TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-10

Similar documents
TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-12

Description of Version

EMC TEST REPORT. According to

TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST CONDUCTED EMISSION TEST RADIATED EMISSION TEST 11

EMC Test report for LED Panel Light Models , , , , ,

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

EMC TEST REPORT. : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan. Taiwan

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

EMC VERIFICATION SUMMARY Report No.: SZHH

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST CONDUCTED EMISSION TEST RADIATED EMISSION TEST 10

EMC TEST REPORT : EGO-PZ001, EGO-PZ002, EGO-PZ003, EGO-PZ004, EGO-PZ005, EGO-PZ006, EGO-PZ007, EGO-PZ008

TEST REPORT... 1 CONTENT...

EMC TEST REPORT. For Shenzhen Scotle Technology Ltd CNC ROUTER. Model No.: HY-3040, HY-6040, HY-TB5, CNC 3040, CNC 6040, CNC 6090, CNC 1040, CNC 1325

EMC TEST REPORT CE TEST REPORT. Report Number : ETLE Report issue date: August 21, 2009

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

EMC TEST REPORT CE TEST REPORT. for Audio / Video receivers and associated equipment

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD

CE-EMC Test Report. United GULF GATE Trd. Co. MS EN 55032:2015 EN :2014 EN :2013 EN :2010+A1 :2015 JQL E

EMC Test Report. Report Number: M030826

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

ELECTRONICS TESTING CENTER(ETC), TAIWAN

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

EMC TEST REPORT. Report No.: CE10-LIE040101E

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

TABLE OF CONTENTS. Report Reference No.: GST E Issued: Oct. 21, 2011 Revised: None. Page 2 of 46

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

For the following Product : LED CONVERTER Model Name : OLW160P351N1A

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS

5.3 TEST SETUP AND PROCEDURE TEST DATA MEASUREMENT UNCERTAINTY FLICKER USED TEST EQUIPMENT...18

EMC test report AU01+E04

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

Page: 1 of 41 EMC TEST REPORT. Product Name : Multi-socket with surge protection : SPG3-B-10, SPG3-B-15, SPG3-B-5, SPG3-B-6

Test Report. Ningbo Goldmore Industrial Co.,Ltd.

Test Report GUANGDONG EAST POWER CO., LTD

TABLE OF CONTENTS Page 1 of VERIFICATION OF CONFORMITY SYSTEM DESCRIPTION PRODUCT INFORMATION SUPPORT EQUIPMENT

1 SUMMARY OF STANDARDS AND RESULTS

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

EMC TEST REPORT For CE

EMC TEST REPORT. For. Soma Medical (Sabah) Sdn Bhd ( D) UVGI AIR STERILIZER. Model No.: SM 20

PT. SARANA KARYA SOLUSINDO.

For the following Product : LED CONVERTER Model Name : OLW250P701N1A

EMC Measurement and Test Report. For. GlobTek, Inc. 186 Veterans Dr. Northvale, NJ USA. Power supply STR E. Damon Ma / Engineer

EMC TEST REPORT For MUST POWER LIMITED. Inverter. Model No.: PV18-5K MPK, PV18-5K PK, PV18-4K MPK, PV18-4K PK

Page: 1 of 46 EMC TEST REPORT : SISF, SISF-2, SISFN-BLACK, SISFN-2-BLACK

Declaration of Conformity.

2620 Modular Measurement and Control System

Revision History of Report

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT

Contents. Report No.: EMC-CE-2114 Page: 2 of 39

Guangdong East Power Co., Ltd. Uninterruptible Power Systems

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

AUSTRALIA TEST REPORT For. KLM Lighting Co., Limited. LED Down Light. Model No.: KLM-HP30WSN

EMC TEST REPORT. For PEAK ELECTRONIC(HUIZHOU)CO., LTD. DAB/FM radio Model No.: DB-318 Additional Model No.: DB-318B, DB-318C, DB-318R, DB-318U

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi

EMISSION. EN : 2006 Clause 6.5 Pass. Harmonic Current EN : 2006+A1: 2009+A2: 2009 Class A Pass

EMC TEST REPORT For. Global Tech China Limited. 120/200 Watt Mightylite. Model No.: Additional Model No: Please Refer To Page 57

EMC standards. Presented by: Karim Loukil & Kaïs Siala

Page: 1 of 44 EMC TEST REPORT. : Gembird Electronics Ltd. Room 1709, News Building, #2 Shennan Zhong Lu, Shenzhen, China

CE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

EMC TEST REPORT. Report No. : EM/2004/10096 Page : 1 of 19

FCC 47 CFR PART 15 SUBPART B TEST REPORT SHENZHEN EAGLE TECHNOLOGY CO., LTD Mirror photo booth Model No.: EAGMR

Test Report GUANGDONG EAST POWER CO., LTD

A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

FCC TEST REPORT On Behalf of GZTOD.CO., LTD The Multifunctional Platooninsert Model No.: YA30WSL-6AU6U

EMC TEST REPORT For Prokits Industries Co., Ltd.

