ASSESSMENT OF REINFORCEMENT CORROSION USING NONLINEAR ULTRASONIC SPECTROSCOPY

Similar documents
NON-LINEAR ULTRASONIC SPECTROSCOPY AS A TOOL TO EVALUATE BUILDING MATERIAL STRUCTURE DAMAGE

f n = n f 1 n = 0, 1, 2.., (1)

NDT OF FREEZE-THAW DAMAGED CONCRETE SPECIMENS BY NONLINEAR ACOUSTIC SPECTROSCOPY METHOD

*Department of Physics, ** Department of Building Structures, Faculty of Civil Engineering, Brno University of Technology

Experimental Study on Feature Selection Using Artificial AE Sources

INTERNAL CONCRETE INSPECTION AND EVALUATION METHODS FOR STEEL PLATE-BONDED SLABS BY USING ELASTIC WAVES VIA ANCHOR BOLTS

PLASTIC PIPE DEFECT DETECTION USING NONLINEAR ACOUSTIC MODULATION

Cutting Process Monitoring by Means of Acoustic Emission Method Part I New Approach of Acoustic Emission Sensor

DYNAMIC CHARACTERISTICS OF A BRIDGE ESTIMATED WITH NEW BOLT-TYPE SENSOR, AMBIENT VIBRATION MEASUREMENTS AND FINITE ELEMENT ANALYSIS

The Development of Laser Ultrasonic Visualization Equipment and its Application in Nondestructive Inspection

CENTER FOR INFRASTRUCTURE ENGINEERING STUDIES

VISUALISATION OF CORROSION ACOUSTIC SIGNALS USING QUALITY TOOLS

MEASUREMENT OF SURFACE DISPLACEMENT EXCITED BY EMAT TRANSDUCER

Detectability of kissing bonds using the non-linear high frequency transmission technique

Ultrasonic Guided Wave Testing of Cylindrical Bars

Keywords: Ultrasonic Testing (UT), Air-coupled, Contact-free, Bond, Weld, Composites

ASSESSMENT OF WALL-THINNING IN CARBON STEEL PIPE BY USING LASER-GENERATED GUIDED WAVE

1818. Evaluation of arbitrary waveform acoustic signal generation techniques in dispersive waveguides

Kissing bonds monitoring using nonlinear vibro-acoustic wave modulations

Reduction of Dispersive Wave Modes in Guided Wave Testing using Split-Spectrum Processing

Acoustic Resonance Analysis Using FEM and Laser Scanning For Defect Characterization in In-Process NDT

An instrument for detecting corrosion in anchorage zones of bridge cables using guided waves

VERSATILE USAGE OF ELECTROMAGNETIC ACOUSTIC TECHNOLOGIES FOR IN-LINE INSPECTION OF AGEING PIPELINES

Non-linear acoustics techniques for NDT

Comparison of natural frequencies of vibration for a bridge obtained from measurements with new sensor systeme

ULTRASONIC IMAGING of COPPER MATERIAL USING HARMONIC COMPONENTS

REFLECTION AND TRANSMISSION OF LAMB WAVES AT DISCONTINUITY IN PLATE Z. Liu NDT Systems & Services AG, Stutensee, Germany

vibro-acoustic modulation

Time Reversal FEM Modelling in Thin Aluminium Plates for Defects Detection

Experimental and theoretical investigation of edge waves propagation and scattering in a thick plate with surface-breaking crack-like defect

Available online at ScienceDirect. Physics Procedia 70 (2015 )

A STUDY ON NON-CONTACT ULTRASONIC TECHNIQUE FOR ON-LINE INSPECTION OF CFRP

New Instrument for Rock Bolt Inspection Using Guided Waves

Identification of Delamination Damages in Concrete Structures Using Impact Response of Delaminated Concrete Section

CONDITION MONITORING OF THRUST BALL BEARINGS USING CONTINUOUS AE

ULTRASONIC SPECTROSCOPY OF SILICON SINGLE CRYSTAL

Generation Laser Scanning Method for Visualizing Ultrasonic Waves Propagating on a 3-D Object

