Integre Pro Scan combines pattern scanning and multi-color photocoagulation in our unique all-in-one laser/slit lamp design.

Similar documents
The pattern scanning multi-color photocoagulator that puts you in control

Better diagnosis and treatment all-in-one.

VISULAS Trion. Treatment flexibility to the power of three. Multicolor Photocoagulation Laser

Lumenis Array LaserLink Pattern Scanning Laser Technology RETINA

Green Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500 US EDITION

KTP LASER. Photocoagulation System

Green Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500

Green Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500

577 nm: The Preferred Wavelength

The Fastest Photocoagulator.

Yellow Scan Laser Photocoagulator YLC-500 Vixi. Yellow Laser Photocoagulator YLC-500

Navigated Laser Therapy. A New Era in Retinal Disease Management

The First True Color Confocal Scanner on the Market

Impressive Wide Field Image Quality with Small Pupil Size

The First True Color Confocal Scanner

The First True-Color Wide-Field Confocal Scanner

EnFocus Your Upgrade Path to High Performance Intrasurgical OCT

CLARUS 500 from ZEISS HD ultra-widefield fundus imaging

CLARUS 500 from ZEISS HD ultra-widefield fundus imaging

Wide Angle Ophthalmoscope Instructions

Micropulse Duty Cycle. # of eyes (20 ms) Total spots (200 ms)

Optical Coherence Tomography Retina Scan Duo

CO 2 Laser. AcuPulse. with SurgiTouch. Automation System. An Evolution in Automated Laser Surgery. Surgical: AcuPulse CO 2 Laser

Headline. SL 130 Slit Lamp. Subline. Maximum quality for optimum performance

Basic Principles of the Surgical Microscope. by Charles L. Crain

Our vision is foresight

All-Glass Ophthalmic Lenses

High power and biostimulation laser therapy Polaris HP S

Light has some interesting properties, many of which are used in medicine:

CONTACT LENSES Discover a different world

Optical Coherence Tomography. RS-3000 Advance / Lite

High power and biostimulation laser therapy Polaris HP M

BETA Otoscopes & Ophthalmoscopes DIAGNOSTIC INSTRUMENTS

SLIT LAMP BQ 900 Sophisticated microscopy

Keeler Direct Ophthalmoscopes

Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY

Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Biophysical Basis of Optical Radiation Exposure Limits. Bruce E. Stuck

Litho DK30. Taking care of people, our masterpieces. State-of-the-art Desktop 30 W Holmium:YAG Laser. Surgery

you can See more with fundus autofluorescence. CR-2 PLUS NON-MYDRIATIC DIGITAL RETINAL CAMERA

OCT-A. Perimetry. Slit lamps. Retinal imaging OCOCTT. Microperimetry. Ultrasound. Lasers. HAAG-STREIT UK Product Portfolio

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Xenon-Diamond 2.9/106 With beam splitter

MEL 80 Excimer Laser. When you want to see better performance

Performance Meets Simplicity

White Paper: Modifying Laser Beams No Way Around It, So Here s How

Winter College on Optics: Trends in Laser Development and Multidisciplinary Applications to Science and Industry February 2013

EE119 Introduction to Optical Engineering Fall 2009 Final Exam. Name:

Beam Shaping and Simultaneous Exposure by Diffractive Optical Element in Laser Plastic Welding

Macro Varon 4.5/85. Key features. Applications. Web and surface inspections

P a n o r a m i c a n d C e p h a l o m e t r i c X - r a y s

Figure 1. Relative intensity of solar energy of different wavelength at the earth's surface.

plasmonic nanoblock pair

Veraviewepocs 2D High Speed Panoramic X-Ray Crystal Clear Images with Reduced Radiation

imagespectrum ADVANCED DIGITAL IMAGE MANAGEMENT SYSTEM Get a Better Handle on the Big Picture

Going beyond the surface of your retina

CR-2 AF DIGITAL NON-MYDRIATIC RETINAL CAMERA. Superior Image Resolution and Auto Functionality