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

TEST REPORT TEST REPORT. Report Number : ETLE Report issue date: May 26, Address : , Gongreung-dong, Nowon-gu, Seoul, Korea

CE EMC Test Report. Jones Tsai / Manager. SPORTON INTERNATIONAL (KUNSHAN) INC. No. 3-2, PingXiang Road, Kunshan, Jiangsu Province, P.R.C.

The standards relevant for the evaluation of EMC requirements are as follows:

SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

EN v3.1.1 TEST REPORT FOR. Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017

Report No R-RFCEP02V01. Test Report. Model No. MS-N012, U110, U115 Transmitter Module. MSI / MS-6890

CE TEST CERTIFICATION

C E R T I F I C A T I O N

Test Report. MS-1031,M640,6400,6400 series. Applicant MICRO-STAR INT L CO., LTD No.69,Li-De St,Jung-He City,Taipei Hsien 235,Taiwan

EMC TEST REPORT For TEA-Energy China Limited T8 LED Tube Model No.: T8-25W-150-ND-W-T00 Additional Model No: Please Refer To Page 58

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

Transcription:

TABLE OF CONTENTS 1. General Description of EUT 3 2. General Information of Test 4-6 3.1 Conducted Emission Tests 7-10 3.2 Radiated Emission Tests 11-13 3.3 Radiated Electromagnetic disturbance Test 14-18 3.4 Power Frequency Harmonics and Flicker Emission Tests 19-24 3.5 Electrostatic Discharge Immunity Test 25-27 3.6 Radiated, radio-frequency, electromagnetic field immunity test 28-29 3.7 Electrical fast transient/burst immunity test 30-31 3.8 Surge immunity test 32-33 3.9 Conducted immunity test 34-35 3.10 Voltage Dips and Short interruptions immunity test 36-37 4. EUT Photographs 38-40 Page Number : Page 2 of 40

1. General Description of EUT 1.1 Applicant Company Name : SoluM Co., Ltd. Address : Contact Person : Ki-Dong, Lee 150, Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16674 Republic of Korea E mail : kdlee007@solu-m.com Phone / FAX : TEL : +82-31-8006-7677 FAX : - 1.2 Manufacturer Company Name : SoluM Co., Ltd. Address : Contact Person : Ki-Dong, Lee 150, Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16674 Republic of Korea E mail : kdlee007@solu-m.com Phone / FAX : TEL : +82-31-8006-7677 FAX : - 1.3 Basic Description of EUT Trade Name : Product Name : LED CONVERTER Model Name : SLW320N571N1A ADD Model : SLW230N421N1A, SLW320N571N1E Serial Number : Prototype Test Voltage : AC 230 V, 50 Hz Rating : Input: AC (100-250) V, (50/60) Hz, MAX 0.45 A, 35 W Output: DC (23-50) V, 0.57 A, 28 W Page Number : Page 3 of 40

2. General Information of Test 2.1 Test Facility This test was carried out by BWS TECH Inc. Test Site Location : 23, Gokhyeon-ro 480 Beon-gil, Mohyeon-myeon, Cheoin-gu, Yongin-si, Gyeonggi-do 449-853, Korea TEL : 82-31-333-5997 FAX : 82-31-333-0017 2.2 Standard for Methods of Measurement Basic Standard Description Test Result EN 55015:2013 EN 61547:2009 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment Equipment for general lighting purposes EMC immunity requirements Pass Pass Fail Fail EN 61000-3-2:2014 Mains harmonics equipment up to 16A. Pass Fail EN 61000-3-3:2013 Voltage fluctuations equipment up to 16A. Pass Fail EN 61000-4-2:2009 EN 61000-4-3:2006+A2:2010 EN 61000-4-4:2012 Testing and measurement techniques. Electrostatic discharge immunity test. Testing and measurement techniques. Radiated Immunity. Testing and measurement techniques. Electrical fast transient/burst immunity test. EN 61000-4-5:2014 Testing and measurement techniques. Surge immunity test. Pass Fail EN 61000-4-6:2014 Testing and measurement techniques. Immunity to conducted disturbances induced by Pass Fail radio frequency fields. EN 61000-4-8:2010 Testing and measurement techniques. Power frequency magnetic field Immunity Test. N/A #Note 1 EN 61000-4-11:2004 Testing and measurement techniques. Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests. Pass Fail #Note 1. This test was excluded, because EUT was not containing any devices susceptible to magnetic fields. 2.3 Description of EUT Modification - N/A 2.4 Variations covered by this report - N/A 2.5 Additional information related to Testing Test results apply only to the particular sample tested and functionality described in this test report. This report may be reproduced in full. Partial reproduction may only be made with the written permission of the BWS Tech Inc. Pass Pass Pass Fail Fail Fail Page Number : Page 4 of 40

