MEGA Servo setup procedure for driving PMS motor

Similar documents
FRENIC MEGA in Injection Moulding Machine s applications

Pump / compressor Duty Cycle control function with FRENIC MEGA

OPC-E1-PG3 Specifications

A700 VFD with SSCNET III eth1000_large.jpg

Using CME 2 with AccelNet

L E C T U R E R, E L E C T R I C A L A N D M I C R O E L E C T R O N I C E N G I N E E R I N G

SGDH Amplifier. Part Number Guide. Quick Reference Guide. Amplifier: SGDH - 15 A E- Motor: SGMGH - 09 A C A 6 C $10

Single-phase or three phase AC220V (-15% ~ +10%) 50 ~ 60Hz

[ 4 ] Using pulse train input (F01 = 12)

V&T Technologies Co., Ltd. Vectorque TM V6-H-M1 SERIES INVERTER ADDITIVE MANUAL (M1) V6-H Series ADDITIVE MANUAL V& T

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

HPVFP High Performance Full Function Vector Frequency Inverter

CHAPTER 8 PARAMETER SUMMARY

Tech Note #3: Setting up a Servo Axis For Closed Loop Position Control Application note by Tim McIntosh September 10, 2001

Motor Drives & Controllers

Shenzhen Alpha Inverter Co., Ltd. AS100 AC Servo Drive

ADTECH Solar inverter

For more information on these functions and others please refer to the PRONET-E User s Manual.

(Supplement to Instruction Manual)

Product Application Note. Comparison of Higher Performance AC Drives and AC Servo Controllers. Applicable Product: General AC Drives

QUICK GUIDE PUMP CONTROL. Frequency inverter for pump control and HVAC applications. Date Version 22/09/

NICE900 -Door Drive Setup Manual for Asynchronous / Synchronous Motor with Encoder Feedback (Document Release Dt ) Sr. No

Experiment 2 IM drive with slip power recovery

Latest Control Technology in Inverters and Servo Systems

6.9 Jump frequency - Avoiding frequency resonance

Before you operate the inverter, the parameters that you must first program are the basic parameters.

FR-A8APR INSTRUCTION MANUAL

Step vs. Servo Selecting the Best

MTY (81)

Experiment 3. Performance of an induction motor drive under V/f and rotor flux oriented controllers.

AC Drive Technology. An Overview for the Converting Industry. Siemens Industry, Inc All rights reserved.

Multi-function, Compact Inverters. 3G3MV Series

Chapter 8 Troubleshooting

Spansion Sensor-less Washing Machine Solution. May, 2014 / Arthur Zhong

Commissioning manual. Powerdrive MD2/FX

Upgrading from Stepper to Servo

A COMPARISON STUDY OF THE COMMUTATION METHODS FOR THE THREE-PHASE PERMANENT MAGNET BRUSHLESS DC MOTOR

TOSHIBA MACHINE CO., LTD.

Katalog für Kollmorgen Automationsund Antriebslösungen

CD1-pm - User manual. CD1-pm User manual gb PROFIBUS POSITIONER INFRANOR. CD1-pm - User manual 1

FUJI Inverter. Standard Specifications

PMSM Control Using a Three-Phase, Six-Step 120 Modulation Inverter

Control of Electric Machine Drive Systems

PG Interface Card "OPC-E2-PG"

User Guide IRMCS3041 System Overview/Guide. Aengus Murray. Table of Contents. Introduction

JetMove 1xx, 2xx, D203 at the JetControl Drive

Software User Manual

Initial Commissioning of Motors

Application Note for Vector Control with the SJ300 Inverter

STEPPING MOTOR EMULATION

Basic Tuning for the SERVOSTAR 400/600

Renewable Energy Based Interleaved Boost Converter

Analog Devices: High Efficiency, Low Cost, Sensorless Motor Control.

BLuAC5 Brushless Universal Servo Amplifier

Frequently Asked Questions (FAQs) MV1000 Drive

ROLL TO ROLL FUNCTION MANUAL FR-A (0.4K)-04750(90K)-R2R FR-A (0.4K)-06830(280K)-R2R FR-A (315K)-12120(500K)-R2R

vacon nx all in one application manual ac drives Phone: Fax: Web: -

MTY (81)

INTEGRATED CIRCUITS. AN1221 Switched-mode drives for DC motors. Author: Lester J. Hadley, Jr.

