0 ma to approx. 5% of the rated current, the maximum current can be set in the range of 0 to I max (see technical data page 5). 0... / 4 V 4 V PE + B 0uF 0V t< t> f Z G I Function The plug-in amplifier is suitable for installation on a valve connection base according to EN 7530-803. By turning the plug insert and the electronics in the housing, the plug-in amplifier can be mounted on the solenoid in 90 increments. Command value presetting The command value range is between 0 and B. In the command value range 0... the solenoid current is proportional to the command value. Starting with a command value of V up to B the solenoid current is almost constant according to the I max setting (switching application). Ramp generator The ramp generator (5) limits the rise of the control output. The up and down ramp times can be adjusted separately. In switching applications, the ramps can be used to dampen the switch-on and switch-off impulse. (When switching off only with 3-conductor connection, i.e. switching signal and supply are connected separately.) This behavior also depends on the valve and solenoid type. The downstream command value attenuator (4) has no influence on the ramp time. Characteristic curve p to a command value of approx. 0% the transfer characteristic curve rises linearly. The zero point can be corrected using potentiometer Z, the maximum value can be corrected using potentiometer G. Power output stage Output stage (7) is freely clocking. The clock frequency depends on the current level, the operating voltage and the impedance of the controlled solenoid. The clock frequency can be re-adjusted using potentiometer f. The current output stage generates a regulated current signal according to the control output provided by the summing device (3). If the clock frequency is too high, the valve hysteresis is increased. If the clock frequency is too low, the noise level of the hydraulic system is increased. ( )= Assignment to the block diagram Block diagram () Internal voltage adjustment () Command value input (3) Zero point potentiometer Z / pilot current I (IN = 0%) (4) Command value attenuator G / maximum current I (IN = 00%) (5) Ramp time potentiometers t < and t > (6) Frequency range correction f (7) Power output stage Command value 4 V () + B 0uF 0V t< t> (5) () f Z (3) (4) G I (7) (6) PE Bosch Rexroth AG, RE 306, edition: 05-03

Valve amplifier VT-SSPA-(5, 50, 00, 50) 5/8 Characteristic curve Actual value I max I rated (00%) Factory setting Setting range Maximum command value = 35 V Notice: Depending on the type, the pilot current can also be 0. I B (0%) 0 % 00% approx. 0% B Command value Technical data (For applications outside these parameters, please consult us!) Type VT-SSPA- VT-SSPA-5 VT-SSPA-5T-SSPA-0T-SSPA-50 4 V operating voltage B 4 V u(t) max 35 V u(t) min 8 V Maximum cable inductance ) L max 00 µh Current and power consumption I / A <.7 <.7 <.6 <.7 <. (dependent on solenoid data) P max / VA < 40 < 40 < 60 < 40 < 30 Recommended pre-fuse I / A ; time-lag ; time-lag 3.5; time-lag ; time-lag.5; time-lag Minimum coil inductivity L min / mh 5 5 0 5 5 Pilot current (setting range) I B / ma 0...300 0...300 0...350 0...50 0...00 Pilot current (factory setting) I B / ma 00 0 00 0 00 Rated current (factory setting) I / A.6..5. 0.8 Maximum current (setting range) I max / A I B...7 I B...8 I B...6 I B...7 I B...0.8 Clock frequency at I max f / Hz 340 00 305 50 50 ) Command value input (voltage) Proportional range 0... Switching range V... B Resistance R 0 kω Ramp time (setting range) Variant V0 t 00 ms...5 s 60 ms...5 s Variant V00 t 0 ms... s Type of connection (cable gland) 4 screw terminals Cable diameter 4.5 mm Type of connection (M connector) Connector, 4-pole, Mx, A codification Type of connection (solenoid) Base according to EN 7530-803 Number of poles (solenoid) + PE Dimensions see page 7 Type of mounting M3 x 40 mm Admissible operating temperature range (amplifier with cable gland) C 5 +70 5 +70 5 +60 5 +70 5 +70 Admissible operating temperature range (amplifier with M connector) C 5 +70 5 +70 5 +50 5 +70 5 +70 Storage temperature range C 5 +85 Protection class according to EN 6059 IP65 with mounted cable/mounted mating connector Weight m 0.5 kg ) sually corresponds to a cable length < 00 m ) With a solenoid resistance of R = 9.5 Ω and a solenoid current of I = 00 ma RE 306, edition: 05-03, Bosch Rexroth AG

6/8 VT-SSPA-(5, 50, 00, 50) Valve amplifier Electrical connection Terminal / pin +B / Operating voltage B 4 V Terminal / pin / / 3 ground / 4 Command value input 4 V; 0... Reference potential for the command value Terminal connection Risk of malfunctions in case of EMC/ESD interference on the connection cable Do not route command value connection lines through this section! The connection for the protective earthing conductor is accessible after the electronic printed-circuit board has been removed. +B Connection cross-section: 4 x 0.75 mm shielded or 5 x 0.5 mm shielded (connect shield in control cabinet) For VT-SSPA-50: 4 x.5 mm shielded (connect shield in control cabinet) Cable diameter: 4.5 mm M plug-in connector port Connector on amplifier 4 3 Mating connector and wire colors with pre-assembled cable set Please order the cable set separately, see page 3 4 3 4 3 BN brown WH white BK black B blue Shield +B The connection for the protective earthing conductor is not provided Connection cross-section: 4 x 0.75 mm shielded (connect shield in control cabinet) Bosch Rexroth AG, RE 306, edition: 05-03

Valve amplifier VT-SSPA-(5, 50, 00, 50) 7/8 Adjustment elements / dimensions (dimensions in mm) Cable gland PG Connector Mx Top view on open housing: G Command value attenuator / maximum current Z Zero point potentiometer / pilot current t < Ramp time up t > Ramp time down f Frequency range RE 306, edition: 05-03, Bosch Rexroth AG

8/8 VT-SSPA-(5, 50, 00, 50) Valve amplifier Project planning / maintenance instructions / additional information The plug insert can be rotated in 90 steps in compliance with ESD protective measures. The plug-in amplifier may only be wired when de-energized. Do not lay lines close to power cables! The distance to aerial lines, radios, and radar systems has to be m at least. To set the potentiometers and to check the current values, use the measuring adapter and measure the currents in a potential-free manner. The specified maximum solenoid currents must not be exceeded. Do not use solenoids with integrated free-wheeling diodes. The supply voltage is to be protected by means of a fuse see Technical data. Notice: The solenoids are controlled with a clocked voltage. The solenoid voltage impulse level corresponds to the applied operating voltage (+ B ). Solenoids with integrated EMC protection circuit may only be used if the response voltage of the protection circuit - both, for positive and negative voltage - is greater than the actual operating voltage. The specifications of the valve manufacturers are to be observed. Notice: With a strongly fluctuating operating voltage, it may in the individual case be necessary to use an external smoothing capacitor with a capacity of approx. 470 µf to 00 µf. The line length should not exceed 50 m. For longer lines, a capacitor with C 00 µf has to be connected between B and. The line between capacitor and plug-in amplifier must not be longer than 50 m. Recommendation: Capacitor module VT 0 (see data sheet 30750); sufficient for up to 5 plug-in amplifiers Further information Notice: For general information regarding safety, assembly and commissioning see operation manual: 0760-B Electronics for industrial applications Bosch Rexroth AG Hydraulics Zum Eisengießer 9786 Lohr am Main, Germany Phone +49 (0) 93 5 / 8-0 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without consent of Bosch Rexroth AG. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging. Bosch Rexroth AG, RE 306, edition: 05-03