Hult Center for the Performing Arts Technical Specifications

Similar documents
Plaza del Sol. Technical Specifications. Stage Rigging Schedule. California State University, Northridge. plaza del sol CONCERT HALL

AUDIO INVENTORY. Available as Front Fill Speakers Positioned evenly across the DS edge of stage 2 D&B V7P Speakers Available as Outer Fill Speakers

2016/2017 Technical Specifications. FOH Sound System. FOH Mains: 2- Meyer MSL-4 (1 Above, 1Below) + 1- Meyer DF-4P per side

Donald W. Reynolds Performance Hall Technical Information for Touring Companies

Hodgson Concert Hall Technical Information Packet 2017

Duncan Theatre Technical Specifications 6/16. Contact: Josh Schneider, Technical Director, , FAX

Jeanne and Peter Lougheed Performing Arts Centre

RiverCenter for the Performing Arts. House Sound System

TECHNICAL RIDER OCTOBER 2015

THE CLAYTON CENTER TECHNICAL INFORMATION PACKET

Donald W. Reynolds Performance Hall Technical Information for Touring Companies

REPERTORY THEATRE HOSTOS CENTER FOR THE ARTS & CULTURE

The Theater at Colorado Heights

HOLLYWOOD CENTRAL PERFORMING ARTS CENTER

Buffalo State Performing Arts Center SUNY Buffalo State 1300 Elmwood Ave. ROCK 210 Buffalo, New York 14222

THEATRE SPECIFICATIONS FOR WILLOW THEATRE

Always check availability of equipment Additional charges may apply PLEASE NOTE Stock availability may differ due to repairs etc

For more information please contact Bob Luffman at Ext or by at

TECHNICAL EQUIPMENT INFORMATION THE NORMAN ROTHSTEIN THEATRE Updated: November 2018

PSS A System Winter/Spring 2008

Tennessee Williams Theatre

Technical Specification 2017

JCCSF AUDIO INFORMATION - KANBAR HALL

PSS A System Summer 2009

OGRE Portugal Technical Rider

Campbell Heritage Theatre. Technical Information.

Theatre Technical Specifications

The Bridgewater Hall Technical Specifications

Technical Rider. Latest revision March 2017 ABBA-Salutely 70 s Show Director: Sammy Pawlak,

Technical Specifications Alhambra Stage

Jeanne and Peter Lougheed Performing Arts Centre

Surrey Civic Theatres Main Stage at Surrey Arts Centre Technical Information

Ramsey Recital Hall Technical Information Packet 2017 General Information:

Les Amazones d'afrique on tour 2017

MANDURAH PERFORMING ARTS CENTRE BOARDWALK THEATRE. Stage & Auditorium Specifications

Huntsville Algonquin Theatre AUDIO INVENTORY

Waterside. Robert Bolt Theatre. Technical Rider

NOTTINGHAM LAKESIDE ARTS DJANOGLY THEATRE TECHNICAL INFORMATION

MODEL DESCRIPTION QTY. PS15 NEXO PS15 R2 Single Cabinet 9. PS10 NEXO PS10 R2 Single Cabinet 6. RS18 NEXO RS18 Raysub 4

CONTACTS. Pantages Theatre 710 Hennepin Avenue Minneapolis, MN Steve Olson Operations Coordinator Phone: (612) Fax: (612)

J. W. ENNIS AUDITORIUM CENTENNIAL SECONDARY SCHOOL WELLAND, ONTARIO

Sound Technical Rider Yellow Umbrella 2017 Tour Problems with this rider? We can find a solution! Jörg: GSM:

III - SOUND RIDER Bixiga 70 European Tour 2017

Front-Of-House mixing desks: Monitor mixing desk: House speakers (main stacks): Allen & Heath GL4000. Allen & Heath GL4

RPA Sound hire prices 2015

Palm Beach State College Eissey Campus Theatre Last revised: Jan General Technical Specifications Stage Dimensions:

Robert Bolt Theatre. Technical Rider

LES TAMBOURS DU BRONX

The Crossing Venue Information & Specification 2013

FRONT HOUSE AND BACKSTAGE

N DI TECHNICAL RIDER PHOTO : SÉBA. imperialbell.com

DESCRIPTION OF FACILITIES

Concert Rider Clube do Balanço

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

TECHNICAL RIDER. 4. Dinner Dinner shall be after sound check. Please refer to Hospitality Rider for details.