HEINE QUALITY. :- HEINE Hand-held Ophthalmic Instruments

DIAGNOSTIC SKILLS AND TECHNIQUES

GRADE A ENGRAVING. Application-focused DPSS laser outshines industry favorite fiber laser counterpart when marking components

Optical Coherence Tomography. RS-3000 Advance

Laser Safety & the Human Eye Recall the human eye is a simple single lens system Crystalline lens provide focus Cornea: outer surface protection

COMPACT Diode Laser System (Water-Cooled)

HEINE mini 3000 Pocket Diagnostic Instruments Now Available with LED Illumination

What s Fundus photography s purpose? Why do we take them? Why do we do it? Why do we do it? Why do we do it? 11/3/2014. To document the retina

Instruments Commonly Used For Examination of the Eye

Xenon-Zirconia 3.3/92

ORTHOPANTOMOGRAPH OP 2D Quality and design

Maximizing clinical outcomes

Improving the Collection Efficiency of Raman Scattering

light iled: Milestones The world s leading LED surgical lights delivering unrivalled performance.

LumiBright TM LE 2400B-270

ioct Discover the next generation of efficiency enhancement

Tissue-Tek TEC 6 Embedding Console System

Optical Coherence Tomography. RS-3000 Advance / Lite

Silicon Avalanche Photodiode SAR-/SARP-Series

Specifications Summary 1. Array Size (pixels) Pixel Size. Sensor Size. Pixel Well Depth (typical) 95,000 e - 89,000 e -

MEDICARE GB LTD LIGHTING CATALOGUE. Approved Luxo Dealer

Kinder products for your most precious patients

Speckle Mitigation in Laser-Based Projectors

Training Eye Instructions

Physics 431 Final Exam Examples (3:00-5:00 pm 12/16/2009) TIME ALLOTTED: 120 MINUTES Name: Signature:

11/10/2015. Haag Streit Topcon Zeiss Kowa Add On Systems- OIS/Escalon and Others. The Original Design. Photo Slit lamp Systems. Who Makes Them?

FireFly Green. It is a self-contained laser that offers the user increased stability over a wide operating temperature and with a faster warm up time.

Specifications. Offers the best spatial resolution for multi-stripe spectroscopy. Provides the user the choice of either high accuracy slit mechanism

EE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name:

LaserBeam ProfilingSolutions. IRLaserBeam Profiler

LED Lighting Flux and Color Measurement System (LFC)

Tunable KiloArc. Tunable Broadband Light Source.

OCULAR MEDIA* PHOTOGRAPHIC RECORDING OF OPACITIES OF THE. development by the control of diabetes, the supply of a deficient hormone

This series of lasers are available with a choice of Nd:YAG, Nd:YLF, and Nd:YVO 4. System Reliability

Refractive Power / Corneal Analyzer. OPD-Scan III

NEWTOM GO 2D GREAT.VISION

DIGITAL IMAGING NON-MYDRIATIC FUNDUS CAMERA NM-1000

Optical Coherence Tomography. RS-3000 Advance / Lite

THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening

Biology 70 Slides for Lecture 1 Fall 2007

GE Healthcare. Performa. High-performance breast imaging

Transcription:

Integre Pro Scan combines pattern scanning and multi-color photocoagulation in our unique all-in-one laser/slit lamp design.

Multi-color scanning photocoagulation takes on a new look. Integre Pro Scan combines multi color photocoagulation and pattern scanning in our proprietary all-in-one laser/slit lamp design. Featuring a patented ZenTec laser cavity and an advanced optical system, Integre Pro Scan ensures precise titration and homogenous burns for predictable, consistent treatment outcomes.