A NEW APPROACH FOR THE ANALYSIS OF IMPACT-ECHO DATA

Long Range Guided Wave Monitoring of Rail Track

INFLUENCE OF MEDIA DEGRADATION ON THE ANALYSIS OF ACOUSTIC EMISSION SIGNALS

Application of Ultrasonic Guided Wave to Heat Exchanger Tubes Inspection

Testing of Buried Pipelines Using Guided Waves

EFFECT OF SURFACE COATINGS ON GENERATION OF LASER BASED ULTRASOUND

저비용음압센서를이용한콘크리트구조물에서의비접촉 Impact-Echo 기반손상탐지

NONLINEAR ACOUSTICS FOR HEALTH MONITORING OF COMPOSITE PATCH REPAIRS

Nonlinear Ultrasonic Damage Detection for Fatigue Crack Using Subharmonic Component

Structural Health Monitoring of bridges using accelerometers a case study at Apollo Bridge in Bratislava

Diagnostics of Bridge Pavements by Ground Penetrating Radar

ACOUSTIC AND ELECTROMAGNETIC EMISSION FROM CRACK CREATED IN ROCK SAMPLE UNDER DEFORMATION

NARROWBAND ULTRASONIC SPECTROSCOPY FOR NDE OF LAYERED STRUCTURES T. Stepinski and M. Jonsson 1 Uppsala University, Uppsala, Sweden

Qualitative Measurement of Moisture Absorption in GFRP Utilizing Electromagnetic Induction

Challenges and New Developments for Air Coupled Ultrasonic Imaging

Modern Electromagnetic Equipment for Nondestructive Testing

The Analysis of Mechanical Vibrations and Acoustic Pressure Level of a Transformer Model

Absolute Calibration of Acoustic Emission Transducers as per CEN ISO/TR in Disuse of Mechanical Sound Sources or Reference Transducers

Imaging using Ultrasound - I

Modal damping identification of a gyroscopic rotor in active magnetic bearings

NONDESTRUCTIVE EVALUATION OF CLOSED CRACKS USING AN ULTRASONIC TRANSIT TIMING METHOD J. Takatsubo 1, H. Tsuda 1, B. Wang 1

TESTING A BINARY CRACK SENSOR USING A LABORATORY MODEL OF CRACKS IN STEEL GIRDERS

Extending Acoustic Microscopy for Comprehensive Failure Analysis Applications

DATA ANALYSIS FOR VALVE LEAK DETECTION OF NUCLEAR POWER PLANT SAFETY CRITICAL COMPONENTS

Ultrasonic Transmission Characteristics of Continuous Casting Slab for Medium Carbon Steel

EMBEDDED FBG SENSORS AND AWG-BASED WAVELENGTH INTERROGATOR FOR HEALTH MONITORING OF COMPOSITE MATERIALS

Experimental Research on Cavitation Erosion Detection Based on Acoustic Emission Technique

ULTRASONIC TRANSDUCER PEAK-TO-PEAK OPTICAL MEASUREMENT

ULTRASOUND IN CFRP DETECTED BY ADVANCED OPTICAL FIBER SENSOR FOR COMPOSITE STRUCTURAL HEALTH MONITORING

Acoustic-Laser Vibrometry for Standoff Detection of Defects in Materials

Rayleigh Wave Interaction and Mode Conversion in a Delamination

Detection and Assessment of Wood Decay in Glulam Beams Using a Decay Rate Approach: A Review

A Novel Crack Location Method Based on the Reflection Coefficients of Guided Waves

Finite element simulation of photoacoustic fiber optic sensors for surface rust detection on a steel rod

A minimum hydrophone bandwidth for undistorted cavitation noise measurement

Current based Normalized Triple Covariance as a bearings diagnostic feature in induction motor

Calculation and Comparison of Turbulence Attenuation by Different Methods

Microwave Measurement and Quantitative Evaluation of Wall Thinning in Metal Pipes

Professor Emeritus, University of Tokyo, Tokyo, Japan Phone: ;

Detection of crack in a concrete element by impact-echo method

Long Range Ultrasonic Testing - Case Studies

1409. Comparison study between acoustic and optical sensors for acoustic wave

GPR ANTENNA ARRAY FOR THE INSPECTION OF RAILWAY BALLAST

Reference wavelets used for deconvolution of ultrasonic time-of-flight diffraction (ToFD) signals

A SIMPLE METHOD TO COMPARE THE SENSITIVITY OF DIFFERENT AE SENSORS FOR TANK FLOOR TESTING

INVESTIGATION OF IMPACT DAMAGE OF CARBON FIBER- RAINFORCED PLASTIC (CFRP) BY EDDY CURRENT NON- DESTRUCTIVE TESTING

Analysis of metallic ropes magnetisation during magneto-inductive testing

IMAGING OF DEFECTS IN CONCRETE COMPONENTS WITH NON-CONTACT ULTRASONIC TESTING W. Hillger, DLR and Ing. Büro Dr. Hillger, Braunschweig, Germany