Application Note: The electronic control of ALXION ST STK torque motors for direct drive of automated axis

BLuAC5 Brushless Universal Servo Amplifier

3. What is the difference between Switched Reluctance motor and variable reluctance stepper motor?(may12)

User Guide Introduction. IRMCS3043 System Overview/Guide. International Rectifier s imotion Team. Table of Contents

Hitachi P1 Closed Loop Hoist Basic Instruc on Manual

8510 AC Spindle Drive System

combine regular DC-motors with a gear-box and an encoder/potentiometer to form a position control loop can only assume a limited range of angular

SYSTEM OVERVIEW. Kollmorgen GOLDLINE BH & SERVOSTAR 600 Systems

No Gain Tuning. Hunting. Closed Loop System

Servo Tuning. Dr. Rohan Munasinghe Department. of Electronic and Telecommunication Engineering University of Moratuwa. Thanks to Dr.

RMC22 commutation and incremental encoder solution / complementary sinusoidal outputs

EDC Quick Start Guide

VECTOR INVERTER -INSTRUCTION MANUAL- POSITION CONTROL FR-V5AP

Preface. Notes. Thank you for purchasing the VTP8 series AC drive.

AZ Series. Function Edition. Closed Loop Stepping Motor and Driver Package. Operation. I/O signals. Parameter

Fuzzy Logic Controller Based Direct Torque Control of PMBLDC Motor

815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS

Troubleshooting Alarm Displays Warning Displays

Digital Control of Permanent Magnet Synchronous Motor

HIGH PERFORMANCE CONTROL OF AC DRIVES WITH MATLAB/SIMULINK MODELS

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS

Copyright 2014 YASKAWA ELECTRIC CORPORATION All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or

Feedback Devices. By John Mazurkiewicz. Baldor Electric

Brushless DC-Servomotors with integrated Encoder 4 Pole Technology

Free Programmable Signal Processing inside a High Performance Servo Amplifier

ServoPac-A TTA-PRO Positioner

EE 560 Electric Machines and Drives. Autumn 2014 Final Project. Contents

3Configuration CHAPTER THREE IN THIS CHAPTER. Configuration Tuning Procedures. Chapter 3 Configuration 23

Basic NC and CNC. Dr. J. Ramkumar Professor, Department of Mechanical Engineering Micro machining Lab, I.I.T. Kanpur

Exercise 2-2. Antenna Driving System EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION

ENGINEERING SPECIFICATION

INSTRUCTIONS YASKAWA. Upon receipt of the product and prior to initial operation, read these instructions thoroughly, and retain for future reference.

Brushless DC-Servomotors with integrated Encoder 4 Pole Technology

Servo Solutions for Continuous and Pulse Duty Applications

SPEED CONTROL OF PERMANENT MAGNET SYNCHRONOUS MOTOR USING VOLTAGE SOURCE INVERTER

Troubleshooting 12. This section explains the items to check when problems occur, and troubleshooting by the use of error displays or operation state.

CSMIO/IP-A motion controller and Mach4

Industrial Control Equipment. ACS-1000 Analog Control System

RX23T inverter ref. kit

2.017 DESIGN OF ELECTROMECHANICAL ROBOTIC SYSTEMS Fall 2009 Lab 4: Motor Control. October 5, 2009 Dr. Harrison H. Chin

XtrapulsEasy. U s e r G u i d e D I G I T A L D R I V E F O R S I N U S O I D A L S Y N C H R O N O U S AC M O T O R S.

