Chiko Flat Pitched roof installation roof installation Guide Gui

Similar documents
Mounting Systems. Tilt Kit Installation Guide. Tilt Kit Installation Guide. Table of Contents

Unirac Installation Manual

Code-Compliant Planning and Installation Complying with AS/NZS1170.2:2011 ADMT

XIAMEN FENGWEI ENERGY TECHNOLOGY CO., LTD. GRACE SOLAR ROOF MOUNTING SYSTEM INSTALLATION Manual

SolarMount-I INSTALLATION MANUAL

Unirac Flat Flashing INSTALLATION MANUAL

PV-ezRack Solar Terrace II-A Installation guide

PV-ezRack PostMount 1-A Installation Guide

INSTALLATION MANUAL v. 1.0

EzQuikTM. MicroSolar System EzQuik TM Aluminum Solar PV Module Mounting System. Code-Compliant Installation Manual V1011 (AS/NZ1170) Model 2012

orientation Conergy SunTop Instructions for professional installation

MRac Ground Terrace VI Installation Guide (with Ground Screw)

Installation Manual XRL Solar Rail System

MRac Solar Carport System Installation Guide

SunPower Installation Manual

Installation Manual Tilt Leg

Single Arm Pole Mount. Installation Manual Edition v1.01. For models: UNI-SA/14 UNI-SA/21.5 UNI-SA/26 UNI-SA01-MAN

Adjustable Racking System Installation Guide

Installation Manual. Tamarack Solar Products. Top of Pole Mount Edition v1.01. For models:

Installation Manual. Tamarack Solar Products. Side of Pole Mount Edition v1.02. For models:

XIAMEN MIBET NEW ENERGY CO., LTD SOLAR PANEL SUPPORT FRAME MRAC ANGLE-ADJUSTABLE MOUNTING SYSTEM FOR METAL CLAD FLAT ROOF

Installation Manual. Side of Pole Mount Edition v1.02. For models:

SOLAR ROOF MOUNTING SYSTEM INSTALLATION MANUAL Model Name TT-ADJUSTABLE TILT LEGS

Installation Manual. Side of Pole Mount Edition v3.24. For models:

ROOF MOUNT. *Class A* Fire Rated INSTALLATION MANUAL

Adjustable Mounting System Installation Manual

ROOF MOUNT. *Class A* Fire Rated INSTALLATION MANUAL

SolarMount-I INSTALLATION MANUAL Broadway Boulevard NE Albuquerque, NM USA A HILTI GROUP COMPANY

Flexi-Rail Solar Module Mounting System. Flexi Rail. Installation Manual

SolarMount (E)volution

Flush Mount. SunEarth Flush Mount Installation Manual. SunEarth Flush Mount. Asphalt Shingle Roofing

GROUND MOUNTING SYSTEM INSTALLATION MANUAL

Pole Mount Installation Manual

May 14, Installation Manual

Roof Mount Ground Mount Specialised Clamps Spares Application Notes

MANUAL MOUNTING SYSTEM FOR BITUMEN / EPDM

Pole Mounting System Installation Manual

Rooftop Installation Manual

Variable Pitch Collector Frame

MANUAL MOUNTING SYSTEM FOR CORRUGATED ROOF

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JAN01

1 of 9 SITE PLAN modules at 325W kw. Sample GAMECHANGE SOLAR. Sample. Sample AERIAL VIEW. Array Information. Design Information.

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JUN15

Rooftop Installation Manual

Flush Mount Kit. SunEarth Flush Mount Kit Installation Manual. SunEarth Flush Mount Kit. Asphalt Shingle Roofing

With Pitch Collector Frame

Rayport G Eco Dealer Kit

Check us out on-line! Installation Instructions

On-roof system Alpha + Product catalogue

Ventilation System. Installation Manual. Hog Slat Inc. Newton Grove, NC USA March