2.6 Model Difference Basic Model is SLW320N571N1A - Variant Models are SLW230N421N1A, SLW320N571N1E. Additional models derived by the buyer s request. 2.7 Test Conditions EUT Operating Mode EUT was tested according to the following operation modes provided by the specifications given by the manufacturer, and reported the worst emissions. Operation Modes Worst Case Mode Normal Operation Mode Performance Criteria A) Performance Criterion A During the test, no change of the luminous intensity shall be observed and the regulating control, if any, shall operate during the test as intended. B) Performance Criterion B During the test, the luminous intensity may change to any value. After the test, the luminous intensity shall be restored to its initial value within 1 min. Regulating controls need not function during the test, but after the test the mode of the control shall be the same as before the test provided that during the test no mode changing commands were given. C) Performance Criterion C During and after the test, any change of the luminous intensity is allowed and the lamp(s) may be extinguished. After the test, within 30 min, all functions shall return to normal, if necessary by temporary interruption of the mains supply and/or operating the regulating control Page Number : Page 5 of 40

Test System layout on EUT and peripherals Interface cable Power cable JIG LED EUT 2.8 Description of Test System (EMI and EMS) Type of Peripheral Equipment Used: Description Model Name Serial No. Manufacturer EUT SLW320N571N1A Prototype SoluM Co., Ltd. LED N/A N/A N/A JIG N/A N/A N/A Type of Cables Used: Device from I/O Port Device to I/O Port Length(m) Type of Shield EUT JIG AC IN Power Socket - 1.0 Unshielded DC OUT LED DC IN 0.3 Unshielded - EUT - Direct - - LED - Direct - Page Number : Page 6 of 40

3.1 Conducted Emission Tests Conducted Emissions were measured from 9 khz to 150 khz with a bandwidth of 200 Hz, 150 khz to 30 MHz with a bandwidth of 9 khz on the 230 V AC power and return leads of the EUT according to the methods defined in European Standard EN 55015:2013 Clause 8. The EUT was placed on a nonmetallic stand in a shielded room 0.8 meters above the ground plane as shown in section 3.1.5. The interface cables and equipment positioning were varied within limits of reasonable applications to determine the position producing maximum conducted emissions. 3.1.1 Test Condition 3.1.2 Test Standard Frequency Range of Test : 9 khz to 30 MHz Test Standard : EN 55015:2013 Test Date : 13 January 2017 Temperature/Humidity : 16 C / 37 % R.H. Item Main Terminal Frequency Range Limit db(uv) (MHz) Quasi-Peak Average-Peak 0.009-0.05 110-0.05-0.15 90 to 80-0.15-0.5 66 to 56 56 to 46 0.5-5.0 56 46 5.0-30 60 50 Item Control Terminal Frequency Range Limit db(uv) (MHz) Quasi-Peak Average-Peak 0.15-0.5 84 to 74 74 to 64 0.5-30 74 64 3.1.3 Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use EMI Test Receiver ESPI ROHDE & SCHWARZ 100063 01. 05. 2018 LISN LN2-16N EMCIS LN16004 03. 24. 2017 Page Number : Page 7 of 40

3.1.4 Test Result of Conducted Emission EUT : SLW320N571N1A Input Voltage : AC 230 V, 50 Hz Test Mode : L1 Conducted Emission Test Results: PASS Test data sheets follow. Conducted Emission Test Data Page Number : Page 8 of 40

EUT : SLW320N571N1A Input Voltage : AC 230 V, 50 Hz Test Mode : N Conducted Emission Test Results: PASS Test data sheets follow. Conducted Emission Test Data Notes 1. Margin = Limit - Emission Level 2. All modes of operation were investigated and the worst-case emissions are reported. See the plots in next pages. 3. Measurement uncertainty estimated at 3.72 db. The measurement uncertainty is given with a confidence of 95 % with the coverage factor, k = 2. Page Number : Page 9 of 40

3.1.5 Photographs of Conducted Emission Test Configuration [Conducted Emission Test-Main Terminals] Page Number : Page 10 of 40

