Tempus Digital Digital Astro-Timer D GB CZ BZT28A71. Installation and Operating Manual BZT28A71

Similar documents
SELEKTA SELEKTA 170 top2 D GB F I E P NL PL. Installation and Operating Manual Digital astronomic time switch. SELEKTA 170 top2

TR TR 641 top TR 642 top TR 644 top TR 641 top2 RC TR 642 top2 RC TR 644 top2 RC

*Current connection required for smooth zerocrossing switch operation

E N SHT-1 SHT-1/2 SHT-3 SHT-3/2

Sentry Digital Timers

OPERATING INSTRUCTIONS Digital weekly time switch

4TCD1. Digital 7-Day Programmable Timer. Installation Instructions. Tel Fax Schneider Electric (Australia) Pty Ltd

Instruction manual. art Installation manual

theben 4-/8-/12-Channel Switch Module Switch Actuator Modular with Basic Device RMG 4 - EIB and Additional Device RME 4 EIB

Time switches 16 A NEON SЕRIES. Heating and cooling. Shop displays. Lighting for parks. Streetlights and car park lighting.

Modular step relays 16 A

KNX manual 1-channel flush-mounted switch actuator SU 1

RAMSES 784 HF Set 1. Bedienungsanleitung Uhrenthermostat 1. Operating Instructions Clockthermostat 14. Mode d emploi Thermostat à horloge 26

Radio bus system Radio-universal dimming actuator, 1-gang. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

KNX manual High-performance switch actuators RM 4 H FIX1 RM 8 H FIX2

Overview per day of the programmed switching times 5 = Friday. Channel statuses / OFF

16-Channel Yearly Time Switch TR 648 S DCF

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1

12 Series - Time switches 16 A. Features

EIB/KNX Switch Actuators. User manual

Operating Manual MU2000K

This data sheet is only valid in association with the IL SYS INST UM E user manual.

ISOMETER IRDH575. Approvals

IMPULSE SWITCH, REMOTE SWITCH

Step relays 10 A SЕRIES. Lighting control in corridors (for hotels, offices and hospitals) Bedroom light control. Living room light control

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

Modular Devices - Indicators and Push Buttons

PIR6WT-1Z interface - time relays

13 SERIES. Electronic step relays A

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

K-BUS Switch Actuator

Mechanical daily time switch. 35 mm rail (EN 60715) mount

Electronic step, call/reset and monostable relays

Radio Touch Order no.: 2880 xx. Operation and installation instructions. 1 Safety instructions. 2 Structure of the device (Figure 1) Radio Touch

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Moeller Electric Corporation

SEPARATOR P20G TYPE USER S MANUAL

Power supply CP-E 24/2.5

62 Series - Power relays 16 A. Features / /

Power supply CP-E 24/20.0

LOW VOLTAGE CONVERTER WITH THREE POINT GALVANIC INSULATION

The power in relays and timers since Catalogue

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

38 Series - Relay Interface Modules A

W DATA SHEET Current Transformer 40 x 10, A

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

DIN Rail Time & Twilight Switches

Radiocontrol F. Floor Heating Controller Radio control system for floor heating

AHC-XP. Dewpoint-guided Power Controller for Glass and Handrail Heaters. Front view. Characteristics

LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications.

Radio receiver E17 2-channel, 27 MHz, 40MHz, or 433 MHz, 2 relay outputs. Operating voltage: 230 V/AC or 12 V or 24 V AC/DC available.

Power supply CP-E 24/0.75

Operating Instructions PROFITEST H+E TECH. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) /3.

Operating instructions Electronic level sensor LK / / 2008

Selection tables Command devices E 250 latching relays

Power supply CP-E 24/2.5

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

JUMO Wtrans Receiver with Wireless Data Transmission

38 Series - Relay interface modules A. Features /

Power supply CP-T 48/20.0 Primary switch mode power supply

Precipitation Monitor ,

EY-EM 527: Remote I/O module, ecolink527

QUINT-PS/ 3AC/24DC/10

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-T 48/5.0 Primary switch mode power supply

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply

Electrical devices may only be mounted and connected by electrically skilled persons.