Bedford Corn Exchange Main Auditorium Technical information

GECC Theatre Technical Specifications

Technical Specifications Alhambra Stage

Concert Hall_sound Stage. Light. Sound. Video. Back Stage. Stage. Light. Sound. Video. Back Stage. Stage. Light. Sound. Video. Back Stage.

Venue info Studentersamfundet, Trondheim, Norway

FOLKEN STORSALEN - FOH Production Specs - General Information

Technical specifications Short Format Subject to alteration-please call us to confirm details.

Biru Baby do not have their own sound engineer or lighting technician. In case of exceptions, we will let you know.

Fleck Dance Theatre Technical Specifications As of September 2014

See the lakeside website for up-to-date tech spec and drawings

Technical Specifications Alhambra Stage

TECHNICAL RIDER SALA BARTS BARCELONA ARTS ON STAGE. BARTS is a venue located at Barcelona city centre where most important theatres are.

Jockey Club Auditorium - Technical Information

Ex-Hire Used Equipment Price List

Bedford Corn Exchange main Auditorium

Jockey Club Auditorium - Technical Information

Ford Theaters Ford Amphitheater and [Inside] the Ford

Multi-Purpose Auditorium Sound Reinforcement System Design ECE Spring 2018 Group 4

Lismore City Hall Churchill Auditorium Technical Specifications

Ex-Hire Used Equipment Price List

Ex-Hire Used Equipment Price List

MULTI-PURPOSE AUDITORIUM SOUND REINFORCEMENT SYSTEM DESIGN ECE SPRING 2015 ANDREW PAWLING LUKE BOEHNLEIN KELLIE BOHLIG ROB LINGENFELTER

Peter Britt Festivals Audio Specification 2017

ECE40020 Venue Design. Sean Obrecht, Bryan Marquet, Aditya Sharma, Ben Capano

Dobson High School Auditorium

THÉÂTRE JEAN-DUCEPPE

Ex-Hire Used Equipment Price List

Technical Specifications

Monitor System. Microphone System. D.I Box AMPS KEYBOARD

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

Ex-Hire Used Equipment Price List

THÉÂTRE JEAN-DUCEPPE

Sinplus Up To Me (2014) Full Band - Technical Rider

Under The Radar Technical Rider

PINK TURTLE THEATRE RIDER

Summerhall Tech Specs 2018 Dissection Room

Impersonator Contest Technical Rider Page 1

Gusman Concert Hall Technical Rider

Last Updated January 2018

DROPS & POINTS by Pascal Schumacher feat. Maxime Delpierre

TECHNICAL RIDER AUDIO - MAINSTAGE F.O.H. CONSOLE F.O.H. DRIVE MONITOR SPEAKER MONITOR CONSOLE P.A. LINE ARRAY 4 WAY

Technical Rider (Audio)

June Swaner Gates Concert Hall Technical Information 2010 Edition

CAPACITY 650 Kapelstraat 13, 5401 EC Uden PHONE 0031 (0) FAX 0031 (0) IMPORTANT NOTES PROHIBITED SMOKING

NASYA TECH RIDER KUNAL WASON

Transcription:

Hult Center for the Performing Arts Technical Specifications Silva Concert Hall Technical Director, Brian Ference Asst Technical Director, Mike Carpenter.... Brian.R.Ference@ci.eugene.or.us Michael.C.Carpenter@ci.eugene.or.us Stage Specifications Proscenium: Stage Floor: Fly Rail: Soft Goods: Lighting System ' w x '" h (Arched) Plaster line to: Upstage wall ' / Downstage edge -" / Front row - ' Box booms - 0' / House sound position - ' / Follow spots- 0' / Balcony Rail - Center line to: Stage left wall - ' / Stage right wall - 0' Sprung plywood / black membrane, with black latex coating Good to excellent condition / no traps, ok to lag & screw into stage *NOT ok to lag or screw into far SL & SR apron Stage left / Single purchase counterweight - 00 lbs. per arbor Working line sets All battens ', with pickup lines High trim - ' / Low trim - ' st Elect is motor driven (LS #) All legs, borders, tabs, & travelers are black velour Legs: pair @'h x 'w Borders: @ 'h x 'w & @'h x 'w Tabs: @ 'h x 'w Black scrim: @ h x 'w White CYC: @ 'h x 'w Full stage thin blackout: @ 'h x 'w (guillotine only, single thickness/cotton) Upstage traveler- @ 'h x 'w (split at C/L) used as US X-Over Mid-stage traveler- @ 'h x 'w (split at C/L) ' from the plaster line E.T.C ION Board 0 dimmers, dimmer per circuit DMX access backstage - Lycian K 0 XLT (000w) Rosco gel available Company Switch: Lighting: Down stage right - 0' from downstage center Three x 00 amp, phase, wire "Y" Sound: Upstage right, 00 amp, phase, wire "Y" Upstage left, 00 amp, phase, wire "Y" *0 AMP Shore power for vehicles available Hult Center for the Performing Arts One Eugene Center, Eugene, Oregon 0 --0 www.hultcenter.org

Rev. // Sound System House PA: The Silva house system consists of a NEXO full range stereo system (Main s Left and Right), A NEXO front fill/center fill system and a NEXO four component cardioid sub array located at the top/center of the proscenium arch.the upper balcony and mezzanine is covered by NEXO full range speakers specifically focused at those areas( located left and right in the proscenium arch). All components are behind the acoustically transparent proscenium arch. See drawing. Maximum sound pressure allowable in Silva Hall (at house mix, 00 ' from stage apron) is DB (A), for periods not to exceed seconds. System is rated at a sensitivity of 0db @ watt @ meter and will reach a peak of 0db. Total power available (R.M.S.) is approximately,000 watts. Frequency response (at house mix location) is approximately 0 Hz > khz with the sub-lows in operation. System Components House Console: Sound Craft Vi - channels ( London Blu-0 processor ) FOH mix footprint typical 'd x 'w available without seat kills The Speaker System: - NEXO ALEF-C x 0 Full range speakers - NEXO ALEM-C x 0 Mid / Hi speakers - NEXO ALB--C LF speakers - NEXO GEOS 0 Front/Center Fill speakers - NEXO RS -CI Dual Sub Woofers YAMAHA DXR Front Fills Amplifiers: - NXAMPx / - NXAMP X Monitor System: Monitor Wedge Inventory: mixes available Please contact technical services staff if a monitor console will be needed for your event. Ten EAW SM00ih Two EAW SMe Monitors powered by Crown 00 amplifiers Two channel splitters compliment the system All stage audio patching is stage right Intercom: RTS (wired) HME DM00 (wireless) Loading dock: Loading dock located in alley up stage right at stage level. Push is to center line. A x concrete pad can accommodate trucks at a time. Roll up door is w x " h. There is a freight elevator adjacent to the dock for FOH, costumes, production and merchandise. Dressing Rooms: Total accommodations for approximately people Two star suites, each with sitting area, makeup room, and shower/restroom Four dressing rooms, lighted makeup mirrors, and sinks, for up to five people each Two chorus dressing rooms with lighted makeup mirrors, sinks and showers, for up to 0 people each

Silva Concert Hall Plan There are two sets of washers & dryers available. There is a small laundry room with two ironing boards