3.2 Radiated Emission Tests Radiated emissions form 30 MHz to 300 MHz were measured with a bandwidth of 120 khz according to the methods defines in EN 55015:2013. The EUT was placed on a nonmetallic stand in the 10 m chamber, 0.8 meter above the ground plane, as shown in section 3.2.5. The interface cables and equipment positions were varied within limits of reasonable applications to determine the positions producing maximum radiated emissions. 3.2.1 Test Condition Frequency Range of Test : 30 MHz to 300 MHz Test Standard : EN 55015:2013 Test Date : 13 January 2017 Temperature/Humidity : 19 C / 25 % R.H. 3.2.2 Test Standard Frequency Range (MHz) Limit (dbuv) Quasi-Peak 30 ~ 230 30 230 ~ 300 37 3.2.3 Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Bilog Antenna VULB 9160 SCHWARZBECK 9160-3052 10. 06. 2017 EMI Test Receiver ESR ROHDE & SCHWARZ 101320 03. 25. 2017 RF AMPLFIER MPA-10-40 RF Bay 21163921 10. 10. 2017 Antenna Mast ( 4 m) AM 4.0 MATURO Positioner Controller CO2000 MATURO AM4.0/225/17 240915 NCU/459/172 40915 N/A N/A Page Number : Page 11 of 40

3.2.4 Test Result of Radiated Emission EUT : SLW320N571N1A Test distance : 10 m Radiated Emission Test Results : PASS Test data sheets follow. Radiated Emission Test Data Notes 1. * H : Horizontal polarization, ** V : Vertical polarization 2. Margin value = Emission Level Limit (Quasi-Peak) 3. Corr. = Correction factor (Antenna factor + Cable loss AMP gain) 4. Measurement uncertainty estimated at 5.49 db. The measurement uncertainty is given with a confidence of 95 % with the coverage factor, k = 2. Page Number : Page 12 of 40

3.2.5 Photographs of Radiated Emission Test Configuration [Radiated Emission Test] Page Number : Page 13 of 40

3.3 Radiated Electromagnetic disturbance Test Radiated emissions form 9 khz to 30 MHz were measured with a bandwidth of 200 Hz, 9 khz according to the methods defines in EN 55015:2013. The EUT was placed on a nonmetallic stand as shown in section 3.3.5. 3.3.1 Test Condition Frequency Range of Test : 9 khz to 30 MHz Test Standard : EN 55015:2013 Test Date : 13 January 2017 Loop Antenna Size : 2 m Temperature/Humidity : 16 C / 36 % R.H. 3.3.2 Test Standard Frequency Range (MHz) Quasi-Peak Limit (dbuv) Average-Peak 0.009-0.07 88 N/A 0.07-0.15 88 to 58 N/A 0.15-3.0 58 to 26 N/A 3.0-30 22 N/A 3.3.3 Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Loop Antenna HXYZ 9170 SCHWARZBECK HXYZ9170-215 N/A EMI Test Receiver ESPI ROHDE & SCHWARZ 100063 01. 05. 2018 Page Number : Page 14 of 40

3.3.4 Test Result of Radiated Emission EUT : SLW320N571N1A Loop Antenna Size : 2 m Test mode : X-axis Radiated Electromagnetic disturbance Test Results: PASS Test data sheets follow. Radiated Electromagnetic disturbance Test Data Page Number : Page 15 of 40

EUT : SLW320N571N1A Loop Antenna Size : 2 m Test mode : Y-axis Radiated Electromagnetic disturbance Test Results: PASS Test data sheets follow. Radiated Electromagnetic disturbance Test Data Page Number : Page 16 of 40

EUT : SLW320N571N1A Loop Antenna Size : 2 m Test mode : Z-axis Radiated Electromagnetic disturbance Test Results: PASS Test data sheets follow. Radiated Electromagnetic disturbance Test Data Notes 1. Margin value = Limit - Emission Level 2. All other emissions not reported were more than 25 db below the permitted limit. 3. Measurement uncertainty estimated at 2.99 db. The measurement uncertainty is given with a confidence of 95 % with the coverage factor, k = 2. Page Number : Page 17 of 40

3.3.5 Photographs of Radiated Electromagnetic disturbance Test. [Radiated Electromagnetic disturbance Test] Page Number : Page 18 of 40