Transcription:

Application Note AN-MEGA-0016-v105EN MEGA Servo setup procedure for driving PMS motor Inverter type FRENIC MEGA (-EAQ Type) Software version 1700 Required options OPC-G1-PG, OPC-G1-PG2, OPC-G1-PG22, OPC-G1-PMPG or OPC-G1-RES Related documentation MEGA Servo IM, SI47-1545-E Author Joan Manel Ibáñez Use Public, Web Date 21/10/2011 Version 1.0.5 Languages English 1. Introduction. MEGA Servo inverter is able to drive a PM Synchronous motor in closed loop control. In this case, the procedure to set up the motor related parameters is a bit different. This document describes a procedure in order to set up the inverter, when driving PMSM with MEGA Servo. 2. Description. The commissioning procedure for FRENIC MEGA Servo is depicted in figure 1 (extracted from the FRENIC MEGA Servo IM, SI47-1545-E). For controlling Permanent Magnet Synchronous motor an incremental encoder (open collector or line driver), an absolute encoder (with U, V and W commutation signals) or a resolver must be used as a speed/position feedback. For further details in the installation of the required option card (according to the feedback type used) please refer to the option card instruction manual. Once the wiring of the motor and the encoder is finished, it is time to set up the inverter in order to drive properly the motor. This document explains the part of the procedure from the Selection of the motor type to the Adjust motor control function code data. Application Note AN-MEGA-0016v105EN 1

Figure 1. Inverter Commissioning Procedure 2.1 Permanent Magnet Synchronous Motor parameters setting The first step consists into setting the PM Synchronous motor control in the inverter, and the motor capacity: - F42 = 16 (Vector control with speed sensor for PMSM) - P02 = Motor Capacity (from motor s nameplate) When F42 = 16, the PMS motor parameters will be available (P01 to P03, P30 to P95). Once the PMSM control is activated, and the motor capacity is set, the next step is to reset the Motor 1 parameters. In this way, the motor parameters (including the PMS motor parameters) will be reset to the default settings for this capacity: - H03 = 2 (Initialize motor 1 parameters) Now the inverter is ready for the motor parameters setup. The minimum parameters to set, in order to perform Auto-tuning procedure are shown in table 1. Application Note AN-MEGA-0016v105EN 2

Function code Table 1. Parameter Setup from SI47-1545 manual Name Function code data Factory default f 04 Base frequency 1 50.0 (Hz) Rated voltage at base f 05 Standard motor rated voltage frequency 1 Motor ratings p 01 Motor 1 (Pole number) (print on the nameplate of the motor) 4 pole p 02 (Rated capacity) Standard motor capacity p 03 p 30 p 90 d 14 d 15 (Rated current) Magnet pole position detection method selection Overcurrent protection level Feedback input (Pulse input format) (Encoder pulse resolution) f 08 Deceleration time 1 Motor type Current limitation value to prevent demagnetization It is used to protect the demagnetization by the motor overcurrent. Set the value when understanding. Type of the target motor encoder 2: Pulse count of the target motor encoder Standard motor rated current 1: IPM 0.00 (A) (disable) A/B phase with 90 degree phase shift 0400 (hex) (1024 P/R) f 03 Maximum output frequency 1 Specification value 50.0 (Hz) f 15 Frequency limiter (upper) Note) When running the motor for a test, set to 70.0 (Hz) specification value or more. In the f 07 Acceleration time 1 specification value or less, motor might not be able to normally drive. 22 kw or less: 6.00 (s) 30 kw or more: 20.00 (s) 22 kw or less: 6.00 (s) 30 kw or more: 20.00 (s) Note: F03, F15, F07 and F08 will be taken into consideration only if the dynamic autotuning (P04 = 2, described below) is used. The P30 initial setting should be set depending on the motor permanent magnets arrangement: - P30 = 1. In case of Inner Permanent Magnets (IPM) motor (setting by default, this will be the setting normally used as the majority of motors behave as IPM type). - P30 = 2. In case that Surface Permanent Magnets (SPM) synchronous motor is controlled. During normal operation (except commissioning), the setting of P30 is relevant only when using incremental encoder. If information about function P90 ( Overcurrent protection level ) is not available, a typical setting could be the double of the rated current. This setting is very important in order to avoid damaging the Permanent magnets of the motor. 2.2 Complete Auto-Tuning and Pole-Tuning Procedure (especially when using incremental encoder). Now it is time to perform Auto-tuning and Pole-tuning procedures. Please find in table 2 the different Auto-tuning and Pole-tuning procedures available if permanent magnet motor control is active (F42 = 16). Application Note AN-MEGA-0016v105EN 3

