Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

Similar documents
Analog amplifier RA. RE Edition: Replaces:

Analog Amplifier RA. RE B/ Replaces: English. Instruction manual

Speed sensor DSA series 12

Plug-in amplifier. Table of contents. Features. RE 30264/07.12 Replaces: Type VT-SSPA1. Component series 2X 1/8

Valve amplifier for proportional valves. Type VT-SSPA1-1 (5, 50, 100, 150) Features. Contents. RE Edition: Replaces:

Electric amplifiers. Table of contents. Features RA 30052/ Model VT-VRPA1. Series 1X 1/6

Electric amplifier for proportional cartridge throttle valves

Valve amplifier for high-response valves. Type VT-VRRA X/V0/2STV, VT-VRRA X/V0/PO-IS. Contents. Features

Electric amplifiers. List of contents. Features. RE 30052/08.05 Replaces: Type VT-VRPA1. Unit series 1X 1/6

Electric amplifiers. Table of contents. Features. RE 30054/03.12 Replaces: Type VT-VRPA X/...-RTP. Component series 1X 1/6

Valve amplifier for proportional valves with electrical position feedback

Electric amplifiers. Table of contents. Features. RE 30052/02.12 Replaces: Type VT-VRPA X/V0/... Component series 1X 1/6

Analog amplifier. RE 29926/10.06 Replaces: Type VT Component Series 3X

Valve amplifier for proportional directional valves and proportional pressure valves. Type VT-VSPA2-1. Features. Contents

Electric amplifiers. Table of contents. Features. RE 30048/08.12 Replaces: Type VT-VRPA X/V0/RTP. Component series 1X 1/6

Valve amplifier for proportional valves. Type VT-MSPA2-1. Contents. Features. RE Edition: Replaces:

Electric amplifier for flow control with proportional

BODAS Controller RC Series 22

Valve amplifier for proportional pressure valves

Valve amplifier for proportional directional valves. Type VT-VRPA2. Features. Contents. RE Edition: Replaces: 07.05

Booster amplifier. Table of contents. Features. RE 30260/04.12 Replaces: Type VT-MSFA1. Component series 1X 1/6

Electronic amplifier for the control of proportional valves without position control Model VT 3024, Series 3X H/A 4149/94 VT X

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback

Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X

Analogue amplifier. Features. Table of contents. RE 29980/09.05 Replaces: Type VT-SR2. Series 1X 1/6

MRS ELECTRONIC DATASHEET CAN I/O AND PLC DESCRIPTION TECHNICAL DATA REGULATORY APPROVALS AND TESTING SOFTWARE/PROGRAMMING

4/3 proportional directional valve direct operated, with integrated electronics

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Mobile dual solenoid driver

p/q closed-loop control amplifier

Valve amplifier for proportional pressure valves

High-response valve with integrated digital axis controller (IAC-R) and field bus interface

BODAS Controller RC. RE Edition: Replaces: RC28-14/30 RC20-10/30 RC12-10/30

TECHNICAL DATASHEET #TDAX Universal Input, Single Output Valve Controller CAN (SAE J1939)

Smart Power Relay E I...

Analog position controller

Actuator LA12 PRODUCT DATA SHEET

RT-5005/5006/5007/5008

PowerPlex Compact Module PP-C-COM24

Digital amplifier for proportional valves PEM XD

Accessories Power Amplifiers

4/3 proportional directional valve with integrated digital electronics and field bus interface (IFB-P) Type 4WREF. Features.

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

Sensor technologies Distance measuring sensors Series SM6-AL. Brochure

EPA-M*** POWER AMPLIFIER FOR OPEN LOOP PROPORTIONAL VALVES SERIES 20

BODAS Controller RC10-10 Series 31

Speed sensors for general applications:

RA / /6. Replaces: Table of contents RA /06.98

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces:

Proportional Directional Control Valves Nominal sizes 16 and 25

Fuse, external A 6A, medium time lag. Power consumption W min 20 - max 60 (see paragraph 5.2) Output current A maximum 4.5 (see paragraph 5.