3.4 Power Frequency Harmonics and Flicker Emission Tests 3.4.1 Test Procedure Power Frequency Harmonics Tests : The measured values of the harmonics components of the input current, including line current and neutral current, shall be compared with the limits given in Clause 7 of EN 61000-3-2:2014 Flicker Emission Tests : The total impedance of the test circuit, excluding the appliance under test, but including the internal impedance of the supply source, shall be equal to the reference impedance. The stability and tolerance of the reference impedance shall be adequate to ensure that the overall accuracy of 8 % is achieved during the whole assessment procedure. 3.4.2 Test Condition EUT : SLW320N571N1A Test Standard : EN 61000-3-2:2014 EN 61000-3-3:2013 Test Date : 13 January 2017 Device Class : C Temperature/Humidity : 21 C / 37 % R.H. 3.4.3 Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Compliance Test System PACS-1 California Instruments 71980 N/A AC Power Source 5001IX California Instruments 54549 01. 05. 2018 3.4.4 Test Result of Power Frequency Harmonics and Flicker Emission Tests Power Frequency Harmonics : PASS Flicker Emission Tests : PASS Page Number : Page 19 of 40

V o l t a g e ( V o l t s ) Harmonics Class-C (Run time) EUT: SLW320N571N1A Tested by: BWS TECH Inc. Test category: Class-C (European limits) Test Margin: 100 Test duration (min): 3 Customer: SoluM Co., Ltd. Test Result: Pass C u r r e n t ( A m p s ) Current & voltage waveforms C u r r e n t R M S ( A m p s ) 0. 3 0. 2 0. 1 0. 0-0. 1-0. 2-0. 3 Harmonics and Class C limit line 0. 0 6 0. 0 5 0. 0 4 0. 0 3 0. 0 2 0. 0 1 0. 0 0 Source qualification: Normal European Limits 300 200 100 0-1 0 0-2 0 0-3 0 0 4 8 12 16 20 24 28 32 36 40 H a r m o n i c # Test result: Pass Worst harmonics H5-48.69% of 100% limit, H5-32.82% of 150% limit. Page Number : Page 20 of 40

Current Test Result Summary (Run time) EUT: SLW320N571N1A Tested by: BWS TECH Inc. Test category: Class-C (European limits) Test Margin: 100 Test duration (min): 3 Customer: SoluM Co., Ltd. Test Result: Pass Source qualification: Normal THC(A): 0.01 I-THD(%): 7.63 POHC(A): 0.000 POHC Limit(A): 0.013 Highest parameter values during test: V_RMS (Volts): 229.76 Frequency(Hz): 50.00 I_Peak (Amps): 0.236 I_RMS (Amps): 0.137 I_Fund (Amps): 0.136 Crest Factor: 1.717 Power (Watts): 30.8 Power Factor: 0.975 Harm# Harms(avg) 100%Limit %of Limit Harms(max) 150%Limit %of Limit Status 2 0.000 0.003 0.0 0.000 0.004 0.00 Pass 3 0.008 0.040 20.1 0.008 0.060 13.47 Pass 4 0.000 5 0.007 0.014 48.7 0.007 0.020 32.82 Pass 6 0.000 7 0.003 0.010 0.0 0.003 0.014 0.00 Pass 8 0.000 9 0.003 0.007 0.0 0.003 0.010 0.00 Pass 10 0.000 11 0.003 0.004 0.0 0.003 0.006 0.00 Pass 12 0.000 13 0.001 0.004 0.0 0.001 0.006 0.00 Pass 14 0.000 15 0.001 0.004 0.0 0.001 0.006 0.00 Pass 16 0.000 17 0.001 0.004 0.0 0.001 0.006 0.00 Pass 18 0.000 19 0.000 0.004 0.0 0.000 0.006 0.00 Pass 20 0.000 21 0.001 0.004 0.0 0.001 0.006 0.00 Pass 22 0.000 23 0.000 0.004 0.0 0.000 0.006 0.00 Pass 24 0.000 25 0.001 0.004 0.0 0.001 0.006 0.00 Pass 26 0.000 27 0.001 0.004 0.0 0.001 0.006 0.00 Pass 28 0.000 29 0.000 0.004 0.0 0.000 0.006 0.00 Pass 30 0.000 31 0.000 0.004 0.0 0.000 0.006 0.00 Pass 32 0.000 33 0.000 0.004 0.0 0.000 0.006 0.00 Pass 34 0.000 35 0.000 0.004 0.0 0.000 0.006 0.00 Pass 36 0.000 37 0.000 0.004 0.0 0.000 0.006 0.00 Pass 38 0.000 39 0.000 0.004 0.0 0.000 0.006 0.00 Pass 40 0.000 Note: Dynamic limits were applied for this test. The highest harmonics values in the above table may not occur at the same window as the maximum harmonics/limit ratio. Page Number : Page 21 of 40