1 2 4 Table 2. Different Auto-tuning and Pole-Tuning procedures from SI47-1545 manual. Motor parameters Select under the following P04 data Tuning operation subjected to tuning conditions Tune without rotating the motor Tune with the motor rotating Pole Tuning with the motor rotating Primary resistance (P60) d-axis inductance (P61) q-axis inductance (P62) reserved (P84, P88) Primary resistance (P60) d-axis inductance (P61) q-axis inductance (P62) Inductor voltage (P63) Reserved (P84, P88) Magnetic pole position sensor offset (P95) Magnetic pole position sensor offset (P95) Tuning with the motor stopped. Tuning the P60 to P62, P84 and P88, with the motor stopped. Tuning the P63 with the motor rotating (50 % of base frequency). (F42=16, and P95=999) Tuning the P95 with the motor rotating (rotation speed = d80). Tuning the P95 with the motor rotating (rotation speed = d80). Impossible to rotate the motor. Because the mechanical load have already been installed. P30=1 or 2 (Note) In case of P30=0 (No operation) or P30=3 (Simple IPM method), tuning without rotating the motor can not be used. Possible to rotate the motor, the motor is not coupled to any mechanical load. Possible to rotate the motor, the motor is is not coupled to any mechanical load. When using the vector control with speed sensor for PMSM. (F42=16) The recommended procedure for the Auto-Tuning and Pole-Tuning is as follows: 1- Calculate P63 Inductor Voltage value. To calculate this value, the Ke constant of the motor is needed (normally supplied by motor manufacturer). Once calculated, save the value in the inverter. Nrtd P63 = Ke 1000 Where: Ke is the back EMF constant, in V/1000rpm N rtd is the rated speed in rpm 2- Perform static Auto-Tuning (P04 = 1). This will calculate the P60, P61, P62, P84 and P88 motor parameters. If OCx or Er7 alarm occurs during this procedure, please check that the back EMF (P63), rated frequency (F04) and rated voltage (F05) parameters are properly adjusted. If it s not possible to perform the Auto-Tuning even the above mentioned parameters have been adjusted, please refer to Step 4. 3- Perform Pole-Tuning (P04 = 4). The motor will move at d80 speed and function P95 (magnetic pole offset) will be measured. Therefore, the motor must be in no load condition. If Er7 appears during this procedure, please take into account that the speed loop parameters (ASR) affect the pole tuning procedure. A good tip could be to disable the several filters (d01, d02 and d05) or modify the speed loop constants (d03, d04). If it is not possible to solve the problem by adjusting these parameters, please set P30 to the correct value. Application Note AN-MEGA-0016v105EN 4

If incremental encoder is used, then inverter will perform automatically Pole-Tuning at the very first RUN Command after every inverter power up. Please refer to point 4 explanation, below. 4- Once Static Auto-tuning and Pole-Tuning are finished, the value in P86 (North-South discrimination value) must be bigger than 10% to ensure a proper pole offset detection. In case we cannot achieve P86 > 10%, the first countermeasure to take would be to slightly increase the value of P87 and test again. If P87 is increased but P86 is still smaller than 10%, then P30 value must be changed. P30 must be changed if Er7 arises, as well. Please refer to table 3 below. Permanent Magnet Table 3. P30 setup process Initial Tuning P30 Application Note AN-MEGA-0016v105EN 5 New P30 IPM 1 P86 < 10% or Er7 3 SPM 2 P86 < 10% or Er7 0 If P30 is set to 3 or 2 and Er7 still occurs then please set P30 to 0 and try to perform Dynamic Auto-tuning. When using incremental encoder, the automatic Pole-Tuning procedure will change depending on the P30 value. Please refer to Table 4. Table 4. Pole-Tuning behaviour in case of using incremental encoder F42 data Encoder P95 data P30 data Starting operation 16: Vector control with sensor for PM Incremental: A/B phase with 90 degree phase shift and Z phase 999 (No adjustment of offset) 0.0 to 359.9 (Offset has been adjusted) 0: Alignment method by current 3: Alignment method by current for IPMSM 1: Method for IPMSM 2: Method for SPMSM < Start impossible > erc alarm is occurred, and it does not start. Adjust P95. < Magnetic pole position detection start > After detecting the magnetic pole position, it starts from 0 Hz. 0, 3 < Magnetic pole position alignment start > Only at the first operation after the power supply of the inverter has been turned on, the magnetic pole position alignment operates by the frequency of d80. After the magnetic pole position alignment is completed, inverter accelerates the motor to the reference speed. From second operation, it starts from 0 Hz (Normal start). The magnetic pole position alignment operation takes the time for one rotation of the mechanical angle in maximum case. ( Function code d80) 1, 2 < Magnet pole position detection start > After magnetic pole position detected, it starts from 0 Hz. Only in case of P30 = 1 or 2, the automatic Pole-Tuning at every power up will be completely static, so no other consideration must be taken into account. On the other hand, if P30 is equal to 0 or 3, this automatic Pole-Tuning after the power up will not be static, and the inverter will turn the motor at d80 speed. This behaviour may not be acceptable in certain applications (e.g. vertical loads).