ACOUSTO-ULTRASONIC EVALUATION OF HYBRID COMPOSITES USING

Rotating Machinery Fault Diagnosis Techniques Envelope and Cepstrum Analyses

VD3-71 universal eddy current flaw detector application for field inspection of aeronautical engineering

MIRA Purpose MIRA Tomographer MIRA MIRA Principle MIRA MIRA shear waves MIRA

FATIGUE CRACK DETECTION IN METALLIC MEMBERS USING SPECTRAL

THE CONDUCTIVE ADHESIVE JOINS UNDER THERMAL SHOCKS. Ivana BESHAJOVA PELIKANOVA a

Research Collection. Acoustic signal discrimination in prestressed concrete elements based on statistical criteria. Conference Paper.

A simulation of vibration analysis of crankshaft

Theoretical and Experimental Investigation of Fiber Bragg Gratings With Different Lengths for Ultrasonic Detection

1. Introduction. 2. Mobile Ultrasonic Inspection System MUSE

Demagnetization of instrument transformers before calibration

PHASE DEMODULATION OF IMPULSE SIGNALS IN MACHINE SHAFT ANGULAR VIBRATION MEASUREMENTS

Determination of the Structural Integrity of a Wind Turbine Blade Using Ultrasonic Pulse Echo Reflectometry

Capabilities of Flip Chip Defects Inspection Method by Using Laser Techniques

Stethoscope-Based Detection of Detorqued Bolts Using Impact-Induced Acoustic Emissions

Transcription:

ASSESSMENT OF REINFORCEMENT CORROSION USING NONLINEAR ULTRASONIC SPECTROSCOPY Marta KORENSKA 1, Michal MATYSIK 1, Pavel VYROUBAL 1, Karel POSPISIL 2 1 Physics Department, Brno University of Technology; Brno, Czech Republic Phone: +420541147657; e-mail: korenska.m@fce.vutbr.cz, matysik.m@ fce.vutbr.cz, vyroubal.pavel@seznam.cz 2 Transport Research Centre; Brno, Czech Republic; e-mail: pospisil@cdv.cz Abstract Corrosion of built-in steel reinforcement ranks among the most serious mechanisms of bridge structure degradation. Visual inspection of a bridge cannot provide any information on the internal structure and integrity of the reinforced concrete elements of the bridge. This is why non-destructive diagnostic methods are acquiring growing importance, helping the researchers to evaluate properly the internal condition of a bridge. In this domain, methods employing the non-linear acoustic spectroscopy (NEWS Nonlinear Elastic Wave Spectroscopy) achieved rush advancement recently. These new non-destructive methods appear to be promising for application to a wide range of materials featuring relatively heavy non-homogeneities, and for a large span of sites, from micro-chip to bridge structures. The present paper deals with an experimental study of the application of non-linear ultrasonic spectroscopy methods to the detection of steel reinforcement corrosion and its consequences for reinforced concrete specimens subjected to corrosion induced degradation cycles. Keywords: Reinforced concrete, reinforcement corrosion, nonlinear ultrasonic spectroscopy, transfer characteristics, nonlinear effects 1. Introduction Bridge structures make an important element of the traffic infrastructure. In most cases they consist in reinforced or preloaded concrete structures originating from the second half of last century. Concrete proved to be a durable construction material in the past. However, concrete structures often experience degradation after years of service. One of the frequent breakdown causes consists in the steel reinforcement corrosion. There are cases where a bridge structure collapsed in consequence of the reinforcement corrosion. Redevelopment technologies have been experiencing a marked growth in foreign countries during last decades. In this country, thanks to the efforts of a number of renowned experts and professional societies a rapid development has come to fruition in this field, too. In this way, our building industry has almost reached the foreign standard. However, the absence of an acceptable, relatively fast and cheap monitoring method, which would be capable of detecting bridge faults at an early stage, thus making a simple and cost-effective maintenance possible, is still persisting. This is why a great attention is paid to the design and testing of new non-destructive methods meeting the above mentioned requirements. 2. Nonlinear Ultrasonic Spectroscopy There are two groups of methods available for application: resonance and nonresonance. Non-resonance methods are used to study suppressed resonance specimens. These methods analyse the effect of non-linearities on acoustic signals propagating