A Pattern and Wavelength for Every Pathology 1 Unparalleled View of the Fundus Whether accurately positioning focal treatment in the macular area, or performing PRP in the periphery, Integre Pro Scan provides a pattern and wavelength for every pathology. The system offers a comprehensive array of pattern combinations: shape, size, and rotation can be fully customized in order to best meet your clinical requirements. Patterns of up to 37 spots can be delivered sequentially, as well as single spots. In addition, the system s computer-controlled operation ensures precise pattern spacing and consistent shaping of laser spots and patterns for more accurate, consistent treatment results. Integre Pro Scan also provides a number of wavelength configurations, including two dual-wavelength configurations. This includes a high-power yellow and red configuration that delivers the full treatment spectrum of a traditional three-color multi-color photocoagulator. Pattern Selection Integre Pro Scan incorporates a custom-built optical system that is optimized for use in the posterior segment. Featuring a 10-degree stereoscopic angle, it provides excellent depth perception and a wide peripheral view. In addition, achromatic doublet lens technology provides a clearer view of the fundus and an optimal red-reflex in order to better observe the tissue-effect allowing you to precisely titrate energy. As an added benefit, the combination of high-grade crown glass materials, multi-layered anti-reflection coatings and next-generation filter technology maximizes light transmission and provides an unparalleled color-balanced view of the retina. 2 Fast, Efficient Treatment Integre Pro Scan enables you to deliver a pattern of up to 37 spots in just 370 milliseconds, making it the industry s fastest pattern scanning photocoagulator. 3 Predictable Treatment Outcomes Featuring a proprietary ZenTec laser cavity manufactured from Square Rectangle Line Single Spot high-grade components with kinematic mountings, Integre Pro Scan continuously monitors and adjusts power output to deliver uniform energy distribution across the full diameter of the spot, eliminating hotspots and achieving optimal homogenous burns. Wedge Circle - empty Double Half Circle Circle - filled Wavelength Selection Yellow-Red Configuration (561 nm and 670 nm) Green-Red Configuration (532 nm and 670 nm) Yellow Configuration (561 nm) Green Configuration (532 nm)

MULTI-COLOR SCANNING PHOTOCOAGULATOR Control at Your Fingertips Integre Pro Scan offers a number of features designed to improve ease of use and maximize patient throughput, including: 1 Touchscreen Interface: easy, quick adjustment of all treatment parameters, including laser power, pulse duration, pattern selection and pattern size. The touchscreen can also be angled toward the patient to aid the consultative process. Ambidextrous Track Pad: easy navigation of the retina and adjustment of treatment parameters and pattern characteristics. Not only does this save you time, but it also allows you to perform treatment without the need to avert your eyes from the oculars. Second fiber port: connect a laser indirect ophthalmoscope (LIO). Range of pre-programmed lenses and a custom lens option, accessible via the touchscreen. Favorites Gallery: store preferred patterns for fast, easy recall. 5 5 Designed to Maximize Your Workflow 2 3 The all-in-one design of Integre Pro Scan channels the laser directly through the slit lamp optics. This integrated design minimizes system downtime, because there are no exposed fiber optic or electrical cables. It also provides a more ergonomic physician interface. This system significantly improves the process of laser treatment delivery. The improved ergonomics of the physician interface, together with its ease of maneuverability, enables even the most difficult situation to be managed such as a wheelchair-bound patient. Associate Professor Dimitri Yellachich, MD (Australia)