Sensor technologies Distance measuring sensors Series SM6-AL. Brochure

Service case with test unit for servo and proportional valves with integral electronics (OBE)

DENISON HYDRAULICS Proportional Pressure Control Valves

Sensor technologies Proximity sensors Series ST9. Brochure

EFC 3600 Frequency converter for higher energy efficiency and improved process control

MDSD (Series 2X) Mobile Dual Solenoid Driver

Drive Electronics pq11

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Drive electronics pq11

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

Electronic Air / Fuel Ratio Control System

POWER SYSTEM MODE STATUS

Controller. 1 Proportional amplifier module ESSK 103. ESSK 103 and ELSK Description. 1.2 Application examples. 1.

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Technical Documentation

Box chopper amplifier BOE

Proportional Directional Control Valves Size 6

ELECTRONIC REGULATOR FOR OPEN LOOP

Continental Hydraulics Installation Manual CEM-RA-A

Temposonics. E-Series Model ER. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. Analog and Start/Stop Outputs.

S5X Mobile Microcomputer. Technical Information 223,5 82,25 77,75 8,5 8,5 164,5 10,3. AMP Stecker AMP Connector 52,5 POWER SYSTEM MODE STATUS

Applications: oil and gas equipment automation; off-highway machine automation; agricultural equipment

Electronically controlled proportional pressure regulating valves

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

P/N: AX TECHNICAL DATASHEET #TDAX Single Input, Dual Output Valve Controller 1 Universal Input, +5V reference CAN (SAE J1939)

Pulse Scaler for DIN Rail Attachment

Proportional Directional Control Valves Size 6

high grade, temperature resistant plastic, Thermoplast with brass inserts

NOVOHALL Rotary Sensor touchless transmissive. Series RFX-6900

Absolute Encoders Multiturn

Pressure Transmitter SIL

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

58V signal frequency input analog input ( ma, PT1000. sensor) Programming System

TECHNICAL DATASHEET #TDAX INPUT, 12 OUTPUT VALVE CONTROLLER,

12 30 ripple included external fuse 3,0 A Current consumption A 1,0 2,6 depending from solenoid current. V ma. V ma. Output current A 1,0-1,6-2,6

TECHNICAL DATASHEET #TDAX CAN SAE J1939, Dual Output Valve Controller

NOVOHALL Rotary Sensor non-contacting. Series RSX-7900

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog

Temposonics. Magnetostrictive Linear Position Sensors. EP2 Analog Data Sheet

Amplifier / controller electronics

Penny & Giles No-Contact, Rotary Position Sensor NRH271 & NRH272

Product Data Sheet 3252J/2H3PU

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

EC 45 flat with integrated electronics Document ID: en Operating Manual

POSIROT. PRAS3EX Magnetic Angle Sensor. Magnetic Angle Sensors (Dust-Ex-proof) Datasheet

TECHNICAL DATASHEET #TDAX A DC MOTOR CONTROLLER P/N: AX Variable Speed Control, Onboard I/O CAN SAE J1939, Rugged Packaging

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T SSI Data Sheet

Transcription:

Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Analog Amplifier RA RE 95 230/03.06 1/12 replaces: RE 95 022 RE 95 023 RE 29 874 RE 29 875 Technical Data Sheet Series 10 for control of hydraulic components Contents Ordering Code 2 Material Numbers 2 Mating Connector 2 Description 3 Service Options 3 Technical Data 4 Curves 5 Block Circuit Diagram 6 Terminal Connection 7 Terminal Connection Variant 8 Unit Dimensions 9 Installation Position 10 General Information 11 Features The electronic analog amplifier activates up to two proportional solenoids and a switching function: Optional interlock of actuation for proportional solenoids Supply voltage for external setpoint potentiometer Monitoring of setpoint potentiometer for cable breakage and short circuit Externally actuated switching output Error output Separately adjustable ramp times Overload protection, overvoltage protection, conditional short-circuit protection Separately adjustable I min and I max for every solenoid Externally adjustable PWM frequency