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

WLDS-10 Mk3 MAJOR WATER LEAK DETECTION SYSTEM INSTALLATION & COMMISSIONING

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

Device manual Multifunction display and evaluation system FX 360. Mode/Enter

CM-IWM.11 Insulation monitoring relay

Power supply CP-D 24/1.3

EY-EM 522, 523: Remote I/O module, ecolink522, 523

Original operating instructions Fail-safe inductive sensor GG507S

Time Switches. Because we have a Responsibility

Level Switch NRS 2-50 NRS Original Installation Instructions English

Technical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity

1 Safety instructions. 2 Device components. 3 Function. Radio bus system. Radio socket-outlet adapter for switching Order No. :

02/11/2015

Manual for authorised electricians. Power meters. KD-401 Art.-Nr Version X00

Electronic impulse switches the silent revolution

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

MINI MCR-SL-UI-I-LP-NC

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

Thermostat P. Thermostats Electronic room thermostat with clock for thermal actuators

24HR/7 DAY YEARLY 4 CHANNEL INSTALLATION & OPERATING (4 MODULE) 16A. DIGITAL TIMESWITCH Cat. No TR644S INSTRUCTIONS

ABB i-bus KNX Energy Actuator SE/S Product Manual

Transcription:

2 8mm 310366 Tempus Digital Digital Astro-Timer BZT28A71 0,5mm - 2,5mm 2 0 6 12 18 24 L N 230-240V~ 50-60Hz R 10a -30T Installation and Operating Manual MENU OK BTZ28A71 D CZ PL HR 16(10)A 250V~ 1 2 3 µ BZT28A71 Correct connection required for smooth zero crossing switch operation (see connection diagram)!

Contents Basic safety instructions 3 Display and keys/operating instructions 4 Overview of menu selection 5 Connection/installation 6 Initial start-up 7 Menu item ASTRO Astro times, complete simulation, offset, astromode, position 8 Change position 9 Menu item PROGRAM Set switching time 10 Menu item MANUAL Manual and permanent switching 11 Menu item OPTIONS PIN code 12 Operating hours counter 12 Technical data 13 Service address/hotline 13 2

Basic safety instructions WARNING Danger of death through electric shock or fire! Installation should only be carried out by a professional electrician! The device is designed for installation on DIN top hat rails (in accordance with EN 60715) Corresponds to type 1 BSTU in accordance with IEC/EN 60730-2-7 Power reserve (10 years) Designated use The astronomic timer is used for lighting equipment (roads), external staircases, shop windows, entrances etc. For use only in closed, dry rooms Disposal Dispose of equipment in an environmentally-friendly manner 3

Screen display and keys Operating instructions Programmed ON times Date display 0 6 12 18 24 Sunrise/sunset display 1. Read text lines Flashing text/symbol is a prompt Channel status ON = On OFF = Off Time display Days of the week from 1 to 7 Display of active keys with relevant function 2. Make a decision MENU Activate screen Open menu Cancel menu ESC (leave menu) Selection options are displayed OK Save selection Confirm selection YES Confirmation OK press NO Change/ select press 4

Overview of menu selection DEUTSCH ENGLISH SPANISH RETAIN PROGRAMS DELETE PROGRAMS COUNTRY DEUTSCHLAND STUTTGART COORDINATES SPAIN ESTONIA FRANCE BERLIN BREMEN DRESDEN FORM DATE YEAR MONTH DAY GREAT BRITAIN DUESSELDORF FORM TIME HOUR MINUTE SU-WI EUROPE 28 02 08 ON 9:40 46 5

Connection/installation WARNING Warning, danger of death through electric shock! Must be installed by a professional electrician! Disconnect power source! Cover or shield any adjacent live components. Ensure device cannot be switched on! Check power supply is disconnected! Earth and bypass! Connect cable Strip cable by 8 mm (max. 9). Insert 45 cable in the open screwless terminal (2 cables per terminal position possible). To open the screwless terminal, press screwdriver downwards. Screwless terminal Spring screwless terminal NC contact Test tap 45 cable 6

Initial start-up Set language, country, town/city, date, time as well as summer/winter time (SO-WI) Press required key and display follows on screen (see fig). DEUTSCH ENGLISH SPANISH RETAIN COUNTRY DEUTSCHLAND STUTTGART PROGRAMS DELETE PROGRAMS COORDINATES SPAIN BERLIN ESTONIA BREMEN FRANCE DRESDEN FORM DATE YEAR MONTH DAY GREAT BRITAIN DUESSELDORF FORM TIME HOUR MINUTE SU-WI EUROPE 28 02 08 ON 9:40 46 7