Artsign Adjustable Flat Roof Mount System

Installation Instructions Kit, Base Rail Bracket Part # 31413


Managing Director MIEAust, CPEng, NPER , RPEQ 12090, RBP EC-38461, NT BPB ES

Mounting systems for solar technology

CountryAccents Pergola Assembly Instructions

ADJUSTABLE MOUNTING POST

By SP Partners, LLC. INSTALLATION GUIDE. ProTech

Martin Gamble Milan Bjelobrk Managing Director MIEAust, CPEng, NPER , RPEQ 12090, RBP EC-38461, NT BPB ES

ALUMA-VENT AWNING REGULAR END STYLE INSTALLATION INSTRUCTIONS

Page 1 of 18. SunRail System Installation Instructions

Structural Design Documentation

Alpha + On-Roof System Installation manual

Roof Attachment Overview

00108/00110 INSTRUCTION MANUAL

Array Frame Engineering Certificate

Desk/Wall-Mount Rack

Instruction Sheet REB SERIES. Rotating Sliding Base REB18

Unirac Installation Manual

2.0. Select Rail & Stair Kit Assembly and Installation Instructions BOM V2 5/13. Owner's Manual. Version

GABLE ROOF CARPORT RECOMMENDED INSTRUCTION MANUAL

THANK YOU FOR PURCHASING OUR STUDIO RTA PROJECT STATION

Pan & BoxBrake Vise Attachment. Item no:

ASSEMBLY INSTRUCTIONS GL75. BASE SIZE: 2.190m x 1.520m

INSTALLATION GUIDE CABINETRY

Lodge II Pergola. Manual and Installation Instructions. Please read these instructions before removing parts from crate

SolarRoofHook CATALOG. (844) A DIVISION OF QUICKSCREWS INTERNATIONAL CORP.

Catalog. Mounts. Racking. Systems. Rail Clamps L-Feet. Pub. C10001-V013

Assembly Instructions and Parts Manual JPSF-1 Fence and JPSR Rail Set

INSTALLATION MANUAL SONANCE SOUNDBARS SB46 M AND SB46 L. Introduction. Box Contents. Wall Mount Installations

Rayport G Eco Dealer Kit

Catalog. Mounts. Racking. Systems. Rail Clamps L-Feet. Pub. C10001-V020

Pryda Timber Connectors

ASSEMBLY INSTRUCTIONS GG77. BASE SIZE: 2.190m x 2.020m

ASSEMBLY INSTRUCTIONS SS2010. BASE SIZE: 2.020m x 1.020m

MODERN PERGOLA INSTALLATION GUIDE. When only the best will do.

Sonoma Outdoor Kitchen Pergola. Assembly Instructions

installation guide Villa

Copyright 2010 AIA MasterSpec Premium 08/10 PRODUCT MASTERSPEC LICENSED BY ARCOM TO TRA SNOW AND SUN.

GearBoss II High Density storage

NEVADA ASSEMBLY INSTRUCTIONS

DUTCH GABLE CARPORT RECOMMENDED INSTRUCTION MANUAL

Patented Rail-Free Mounting System for Composition/Asphalt Shingle Roofs

Catalog. Mounts. Racking. Systems. Rail Clamps L-Feet. Pub. C10001-V016

GLOSSARY OF TERMS SECTION 8

Mounting systems for solar technology

25-A Shawnee Way Bozeman, MT Fed ID PH FAX

INSTALLATION MANUAL POST SLEEVE SURFACE MOUNT WITH WOOD INSERT. Model # BKT SLV MT W/WD KT V HOMEDEPOT.COM/VERANDA

FXL-168 FIXED RACK ASSEMBLY INSTRUCTIONS SALES ORDER #

Installation Manual Roof Frames for Use with Rinnai Solar Hot Water Systems

Transcription:

Mounting Systems Tilt Kit Installation Guide Table of Contents Part I. Preparing.. 2-6 Part II. Feature of the Rail and the Module 6-8 Part III. Planning the array laylout... 9 Part IV. Installation instruction. 10-18 Part V. Angle Adjustment Description 19-20 Part VI. Warranty...21 Compliant Planning and Installation with Australia AS/NZS1170 Chiko Flat Pitched roof installation roof installation Guide Gui Pub CM-V3.4 10 Mar 2012