2/12 Bosch Rexroth AG Analog Amplifier RA RE 95 230/03.06 Ordering Code Type Analog amplifier RA RA / 1 0 Design 1. digit = no. of proportional outputs 2-1 2. digit = no. of switching outputs 1-0 Series 1 Index 0 Material Numbers Analog amplifier RA Material number RA 2-1 / 10 R902091800 RA 1-0 / 10 R902091900 Mating Connector Order designation for Bosch 25-pin mating connector consisting of: Designation Material number Handle shell, angled Bosch 1 928 401 013 Contact carrier Bosch 1 928 400 952 Screw for contact carrier Bosch 1 928 491 082 Flat sealing ring for screws Bosch 1 928 300 198 Locking piece, lilac color Bosch 1 928 401 566 Clamping collar, large Bosch 1 928 400 890 2 screws for clamping collar Bosch 1 928 491 151 Sleeve, angled, 18 mm Bosch 1 928 300 284 Seal for contact carrier Bosch 1 928 300 191 Clamping band for sleeve Bosch 1 928 401 280 25 contacts AMP 927775-3 The mating connector is not included in supply. It is available from Rexroth with material number R902603063.

RE 95 230/03.06 Analog Amplifier RA Bosch Rexroth AG 3/12 Description The analog amplifier activates up to two proportional solenoids. The specified control voltage is processed in the amplifier as an input variable. The analog amplifier provides a regulated electric current as an output variable for actuation of proportional solenoids. Amplifier outputs for proportional solenoids are activated through a deadband of approx. 5% of the maximum setpoint voltage at the input, i.e. the minimum output current is applied. The level of this minimum output current can be adjusted separately for both proportional outputs using a trimming potentiometer. If the setpoint voltage at the input is increased, the output current for each respective proportional solenoid increases linearly. The maximum output current can also be separately adjusted using a trimming potentiometer for the outputs. The gradient of the output curve is influenced by this. The analog amplifier contains time ramp functions which can be used to adjust the period in which the output current can be adapted to match a modified setpoint. The ramp time adjustment range extends from 100 ms to 10 s. The time ramp functions can be adjusted using trimming potentiometers for each solenoid. Service Options The RA1 0/10 analog amplifier is used to actuate an individual proportional solenoid. The RA2 1/10 analog amplifier can be used to actuate two proportional solenoids in a single device (for example a toggling axial piston unit or a valve section with separate actuation of the proportional solenoids) or to actuate two devices independently of each other (for example two individual axial piston units or valves).

4/12 Bosch Rexroth AG Analog Amplifier RA RE 95 230/03.06 Technical Data Nominal voltage Residual ripple (DIN 40839, Section 1) Supply voltage, perm. range Current consumption without load with load, max. Fuse internal: external: for switching and proportional solenoid outputs and for electronics Potentiometer supply voltage (for setpoint potentiometer 2 5 kω) Voltage input (differential amplifier) (Setpoint voltage) 12 and 24 V max. ± 2 V 10 32 V ma A A T 0 V, 4.0 V 7.2 V 8.4 V (depending on load) RA1-0 150 3 3 RA2-1 4.0 V 1 2 Switch input > 5.0 V 1 Proportional solenoid outputs (PWM) Current range Pulse frequency 0 2.3 A 100, 200 or 350 Hz 150 6 7.5 1 2 Switch output (MOSFET) max. 1 A 1 LED indicators: red green yellow yellow Error detection Potentiometer: for broken wires and short circuit (with exception of wiper) Voltage supply: undervoltage monitoring Resistance to short circuits To supply voltage and ground for all inputs and outputs (Exception: potentiometer supply 4.0 V to supply voltage) Reverse polarity protection Supply/Battery Electromagnetic compatibility Spurious interference (motor vehicles directive 95/54/EG) Line-bound interference (ISO 7637-1/-2/-3) Load Dump Error (error indicatio)n Power (operating indicator) I1 (PWM current Channel 1) I2 (PWM current Channel 2) 100 V ms /m; (Details on request) Values on request Max. power loss W at 32 V 4 4 Operating temperature, case 40 85 C Storage temperature, case 40 85 C Vibration resistance Sinusoidal vibration (IEC 60086-2-6) Random vibration (IEC 60086-2-36) 70 V 10 g / 57 2000 Hz 20 cycles per axis 0.05 g 2 / Hz 30 min per axis