Accessories Track Pad The easy-to-use Track Pad allows adjustment of pattern size, position and orientation without the need to remove your eyes from the oculars. Power Control Footswitch (optional accessory) Adjust power levels while maintaining hands-on control of the slit lamp/laser without disturbing your view of the retina. Laser Indirect Ophthalmoscope (LIO) (optional accessory) Dual-color, lightweight-design based with coaxial laser beam and illumination. Connects to the second external fiber port. Total Solution Tables Configured to meet your needs, Integre Pro Scan can be combined with the Total Solution table range in order to meet the needs of ophthalmic offices, ambulatory surgery centers and hospital outpatient clinics. High-Visibility Eye Safety Filter (Motorized) Motorized eye safety filter features a custom high-quality coating for a clear, color-balanced view while ensuring optimal protection from the treatment beam. Wavelength Characteristics Product Specifications Laser Source solid-state laser diode and cavity (ZenTec ) Wavelength Power at the Cornea Exposure Time yellow-red configuration: 561 nm and 670 nm green-red configuration: 532 nm and 670 nm yellow configuration: 561 nm green configuration: 532 nm yellow: 50-1500 mw; red: 50-1000 mw; green: 50-1500 mw Single Spot: 0.01 to 8.0 seconds Pattern: 10, 20, 30 Patterns Linear (2 to 7 spots) Rectangle (2x3, 2x, 2x5, 2x6, 2x7) Square (2x2, 3x3, x, 5x5, 6x6) Triangle (3, 6, 10, 15, 21 and 28 spots) Circle - Filled (7, 12, 19, 27, 37 spots) Circle - Empty (12, 18, 2 and 30 spots) Single Half Circle (, 7 and 10 spots) Double Half Circle (11, 17 and 23 spots) Circle Sector 60 (3 to 7 spots) Circle Sector 120 (5, 7, 9 and 11 spots) Double Circle Sector 60 (5, 7, 9, 11 and 13 spots) Double Circle Sector 120 (8, 12, 16 and 20 spots) Variable Curve, Double Curve and Filled Sector 561 nm Yellow: maximal absorption in hemoglobin with negligible absorption in macular xanthophyll. 670 nm Red: deep, gentle penetration for effective treatment of choroidal vessels. 532 nm Green: the standard of care for common procedures, such as panretinal photocoagulation. Intended Use 10000 Spot Size Pattern: 100 to 500 µm, continuously variable Single Spot: 50 to 1000 µm, continuously variable Spot Spacing Pulse Duration Repeat Mode Aiming Beam Magnification 0 (touching), 0.25, 0.5, 0.75, 1.0, 1.25, 1.5, 1.75, 2.0 burn-width Pattern: 10, 20, 30 ms; Single Spot: 10 8000 ms Pattern: N/A; Single Spot: 50 1000 ms red 635 nm, adjustable intensity 6x, 10x, 16x, 25x, 0x Electrical Requirements 100 20 VAC, 50/60 Hz, 800 VA Weight Dimensions (HxWxD) 35kg, 71 lbs. (as shown) 62 x 76 x 7 cm, 2 x 30 x 19 inches (laser system only) Standard Accessories Tablet, Track Pad, Total Solution table, footswitch, dust cover, motorized eye safety filter, safety glasses, laser safety sign Retina Glaucoma Retinal Photocoagulation Laser Trabeculoplasty, Laser Iridotomy Optional Accessories LIO, Power Control footswitch, beam splitter, co-observation tube, 35mm camera adapter, video camera adapter, laser lenses Specifications are subject to change without notice. 2016, Ellex Medical Pty Ltd. Integre Pro Scan, Zen Tec, Total Solution and Power Control are trademarks of Ellex Medical Pty Ltd. Ellex is a registered trademark of Ellex Medical Pty Ltd. International patents pending and/or granted. E&OE. PB0018B. LASER CLASS DPSS: 561nm, 2W, 8 sec, CW (max) LASER CLASS DPSS: 532nm, 2W, 8 sec, CW (max) LASER CLASS DPSS: 532nm and 670nm, 2W, 8 sec, CW (max) LASER CLASS DPSS: 561nm and 670nm, 2W, 8 sec, CW (max) Headquarters 82 Gilbert Street Adelaide, SA, 5000 AUSTRALIA +61 8 810 5200 Japan -3-7 Miyahara F, Yodogawa-ku Osaka 532-0003 JAPAN +81 6 6396 2250 USA 7138 Shady Oak Road Minneapolis, MN, 553 USA 800 82 7 Germany ZPO Floor 1, Carl-Scheele-Str. 16 1289 Berlin GERMANY +9 30 6392896 00 Australia 82 Gilbert Street Adelaide, SA, 5000 AUSTRALIA +61 8 810 526 France La Chaufferie - 555 chemin du bois 6910 Rillieux la Pape FRANCE +33 8291 060