through them. These methods can be split into two groups. In the first group, a single ultrasound harmonic signal is employed. The non-linearity gives rise to additional signals featuring different frequencies according to Fourier expansion. In general, the amplitudes of these additional components decrease with the natural number n: f n = n f 1 n = 0, 1, 2... (1) Nevertheless, among the emerged signals, the third harmonic appears to be most pronounced, see Fig. 1. This is why the third harmonic amplitude is pursued by most researchers, especially in electronics (Hajek et. al., 2003). S i (f) S o (f) 0 f 1 f 0 f 1 2f 1 3f 1 4f 1 5f 1 f Figure1. Growth higher harmonic components in frequency spectra at transit pure harmonic signal through nonlinear environment with illustration of selection dominant third harmonic component by the frequency band-pass filter. In the second case, several (usually two) ultrasound signals are applied to the specimen. The number of additional harmonic components generated is substantially higher. In addition to both exciting signals harmonics, one gets also sum and difference frequency components. f v = ±m f 1 ±n f 2 m, n = 0, 1, 2... (2) The application domain of the ultrasound modulation spectroscopy splits into two subgroups, which differ from each another by the exciting frequency ratio. We pay attention to the frequency mixing principle is used. The signal frequencies are close to each other. The first difference component therefore falls into the low-frequency range as is shown Fig. 2. Figure 2. Creation of new harmonic components in frequency spectra at transit two harmonic signals through nonlinear environment with demonstration of selection dominant components by frequency filter - event of mixing (with small rate of f 2 /f 1 )

Recently, various papers on both the theoretical and experimental examination of diverse methods and their applicability in some fields have been published. Most published papers as well as our experience show these methods to be highly promising for the defectoscopy and the material testing purposes in the near future. One of the fields in which a wide application range of non-linear acoustic spectroscopy methods may be expected is civil engineering. Poor material homogeneity and, in some cases, shape complexity of some units used in the building industry, are heavily restricting the applicability of "classical" ultrasonic methods (Macecek, 2003). Precisely these non-linear acoustic defectoscopy methods are less susceptible to the mentioned restrictions and one may expect them to contribute to a great deal to further improvement of the defectoscopy and material testing in civil engineering. 3. Experiment 3.1 Tested Object and Experimental Arrangement Reinforced concrete joists of atypical dimensions of 50 mm 50 mm 360 mm, containing smooth steel bar of a diameter of 8 mm located in the joist longitudinal centre line, were studied in this experiment. Two mutual orientations of the ultrasonic transmitter sensor connecting line with respect to the specimen longitudinal centre line were selected for the measurements, namely, the transversal orientation 1 and the longitudinal orientation 2, as is shown in Fig. 3. A set of six specimens in two degradation process stages plus a set of three reference specimens were tested. Transversal orientation 1 Longitudinal orientation 2 Figure 3. A Location of the exciter and the sensor on the specimen under test In the first measurement stage, a single harmonic ultrasonic signal method was applied. The experimental set-up and testing of its component units have been described in detail previously (Manychova, 2007) and will be only briefly described here - Fig. 4. The measuring apparatus consists of two principal parts, namely, a transmitting section and a receiving and measuring section. The transmitting section consists of four functional blocks: a controlled-output-level harmonic signal generator, a low-distortion 100 W power amplifier, an output low-pass filter to suppress higher harmonic components and ensure high purity of the exciting harmonic signal. The main chain of the receiving section includes an input amplifier with filters designed to minimize the receiving chain distortion and a band-pass filter amplifier. Having been amplified, the sensor output signal was fed into a THPS3-25 HandyScope3 measuring instrument to be sampled and analyzed. For the purpose of improving the reliability and accuracy of the nonlinear experiments and minimizing the error effects the attention was focused to transmission between exciter and sensors. Elements meeting the given requirements were chosen (Korenska et. al., 2006). A program package to control the measuring