RE 95 230/03.06 Analog Amplifier RA Bosch Rexroth AG 5/12 Technical Data Shock resistance: Transport shock (IEC 60068-2-27) Continuous shock (IEC 60068-2-29) Resistance to moisture (IEC 60068-2-30Db; Variant II) Resistance to salt spray (IEC 60068-2-11) Type of protection (DIN / EN 60529): with mounted mating connector 1) 15 g / 11 ms 3x in each direction (pos./neg.) and in each axis 25 g / 6 ms 1000x in each direction (pos./neg.) and in each axis 90% (+25 C to +55 C) 72 h, 35 C, 5% NaCl RA1-0 Case material Plastic injection molding PA66 GF 35 Mass approx. kg 0.3 0.3 Outer dimensions IP65 1) where the connecting cable is laid suitably, see "Installation position" Length (in mm) Width (in mm) Height (in mm) 108 135 42 RA2-1 108 135 42 Curves For 2 solenoids with interlocked actuation (toggling mode) For 2 solenoids with independent actuation (parallel mode) I Solenoid ~0.8 x I max I max I Solenoid ~0.8 x I max I max Adjustment range Solenoid 2 Adjustment range Solenoid 1 Adjustment range ~0.06 x I max 0 V 4.0 V 8.5 V U setpoint I min ~0.06 x I max 4.0 V (0 V) I min 8.5 V (4.0 V) U setpoint

6/12 Bosch Rexroth AG Analog Amplifier RA RE 95 230/03.06 Block Circuit Diagram Supply voltage Solenoid 1 Current range switchover Voltage input Solenoid 1 Ramp off Potentiometer supply Solenoid 1 Error output Proportional solenoid output 1 PWM frequency On analog amplifier RA1-0/10 only the connections above this line are available Potentiometer supply Solenoid 2 Parallel mode Voltage input Solenoid 2 Proportional solenoid output 2 Supply voltage Solenoid 2 Switch input Switch output Key 1 Differential amplifier 2 Time ramp function 3 Reference voltage generation 4 LED operational status (Power) 5 LED displaying PWM current (I1 or I2) 6 PWM output stage Key 7 Internal voltage supply 8 Sensor or potentiometer supply 9 Clock-pulse generator 10 Switch output 11 Error detection 12 LED displaying error (Error)

RE 95 230/03.06 Analog Amplifier RA Bosch Rexroth AG 7/12 Terminal Connection Emergency Stop Ground Ignition lock with starter nonrepeat unit Supply PWM 1 U Bat Error 1) Frequency Pin 21 Bridge from 21 100 Hz open 200 Hz to GND to 2 or 12 Ramp off PWM frequency (see Table) Current range switchover PWM Output 350 Hz to U Bat to 19 Proportional solenoid Potentiometer 1 Differential input 1 Error output Sensor supply voltage Power supply for electronic circuits On analog amplifier RA1-0/10 only the connections above this line are available Potentiometer 2 Differential input 2 Supply PWM 2 PWM Output Proportional solenoid Parallel operation Open: Toggling UBat: Parallel operation Switch input Switch output 1) 3 connection options to switch over the PWM dither frequency (see Table): 100 Hz, 200 Hz, 350 Hz if required 2) Ground connection from solenoid return lead to battery (or chassis) possible 3) Separate ground connections from solenoid return lead to battery (or chassis) required; in the case of an inductive load, a freewheeling diode must be connected 4) 3A for RA1-0