ASTRO menu In the ASTRO menu astro times, complete simulation, offset, astromode as well as position (location) can be viewed or changed. Astro times Display of the astro times (including the offsets) for the current day Complete simulation Display of the switching behaviour with a freely selectable Start date (the holiday program is not displayed) Offset The offset (adjustment value) can be used to shift calculated astro times +/ 2 h. This enables the Astro switch-on and switch-off times to be adapted to local circumstances (e.g. mountains, high buildings etc.) or to personal requirements. Astro mode Evenings on, mornings off Switches on at sunset, switches off at sunset (Example: street lighting) Evenings off, mornings on Switches off at sunset, switches on at sunrise (Example: terrarium). Astro inactive The astro times are ineffective (timer function only). Position Location set by selecting a city or by coordinates (latitude/longitude, time zone). 8

Change position E.g. enter different country, a different city. Press MENU (see fig.). ASTRO ASTRO TIMES TOTAL SIMULATION OFFSET ASTROMODE LOCATION END COUNTRY COORDI NATES FRANCE SPAIN ESTONIA AJACCIO BAYONNE BORDEAUX DEUTSCHLAND GREAT BRITAIN BREST CAEN 9

Set switching time A time switch always consists of a start time and an end time (DURATION UNTIL). (e.g. night switch-off on Monday PROGRAM NEW 23:00 05:00 hrs) MEM FREE 56 CHECK or Press MENU (see fig.). There are 56 free memory locations available. MODIFY DELETE TOTAL SIMULATION END NIGHT BREAK HOUR MINUTE MONDAY DURATION UNTIL LIGHT ON Start time Copy switching to other days of the week. The day of the week always relates to a start time SAVE ADD TUESDAY COPY SAVE Switching time for one day 10

Manual and permanent switching Manual and permanent switching can be set using the menu in MANUAL or (in the automatic screen) by key combination (see fig). Manual control Reversing the channel status to the next automatic or programmed switching. Channel C1 Activate manual switching Briefly press both keys simultaneously. Activate permanent switching Simultaneously press both keys for 2 seconds. Cancelling manual/permanent switching Press both keys simultaneously. Permanent switching As long as a permanent switching (on or off) is activated, the programmed switching times are ineffective. 11

PIN code The PIN code is set in OPTIONS via the menu. If you have lost your PIN call the Hotline. OPTIONS OPERATING HOUR Operating hours counter LCD-ILLUMINA- TION The operating hours of the channel (relay) are displayed and deleted in the OPTIONS menu. If the number of operating hours exceeds the value set in the Service menu, SERVICE will appear in the display. Example: replace a light source after 5,000 h. Delete operating hours or increase the value set in service (e.g. to 10,000 h). LANGUAGE PIN FACTORY SETTING INFO ok END NO PIN WITH PIN CURRENT PIN NEW PIN 00 00 12

Technical data Nominal voltage: 230 240 V~, +10 %/-15 % Frequency: 50 60 Hz Gap: <3 mm Power consumption: type 4 VA Contact material: AgSnO 2 Contact: two way switch Switch output: phase-independent (zero-crossover switching) Suitable for switching SELV (Safe Extra-Low Voltage) Switching capacity: 16 A/250 V~ cos ϕ = 1 Switching capacity: 10 A/250 V~ cos ϕ = 0.6 Switching capacity min.: 10 ma/230 V AC 100 ma/12 V AC/DC Glow lamp load: 2600 W Halogen lamp load: 2600 W Fluorescent lamps (VVG low-loss series devices): uncorrected: 2300 VA Series corrected: 2300 VA parallel-corrected: 730 VA (80 µf) Lead-lag circuit (duo): 1000 VA Fluorescent lamps (EVG Electronic series devices): 650 W Mercury and sodium vapour lamps: parallel-corrected: 730 VA (80 µf) Compact fluorescent tubes (EVG): 22 x 7 W, 18 x 11 W, 16 x 15 W, 16 x 20 W, 14 x 23 W Permissible ambient temperature: 30 C... +55 C Protection class: II in accordance to appropriate installation Protection rating: IP 20 in accordance with EN 60529 Pollution degree: 2 Service address/hotline Schrack Technik GmbH www.schrack.com 13