process, the data processing and evaluation makes an indispensable tool. The measurement results were represented in the form of frequency spectra. Figure 4. Experimental arrangement, photo of the nonlinear ultrasonic equipment with a test sample In the second experiment stage, a double-signal non-linear ultrasonic spectroscopy was applied, see Fig. 2. In the case of our experiment, the frequency difference fell into a frequency range below 5 khz. From the relatively high difference between the exciting signal frequencies and the difference component frequency there results a distinctive advantage of directly detecting this difference component, provided that an analogue high-dynamic-range (up to over 120 db) pre-filtering network is used. 3.2 Measurement results Generation of higher harmonic frequencies for an exciting frequency of f = 29 khz was studied in the first stage of experiment. The measurement results can be expressed in the form of frequency spectra, as is shown in following Figures. The spectrum of Fig. 5a) shows the measurement results obtained from a reference (intact) specimen measured under the conditions of transversal orientation. Higher harmonic amplitudes are decreasing with their increasing serial number. The surface area available for fitting the transmitter onto the specimen was restricted by the steel reinforcement in the case of longitudinal excitation. Therefore, a smaller sized high frequency exciter was used. The longitudinal orientation results are shown in Fig. 5b). This frequency spectrum shows again a drop of higher-frequency amplitudes with increasing serial number. Lower amplitudes, which were measured in the longitudinal orientation conditions, are due to the lower output of the HF exciter at the exciting frequency 29 khz.

Figure 5a. 05TP8C0 reference specimen - transversal orientation Figure 5b. 05TP8C0 reference specimen - longitudinal orientation Measurement results obtained after 82 corrosion cycles had been applied are shown in Fig. 6. The chart of Fig. 6a) corresponding to the transversal orientation contains not only the harmonic frequencies but also some other frequency components, whose amplitudes are comparable with those of the fourth (4H) and fifth (5H) harmonic frequency. The same effect was observed in light-concrete joists after they had been stressed in a pressing machine until a visible crack appeared (Matysik et. al., 2007, Korenska et. al. 2008). Figure 6a. 10TP8C82 specimen after 82 corrosion cycles - transversal orientation

The longitudinal-orientation transfer function curve differs from that of the intact specimen, see Fig. 6b). In the frequency spectrum the amplitudes of the odd-numbered harmonic frequency components 3H/5H exceed those of the even-numbered ones 2H/4H. Figure 6b. 10TP8C82 specimen after 82 corrosion cycles longitudinal orientation The next Fig. 7 and 8 represented the results of our measurement when two ultrasonic signals f 1 = 32 khz, f 2 = 29 khz have been applied on specimens. A difference component of a frequency f v = 3 khz was looked for. The chart of Fig. 7 corresponding to reference specimens. Figure 7. Reference specimen 05TP8C0 It is clear from the diagram that no inter-modulation of the two ultrasonic signal takes place, which gives evidence of the structure integrity of the specimen under test being intact. Measurement results of a specimen after 82 degradation cycles are represented in Fig. 8. The predominating magnitude of the amplitude occurring at this difference component is due to the presence of a defect in consequence of reinforcement corrosion.

Figure 8. Specimen after 82 cycles 10TP8C82 Further to the above mentioned measurements, X-ray photographs of the 05TP8C0 reference specimen and the 10TP8C82 specimen (after 82 corrosion cycle application) were taken, see Fig. 9. The upper photograph, denoted 08 and corresponding to the reference specimen, shows clearly that the reinforcement-to-concrete bond has remained intact. The lower photograph, denoted 8, illustrates the corroded specimen. In consequence of the corrosion, the reinforcement-to-concrete bond has been disturbed at several points along the reinforcement. One of the damaged areas is shown in the photograph. Figure 9. X-ray photographs of 05TP8C0 reference specimen (08) and 10TP8C82 specimen after 82 degradation cycles application (8). 4. Conclusion In the first stage of the experiment, with a single-frequency harmonic exciting signal, it has been proved that the frequency spectra of reference (non-corroded) specimens do not exhibit non-linearities in the signal transmission. On the other hand, transfer characteristics of the specimens measured after the application of 82 corrosion cycles do show non-linear effects, which correlate with the steel armature corrosion consequences. These non-linear effects are apparent for both transversal and longitudinal excitation arrangements from the relative high harmonic amplitude behaviour. The respective