If it is not possible to calculate the back EMF constant value (P63) or if the value of P30 is different than 1 or 2, the dynamic auto-tuning procedure (P04 = 2) is available for the user. During the Dynamic Auto-Tuning, no load must be attached to the motor shaft. When P30 = 0, it is recommended to set F23 = 1.0 Hz and F24 = 1.0 s momentarily, just for the Dynamic Auto-Tuning procedure. The Dynamic Auto-Tuning consists on the following stages: a. Static Auto-tuning, like the point 2 in the procedure above. b. Dynamic Pole-Tuning, like the point 3 in the procedure above. c. Calculation of the P63 value, with the motor driving at the half of the rated speed (F03). For this stage, acceleration/deceleration times and maximum speed level have to be properly set. 2.3 Simplified Auto-Tuning and Pole-Tuning Procedure (for resolver or absolute encoder) Alternatively, a simplified procedure for the Pole-Tuning + Auto-Tuning can be performed in case resolver (d14 =2) or absolute encoder (Incremental + U, V, W signals, d14 = 4) feedbacks are used. After setting the function codes described in Table 1, please set P30 = 0 and execute the Dynamic auto-tuning (P04 = 2), as described in previous subchapter 2.2 (instead of following steps 1 to 4 from the procedure described in subchapter 2.2). 2.4 Current Loop gain setting After the Auto-Tuning procedure, it s time to adjust the Current Loop gain (d91). Normally, it is not needed to change the default setting (999), because in this case the inverter will use a value based on the motor parameters. Modify the d91 value only if: - Current flowing in the motor is not enough to achieve the desired dynamic performance (even the Torque Command value is saturated): increase slightly d91 value, and test again. - If OCx errors arise when trying to move the motor, or if noise from the motor can be observed when current is flowing through it, or when the inverter output current wave shape is not a sinusoidal shape: decrease slightly d91 value, and test again. The base value for testing a new setting in d91 (the default setting is 999: Automatic ) can be obtained by means of the following formula: Ld I n K d91 = Vn where, Ld, is the motor d-axis inductance in mh, from P61 I n is the motor rated current in A (value set in P03) K is a constant value, 2.165 V n is the motor rated voltage in V (value set in F05) Note: d91 value depends only on the motor parameters, not in the load or the mechanical configuration (inertia, gear ratio, etc.) of the installation. Application Note AN-MEGA-0016v105EN 6

3. Conclusion. Using FRENIC MEGA Servo software version, the inverter will be able to drive PM synchronous motors in closed loop. The commissioning procedure of a PM synchronous motor is slightly different to an Induction Motor. Following this procedure, the inverter will be adjusted for driving properly a Permanent Magnet synchronous motor in closed loop. 4. Document history. Version Changes applied Date Written Checked Approved 1.0.0 First version 05/08/2011 JM Ibañez 1.0.1 Small text corrections 29/08/2011 JM Ibáñez 1.0.2 Added several explanations 09/09/2011 JM Ibáñez D.Bedford 1.0.3 Small text corrections 14/09/2011 JM Ibáñez D.Bedford D.Bedford Added simplified procedure 1.0.4 Added calculation formula of d91. 21/10/2011 JM Ibáñez D.Bedford D.Bedford Some text corrections 1.0.5 Text correction in point 2, section 2.2 Resolver setting added in 2.3 05/01/12 JM Ibáñez S. Ureña D.Bedford Application Note AN-MEGA-0016v105EN 7