8/12 Bosch Rexroth AG Analog Amplifier RA RE 95 230/03.06 Terminal Connection Variant (Additional terminal assignments available on request.) Toggling operation with single potentiometer If the analog amplifier RA2 1/10 is used in the toggling operation with just one potentiometer, then the potentiometer must be connected as per the following section: Sensor or potentiometer supply Differential input 1 Differential input 2 Parallel operation Open: Toggling operation Key 1 Analog input 1 (4.0 V 8.4 V): Setpoint (U setpoint ) for output signal amplifier 1 (solenoid 1) 2 Analog input 2 (4.0 V 0.0 V): Setpoint (U setpoint ) for output signal amplifier 2 (solenoid 2)

RE 95 230/03.06 Analog Amplifier RA Bosch Rexroth AG 9/12 Unit Dimensions

10/12 Bosch Rexroth AG Analog Amplifier RA RE 95 230/03.06 Installation Position The permissible installation position is with the plug positioned vertically downwards. The cable must be routed such that it lies completely or partially below the amplifier connection (see illustration). The IP65 type of protection is only achieved in the shown installation position in combination with a sealing of the connector relative to the wiring harness sleeve. Any ingress of water into the analog amplifier by way of the wiring harness must be avoided by routing the wiring harness accordingly.

RE 95 230/03.06 Analog Amplifier RA Bosch Rexroth AG 11/12 General Information Before commisioning the operating instructions is to be read! Project planning notes The total of setpoints for parallel wired potentiometers must lie in a range between 2 kω and 5 kω. Potentiometers with 4.7 kω or 5 kω are recommended. The externally actuated switch output can be used to actuate an additional device such as, e.g. for an emergency valve or a horn. Do not use a freewheeling diode in the solenoid line. Other inductive consumers in the system must be equipped with freewheeling diodes. External switching contacts in the solenoid lines are not permissible. Toggling or parallel mode is applied to Pin 9: Not connected: toggling mode, interlocked actuation of Solenoid 1 and Solenoid 2 wired with +U Bat : parallel mode, independent of each other actuation of Solenoid 1 and Solenoid 2 To switch off the time ramp function Pin 5 (Ramp off) must be connected. The PWM frequency of the output current is set by connecting Pin 21 (PWM frequency). The PWM output stages are supplied with voltage via Pin 19 (Solenoid 1) or Pin 20 (Solenoid 2) separately. Interruption of the supply voltage enables them to be switched off individually and independent from each other. Connection of Pin 24 (Dig In) activates switch output (Pin 7, Dig Out). Safety instructions In contrast to digital control units analog amplifiers only allow a limited diagnosis and monitoring capability. The use of an analog amplifier in applications in which in the event of a error hazardous machine states may arise, is therefore not permissible without additional external protective measures. If an analog amplifier develops a error i.e. unintended actuation or switching off of one or several solenoids then malfunctions cannot be reliably prevented. The suggested circuits do not imply any technical liability of Rexroth for the system. The safety instructions contained in RDE 90 301-01 must be observed. In emergency situations or a malfunction the operating voltage is to be externally interrupted. To this end, interruption of the electronic circuit s supply voltage is to be effected using an emergency stop switch. The emergency stop switch must be installed in an easily accessible position for the operator. Safe braking must be ensured when the emergency stop function is activated. To avoid malfunctions the lines shielded from and to the potentiometers are to be connected on one side with low-impedance to devices or vehicle ground. Cables to the electronics must not be routed close to other power-conducting cables in the machine or vehicle. A sufficient distance to radio systems must be maintained. All connectors must be unplugged from the electronics during electrical welding operations. The analog amplifier may only be wired up when in de-energized state. Cable connection must have a strain relief and be attached such that vibration will not cause any corrosion to the plug contacts. Contacts must be protected against corrosion. If the solenoid output is overloaded (short circuit) the relevant output is not constantly switched off. The two PWM outputs must not be connected to each other (bridged)!

12/12 Bosch Rexroth AG Analog Amplifier RA RD 95 230/03.06 Bosch Rexroth AG Hydraulics Product Segment Mobile Electronics Glockeraustraße 4 89275 Elchingen, Germany Telephone +49 (0) 73 08 82-0 Facsimile +49 (0) 73 08 72-74 info.brm-me@boschrexroth.de www.boschrexroth.com/mobile-electronics This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging. Subject to change.