Voltage Source Verification Data (Run time) EUT: SLW320N571N1A Tested by: BWS TECH Inc. Test category: Class-C (European limits) Test Margin: 100 Test duration (min): 3 Customer: SoluM Co., Ltd. Test Result: Pass Source qualification: Normal Highest parameter values during test: Voltage (Vrms): 229.76 Frequency(Hz): 50.00 I_Peak (Amps): 0.236 I_RMS (Amps): 0.137 I_Fund (Amps): 0.136 Crest Factor: 1.717 Power (Watts): 30.8 Power Factor: 0.975 Harm# Harmonics V-rms Limit V-rms % of Limit Status 2 0.102 0.459 22.12 OK 3 0.494 2.068 23.91 OK 4 0.019 0.459 4.17 OK 5 0.035 0.919 3.78 OK 6 0.017 0.459 3.79 OK 7 0.027 0.689 3.94 OK 8 0.015 0.459 3.24 OK 9 0.026 0.459 5.76 OK 10 0.012 0.459 2.66 OK 11 0.012 0.230 5.43 OK 12 0.022 0.230 9.52 OK 13 0.015 0.230 6.45 OK 14 0.012 0.230 5.27 OK 15 0.009 0.230 3.84 OK 16 0.011 0.230 4.61 OK 17 0.015 0.230 6.67 OK 18 0.014 0.230 6.02 OK 19 0.012 0.230 5.42 OK 20 0.014 0.230 6.01 OK 21 0.009 0.230 3.99 OK 22 0.008 0.230 3.44 OK 23 0.007 0.230 3.20 OK 24 0.007 0.230 2.94 OK 25 0.010 0.230 4.53 OK 26 0.008 0.230 3.49 OK 27 0.007 0.230 3.22 OK 28 0.007 0.230 2.90 OK 29 0.006 0.230 2.53 OK 30 0.007 0.230 2.85 OK 31 0.005 0.230 2.17 OK 32 0.005 0.230 2.15 OK 33 0.006 0.230 2.75 OK 34 0.003 0.230 1.16 OK 35 0.004 0.230 1.70 OK 36 0.005 0.230 2.06 OK 37 0.005 0.230 2.02 OK 38 0.003 0.230 1.23 OK 39 0.004 0.230 1.58 OK 40 0.010 0.230 4.16 OK Page Number : Page 22 of 40

1 3 : 5 6 : 3 4 Flicker Test Summary per EN/IEC61000-3-3 (Run time) EUT: SLW320N571N1A Tested by: BWS TECH Inc. Test category: All parameters (European limits) Test Margin: 100 Test duration (min): 10 Customer: SoluM Co., Ltd. Test Result: Pass Status: Test Completed Psti and limit line European Limits P s t 1. 0 0 0. 7 5 0. 5 0 0. 2 5 Parameter values recorded during the test: Vrms at the end of test (Volt): 229.66 Highest dt (%): 0.00 Test limit (%): 3.30 Pass Time(mS) > dt: 0.0 Test limit (ms): 500.0 Pass Highest dc (%): 0.00 Test limit (%): 3.30 Pass Highest dmax (%): 0.00 Test limit (%): 4.00 Pass Highest Pst (10 min. period): 0.064 Test limit: 1.000 Pass Page Number : Page 23 of 40

3.4.5 Photographs of Power Frequency Harmonics and Flicker Emission Tests Configuration. [Power Frequency Harmonics and Flicker Emission Tests- Harmonics] [Power Frequency Harmonics and Flicker Emission Tests- Flicker] Page Number : Page 24 of 40

3.5 Electrostatic Discharge Immunity Test In order to minimize the impact of environmental parameters on test results, the tests shall be carried out in climatic and electromagnetic reference conditions as specified in EN 61547:2009. The test programs and software shall be chosen so as to exercise all normal modes of operation of the EUT. The use of special exercising software is encouraged, but permitted only where it can be shown that the EUT is being comprehensively exercised. The testing shall be performed by direct and indirect application of discharges to the EUT according to a test plan. 3.5.1 Test Condition EUT : SLW320N571N1A Test Standard : EN 61547:2009 Test Method : EN 61000-4-2:2009 Test Date : 13 January 2017 Test Voltage : Contact 4 kv, Air (2,4,8) kv Performance criterion : B Temperature/Humidity/Pressure : 19 C / 34 % R.H. / 100.5 kpa 3.5.2 Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use ESD Simulator EDS30V 3CTEST ES0121601 04. 01. 2017 3.5.3 Test Result of Electrostatic Discharge Immunity Test Electrostatic Discharge Immunity Test : PASS The equipment meets the requirements. Page Number : Page 25 of 40