I. Preparing 1. Determine the wind region of your installation site Region Definition: Wind regions are pre defined for all of Australia by Australian Standard 1170. The Wind Region has nothing to do with surrounding topography or buildings. Most of Australia is designated Region A which indicates a Regional Ultimate Basic Wind Velocity of 45msec. Some areas are designated Region B (57msec). Local authorities will advise if this applies in your area. Region C areas (66msec) are generally referred to as Cyclonic and are generally limited to northern coastal areas. Most Region C zones end 100km inland. Region D (80msec) Australia's worst Cyclonic Region between Carnarvon and Pardoo in Western Australia. 2

2. Determine the installation area on the roof Chiko Mounting system may be installed anywhere on a roof but fixing centres are required to be reduced at ridges and edges. The diagram below shows the area of higher wind within a (minimum of 0.2a and 0.2b) of a roof edge or ridge (where b and d are the plan dimension of the building). The following table will help you determine the maximum rail support spacing for your project. Also note that if the roof slope is less than 10 degree the reduction on spacing does not apply. 3. Determine the height of the of your installation site This document provides sufficient information for Roof system installation height less than 20 meters. If your installation site is more than 20 meters in height, please contact Chiko Solar to obtain engineering data to support your installation. 4. Determine the Maximum Rail Support Spacing * Each row of solar panels shall have minimum of two rows of railing fixed to the roof framing. * The spacing of the rail fixing shall not exceed the recommended spacing, and shall be reduced to match the location of the roof rafter. 3

4.1Please use the following table to determine the Chiko Standard Rail (CK-FZ-R)support spacing for 4.1Please use the following table to determine the Chiko Standard Rail (CK-FZ-R)support spacing for Tilt kit installations to metal sheet roof. The table below is based on solar modules length of 1600-1960mm: Spacing (mm) of Tilt kit for angle of Tilt 10-15deg Installation Region A & B Region C & D Height Spacing(mm) Spacing(mm) 5 Meters 700 390 10 Meters 590 350 15 Meters 535 310 20 Meters 505 280 The table below is based on solar modules length of 1600-1960mm: Spacing (mm) of Tilt kit for angle of Tilt 15-30deg Installation Region A & B Region C & D Height Spacing(mm) Spacing(mm) 5 Meters 555 310 10 Meters 460 280 15 Meters 415 240 20 Meters 390 220 The table below is based on solar modules length of 1600-1960mm: Spacing (mm) of Tilt kit for angle of Tilt 30-60deg Installation Region A & B Region C & D Height Spacing(mm) Spacing(mm) 5 Meters 875 430 10 Meters 720 390 15 Meters 650 340 20 Meters 615 300 4.2Please use the following table to determine the Chiko New Rail (CK-FB-R)support spacing for Tilt kit installations to metal sheet roof. The table below is based on solar modules length of 1600-1960mm: Spacing (mm) of Tilt kit for angle of Tilt 10-15deg Installation Region A & B Region C & D Height Spacing (mm) Spacing (mm) 5 Meters 630 380 10 Meters 530 330 15 Meters 480 290 20 Meters 450 260 4

The table below is based on solar modules length of 1600-1960mm: Spacing (mm) of Tilt kit for angle of Tilt 15-30deg Installation Region A & B Region C & D Height Spacing (mm) Spacing (mm) 5 Meters 500 310 10 Meters 410 280 15 Meters 370 240 20 Meters 350 220 The table below is based on solar modules length of 1600-1960mm: Spacing (mm) of Tilt kit for angle of Tilt 30-60deg Installation Region A & B Region C & D Height Spacing (mm) Spacing (mm) 5 Meters 780 410 10 Meters 630 370 15 Meters 570 330 20 Meters 540 290 The Tilt kit hooks should be fixed to the purlin using two gauge 14 screws minimum. the screws used to attach the railing to the roof framing shall conform to AS3566, ISO3506.1 The Cold formed steel purlins to support railing shall have minium base material thickness 1.2mm in Regions A&B, and 1.9mm in regions C&D. Predrilled holes shall be used for all screw fixings into timber. The width of Timber purlins shall ot be less than 35mm. The minimum embedment for each screw shall be 70mm. Timber with Joint Type classification J5 and J6 are excluded unless tested for Screw capacity. Please consult Chiko Solar for installing solar modules greater than length of 1960mm and weight of 27KG. 5. Verify acceptable Rail End Overhang Rail End Overhang must equal 50 percent or less of the adjacent spacing of the installed fixing. Thus if fixing spacing is 1200mm, the Rail End Over hang can be up to 600mm. The panel overhang shall not exceed 30% of panel length,(ex 480mm for 1600mm long ) 6. Determine Roof slope Solar Roof system can be used for roof slope up to 60 degrees. Please verify the Installation site roof slope should be between 0 degrees and 60 degrees. 5