Silva Concert Hall Stage

Silva Concert Hall Section

0 0 0 Black Traveler Top 0 # # # # SL Box Booms 0 # # # # Silva Theatre - House Light Plot Designer: Drawn By Date Michael A. Peterson MC // Eugene, Oregon - Scale : ' = /" # # # # 0 0 0 0 00 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 F F F 0 E E E 0 0 D 0 D 0 D 0 0 0 0 0 0 0 0 0 SR Ladders # Leg 0 0 0 0 0 0 0 0 0 SL Ladders C 0 C 0 C 0 0 0 B 0 B 0 B 0 0 A 0 0 A 0 A 0 0 0 0 Cyc Strips 0 0 0 0 # Elect # Elect # Elect # Elect # Elect Plaster Line 0 0 0 Top 0 0 0 0 0 00 0 0 0 0 0 X Over Catwalk 0 0 Apron Fill Conductor Down Apron Fill # # # SR Box Booms # 0 0 0 0 0 0 0 0 0 st Cove 0 0 0 0 0 0 0 0 0 0 0 0 0 0 nd Cove Balcony Rail Symbols 0 0 Symbol Description Symbol Description Etc Source ETC Source- ETC Source- 0 ETC Source- 0 ETC Source NSI Colortran Cyc Strip Cell Key ETC Source- 0 0 0 0 0 FT Cyc Legs # Leg # Leg # Leg # Leg I- I- I- H- H- H- G- G- 0 G- F- F- F- E- E- E- D- D- D- 0 C- 0 C- 0 C- 0 B- 0 B- 0 B- 0 Cell Far Cycs A- 0 A- 0 Cyc A- 0 FT 0 0 0 0 0 0 0 FT 0 0 D0 Vivid 0 Unit Number Vivid Dimmer Channel FOLLOWSPOTS: LYCIAN K XLT0

SILVA LIGHTING INVENTORY 0 TYPE HOUSE HANG PURPOSE deg S Apron Wash - nd Cove 0 deg S Conductor Down deg S st Cove (0w) deg S Ladders - Box Booms - Balc Rail deg S Ladders - Box Booms - Tips deg S st > th Elect Fronts - Tips ETC D0 Vivid - LED Tops - Backs " Selador Vivid LED Strips Cyc Strips FarCyc ( Cell) th Elect CYC Wash S LED Lustr Series 0 Ground Row Lycian 0 XLT K Follow Spots SPARES Spare Source Bodies Spare Source Barrels deg S deg S deg S deg S ETC S Parnels ETC S Par FarCyc (Single cell) ETC D0's ( $0 ea per prod.) Gam twin spins ( slow - fast) Gobo Holders - A - B Molefay lights * please check with tech services on availablity of spares

Microphone Inventory 0 Type Avail Purpose Shure Beta Vocal Mics Shure SM Vocal Mics Sennheiser E 0 Vocal Mics Shure SM Audio Technica AE00 Condenser Vocal Shure SM Condenser Vocal Shure URD wireless systems Channels each - Wireless xmitters - Beta handheld UR ( w/ WL) lapel mics Audio Technica over ear mics Countryman E IOWBSL over ear mics Shure SM Instrument Sennheiser MD Instrument Sennheiser MD Instrument Shure Beta Condenser Kick Drum EV PL/RE0 Large Diaphram Shure SM Condenser Instr. Sennheiser MKH0 Condenser Instr. AKG B ULS Condenser Instr. AKG C0 Condenser Instr. AKG CB Condenser Instr. AKG C Condenser Instr. Audix SCZ Condenser Instr. Beyer M0 Ribbon Mic Beyer M00 Ribbon Mic Crown PCC 0 Floor Mic Crown CMW Choir Mics ( Omni) Countryman DI Active Direct Box Radial JDI MK DI Active Direct Box Radial ProAV Stereo DI Passive Direct Box

Hult Center Console and Outboard Inventory ' Equipment Make / Model # Silva Hall FOH Console > Sound Craft Vi Monitor EQ BSS FCS 0 Monitor EQ Audio Logic SC () FX TC M000 Multi FX CD Player Denon DN-C0 Soreng Theatre FOH Console > Sound Craft Expression House EQ dbx Monitor EQ Rane GQ0 CD Player Denon DN-000F FX Lexicon PCM 0 Compressor Symetrix Available for both halls Compressor Rane C Compressor Symetrix CL0 Compressor Drawmer DL channel EQ BSS Opal EQ EQ BSS Vari Curve EQ Rane PEQ Gate Rane G Spare Consoles > Yamaha LS