Test data sheet follows. Test Point Discharge Type CD=Contact AD=Air Test Voltage(kV) Tested No Observation Result VCP CD 4 kv Each 10 times Normal PASS (A) HCP CD 4 kv Each 10 times Normal PASS (A) EUT Case AD (2,4,8) kv Each 10 times Normal PASS (A) [Test Point] AD CD Front Rear Left Right Remarks 1. The primary functions as described below were fully functional during and after test. - Normal Operation Mode 2. The direct contact discharge test was excluded because there is no applicable surface on EUT. Page Number : Page 26 of 40

3.5.4 Photographs of Electrostatic Discharge Immunity Test Configuration [Electrostatic Discharge Immunity Test] Page Number : Page 27 of 40

3.6 Radiated, radio-frequency, electromagnetic field immunity test Tests were conducted in accordance with EN 61547:2009 over the frequency range of 80 MHz to 1 000 MHz. The transmitting antenna was located 3 meters from the EUT at a height of 1 meter above the floor. Front, sides and back of the EUT were exposed to a uniform field of 3 V/m using both horizontal and vertical antenna polarizations. 3.6.1 Test Condition EUT : SLW320N571N1A Test Standard : EN 61547:2009 Test Method : EN 61000-4-3:2006+A2:2010 Test Date : 13 January 2017 Test field strength (V/m) : 3 V/m Performance criterion : A Temperature/Humidity/Pressure : 20 C / 32 % R.H. / 100.4 kpa 3.6.2 Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Signal Generator SME06 ROHDE & SCHWARZ 838529/090 06. 08. 2017 RF Power Amplifier ITA0300KL-500 Infinitech N/A 06. 22. 2017 RF Power Amplifier ITA0750KL-500 Infinitech N/A 06. 22. 2017 Log periodic Antenna K9128 Airlinklab 2016-001 N/A 3.6.3 Test Result of Radiated, radio-frequency, electromagnetic field immunity test Electromagnetic field immunity test : PASS The equipment meets the requirements. Page Number : Page 28 of 40

Test data sheet follows. Frequency Range (MHz) Position (Angle) Antenna Polarity Field Strength (V/m) Modulation Result 80-1 000 Front Vertical 3 80 % AM (1 khz) PASS (A) 80-1 000 Rear Vertical 3 80 % AM (1 khz) PASS (A) 80-1 000 Right Vertical 3 80 % AM (1 khz) PASS (A) 80-1 000 Left Vertical 3 80 % AM (1 khz) PASS (A) 80-1 000 Front Horizontal 3 80 % AM (1 khz) PASS (A) 80-1 000 Rear Horizontal 3 80 % AM (1 khz) PASS (A) 80-1 000 Right Horizontal 3 80 % AM (1 khz) PASS (A) 80-1 000 Left Horizontal 3 80 % AM (1 khz) PASS (A) Remarks 1. The primary functions as described below were fully functional during and after test. - Normal Operation Mode 3.6.4 Photographs of Radiated, radio-frequency, electromagnetic field immunity test Configuration [Radiated, radio-frequency, electromagnetic field immunity test] Page Number : Page 29 of 40

3.7 Electrical fast transient/burst immunity test Tests were conducted in accordance with EN 61547:2009. Tests were performed to 1 kv to AC power lines. 3.7.1 Test Condition EUT : SLW320N571N1A Test Standard : EN 61547:2009 Test Method : EN 61000-4-4:2012 Test Date : 13 January 2017 Test Voltage : 1 kv (power lines) Performance criterion : B Temperature/Humidity/Pressure : 19 C / 34 % R.H. / 100.5 kpa 3.7.2 Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Compact Immunity Simulator CCS600 3CTEST ES0801543 09. 10. 2017 3.7.3 Test Result of Electrical fast transient/burst immunity test Electrical fast transient/burst immunity test : PASS The equipment meets the requirements. Page Number : Page 30 of 40

Test data sheet follows. Line Voltage Coupling Inject Time (sec) Result L1-N 1 kv Direct 120 PASS (A) Remarks 1. The primary functions as described below were fully functional during and after test. - Normal Operation Mode 2. PE port test was excluded because there was no PE port on the power for the test. 3.7.4 Photographs of Electrical fast transient/burst immunity test Configuration [Electrical fast transient/burst immunity test] Page Number : Page 31 of 40