7. Installation tools Solar Mounting Systems 6 mm Allen key; Cordless drill; Open-end spanner set 9, 10, 17, 19 mm (required only for mounting with hanger bolts); Torx-30 (AW 30) bit; Angle grinder with stone disk; Power Cord; If necessary, timber to shim the roof hooks. 8. Installation Rule The installation of the framing shall conform to relevant Australia Standards, Manufacturer's specifications and good building practice.the roofing to which the panels are to be installed shall conform to the relevant Australia Standards including AS1684, AS4440,AS1720, AS4100, and AS4600. 9. Installation attendtion If our racking material aluminium fix into meterial roof (zinc coated), pls use a suitable inert material ( ex EPDM ) to separated them to prevent galvanic corrosion. Pls refer to the aluminium material. II. Feature of the Rail and the Module 1. Rails and modules can be installed through the top and sides, the bottom rail can be fixed by M8 hex bolts(three directions can be fixed). Module can be installed from the end to slide to the middle of the rail, also you can directly install from any part of the rail. This can effectively improve the installation efficiency. CK-FZ-R Installation 6

2. CK-FB-R Installation 2.The design of the corrugated surface of the Rail with the corrugated surface of the hook linked closely, effectively increasing in friction and anti-slip effect. Closed loop design of the internal rails ensures the overall strength and the reasonable force distribution. CK-FZ-R CK-FB-R 3. Two rails can be connected by rail splice, saving every section of tailings, so that the rails of different lengths can be continuously extended, not only can reduce the waste tailings, but also can reduce the production of rails troubled by the length of the limit. 7

4. 35-50mm depth solar panel frame can be installed by CHIKO adjustable mid clamp and adjustable end clamp, more convenient, more strong. 35mm depth 40mm depth 45mm depth 50mm depth 5. Chiko standard tilt kit and fixed tilt kit are engineered for the extensive flexibility in designing and planning for the commercial and residential roof solar jobs. Both front leg and rear leg can be high pre-assembly to make the installation easy and quick, save your labor cost and time. 8

III. Planning the array layout Planning the array layout 1.Array width = number of modules in horizontal direction x (solar module width + 11/16 in (18 mm)) +1-1/4 in (32 mm) 2. spacing of tilt kit for various angle (refer to talbe1, table2 and table3) 3.distance between front leg and back leg shall not exceed the distance given on table below Maximum distance (mm) between purlins supporting front and back leg Tilt Angle Region A&B Region C&D 15 1800 1400 30 1800 1200 60 1800 900 4.Distance between the solar modules: 11/16 in (18 mm) 9

IV. Installation instruction 1.Chiko Standard Tilt Kit 1.1 Fix the tilt kit on roof directly. 1)Fix up the front leg, rubber pad to the roof by two 6.3*90mm wood screws 2)Fix up the rail to the front leg by the module on the front leg. 3)Fix up the back leg, rubber pad to the roof by two 6.3*90 wood screws. 10

4)Fix up the rail to the back leg by the L-type module on the back leg. Solar Mounting Systems 5)As the requirement of Planning the array layout, Fix up front leg, back leg and rail on the roof. 6)Fix up the solar panel on the rail 11

1.2 Connect with Chiko Tin roof clamp Fix Tilt kit while connected with Chiko Tin roof clamp foot (kliplock 406 &700& tin hooks) will not cause any damages to tin roof, make the mount system more stronger. Following illustrations show the installation with different clamps briefly. 12