amplitudes do not show the gradual decrease with the increasing harmonic order number, as is the case of the reference specimens. Moreover, the distorted structure showed to generate non-harmonic frequency components in the case of transversal excitation. When a double-frequency exciting signal method was applied, the consequences of the corrosion gave rise to a large-amplitude component whose frequency equalled to the exciting frequency difference. Following conclusions have been drawn from the application of the above mentioned methods: The single harmonic signal exciting method provides a very sensitive detection and accurate defect localization. However, it requires particularly in the case of bulky specimens a high exciting power, which is rather difficult to generate with the required spectrum purity. The double harmonic signal modulation method, using exciting signal whose frequencies near each other, does not require a pure signal spectrum, however, requires a certain degree of the source linearity to minimize mutual non-linear interaction. A certain drawback of this method consists in a rather low frequency of the exciting signal, which in its turn lowers the localisation potential of this method. In conclusion, it is to be noted that a mechanical impulse exciting signal carries much higher power than any pure harmonic signal electric excitation. The measurement sensitivity of such a measuring method is much higher. These methods are especially suitable for pronounced resonance response exhibiting specimens, where the broad-band impulse excitation results virtually in a narrow-band or even harmonic response. A typical example of pulse excitation used in everyday practice is a spectral analysis carried out by a human ear during a hammer-tap test of a railway wagon wheel, or the change in the sound spectrum of a broken bell. Beside the generation of new harmonic components, the defect induced non-linearity also results in a change of the specimen transfer characteristics and both phenomena can be analysed at a time. Acknowledgements The research described in this paper is being solved within framework of the project No. 103/09/1499 by the Grant Agency of the Czech Republic and of the research project of the Ministry of Education of the Czech Republic under contract No. MSM 0021630519. The authors would like to thank Mr. prof. Hobst for X-ray photographs of specimens and Mr. Skala for preparing the specimens for observation. References 1. Abeele, K. V. D., Carmeliet, J., Cate, J. A. T., Johnson, P. A., 2000. Nonlinear Elastic Wave Spectroscopy (NEWS) Techniques to Discern Material Damage. Part II: Single Mode Nonlinear Resonance Acoustic Spectroscopy. Res. Nondestr. Eval. 12/1, 31-42, 2000, http://perswww.kuleuve.ac.be/~u0004811/simonras.pdf. 2. Litwiller, R. G., 2002. Resonant Ultrasound Spectroscopy and the Elastic Properties of Several Selected Materials. http://www.kristall.ethz.ch/rigi2002/abstracts/abstractleisure.pdf. 3. Hajek, K., Sikula J., 2003. Testing of Low-Current Contacts Quality and Reliability by Using Third Harmonic Distortion. Proc. of 45th- IEEE Holm Conference, Washington, September 2003, p. 211-213. ISBN 0-7803-7862-8.

4. Macecek, M., 2003. Ultrasonic Concrete Testing, Defektoskopie 2003, 33rd International Conference, November 19-21, 2003, Ostrava, Czech Republic, pp.117-132. ISBN 80-214-2475-3. 5. Manychova, M., 2007. Measuring Setup for the Nonlinear Ultrasonic Spectroscopy Method. In Defektoskopie 2007, edited by M. Korenska et al., 37th International Conference Proceedings, Prague, 2007, pp. 147-151. ISBN 978-80-214-3504-9. 6. Korenska, M., Pazdera, L., Matysik, M., 2006. Testing of Pickups for Single-excitingsignal Non-linear Acoustic Spectroscopy. In Physical and Material Engineering 2006, International Workshop Proceedings, Slovak University of Technology in Bratislava, September 2006, pp. 70-75. ISBN 80-227-2467-X. 7. Matysik, M., Korenska, M., Plskova, I., Kucharczykova, B., Keprt, J., 2007. Application of the Non-linear Ultrasonic Spectroscopy Method to Lightweight Concrete Specimen Testing. In Proceedings of 5thWorkshop NDT 2007, Non-destructive Testing in Engineering Practice, November 29, 2007, Brno, p. 82-87. ISBN 978-80-7204-549-5. 8. Korenska, M., Matysik, M., Plskova, I., Manychova, M., 2008. Monitoring of Concrete Components Structure Condition Using a Nonlinear Ultrasonic Spectroscopy. Proceedings of the 17th World Conference on Nondestructive Testing, Shanghai, p. 6, CD, The e-journal of Nondestructive Testing, ndt.net, Germany, pp. 1-6, ISSN 1435-4934. 9. M. Korenska, L. Pazdera, K. Pospíšil, J. Stryk, P. Vyroubal: Detection of the Reinforcement Corrosion in Prestressed Concrete Girders. In Proceedings of The 8 th International Conference of the Slovenian Society for Non-destructive Testing, 1 3 September 2005, Portorož, Slovenia, pp. 317 322, ISBN 961 90610-5-5.