3.8 Surge immunity test Tests were conducted in accordance with EN 61547:2009. Tests were performed to 1.0 kv to AC Line to Line and 2.0 kv to Line to Ground. 3.8.1 Test Condition Test Voltage Test levels EUT : SLW320N571N1A Test Standard : EN 61547:2009 Test Method : EN 61000-4-5:2014 EUT Input : AC 230 V, 50 Hz Test Date : 13 January 2017 Test Voltage : 1.0 kv (Line to Line), 2.0 kv (Line to Ground) Performance criterion : B Temperature/Humidity/Pressure : 19 C / 34 % R.H. / 100.4 kpa Characteristics Self-ballasted lamps and semi-luminaires Test levels Device Luminaries and independent auxiliaries Input Power 25 W > 25 W Wave-shape data 1.2/50 µs 1.2/50 µs 1.2/50 µs Line to Line 0.5 kv 0.5 kv 1.0 kv Line to Ground 1.0 kv 1.0 kv 2.0 kv 3.8.2 Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Compact Immunity Simulator CCS600 3CTEST ES0801543 09. 10. 2017 3.8.3 Test Result of Surge immunity test Surge immunity test : PASS The equipment meets the requirements. Page Number : Page 32 of 40

Test data sheet follows. Line Voltage (kv) Coupling Phase(Degree) Inject (count - min) Result L1-N (0.5, 1.0) kv 18 F 90, 270 5 times - 5 min PASS (A) Remarks 1. The primary functions as described below were fully functional during and after test. - Normal Operation Mode 2. PE port test was excluded because there was no PE port on the power for the test. 3. The input power of EUT is over 25 W. 3.8.4 Photographs of Surge immunity test Configuration [Surge immunity test] Page Number : Page 33 of 40

3.9 Conducted immunity test Tests were conducted in accordance with EN 61547:2009. Over the frequency range of 150 khz to 80 MHz. Tests were performed at 3 V on power line. 3.9.1 Test Condition EUT : SLW320N571N1A Test Standard : EN 61547:2009 Test Method EN 61000-4-6:2014 Test Date : 13 January 2017 Test Voltage : 3 V Performance criterion : A Temperature/Humidity/Pressure : 16 C / 39 % R.H. / 100.6 kpa 3.9.2 Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use RF Power Amplifier 5085 OPHIR RF 1006 01. 05. 2018 Signal Generator SMT03 ROHDE & SCHWARZ 826919/008 01. 05. 2018 Attenuator 200W6dB N/A N/A N/A CDN FCC-801-M2-32A FCC 03042 01. 06. 2018 3.9.3 Test Result of Conducted immunity test Conducted immunity test : PASS The equipment meets the requirements. Page Number : Page 34 of 40

Test data sheet follows. Frequency Test port (MHz) Coupling Dwell time Modulation Step Size Result Power 0.15 80 CDN (M2) 1 s 80 % AM (1 khz) 1.0 % PASS (A) Remarks 1. The primary functions as described below were fully functional during and after test. - Normal Operation Mode 3.9.4 Photographs of Conducted immunity test Configuration [Conducted immunity test] Page Number : Page 35 of 40

3.10 Voltage Dips and Short interruptions immunity test Voltage variations tests were conducted in accordance with EN 61547:2009. 3.10.1 Test Condition EUT : SLW320N571N1A Test Standard : EN 61547:2009 Test Method : EN 61000-4-11:2004 Test Date : 13 January 2017 Voltage Dip : 70 % (10 periods) Short interruptions : 0 % (0.5 periods) Performance criterion : 70 % (10 periods) - C, 0 % (0.5 periods) - B Temperature/Humidity/Pressure : 16 C / 34 % R.H. / 100.4 kpa 3.10.2 Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Compact Immunity Simulator CCS600 3CTEST ES0801543 03. 24. 2017 3.10.3 Test Result of Voltage Dips and Short interruptions immunity test Voltage Dips and Short interruptions immunity test : PASS The equipment meets the requirements. Page Number : Page 36 of 40

Test data sheet follows. Test voltage level % Number of periods Angle ( ) Criteria Result 70 10 0, 180 C PASS (B) 0 0.5 0, 180 B PASS (A) Remarks 1. EUT was turned off at the test of Short interruptions in 70 % (10 periods), but it was fully functional after test. 2. Except for the test of Short interruptions in 70 % (10 periods), the primary functions as described below were fully functional during and after test. 3.10.4 Photographs of Voltage Dips and Short interruptions immunity test Configuration [Voltage Dips and Short interruptions immunity test] Page Number : Page 37 of 40

4. EUT PHOTOGRAPHS [Front of EUT] [Rear of EUT] Page Number : Page 38 of 40

[Front of PCB board] [Rear of PCB board] Page Number : Page 39 of 40

[Multi model label] Page Number : Page 40 of 40