2.Chiko Fixed Tilt Kit 2.1 Fix the tilt kit on roof directly. 1)Fix up the front leg, rubber pad to the roof by two 6.3*90mm wood screws 2)Fix up the rail to the front leg by the module on the front leg. 3)Fix up the back leg, rubber pad to the roof by two 6.3*90 wood screws. 13

4)Fix up the rail to the back leg by the L-type module on the back leg. Solar Mounting Systems 5)As the requirement of Planning the array layout, Fix up front leg, back leg and rail on the roof. 6)Fix up the solar panel on the rail 14

2.2 Connect with Chiko tin roof clamp Fixed Tilt kit also can be connected with Chiko Tin roof clamp foot (kliplock 406 &700& tin hooks) when install panels, will not cause any damages to tin roof, make the mount system more stronger. Following illustrations show the installation with different clamps briefly. 15

7. Install CHIKO normal mid clamp and end clamp (1) Fix up the solar panel on the rail by the end clamp, M8*25 hexagonal head screw and module. Fix up the Adjacent two solar panels on the rail by middle clamp and M8 Hexagon head screw (The length of the Hexagon head screw is according to the thickness of solar panel). (2)The rest can be done in the same manner. Fix up all the solar panels on the rails. 16

8 Install CHIKO adjustable mid clamp and adjustable end clamp (1) Fix up the solar panel on the rail by the adjustable end clamp, M8*25 hexagonal head screw and module. Fix up the Adjacent two solar panels on the rail by adjustable middle clamp and M8 Hexagon head. The following show 35mm depth solar panel frame, 40mm, 45mm, 50mm, in the same way. 17

(2)The rest can be done in the same manner. Fix up all the solar panels on the rails. 18

V. Angle Adjustment Description 1)Chiko Standard Tilt Kit Loose two M8 no head inner hex bolts on the back leg, adjust the length of back leg pipe, then fixup two M8 no head inner hex bolt to adjust the angle. 19

Adjustable Angle mounting systems: there are three types according to the angle scope (1). 10-15Adjustable angle Mounting System (2)15-30Adjustable angle Mounting System (3)30-60Adjustable angle Mounting System 2) ChikoFixed Tilt Kit Customized rear leg length to meet different angles requirement, 15deg,20deg,30deg mounting system are always have stocks. 20

VI. Warranty 10years limited product warranty, 5 years limited finish warranty Chiko Solar Industry Co., Ltd. warrants to the original purchaser ("Purchaser") of product(s) that it manufactures ("Product") at the original installation site that the Product shall be free from defects in material and workmanship for a period of ten (10) years, except for the anodised finish, which finish shall be free from visible peeling, or cracking or chalking under normal atmospheric conditions for a period of five (5) years, from the earlier of 1) the date the installation of the Product is completed, or 2) 30 days after the purchase of the Product by the original Purchaser ("Finish Warranty"). The Finish Warranty does not apply to any foreign residue deposited on the finish. All installations in corrosive atmospheric conditions are excluded. The Finish Warranty is VOID if the practices specified by AAMA 609 & 610-02 "Cleaning and Maintenance for Architecturally Finished Aluminum" (www.aamanet.org) are not followed by Purchaser. This Warranty does not cover damage to the Product that occurs during its shipment, storage, or installation. This Warranty shall be VOID if installation of the Product is not performed in accordance with Chiko Solar s written installation instructions, or if the Product has been modified, repaired, or reworked in a manner not previously authorized by Chiko Solar IN WRITING, or if the Product is installed in an environment for which it was not designed. Chiko Solar shall not be liable for consequential, contingent or incidental damages arising out of the use of the Product by Purchaser under any circumstances. If within the specified Warranty periods the Product shall be reasonably proven to be defective, then Chiko Solar shall repair or replace the defective Product, or any part thereof, at Chiko Solar's sole discretion. Such repair or replacement shall completely satisfy and discharge all of Chiko Solar's liability with respect to this limited Warranty. Under no circumstances shall Chiko Solar be liable for special, indirect or consequential damages arising out of or related to use by Purchaser of the Product. Manufacturers of related items, such as solar modules and flashings, may provide written warranties of their own. Chiko Solar's limited Warranty covers only its Product, and not any related items. 21